Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 267
Filtrar
1.
Obstet Gynecol ; 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38995956

RESUMEN

OBJECTIVE: To evaluate whether continuous glucose monitoring (CGM)-derived glycemic patterns observed throughout pregnancy were associated with adverse perinatal outcomes, specifically fetal growth disorders and hypertensive disorders of pregnancy (HDP). METHODS: We conducted a prospective observational study of individuals with viable singleton pregnancies and screening hemoglobin A1c levels less than 6.5%. Those with preexisting diabetes were excluded. Enrollment occurred at the earliest gestational age before 17 weeks. Participants wore blinded continuous glucose monitors consecutively as willing until delivery. Those with at least 14 days of CGM data were included in analysis. Rates of large-for-gestational-age (LGA) neonates, small-for-gestational age (SGA) neonates, and HDP were assessed. Continuous glucose monitoring-derived glycemic metrics were calculated, including mean glucose level and percent time above and below thresholds. Two-sample t tests were used to compare glycemic metrics between participants with and without adverse perinatal outcomes. RESULTS: Of 937 participants enrolled, 760 met inclusion criteria. Those delivering LGA neonates or who were diagnosed with HDP had higher mean glucose levels (102±9 vs 100±8, P=.01 and 103±8 vs 99±8, P<.001) and spent more time above 120 mg/dL (median 16% vs 12%, P=.006, and 16% vs 12%, P<.001, respectively) and above 140 mg/dL (median 3.9% vs 2.8%, P=.006, and 3.5% vs 2.8%, P<.001, respectively) throughout gestation than those without these outcomes. These findings were present regardless of gestational diabetes mellitus status. Participants with SGA neonates had lower mean glucose levels (97±7 vs 101±8, P=.01) and spent less time above 140 mg/dL (median 1.6% vs 2.3%, P=.01) and more time below 63 mg/dL (median 3.0% vs 2.3%, P=.02) than those without SGA neonates. CONCLUSION: Individuals with LGA neonates or HDP exhibit a slightly higher mean glucose levels and spend more time hyperglycemic in early pregnancy than those who do not experience these outcomes.

2.
Artículo en Inglés | MEDLINE | ID: mdl-39042635

RESUMEN

Objective: To assess the performance of continuous glucose monitoring (CGM)-measured glycemic metrics in predicting development of gestational diabetes mellitus (GDM) and select perinatal complications. Research Methods: In a prospective observational study, CGM data were collected from 760 pregnant females throughout gestation after study enrollment. GDM was diagnosed using the oral glucose tolerance test (OGTT) at 24-34 weeks of gestation. Predictive models were built using logistic and elastic net regression. Predictive performance was assessed by the area under the receiver-operating characteristic (AUROC) curve. Results: The AUROCs of using second trimester percent time >140 mg/dL (TA140) and week 13-14 TA140 in predicting GDM were 0.81 and 0.74, respectively. The AUROCs for predicting large-for-gestational-age (LGA) births and hypertensive disorders of pregnancy (HDP) using second trimester TA140 were both 0.58. When matching the specificity of OGTT, a model using TA140 in weeks 13-14 achieved similar sensitivity to OGTT in predicting HDP (13% vs. 10%, respectively) and LGA (6% for both methods). Elastic net also demonstrated similar AUROC and diagnostic performance with no meaningful improvement by using multiple predictors. Conclusion: CGM-measured hyperglycemic metrics such as TA140 predicted GDM with high AUROCs as early as 13-14 weeks of gestation. These metrics were also similar statistically to the OGTT at 24-34 weeks in predicting perinatal complications, although sensitivity was low for both. CGM could potentially be used as an early screening tool for elevated hyperglycemia during gestation, which could be used in addition to or instead of the OGTT.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38904213

