Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Appl Radiat Isot ; 205: 111171, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38181577

RESUMEN

Absolute gamma-ray emission intensities for 36 characteristic gamma rays from the decay of 224Ra, 212Pb, and their progeny were determined by measuring sources calibrated for activity by means of primary methods based on well-defined high-purity germanium (HPGe) detectors at both NIST and NPL. Results from the two laboratories agree with recent data evaluations, except for gamma rays with low emission intensities. The decay schemes have been re-balanced based on the new results. In addition, the half-life for 212Pb was measured using several HPGe detectors, ionization chambers, and a well-type NaI(Tl) detector.

2.
Phys Rev Lett ; 131(2): 021802, 2023 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-37505961

RESUMEN

This Letter reports one of the most precise measurements to date of the antineutrino spectrum from a purely ^{235}U-fueled reactor, made with the final dataset from the PROSPECT-I detector at the High Flux Isotope Reactor. By extracting information from previously unused detector segments, this analysis effectively doubles the statistics of the previous PROSPECT measurement. The reconstructed energy spectrum is unfolded into antineutrino energy and compared with both the Huber-Mueller model and a spectrum from a commercial reactor burning multiple fuel isotopes. A local excess over the model is observed in the 5-7 MeV energy region. Comparison of the PROSPECT results with those from commercial reactors provides new constraints on the origin of this excess, disfavoring at 2.0 and 3.7 standard deviations the hypotheses that antineutrinos from ^{235}U are solely responsible and noncontributors to the excess observed at commercial reactors, respectively.

3.
Phys Rev Lett ; 128(8): 081801, 2022 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-35275656

RESUMEN

A joint determination of the reactor antineutrino spectra resulting from the fission of ^{235}U and ^{239}Pu has been carried out by the Daya Bay and PROSPECT Collaborations. This Letter reports the level of consistency of ^{235}U spectrum measurements from the two experiments and presents new results from a joint analysis of both data sets. The measurements are found to be consistent. The combined analysis reduces the degeneracy between the dominant ^{235}U and ^{239}Pu isotopes and improves the uncertainty of the ^{235}U spectral shape to about 3%. The ^{235}U and ^{239}Pu antineutrino energy spectra are unfolded from the jointly deconvolved reactor spectra using the Wiener-SVD unfolding method, providing a data-based reference for other reactor antineutrino experiments and other applications. This is the first measurement of the ^{235}U and ^{239}Pu spectra based on the combination of experiments at low- and highly enriched uranium reactors.

4.
Phys Rev Lett ; 128(8): 081802, 2022 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-35275665

RESUMEN

The PROSPECT and STEREO collaborations present a combined measurement of the pure ^{235}U antineutrino spectrum, without site specific corrections or detector-dependent effects. The spectral measurements of the two highest precision experiments at research reactors are found to be compatible with χ^{2}/ndf=24.1/21, allowing a joint unfolding of the prompt energy measurements into antineutrino energy. This ν[over ¯]_{e} energy spectrum is provided to the community, and an excess of events relative to the Huber model is found in the 5-6 MeV region. When a Gaussian bump is fitted to the excess, the data-model χ^{2} value is improved, corresponding to a 2.4σ significance.

5.
Appl Radiat Isot ; 167: 109455, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33039762

RESUMEN

The National Institute of Standards and Technology (NIST) performed new standardization measurements for 124I. As part of this work the absolute photon emission intensity for the main gamma-rays of 124I were determined using several high-purity germanium (HPGe) detectors. In addition, the half-life for 124I was also determined using an HPGe detector. Ionization chamber measurements were performed for additional sources, but it was not possible to obtain a precise half-life value.

6.
Phys Rev C ; 1012020.
Artículo en Inglés | MEDLINE | ID: mdl-33336123

RESUMEN

Reactor neutrino experiments have seen major improvements in precision in recent years. With the experimental uncertainties becoming lower than those from theory, carefully considering all sources of ν ¯ e is important when making theoretical predictions. One source of ν ¯ e that is often neglected arises from the irradiation of the nonfuel materials in reactors. The ν ¯ e rates and energies from these sources vary widely based on the reactor type, configuration, and sampling stage during the reactor cycle and have to be carefully considered for each experiment independently. In this article, we present a formalism for selecting the possible ν ¯ e sources arising from the neutron captures on reactor and target materials. We apply this formalism to the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory, the ν ¯ e source for the the Precision Reactor Oscillation and Spectrum Measurement (PROSPECT) experiment. Overall, we observe that the nonfuel ν ¯ e contributions from HFIR to PROSPECT amount to 1% above the inverse beta decay threshold with a maximum contribution of 9% in the 1.8-2.0 MeV range. Nonfuel contributions can be particularly high for research reactors like HFIR because of the choice of structural and reflector material in addition to the intentional irradiation of target material for isotope production. We show that typical commercial pressurized water reactors fueled with low-enriched uranium will have significantly smaller nonfuel ν ¯ e contribution.

