Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Rev Esp Cardiol (Engl Ed) ; 76(3): 173-182, 2023 Mar.
Artículo en Inglés, Español | MEDLINE | ID: mdl-35809892

RESUMEN

INTRODUCTION AND OBJECTIVES: Late gadolinium-enhanced cardiac magnetic resonance (LGE-CMR) allows noninvasive detection of left atrial fibrosis in patients with atrial fibrillation (AF). However, whether the same methodology can be used in the right atrium (RA) remains unknown. Our aim was to define a standardized threshold to characterize RA fibrosis in LGE-CMR. METHODS: A 3 Tesla LGE-CMR was performed in 53 individuals; the RA was segmented, and the image intensity ratio (IIR) calculated for the RA wall using 1 557 767 IIR pixels (40 994±10 693 per patient). The upper limit of normality of the IIR (mean IIR+2 standard deviations) was estimated in healthy volunteers (n=9), and patients who had undergone previous typical atrial flutter ablation (n=9) were used to establish the dense scar threshold. Paroxysmal and persistent AF patients (n=10 each) were used for validation. IIR values were correlated with a high-density bipolar voltage map in 15 patients undergoing AF ablation. RESULTS: The upper normality limit (total fibrosis threshold) in healthy volunteers was set at an IIR = 1.21. In the postablation group, 60% of the maximum IIR pixel (dense fibrosis threshold) was calculated as IIR = 1.29. Endocardial bipolar voltage showed a weak but significant correlation with IIR. The overall accuracy between the electroanatomical map and LGE-CMR to characterize fibrosis was 56%. CONCLUSIONS: An IIR > 1.21 was determined to be the threshold for the detection of right atrial fibrosis, while an IIR > 1.29 differentiates interstitial fibrosis from dense scar. Despite differences between the left and right atria, fibrosis could be assessed with LGE-CMR using similar thresholds in both chambers.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Cicatriz/patología , Cicatriz/cirugía , Medios de Contraste , Atrios Cardíacos/patología , Imagen por Resonancia Magnética/métodos , Fibrilación Atrial/cirugía , Fibrosis , Ablación por Catéter/métodos , Gadolinio , Espectroscopía de Resonancia Magnética
3.
Europace ; 21(5): 724-731, 2019 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-30649273

RESUMEN

AIMS: Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) may define left atrial (LA) anatomy and structural remodelling, and facilitate atrial fibrillation (AF) ablation. We aimed to assess the intra- and inter-observer reproducibility and agreement of LGE-CMR parameters with direct application to AF ablation techniques. METHODS AND RESULTS: One experienced and one non-experienced observer performed complete LGE-CMR data analysis twice, on different days, in 40 randomly selected LGE-CMR examinations [20 performed before ablation (pre-ablation) and 20 performed 3 months after ablation (post-ablation)]. Four additional observers (two experienced and two non-experienced) performed complete LGE-CMR data analysis in a subgroup of 30 patients (15 pre-ablation and 15 post-ablation). All LGE-CMR were performed in sinus rhythm. Intra- and inter-observer reproducibility of LA volume, LA area, and sphericity index (SI) was high: coefficient of variation <10% and intraclass correlation coefficient >0.71. Geometric congruency of repeated reconstruction of LA shape was high: maximal error <5 mm for intra-observer and <8 mm for inter-observer. The precision of scar location increased with extent of scar, and was high (Dice coefficient >0.75) when the scar area was >5 cm2 for a single observer and >15 cm2 for multiple observers. Non-experienced observers performed equally well to experienced observers. CONCLUSION: Late gadolinium enhancement cardiac magnetic resonance measurements of LA area, volume, and SI were reproducible, and geometric congruency of LA shape was high. Location of scar was precise for scar areas >5 cm2 for single observers and >15 cm2 for multiple observers, regardless of the observers' experience. These results may serve as a reference for future studies on the role for substrate-based AF ablation procedures.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter/métodos , Gadolinio/farmacología , Atrios Cardíacos , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Fibrilación Atrial/patología , Fibrilación Atrial/cirugía , Remodelación Atrial , Medios de Contraste/farmacología , Femenino , Fibrosis , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/patología , Humanos , Masculino , Persona de Mediana Edad , Cuidados Preoperatorios/métodos , Reproducibilidad de los Resultados
4.
Circ Arrhythm Electrophysiol ; 11(12): e006659, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30562102