RESUMEN

Aims: The objective of this real-world, observational study was to evaluate change in continuing glucose monitoring (CGM) metrics for 1 year after CGM initiation in adults with noninsulin-treated type 2 diabetes (T2D). Methods: Data were analyzed from Dexcom G6 and G7 users who self-reported: T2D, ≥18 years, gender, no insulin use, and had a baseline percent time in range (TIR) 70-180 mg/dL of ≤70%. Outcomes were change in CGM metrics from baseline to 6 and 12 months overall and for younger (<65 years) and older (≥65 years) cohorts. Additional analyses explored the relationship between use of the high alert feature and change in TIR and time in tight range (TITR) 70-140 mg/dL. Results: CGM users (n = 3,840) were mean (SD) 52.5 (11.2) years, 47.9% female, mean TIR was 41.7% (21.4%), and 12.4% of participants were ≥65 years. Significant improvement in all CGM metrics not meeting target values at baseline was observed at 6 months, with continued improvement at 12 months. Mean baseline TIR increased by 17.3% (32.1%) from 41.7% (21.4%) to 59.0% (28.9%), and mean glucose management indicator decreased by 0.5% (1.2%) from 8.1% (0.9%) to 7.6% (1.1%) (both P < 0.001). Participants who maintained or customized the high alert default setting of 250 mg/dL had a greater increase in TIR and TITR compared with participants who disabled the alert. Days of CGM use over 12 months were high in 84.7% (15.9%). Conclusion: In this large, real-world study of adults with suboptimally controlled T2D not using insulin, Dexcom CGM use was associated with meaningful improvements in glycemic control over 12 months. Use of the high alert system feature was positively associated with glycemic outcomes. High use of CGM over 12 months suggests benefits related to consistent CGM use in this population.

4.
Diabetes Ther ; 15(8): 1785-1797, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38907935

RESUMEN

INTRODUCTION: Insulin efsitora alfa (efsitora) is a basal insulin with a flat pharmacokinetic profile and long half-life, enabling weekly dosing. These attributes may provide stable glucose levels. This exploratory phase 1 study aimed to assess the hypoglycemic risk during experimental conditions that mimic situations encountered in daily life. METHODS: This was a single-site, open-label, two-period, fixed-sequence study in participants with type 2 diabetes (T2D) previously treated with basal insulin. The incidence, duration, and nadir glucose of hypoglycemia were assessed after treatment with efsitora versus insulin glargine (glargine) during three provocation conditions: 24-h prolonged fasting, prolonged fasting with exercise, and double dosing of study insulin. RESULTS: The 54 enrolled adults (BMI 21.8-39.7 kg/m2, HbA1c 6.5-9.4%) achieved stable fasting glucose before undergoing provocation. Most hypoglycemic events were level 1 (≥ 54 to < 70 mg/dL) and resolved spontaneously or after oral glucose. The incidences of level 1 hypoglycemia for efsitora and glargine were not significantly different: for prolonged fasting, the incidences were 44.7 vs. 42.6% and the difference in proportion was 2.1% (95% CI: - 17.2, 21.4); for prolonged fasting with exercise, the corresponding values were 65.9 vs. 50.0% and 15.9% (- 3.0, 34.8); for double dosing, the corresponding values were 68.1 vs. 61.7% and 6.4% (- 12.8, 25.6). Level 2 hypoglycemia (< 54 mg/dL) was infrequent during both treatments and all provocations. No severe hypoglycemia was observed. Mean nadir glucose (range 62.8-66.3 mg/dL) and hypoglycemia duration (range 76.6-115.2 min) were also similar for the two treatments, depending on the provocation. CONCLUSION: Overall, weekly efsitora did not increase the incidence, duration, or severity of hypoglycemia compared to daily glargine during provocation periods in patients with T2D. TRIAL REGISTRATION: ClinicalTrials.gov identifier NCT04957914.

5.
Artículo en Inglés | MEDLINE | ID: mdl-38805310

RESUMEN

Background:There is a need for accurate glycemic control metrics in patients with diabetes and end-stage kidney disease (ESKD). Hence, we assessed the relationship of continuous glucose monitoring (CGM) metrics and laboratory-measured hemoglobin A1c (HbA1c) in patients with type 2 diabetes (T2D) treated by hemodialysis. Methods: This prospective observational study included adults (age 18-80 years) with T2D (HbA1c 5%-12%), treated by hemodialysis (for at least 90 days). Participants used a Dexcom G6 Pro CGM for 10 days. Correlation analyses between CGM metrics [mean glucose, glucose management indicator (GMI), and time-in-range (TIR 70-180 mg/dL)] and HbA1c were performed. Results: Among 59 participants (mean age was 57.7 ± 9.3 years, 58% were female, 86% were non-Hispanic blacks), the CGM mean glucose level was 188.9 ± 45 mg/dL (95% CI: 177.2, 200.7), the mean HbA1c and GMI were 7.1% ± 1.3% and 7.8% ± 1.1%, respectively (difference 0.74% ± 0.95). GMI had a strong negative correlation with TIR 70-180 mg/dL (r = -0.96). The correlation between GMI and HbA1c (r = 0.68) was moderate. Up to 29% of participants had a discordance between HbA1c and GMI of <0.5%, with 22% having a discordance between 0.5% and 1%, and 49% having a discordance of >1%. Conclusions: In patients with diabetes and ESKD treated by hemodialysis, the GMI has a strong correlation with TIR, while HbA1c underestimated the average glucose and GMI. Given the limitations of HbA1c in this population, GMI or mean glucose and TIR may be considered as more appropriate glucose control markers.