7.
Artículo en Inglés | MEDLINE | ID: mdl-33093736

RESUMEN

Neutral particle detection in high-background environments is greatly aided by the ability to easily load 6Li into liquid scintillators. We describe a readily available and inexpensive liquid scintillation cocktail stably loaded with a Li mass fraction up to 1 %. Compositions that give thermodynamically stable microemulsions (reverse-micellar systems) were explored, using a Compton spectrum quenching technique to distinguish these from unstable emulsions. Scintillation light yield and transmittance were characterized. Pulse shape discrimination (PSD) was measured using a 252Cf source, showing that electron-like and proton-like recoil events are well-resolved even for Li loading up to 1 %, providing a means of background suppression in neutron/neutrino detectors. While samples in this work were prepared with nat Li (7.59 % 6Li), the neutron capture peak was clearly visible in the PSD spectrum; this implies that while extremely high capture efficiency could be achieved with 6Li-enriched material, a very inexpensive neutron-sensitive detector can be prepared with nat Li.

8.
Appl Radiat Isot ; 163: 109216, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32561054

RESUMEN

Re-entrant ionization chambers (ICs) are essential to radionuclide metrology and nuclear medicine for maintaining standards and measuring half-lives. The requirements of top-level metrology demand that systems must be precise and stable to 0.1 % over many years, and linear from 10-14 A to 10-8 A. Thus, laboratories depend on bespoke current measurement systems and often rely on sealed sources to generate reference currents. To maintain and improve present capabilities, metrologists need to overcome two looming challenges: ageing electronics and decreasing availability of sealed sources. Possible solutions using Ultrastable Low-Noise Current Amplifiers (ULCAs), resistive-feedback electrometers, and (quantum) single-electron pumps are reviewed. Broader discussions of IC design and methodology are discussed. ULCAs show promise and resistive-feedback systems which take advantage of standard resistor calibrations offer an alternative.

9.
Appl Radiat Isot ; 156: 108943, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31683089

RESUMEN

The National Institute of Standards and Technology (NIST) measured the internal pair production branching ratio of 90Y using two sources and four high purity germanium (HPGe) detectors to detect the resulting annihilation radiation. The internal pair production branching ratio determined from these measurements, (32.0 ±â€¯1.5) × 10-6 (k = 1), agrees within 1 standard uncertainty with the recommended value of (32.6 ±â€¯0.7) × 10-6 (k = 1) from the DDEP database.

10.
Appl Radiat Isot ; 154: 108849, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31465950

RESUMEN

A solution of 124I was standardized for activity by 4πß(LS)-γ(NaI) live-timed anticoincidence (LTAC) counting, with confirmatory measurements by triple-to-double coincidence ratio (TDCR) and CIEMAT-NIST efficiency tracing (CNET) liquid scintillation counting. The LTAC-based standard was shown to be in agreement (within k = 1 uncertainties) with previous measurements at NIST and elsewhere. Calibration settings for radionuclide calibrators were determined and a discrepancy with literature values, partially due to a calibration methodology dependent upon an erroneous setting for 18F, was identified and explained.

11.
Phys Rev Lett ; 122(25): 251801, 2019 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-31347897

RESUMEN

This Letter reports the first measurement of the ^{235}U ν[over ¯]_{e} energy spectrum by PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, operating 7.9 m from the 85 MW_{th} highly enriched uranium (HEU) High Flux Isotope Reactor. With a surface-based, segmented detector, PROSPECT has observed 31678±304(stat) ν[over ¯]_{e}-induced inverse beta decays, the largest sample from HEU fission to date, 99% of which are attributed to ^{235}U. Despite broad agreement, comparison of the Huber ^{235}U model to the measured spectrum produces a χ^{2}/ndf=51.4/31, driven primarily by deviations in two localized energy regions. The measured ^{235}U spectrum shape is consistent with a deviation relative to prediction equal in size to that observed at low-enriched uranium power reactors in the ν[over ¯]_{e} energy region of 5-7 MeV.