RESUMEN

BACKGROUND: There is limited knowledge about the impact of anatomic gaps as assessed by delayed gadolinium enhancement cardiac magnetic resonance on atrial fibrillation (AF) recurrence after first pulmonary vein (PV) isolation. METHODS: Consecutive patients underwent delayed gadolinium enhancement cardiac magnetic resonance 3 months after radiofrequency circumferential PV isolation. Delayed gadolinium enhancement cardiac magnetic resonance images were assessed from 360 PV resulting in 2880 segments in the 2×8-segment model from 94 patients (52±11 years, 62% paroxysmal AF). Left atria were segmented using dedicated software. Anatomic gap was defined as discontinuation of the ablation line by ≥3 mm. Relative gap length was calculated as absolute gap length divided by the total length of the ablation line. AF recurrence was assessed after a mean follow-up duration of 15±10 months Results: Mean number of anatomic gaps was 5.4 per patient. Recurrence within the first year of ablation was observed in 21 patients with paroxysmal AF (36%) and 19 patients with persistent AF (53%). In the univariate analysis, CHA2DS2-VASc score, AF type, and relative gap length were predictive of recurrence. In the multivariate analysis, only relative gap length was significantly associated with recurrence (hazard ratio, 1.16 [1.02-1.31] per each 10% of gap). CONCLUSIONS: The total relative gap length but not the number of anatomic gaps in the PV ablation line as assessed by delayed gadolinium enhancement cardiac magnetic resonance was associated with AF recurrence 1 year after first PV isolation. An increase of 10% relative gap length increased the likelihood of AF recurrence by 16%.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Gadolinio , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Venas Pulmonares/cirugía , Adulto , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/mortalidad , Ablación por Catéter/mortalidad , Estudios de Cohortes , Medios de Contraste , Femenino , Humanos , Aumento de la Imagen/métodos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Análisis Multivariante , Modelos de Riesgos Proporcionales , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , España , Estadísticas no Paramétricas , Análisis de Supervivencia
5.
Europace ; 20(12): 1959-1965, 2018 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-29860416

RESUMEN

Aims: Left atrial (LA) fibrosis can be identified by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) in patients with atrial fibrillation (AF). However, there is limited information about anatomical fibrosis distribution in the left atrium. The aim is to determine whether there is a preferential spatial distribution of fibrosis in the left atrium in patients with AF. Methods and results: A 3-Tesla LGE-CMR was performed in 113 consecutive patients referred for AF ablation. Images were post-processed and analysed using ADAS-AF software (Galgo Medical), which allows fibrosis identification in 3D colour-coded shells. A regional semiautomatic LA parcellation software was used to divide the atrial wall into 12 segments: 1-4, posterior wall; 5-6, floor; 7, septal wall; 8-11, anterior wall; 12, lateral wall. The presence and amount of fibrosis in each segment was obtained for analysis. After exclusions for artefacts and insufficient image quality, 76 LGE-MRI images (68%) were suitable for fibrosis analysis. Segments 3 and 5, closest to the left inferior pulmonary vein, had significantly higher fibrosis (40.42% ± 23.96 and 25.82% ± 21.24, respectively; P < 0.001), compared with other segments. Segments 8 and 10 in the anterior wall contained the lowest fibrosis (2.54% ± 5.78 and 3.82% ± 11.59, respectively; P < 0.001). Age >60 years was significantly associated with increased LA fibrosis [95% confidence interval (CI) 0.19-8.39, P = 0.04] and persistent AF approached significance (95% CI -0.19% to 7.83%, P = 0.08). Conclusion: In patients with AF, the fibrotic area is preferentially located at the posterior wall and floor around the antrum of the left inferior pulmonary vein. Age >60 years was associated with increased fibrosis.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Función del Atrio Izquierdo , Remodelación Atrial , Medios de Contraste/administración & dosificación , Atrios Cardíacos/diagnóstico por imagen , Imagen por Resonancia Magnética , Compuestos Organometálicos/administración & dosificación , Venas Pulmonares/diagnóstico por imagen , Factores de Edad , Anciano , Fibrilación Atrial/patología , Fibrilación Atrial/fisiopatología , Femenino , Fibrosis , Atrios Cardíacos/patología , Atrios Cardíacos/fisiopatología , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Venas Pulmonares/patología , Venas Pulmonares/fisiopatología , Factores de Riesgo
6.
J Cardiovasc Electrophysiol ; 29(8): 1065-1072, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29722466

RESUMEN

INTRODUCTION: The purpose of this study was to compare the anatomical characteristics of scar formation achieved by visual-guided laser balloon (Laser) and radiofrequency (RF) pulmonary vein isolation (PVI), using late-gadolinium-enhanced cardiac magnetic resonance imaging (LGE-CMR). METHODS AND RESULTS: We included 17 patients with paroxysmal or early persistent drug resistant AF who underwent Laser ablation; 2 were excluded due to procedure-related complications. The sample was matched with a historical group of 15 patients who underwent PVI using RF. LGE-CMR sequences were acquired before and 3 months post-PVI. Ablation gaps were defined as pulmonary vein (PV) perimeter sections showing no gadolinium enhancement. The number of ablation gaps was lower in Laser versus RF ablations (median 7 vs. 14, P  =  0.015). Complete anatomical PVI (circumferential scar around PV, without gaps) was more frequently achieved with Laser than with RF (39% vs. 19% of PVs, P  =  0.025). Fewer gaps were present at the superior and anterior left PV and posterior right PV antral regions in the Laser group, compared to RF. Scar extension into the PVs was similar in both groups, although RF produced more extensive ablation scar toward the LA body. AF recurrences at 1 year were similar in both groups (Laser 36% vs. RF 27%, P  =  1.00). CONCLUSIONS: Compared to RF, Laser ablation achieved more complete anatomical PVI, with less LA scar extension. However, AF recurrence appears to be similar after Laser compared to RF ablation. Further studies are needed to assess whether the anatomical advantages of Laser ablation translate into clinical benefit in patients with AF.