6.
Artículo en Inglés | MEDLINE | ID: mdl-38758213

RESUMEN

Background: Connected insulin pens capture data on insulin dosing/timing and can integrate with continuous glucose monitoring (CGM) devices with essential insulin and glucose metrics combined into a single platform. Standardization of connected insulin pen reports is desirable to enhance clinical utility with a single report. Methods: An international expert panel was convened to develop a standardized connected insulin pen report incorporating insulin and glucose metrics into a single report containing clinically useful information. An extensive literature review and identification of examples of current connected insulin pen reports were performed serving as the basis for creation of a draft of a standardized connected insulin pen report. The expert panel participated in three virtual standardization meetings and online surveys. Results: The Ambulatory Glucose Profile (AGP) Report: Connected Insulin Pen brings all clinically relevant CGM-derived glucose and connected insulin pen metrics into a single simplified two-page report. The first page contains the time in ranges bar, summary of key insulin and glucose metrics, the AGP curve, and detailed basal (long-acting) insulin assessment. The second page contains the bolus (mealtime and correction) insulin assessment periods with information on meal timing, insulin-to-carbohydrate ratio, average bolus insulin dose, and number of days with bolus doses recorded. The report's second page contains daily glucose profiles with an overlay of the timing and amount of basal and bolus insulin administered. Conclusion: The AGP Report: Connected Insulin Pen is a standardized clinically useful report that should be considered by companies developing connected pen technology as part of their system reporting/output.

7.
Diabetes Care ; 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38701400

RESUMEN

OBJECTIVE: To determine whether continuous glucose monitoring (CGM)-derived glycemic patterns can characterize pregnancies with gestational diabetes mellitus (GDM) as diagnosed by standard oral glucose tolerance test at 24-28 weeks' gestation compared with those without GDM. RESEARCH DESIGN AND METHODS: The analysis includes 768 individuals enrolled from two sites prior to 17 weeks' gestation between June 2020 and December 2021 in a prospective observational study. Participants wore blinded Dexcom G6 CGMs throughout gestation. Main outcome of interest was a diagnosis of GDM by oral glucose tolerance test (OGTT). Glycemic levels in participants with GDM versus without GDM were characterized using CGM-measured glycemic metrics. RESULTS: Participants with GDM (n = 58 [8%]) had higher mean glucose (109 ± 13 vs. 100 ± 8 mg/dL [6.0 ± 0.7 vs. 5.6 ± 0.4 mmol/L], P < 0.001), greater glucose SD (23 ± 4 vs. 19 ± 3 mg/dL [1.3 ± 0.2 vs. 1.1 ± 0.2 mmol/L], P < 0.001), less time in range 63-120 mg/dL (3.5-6.7 mmol/L) (70% ± 17% vs. 84% ± 8%, P < 0.001), greater percent time >120 mg/dL (>6.7 mmol/L) (median 23% vs. 12%, P < 0.001), and greater percent time >140 mg/dL (>7.8 mmol/L) (median 7.4% vs. 2.7%, P < 0.001) than those without GDM throughout gestation prior to OGTT. Median percent time >120 mg/dL (>6.7 mmol/L) and time >140 mg/dL (>7.8 mmol/L) were higher as early as 13-14 weeks of gestation (32% vs. 14%, P < 0.001, and 5.2% vs. 2.0%, P < 0.001, respectively) and persisted during the entire study period prior to OGTT. CONCLUSIONS: Prior to OGTT at 24-34 weeks' gestation, pregnant individuals who develop GDM have higher CGM-measured glucose levels and more hyperglycemia compared with those who do not develop GDM.