12.
Appl Radiat Isot ; 139: 266-273, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29879531

RESUMEN

The complex decay scheme that makes 64Cu promising as both an imaging and therapeutic agent in medicine also makes the absolute measurement of its activity challenging. The National Institute of Standards and Technology (NIST) has completed a primary activity standardization of a 64CuCl2 solution using the 4πß(LS)-γ(NaI) live-timed anticoincidence (LTAC) counting method with a combined standard uncertainty of 0.51 %. Two liquid scintillation (LS) counting methods were employed for confirmatory measurements. Secondary measurements were made by high-purity germanium detectors, pressurized ionization chambers (IC), and a well-type NaI(Tl) counter. Agreement between the LTAC-based standard and standards from other laboratories was established via IC calibration factors. Poor agreement between methods and with theoretical IC responses may indicate a need for improved ß+/- branching probabilities and a better treatment of ß+/- spectra.

13.
Phys Rev Lett ; 121(25): 251802, 2018 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-30608854

RESUMEN

This Letter reports the first scientific results from the observation of antineutrinos emitted by fission products of ^{235}U at the High Flux Isotope Reactor. PROSPECT, the Precision Reactor Oscillation and Spectrum Experiment, consists of a segmented 4 ton ^{6}Li-doped liquid scintillator detector covering a baseline range of 7-9 m from the reactor and operating under less than 1 m water equivalent overburden. Data collected during 33 live days of reactor operation at a nominal power of 85 MW yield a detection of 25 461±283 (stat) inverse beta decays. Observation of reactor antineutrinos can be achieved in PROSPECT at 5σ statistical significance within 2 h of on-surface reactor-on data taking. A reactor model independent analysis of the inverse beta decay prompt energy spectrum as a function of baseline constrains significant portions of the previously allowed sterile neutrino oscillation parameter space at 95% confidence level and disfavors the best fit of the reactor antineutrino anomaly at 2.2σ confidence level.

14.
Appl Radiat Isot ; 134: 68-73, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28974328

RESUMEN

Using uniform cylindrical phantoms containing calibrated solutions of 18F and 64Cu, we evaluated for the first time the accuracy with which the activity concentration of 64Cu can be quantified on an absolute basis using Positron Emission Tomography (with X-ray Computed Tomography, PET-CT). The scanner was first calibrated for 18F using the manufacturer's calibration protocol and a phantom with an activity concentration value traceable to the U.S. National standard. By using a similarly calibrated 18F solution phantom, we were able to determine a correction factor that can be applied to the 64Cu imaging data that gave a result that is consistent with 100% recovery with a combined standard uncertainty of 2%. We also demonstrate how a calibrated, solid phantom containing 68Ge as a long-lived 18F surrogate can be used to monitor and transfer the correction factor to other studies.

15.
Appl Radiat Isot ; 134: 385-390, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29248210

RESUMEN

An international key comparison, identifier CCRI(II)-K2.Ge-68, has been performed. The National Institute of Standards and Technology (NIST) served as the pilot laboratory, distributing aliquots of a 68Ge/68Ga solution. Results for the activity concentration, CA, of 68Ge at a reference date of 12h00 UTC 14 November 2014 were submitted by 17 laboratories, encompassing many variants of coincidence methods and liquid-scintillation counting methods. The first use of 4π(Cherenkov)ß-γ coincidence and anticoincidence methods in an international comparison is reported. One participant reported results by secondary methods only. Two results, both utilizing pure liquid-scintillation methods, were identified as outliers. Evaluation using the Power-Moderated Mean method results in a proposed Comparison Reference Value (CRV) of 621.7(11)kBqg-1, based on 14 results. The degrees of equivalence and their associated uncertainties are evaluated for each participant. Several participants submitted 3.6mL ampoules to the BIPM to link the comparison to the International Reference System (SIR) which may lead to the evaluation of a Key Comparison Reference Value and associated degrees of equivalence.

