Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Paediatr Anaesth ; 24(6): 635-7, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24612230

RESUMEN

We describe the use of inferior alveolar nerve blocks (IANBs) for postoperative pain control for a neonate undergoing mandibular distraction and osteotomies. In this case, bilateral IANBs were effective in keeping low pain scores as assessed on the neonatal infant pain scale (NIPS) and the amount of opioid and adjuvant analgesics used. The blocks were assessed to have lasted approximately 24 h making serial blocks for pain control logistically feasible. Additionally, pain control was improved throughout the period of distractor advancement (approximately 7 days). We propose the routine use of this regional technique for improved pain control after this procedure in neonates and suggest that improved pain control may facilitate earlier extubation in this challenging population.


Asunto(s)
Nervio Mandibular , Reconstrucción Mandibular/métodos , Bloqueo Nervioso/métodos , Osteogénesis por Distracción/métodos , Osteotomía/métodos , Dolor Postoperatorio/tratamiento farmacológico , Anestésicos Locales , Bupivacaína , Humanos , Lactante , Masculino , Dimensión del Dolor/efectos de los fármacos
2.
Paediatr Anaesth ; 23(10): 927-33, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23521105

RESUMEN

BACKGROUND: The cuff pressure for optimal airway sealing with first-generation laryngeal mask airway has been shown to be 40 cm H(2)O in children. Currently, there are no data regarding the ideal intracuff pressure for the laryngeal mask airway Supreme (Supreme) in children. OBJECTIVES: To compare the clinical performance of the laryngeal mask airway supreme with the laryngeal mask airway unique in infants and children. MATERIALS AND METHODS: One hundred eighty children were assigned to receive either a Supreme or a laryngeal mask airway-U. We hypothesized higher airway leak pressure with the Supreme at both 40 cm H(2)O and 60 cm H(2)O, when compared with the laryngeal mask airway-U. Ease and time of insertion, insertion attempts, fiber optic examination, quality of airway, efficacy of mechanical ventilation, success of gastric tube placement (Supreme), incidence of gastric insufflation, and complications were also assessed. RESULTS: Airway leak pressure at an intracuff pressure of 60 cm H(2)O for the Supreme was 17.4 (5.2) vs laryngeal mask airway-U at 18.4 (6.6) cm H(2)O and did not differ when compared to an intracuff pressure of 40 cm H(2)O for both devices; Supreme at 17.2 (5) vs laryngeal mask airway-U at 17.7 (6) cm H(2)O. The laryngeal mask airway-U was associated with higher first-attempt success rates. The Supreme was associated with less gastric insufflation than the laryngeal mask airway-U. CONCLUSIONS: Intracuff pressures of 40 cm H(2)O may be sufficient for the Supreme in children, and there may be no added benefit of an intracuff pressure of 60 cm H(2)O, as leak pressures were similar. The Supreme may be preferred over the laryngeal mask airway-U for its lower rates of gastric insufflation and provision for gastric access when mechanical ventilation is utilized.


Asunto(s)
Máscaras Laríngeas , Presión del Aire , Manejo de la Vía Aérea/instrumentación , Niño , Preescolar , Falla de Equipo , Femenino , Humanos , Lactante , Insuflación , Intubación Gastrointestinal , Masculino , Faringitis/epidemiología , Faringitis/etiología , Complicaciones Posoperatorias/epidemiología , Respiración Artificial/instrumentación , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...