8.
BMJ Open Diabetes Res Care ; 12(3)2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38729771

RESUMEN

INTRODUCTION: To characterize glucose levels during uncomplicated pregnancies, defined as pregnancy with a hemoglobin A1c <5.7% (<39 mmol/mol) in early pregnancy, and without a large-for-gestational-age birth, hypertensive disorders of pregnancy, or gestational diabetes mellitus (ie, abnormal oral glucose tolerance test). RESEARCH DESIGN AND METHODS: Two sites enrolled 937 pregnant individuals aged 18 years and older prior to reaching 17 gestational weeks; 413 had an uncomplicated pregnancy (mean±SD body mass index (BMI) of 25.3±5.0 kg/m2) and wore Dexcom G6 continuous glucose monitoring (CGM) devices throughout the observed gestational period. Mealtimes were voluntarily recorded. Glycemic levels during gestation were characterized using CGM-measured glycemic metrics. RESULTS: Participants wore CGM for a median of 123 days each. Glucose levels were nearly stable throughout all three trimesters in uncomplicated pregnancies. Overall mean±SD glucose during gestation was 98±7 mg/dL (5.4±0.4 mmol/L), median per cent time 63-120 mg/dL (3.5-6.7 mmol/L) was 86% (IQR: 82-89%), median per cent time <63 mg/dL (3.5 mmol/L) was 1.8%, median per cent time >120 mg/dL (6.7 mmol/L) was 11%, and median per cent time >140 mg/dL (7.8 mmol/L) was 2.5%. Mean post-prandial peak glucose was 126±22 mg/dL (7.0±1.2 mmol/L), and mean post-prandial glycemic excursion was 36±22 mg/dL (2.0±1.2 mmol/L). Higher mean glucose levels were low to moderately associated with pregnant individuals with higher BMIs (103±6 mg/dL (5.7±0.3 mmol/L) for BMI ≥30.0 kg/m2 vs 96±7 mg/dL (5.3±0.4 mmol/L) for BMI 18.5-<25 kg/m2, r=0.35). CONCLUSIONS: Mean glucose levels and time 63-120 mg/dL (3.5-6.7 mmol/L) remained nearly stable throughout pregnancy and values above 140 mg/dL (7.8 mmol/L) were rare. Mean glucose levels in pregnancy trend higher as BMI increases into the overweight/obesity range. The glycemic metrics reported during uncomplicated pregnancies represent treatment targets for pregnant individuals.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Humanos , Femenino , Embarazo , Glucemia/análisis , Adulto , Automonitorización de la Glucosa Sanguínea/métodos , Hemoglobina Glucada/análisis , Diabetes Gestacional/sangre , Diabetes Gestacional/diagnóstico , Prueba de Tolerancia a la Glucosa , Adulto Joven , Estudios de Seguimiento , Biomarcadores/sangre , Biomarcadores/análisis , Monitoreo Continuo de Glucosa
10.
Diabetes Obes Metab ; 26(8): 3020-3030, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38679838

RESUMEN

AIMS: Insulin efsitora alfa (efsitora) is a once-weekly basal insulin. This review describes the study design and rationale of the efsitora phase 3 Once Weekly (QW) Insulin Therapy (QWINT) clinical development programme, including the five trials, QWINT-1 through QWINT-5. MATERIALS AND METHODS: The five trials included insulin-naïve adults (QWINT-1 and -2) with type 2 diabetes (T2D), adults with T2D previously treated with basal insulin (QWINT-3 and -4), and QWINT-5 in adults with type 1 diabetes. All five trials were designed as multicentre, randomized, controlled, open-label, treat-to-target studies to investigate the efficacy and safety of efsitora versus active once-daily basal insulin comparators (insulin glargine U100 or insulin degludec U100). The primary objective of each trial is to compare the change in HbA1c from baseline to week 26 or 52 between efsitora and the active comparator. The key secondary objectives include change in fasting glucose, insulin dose and continuous glucose monitoring variables, and patient-reported outcome questionnaires. CONCLUSIONS: The QWINT development programme includes a racially and geographically diverse population to provide important information regarding the efficacy and safety of efsitora and its clinical management of people with diabetes.