16.
Appl Radiat Isot ; 129: 6-12, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28783614

RESUMEN

The National Institute of Standards and Technology (NIST) performed new standardization measurements for 64Cu. As part of this work the photon emission probability for the main gamma-ray line and the half-life were determined using several high-purity germanium (HPGe) detectors. Half-life determinations were also carried out with a NaI(Tl) well counter and two pressurized ionization chambers.

17.
Appl Radiat Isot ; 112: 38-49, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-27010939

RESUMEN

A new National Institute of Standards and Technology (NIST) tritiated-water ((3)H-labeled oxidane) standard was prepared and calibrated. It is the 17th in a series of linked standards since 1954 and will be disseminated as Standard Reference Material® SRM 4927G, having a massic activity of 544.2kBqg(-1), with an expanded (k=2) relative standard uncertainty of 0.96%, at a Reference Time of 1200 EST, 1 May 2015. The calibration is based on relative liquid scintillation (LS) measurements using quench-varied efficiency tracing with two previous 1999 issues, viz., SRM 4927F and 4926E. Measurement comparisons were also made with respect to a 1994 tritiated-water French national standard and to a tritiated-water solution measured by 19 laboratories as part of an international measurement comparison organized by the Bureau International des Poids et Mesures (BIPM) in 2009. Confirmatory measurements for the massic activity of both SRM 4927F and 4927G by a triple-to-double coincidence ratio (TDCR) technique were also made.

18.
Appl Radiat Isot ; 109: 214-216, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26671789

RESUMEN

Tests for chemical stability were carried out on carrier-added (68)Ge solutions prepared and calibrated in 2007 and 2011 to evaluate the suitability of the specific composition as a potential Standard Reference Material. Massic count rates of the stored solutions were measured using a NaI(Tl) well counter before and after gravimetric transfers. The present activity concentration of the 2007 solution was also measured using live-timed anticoincidence counting (LTAC) and compared to the 2007 calibrated value. The well counter data indicated no change in massic count rate to within uncertainties for either solution. The LTAC measurements gave a difference of -0.49% in the activity concentration 2007 solution over 7 years. However, the uncertainty in the decay correction over that time, due to the uncertainty in the (68)Ge half-life, accounted for the majority (0.67% out of 0.83%) of the standard uncertainty on the activity concentration. The results indicate that these carrier-added solutions are stable with regard to potential activity losses over several half-lives of (68)Ge.

19.
Phys Lett B ; 761: 281-286, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-28057978

RESUMEN

The hypothesis that proximity to the Sun causes variation of decay constants at permille level has been tested and disproved. Repeated activity measurements of mono-radionuclide sources were performed over periods from 200 days up to four decades at 14 laboratories across the globe. Residuals from the exponential nuclear decay curves were inspected for annual oscillations. Systematic deviations from a purely exponential decay curve differ from one data set to another and are attributable to instabilities in the instrumentation and measurement conditions. The most stable activity measurements of alpha, beta-minus, electron capture, and beta-plus decaying sources set an upper limit of 0.0006% to 0.008% to the amplitude of annual oscillations in the decay rate. Oscillations in phase with Earth's orbital distance to the Sun could not be observed within a 10-6 to 10-5 range of precision. There are also no apparent modulations over periods of weeks or months. Consequently, there is no indication of a natural impediment against sub-permille accuracy in half-life determinations, renormalisation of activity to a distant reference date, application of nuclear dating for archaeology, geo- and cosmochronology, nor in establishing the SI unit becquerel and seeking international equivalence of activity standards.

20.
Appl Radiat Isot ; 109: 250-253, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26653213

RESUMEN

Using NIST-calibrated solutions of (131)Ba and (131)I in the 5mL NIST ampoule geometry, measurements were made in three NIST-maintained Capintec activity calibrators and the NIST Vinten 671 ionization chamber to evaluate the suitability of using (133)Ba as a calibration surrogate for (131)I. For the Capintec calibrators, the (133)Ba response was a factor of about 300% higher than that of the same amount of (131)I. For the Vinten 671, the Ba-133 response was about 7% higher than that of (131)I. These results demonstrate that (133)Ba is a poor surrogate for (131)I. New calibration factors for these radionuclides in the ampoule geometry for the Vinten 671 and Capintec activity calibrators were also determined.


Asunto(s)
Radioisótopos de Bario/análisis , Radioisótopos de Bario/normas , Calibración/normas , Radioisótopos de Yodo/análisis , Radioisótopos de Yodo/normas , Dosímetros de Radiación/normas , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...