Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Saudi Dent J ; 36(4): 656-660, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38690374

RESUMEN

Introduction: Comparative evaluation of the newly introduced; RACE EVO file system to the currently well-performing file systems like HyFlex EDM OneFile, Vortex Blue, ProTaper Gold (PTG) with regards to the cyclic fatigue resistance. Materials: &Methods.The endodontic rotary files under evaluation were segregated into four groups as follows:; RACE EVO, PTG, Vortex Blue, and HyFlex EDM OneFile. A detailed physical analysis of the cyclic fatigue resistance was performed in 15 files of each type (n = 60). Under the test conditions of 37 °C the test samples were subjected to continuous motion at the manufacturer recommended speed within an artificial curved canal until it fractured. For all the test samples, with the recording of time of fracture, calculation was done for number of cycles to fracture (NCF). In addition, the length of the fractured segment was determined. The fractured surface was further evaluated with scanning electron microscopic (SEM) images. Results: Highest significance for NCF was seen in HyFlex EDM OneFile followed by the Vortex Blue, PTG, and; RACE EVO (p < 0.05) by analyzing the data statistically. Significant differences among the lengths of the fractured segments were evident among tested files, ranging between 4.73 and 6.3 mm (p < 0.05) with HyFlex EDM OneFile uniquely differentiating from the others showing the fracture at 6.3 mm. The common features of cyclic fatigue failure was further substantiated by SEM images. Conclusions: Compared to the HyFlex EDM OneFile, Vortex Blue, and PTG files; RACE EVO demonstrated significantly lower resistance to cyclic fatigue.

2.
Int J Dent ; 2020: 2728949, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32399032

RESUMEN

The aim of this study is to evaluate the knowledge, attitude, and perception of radiation hazard and preventive measures among dental undergraduate students, general practitioners, endodontic postgraduate students, and endodontists in Saudi Arabia. Multiple choice questions questionnaires were distributed among undergraduate and endodontic postgraduate dental students, general practitioners, and endodontists in the colleges of dentistry in Saudi Arabia, government hospitals, and private clinics. The questionnaire included sociodemographic data, assessment of the knowledge of radiation physics and biology, assessment of the practice of dental radiography, and assessment of knowledge of radiation protection. Chi-square test was used for individual and multiresponse analysis. Level of statistical significance was set at P ≤ 0.05. Three hundred and twenty-nine responded to the questionnaire. More than half of the respondents agreed that dental X-ray is hazardous to health (60.79%), and 68.1% were familiar with ALARA (as low as reasonably achievable) principle. However, only 34% are familiar with the recommendations of the National Council on Radiation Protection (NCRP) and International Commission on Radiological Protection (ICRP). The use of lead apron and thyroid collar for patients' protection from X-ray radiation was practiced among endodontic postgraduate students more frequently as well as those who are proactive in the academic field. Undergraduate students, endodontic postgraduate students, and endodontists in the academic field were the most aware towards radiation reduction measures. The use of the preventive measures needs to be emphasized more among general practitioners, endodontic postgraduate students, and endodontists especially in governmental hospitals and private sectors.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...