Asunto(s)
Ensayos Clínicos Fase III como Asunto , Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Esquema de Medicación , Hipoglucemiantes , Insulina de Acción Prolongada , Humanos , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/sangre , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/uso terapéutico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Insulina de Acción Prolongada/administración & dosificación , Insulina de Acción Prolongada/uso terapéutico , Glucemia/efectos de los fármacos , Glucemia/análisis , Hemoglobina Glucada/análisis , Hemoglobina Glucada/efectos de los fármacos , Adulto , Insulina Glargina/administración & dosificación , Insulina Glargina/uso terapéutico , Ensayos Clínicos Controlados Aleatorios como Asunto , Femenino , Masculino , Proyectos de Investigación , Insulina/administración & dosificación , Insulina/uso terapéutico , Estudios Multicéntricos como Asunto , Persona de Mediana Edad
11.
Artículo en Inglés | MEDLINE | ID: mdl-38452101

RESUMEN

Background: Despite new pharmacotherapy, most patients with long-term type 2 diabetes are still hyperglycemic. This could have been solved by insulin with its unlimited potential efficacy, but its dynamic physiology demands frequent titrations which are overdemanding. This report provides a real-life account for a scalable transformation of diabetes care in a community-based endocrinology center by harnessing artificial intelligence-based autonomous insulin titration. Methods: The center embedded the d-Nav® technology and its dedicated clinical support. Reported outcomes include treatment efficacy/safety in the first 600 patients and use of cardiorenal-risk reduction pharmacotherapy. Findings: Patients used d-Nav for 8.2 ± 3.0 months with 82% retention. Age was 67.1 ± 11.5 years and duration of diabetes was 19.8 ± 11.0 years. During the last 3 years before d-Nav, glycated hemoglobin (HbA1c) had been overall higher than 8% and at the beginning of the program it was as high as 8.6% ± 2.1% with 29.3% of the patients with HbA1c >9%. With d-Nav, HbA1c decreased to 7.3% ± 1.2% with 5.7% of patients with HbA1c >9%. During the first 3 months, d-Nav reduced total daily dose of insulin in one of every five patients due to relatively low glucose levels to minimize the risk of hypoglycemia. Glucagon like peptide 1 (GLP-1) receptor agonists or dual GLP-1 and Glucose-dependent insulinotropic polypeptide (GIP) receptor agonists were prescribed in about a half of the patients and sodium glucose cotransporter 2 inhibitor in a third. The frequency of hypoglycemia (<54 mg/dL) was 0.4 ± 0.6/month and severe hypoglycemia 1.7/100-patient-years. Interpretation: The use of d-Nav allowed for improvement in overall diabetes management with appropriate use of both insulin and noninsulin pharmacologic agents in a scalable way.

12.
Diabetes Technol Ther ; 26(3): 203-210, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38444315

RESUMEN

The growing use of continuous glucose monitoring (CGM) has been supported by expert consensus and clinical guidelines on glycemic management in diabetes with time in range (TIR 70-180 mg/dL) representing a key CGM-derived glucose metric. Time in tight range (TITR) has also been proposed for clinical use, spanning largely normal glucose levels of 70-140 mg/dL. However, keeping such narrow glucose ranges can be challenging, and understanding the factors modulating TITR can help achieve these tight glycemic targets. Our real-life study aimed to evaluate the relationship between average glucose (AG) and TIR/TITR in a large cohort (n = 22,006) of CGM users, divided into four groups: self-identified as having type 1 diabetes (T1D) treated with insulin using multiple daily injections (MDI) or pumps; type 2 diabetes (T2D) on MDI or insulin pumps; T2D on basal insulin only; and T2D not on insulin treatment. The T2D groups, regardless of treatment type, displayed the highest TIR and TITR values, associated with lowest glycemic variability measured as glucose coefficient of variation (CV; 23-30%). The T1D group showed the lowest TIR and TITR, associated with the highest CVs (36-38%). Overall, higher CV was associated with lower TIR and TITR for AG values below 180 and 140 mg/dL, respectively, with the reverse holding true for AG values above these thresholds. The discordance between AG and TIR/TITR was less pronounced in T2D compared with T1D, attributed to lower CV in the former group. It was also observed that TITR has advantages over TIR for assessing glycemia status and progress toward more stringent A1C, particularly when approaching normal glucose levels. The data detail how CV affects the AG relationship with TIR/TITR, which has implications for CGM interpretation. In many instances TITR, rather than TIR, may be preferable to employ once AG falls below 140 mg/dL and near-normal glucose levels are required clinically.