Asunto(s)
Gadolinio , Imagen por Resonancia Cinemagnética/métodos , Complicaciones Posoperatorias/diagnóstico por imagen , Venas Pulmonares/diagnóstico por imagen , Ablación por Radiofrecuencia/tendencias , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Terapia por Láser/efectos adversos , Terapia por Láser/tendencias , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Venas Pulmonares/cirugía , Ablación por Radiofrecuencia/efectos adversos
8.
J Cardiovasc Electrophysiol ; 29(5): 740-746, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29528532

RESUMEN

INTRODUCTION: To investigate the relation between left atrial (LA) volume, sphericity, and fibrotic content derived from contrast-enhanced cardiac magnetic resonance imaging (CE-CMR) and their impact on the outcome of catheter ablation for atrial fibrillation (AF). METHODS AND RESULTS: In 83 patients undergoing catheter ablation for AF, CE-CMR was used to assess LA volume, sphericity, and fibrosis. There was a significant correlation between LA volume and sphericity (R  =  0.535, P < 0.001) and between LA volume and fibrosis (R  =  0.241, P  =  0.029). Multivariate analyses demonstrated that LA volume was the strongest independent predictor of AF recurrence after catheter ablation (1.019, P  =  0.018). CONCLUSION: LA volume, sphericity, and fibrosis were closely related; however, LA volume was the strongest predictor of AF recurrence after catheter ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Función del Atrio Izquierdo , Remodelación Atrial , Ablación por Catéter , Atrios Cardíacos/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Medios de Contraste/administración & dosificación , Femenino , Fibrosis , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Frecuencia Cardíaca , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Compuestos Organometálicos/administración & dosificación , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
12.
Europace ; 19(8): 1272-1279, 2017 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-27940935

RESUMEN

AIMS: Identification of left atrial (LA) fibrosis through late gadolinium-enhanced cardiac magnetic resonance (LGE-CMR) remains controversial due to the heterogeneity and lack of reproducibility of proposed methods. Our aim is to describe a normalized, reproducible, standardized method to evaluate LA fibrosis through LGE-CMR. METHODS AND RESULTS: Electrocardiogram- and respiratory-gated 3-Tesla LGE-CMR was performed in 10 healthy young volunteers and 30 patients with atrial fibrillation (AF): 10 with paroxysmal AF, 10 with persistent AF, and 10 with a previous AF ablation procedure. Local image intensity ratio (IIR) of the LA was calculated as the absolute pixel intensity to mean blood pool intensity ratio. The healthy atrial tissue threshold was defined in young healthy volunteers (upper limit of normality set at IIR tissue mean plus 2 SDs). Dense atrial scarring was characterized in patients with previous radiofrequency-induced scarring (post-AF ablation patients). Validation groups consisted of patients with paroxysmal and persistent AFs. The upper limit of normal IIR was 1.20; IIR values higher than 1.32 (60% of mean maximum pixel intensity in post-ablation patients) were considered dense scar. Image intensity ratio values between 1.2 and 1.32 identified interstitial fibrosis. Patients with paroxysmal and persistent AFs had less atrial fibrotic tissue compared with post-ablation patients. Endocardial bipolar voltage was correlated to IIR values. CONCLUSIONS: An IIR of 1.2 identifies the upper limit of normality in healthy young individuals. An IIR of >1.32 defines dense atrial fibrosis in post-ablation patients. Our results provide a consistent, comparable, and normalized tool to assess atrial arrhythmogenic substrate.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Remodelación Atrial , Medios de Contraste/administración & dosificación , Atrios Cardíacos/diagnóstico por imagen , Imagen por Resonancia Magnética/normas , Compuestos Organometálicos/administración & dosificación , Potenciales de Acción , Adolescente , Adulto , Anciano , Fibrilación Atrial/patología , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Técnicas de Imagen Sincronizada Cardíacas , Estudios de Casos y Controles , Ablación por Catéter , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Fibrosis , Atrios Cardíacos/patología , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Valores de Referencia , Reproducibilidad de los Resultados , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...