Asunto(s)
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Humanos , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Automonitorización de la Glucosa Sanguínea , Monitoreo Continuo de Glucosa , Glucemia , Insulina Regular Humana , Glucosa
13.
J Diabetes Sci Technol ; : 19322968241234072, 2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38439656

RESUMEN

BACKGROUND: Control-IQ technology version 1.5 allows for a wider range of weight and total daily insulin (TDI) entry, in addition to other changes to enhance performance for users with high basal rates. This study evaluated the safety and performance of the updated Control-IQ system for users with basal rates >3 units/h and high TDI in a multicenter, single arm, prospective study. METHODS: Adults with type 1 diabetes (T1D) using continuous subcutaneous insulin infusion (CSII) and at least one basal rate over 3 units/h (N = 34, mean age = 39.9 years, 41.2% female, diabetes duration = 21.8 years) used the t:slim X2 insulin pump with Control-IQ technology version 1.5 for 13 weeks. Primary outcome was safety events (severe hypoglycemia and diabetic ketoacidosis (DKA)). Central laboratory hemoglobin A1c (HbA1c) was measured at system initiation and 13 weeks. Participants continued using glucagon-like peptide-1 (GLP-1) receptor agonists, sodium-glucose transport protein 2 (SGLT-2) inhibitors, or other medications for glycemic control and/or weight loss if on a stable dose. RESULTS: All 34 participants completed the study. Fifteen participants used a basal rate >3 units/h for all 24 hours of the day. Nine participants used >300 units TDI on at least one day during the study. There were no severe hypoglycemia or DKA events. Time in range 70-180 mg/dL was 64.8% over the 13 weeks, with 1.0% time <70 mg/dL. Hemoglobin A1c decreased from 7.69% at baseline to 6.87% at 13 weeks (-0.82%, P < .001). CONCLUSIONS: Control-IQ technology version 1.5, with wider range of weight and TDI input and enhancements for users with high insulin requirements, was safe in individuals with T1D in this study.

15.
Diabetes Technol Ther ; 26(7): 467-477, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38315505

RESUMEN

Background: Time in range (TIR), time in tight range (TITR), and average glucose (AG) are used to adjust glycemic therapies in diabetes. However, TIR/TITR and AG can show a disconnect, which may create management difficulties. We aimed to understand the factors influencing the relationships between these glycemic markers. Materials and Methods: Real-world glucose data were collected from self-identified diabetes type 1 and type 2 diabetes (T1D and T2D) individuals using flash continuous glucose monitoring (FCGM). The effects of glycemic variability, assessed as glucose coefficient of variation (CV), on the relationship between AG and TIR/TITR were investigated together with the best-fit glucose distribution model that addresses these relationships. Results: Of 29,164 FCGM users (16,367 T1D, 11,061 T2D, and 1736 others), 38,259 glucose readings/individual were available. Comparing low and high CV tertiles, TIR at AG of 150 mg/dL varied from 80% ± 5.6% to 62% ± 6.8%, respectively (P < 0.001), while TITR at AG of 130 mg/dL varied from 65% ± 7.5% to 49% ± 7.0%, respectively (P < 0.001). In contrast, higher CV was associated with increased TIR and TITR at AG levels outside the upper limit of these ranges. Gamma distribution was superior to six other models at explaining AG and TIR/TITR interactions and demonstrated nonlinear interplay between these metrics. Conclusions: The gamma model accurately predicts interactions between CGM-derived glycemic metrics and reveals that glycemic variability can significantly influence the relationship between AG and TIR with opposing effects according to AG levels. Our findings potentially help with clinical diabetes management, particularly when AG and TIR appear mismatched.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Humanos , Glucemia/análisis , Femenino , Masculino , Diabetes Mellitus Tipo 2/sangre , Persona de Mediana Edad , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Adulto , Control Glucémico , Anciano , Hipoglucemiantes/uso terapéutico
16.
Diabetes Technol Ther ; 26(S3): 97-101, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38377320

RESUMEN

The use of automated insulin delivery (AID) has led to a decrease in the burden of diabetes, allowing for better sleep, decreased anxiety about hypoglycemia, and automatic corrections doses, and meal recognition algorithms have provided "forgiveness" for imprecise carbohydrate (CHO) entries and missed or late meal boluses. We provide a case report and review of the current literature assessing the effect of AID on the burden of meal bolus. The case also demonstrates how sensor and pump data provide insight into insulin bolus behavior, and access to integrated cloud-based data has allowed for virtual patient visits. Glucose sensor metrics provides time in range and time below range, and the sensor-derived glucose management indicator provides an assessment of the long-term risk of complications when a laboratory glycated hemoglobin is not available.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Humanos , Glucemia , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/complicaciones , Hipoglucemia/prevención & control , Hipoglucemia/etiología , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina/efectos adversos , Insulina Regular Humana/uso terapéutico
17.
Diabetes Care ; 47(6): 941-947, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38295397

RESUMEN

OBJECTIVE: To determine how diabetes technologies, including continuous glucose monitoring (CGM) and automated insulin delivery (AID) systems, impact glycemic metrics, prevalence of severe hypoglycemic events (SHEs), and impaired awareness of hypoglycemia (IAH) in people with type 1 diabetes in a real-world setting within the U.S. RESEARCH DESIGN AND METHODS: In this retrospective, observational study with cross-sectional elements, participants aged ≥18 years were enrolled from the T1D Exchange Registry/online community. Participants completed a one-time online survey describing glycemic metrics, SHEs, and IAH. The primary objective was to determine the proportions of participants who reported achieving glycemic targets (assessed according to self-reported hemoglobin A1c) and had SHEs and/or IAH. We performed additional subgroup analyses focusing on the impact of CGM and insulin delivery modality. RESULTS: A total of 2,074 individuals with type 1 diabetes were enrolled (mean ± SD age 43.0 ± 15.6 years and duration of type 1 diabetes 26.3 ± 15.3 years). The majority of participants (91.7%) were using CGM, with one-half (50.8%) incorporating AID. Despite high use of diabetes technologies, only 57.7% reported achieving glycemic targets (hemoglobin A1c <7%). SHEs and IAH still occurred, with ∼20% of respondents experiencing at least one SHE within the prior 12 months and 30.7% (95% CI 28.7, 32.7) reporting IAH, regardless of CGM or AID use. CONCLUSIONS: Despite use of advanced diabetes technologies, a high proportion of people with type 1 diabetes do not achieve glycemic targets and continue to experience SHEs and IAH, suggesting an ongoing need for improved treatment strategies.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1 , Hipoglucemia , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/complicaciones , Estudios Transversales , Femenino , Adulto , Masculino , Hipoglucemia/epidemiología , Persona de Mediana Edad , Estudios Retrospectivos , Sistemas de Infusión de Insulina , Insulina/uso terapéutico , Insulina/administración & dosificación , Glucemia/metabolismo , Hemoglobina Glucada/metabolismo , Hipoglucemiantes/uso terapéutico , Hipoglucemiantes/administración & dosificación
18.
Diabetes Care ; 47(4): 571-579, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38190619

RESUMEN

OBJECTIVE: To compare the effects of insulin sensitivity and ß-cell function over time on HbA1c and durability of glycemic control in response to dual therapy. RESEARCH DESIGN AND METHODS: GRADE participants were randomized to glimepiride (n = 1,254), liraglutide (n = 1,262), or sitagliptin (n = 1,268) added to baseline metformin and followed for mean ± SD 5.0 ± 1.3 years, with HbA1c assessed quarterly and oral glucose tolerance tests at baseline, 1, 3, and 5 years. We related time-varying insulin sensitivity (HOMA 2 of insulin sensitivity [HOMA2-%S]) and early (0-30 min) and total (0-120 min) C-peptide (CP) responses to changes in HbA1c and glycemic failure (primary outcome HbA1c ≥7% [53 mmol/mol] and secondary outcome HbA1c >7.5% [58 mmol/mol]) and examined differential treatment responses. RESULTS: Higher HOMA2-%S was associated with greater initial HbA1c lowering (3 months) but not subsequent HbA1c rise. Greater CP responses were associated with a greater initial treatment response and slower subsequent HbA1c rise. Higher HOMA2-%S and CP responses were each associated with lower risk of primary and secondary outcomes. These associations differed by treatment. In the sitagliptin group, HOMA2-%S and CP responses had greater impact on initial HbA1c reduction (test of heterogeneity, P = 0.009 HOMA2-%S, P = 0.018 early CP, P = 0.001 total CP) and risk of primary outcome (P = 0.005 HOMA2-%S, P = 0.11 early CP, P = 0.025 total CP) but lesser impact on HbA1c rise (P = 0.175 HOMA2-%S, P = 0.006 early CP, P < 0.001 total CP) in comparisons with the glimepiride and liraglutide groups. There were no differential treatment effects on secondary outcome. CONCLUSIONS: Insulin sensitivity and ß-cell function affected treatment outcomes irrespective of drug assignment, with greater impact in the sitagliptin group on initial (short-term) HbA1c response in comparison with the glimepiride and liraglutide groups.


Asunto(s)
Diabetes Mellitus Tipo 2 , Resistencia a la Insulina , Metformina , Compuestos de Sulfonilurea , Humanos , Hipoglucemiantes/uso terapéutico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Liraglutida/uso terapéutico , Hemoglobina Glucada , Metformina/uso terapéutico , Fosfato de Sitagliptina/uso terapéutico , Resultado del Tratamiento , Glucemia , Quimioterapia Combinada
19.
Diabetes Technol Ther ; 26(3): 151-155, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37870460

RESUMEN

Objective: To evaluate the relationship between continuous glucose monitoring (CGM)-measured time-in-range 70-180 mg/dL (TIR) and time-in-tight-range 70-140 mg/dL (TITR). Methods: TIR and TITR were calculated from CGM data collected using blinded or unblinded Dexcom sensors from 9 studies with 912 participants with type 1 diabetes (T1D) and 2 studies with 184 participants with type 2 diabetes (T2D). The TIR-TITR relationship was assessed overall and stratified by coefficient of variation (CV) and by time below range <70 mg/dL (TBR). Results: The correlation between TIR and TITR was 0.94. TITR was higher for a given TIR for T2D compared with T1D. However, after adjusting for the differences in CV or TBR, both of which were higher with T1D than T2D, the differences were minimized. The TIR-TITR relationship was nonlinear, with a higher ratio of TITR:TIR observed as TIR increased ranging from 0.42 when TIR was 20% to 0.66 when TIR was 80%. Similarly, as TITR increased, the ratio of TIR:TITR decreased, varying from 2.6 with TITR of 10% to 1.3 for TITR of 70%. The TIR-TITR relationship varied according to CV and TBR, such that the higher the CV or higher the amount of TBR the greater was TITR for a given TIR. Conclusions: TIR and TITR are highly correlated, although the relationship is nonlinear. With knowledge of TIR, TITR can be estimated with reasonable precision.


Asunto(s)
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Glucemia , Automonitorización de la Glucosa Sanguínea , Monitoreo Continuo de Glucosa
20.
Diabetes Technol Ther ; 26(1): 11-23, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37850941

RESUMEN

Background: The Omnipod® 5 Automated Insulin Delivery (AID) System was shown to be safe and effective following 3 months of use in people with type 1 diabetes (T1D); however, data on the durability of these results are limited. This study evaluated the long-term safety and effectiveness of Omnipod 5 use in people with T1D during up to 2 years of use. Materials and Methods: After a 3-month single-arm, multicenter, pivotal trial in children (6-13.9 years) and adolescents/adults (14-70 years), participants could continue system use in an extension phase. HbA1c was measured every 3 months for up to 15 months; continuous glucose monitor metrics were collected for up to 2 years. Results: Participants (N = 224) completed median (interquartile range) 22.3 (21.7, 22.7) months of AID. HbA1c was reduced in the pivotal trial from 7.7% ± 0.9% in children and 7.2% ± 0.9% in adolescents/adults to 7.0% ± 0.6% and 6.8% ± 0.7%, respectively, (P < 0.0001), and was maintained at 7.2% ± 0.7% and 6.9% ± 0.6% after 15 months (P < 0.0001 from baseline). Time in target range (70-180 mg/dL) increased from 52.4% ± 15.6% in children and 63.6% ± 16.5% in adolescents/adults at baseline to 67.9% ± 8.0% and 73.8% ± 10.8%, respectively, during the pivotal trial (P < 0.0001) and was maintained at 65.9% ± 8.9% and 72.9% ± 11.3% during the extension (P < 0.0001 from baseline). One episode of diabetic ketoacidosis and seven episodes of severe hypoglycemia occurred during the extension. Children and adolescents/adults spent median 96.1% and 96.3% of time in Automated Mode, respectively. Conclusion: Our study supports that long-term use of the Omnipod 5 AID System can safely maintain improvements in glycemic outcomes for up to 2 years of use in people with T1D. Clinical Trials Registration Number: NCT04196140.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Niño , Humanos , Adolescente , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Hemoglobina Glucada , Sistemas de Infusión de Insulina , Glucemia , Automonitorización de la Glucosa Sanguínea
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA