Resultados 1 - 20 de 39
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38736246

RESUMEN

BACKGROUND: Stent implantation has become standard of care in older children and adults for treatment of branch pulmonary artery stenosis (BPAS) and coarctation aorta (CoAo). There are no stents approved or available for infants that have the potential to be dilated to adult diameters. The Minima stent was designed to fulfill this unmet need. METHODS: Multicenter, prospective, nonrandomized early feasibility study evaluating safety and effectiveness of the Minima stent for treatment of BPAS and CoAo. Primary endpoints included: (1) successful deployment across lesion, (2) stenosis relief defined by an increase in angiographic diameter of >50% and (3) freedom from stent explant, embolization or migration at 30 days and 6 months. RESULTS: Between 2/2022 and 5/2022, 10 pts underwent Minima stent implantation with a median age and weight of 9 months (4-43 months) and 7.6 kg (5.1-16.9 kg). Procedural success and predefined stenosis relief was achieved in all cases (CoAo [n = 4], BPAS [n = 6]). Adverse events occurred in 3 pts: transient diminished lower extremity pulse (n = 2), distal stent on-balloon displacement successfully managed in the catheterization suite (n = 1). There were no deaths or major adverse events. All patients were free from stent explant and migration at 30 days and 6 months with no evidence for significant restenosis at latest follow-up. CONCLUSIONS: Implantation of the Renata Minima stent was safe and effective for the treatment of BPAS and CoAo in this small cohort of infants and young children during early follow-up. Based on these early results, an expanded study with longer follow-up is warranted.

2.
Circ Cardiovasc Interv ; : e013729, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38666384

RESUMEN

BACKGROUND: Transverse aortic arch obstruction is a challenging lesion for which stent implantation provides a potentially important alternate therapy. The objectives were to evaluate the technical, procedural, and medium-to-long-term clinical outcomes of percutaneous stent implantation of transverse aortic arch obstruction. METHODS: This is a retrospective, multicenter study of transverse aortic arch stent implantation. Univariable and multivariable analyses were performed. RESULTS: Index catheterization included 187 stent implants in 146 patients. The median age is 14.3 years (interquartile range, 9.3-19), weight is 53 kg (30-69), and follow-up is 53 months (12-120). The most common stent design was open cell (n=90, 48%). Stents overlapped 142 arch vessels (37 carotid arteries) in 118 (81%) cases. Technical and procedural success rates were 100% and 88%, respectively. Lower weight (P=0.018), body surface area (P=0.013), and minimum-to-descending aortic diameter ratio (P<0.001) were associated with higher baseline aortic gradient. The residual gradient was inversely associated with implant and final dilation diameters (P<0.001). The combined incidence of aortic injury and stent-related complications was 14%. There were no reports of abnormal brain scans or stroke. Blood pressure cuff gradient, echocardiographic arch velocity, and hypertension rates improved within 1-year follow-up with increased antihypertensive medication use. Reintervention was reported in 60 (41%) patients at a median of 84 (22-148) months to first reintervention. On multivariable logistic regression, residual aortic gradient >10 mm Hg was associated with increased odds of reintervention at all time points when controlling for each final dilation diameter, weight, and minimum-to-descending aortic diameter ratio. CONCLUSIONS: Transverse aortic arch stent implantation has high rates of technical, procedural, and medium-to-long-term clinical success. Aortic gradient >10 mm Hg is associated with increased odds of reintervention at 1-year and most recent follow-ups. Open cell stent design was frequently used for its advantages in conformability, perfusion of arch vessels, low fracture rate, and the ability to perform effective angioplasty of side cells.

3.
Pediatr Cardiol ; 44(1): 132-140, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36029321

RESUMEN

The aim of the study was to determine the variables associated with high-quality (HQ) versus low-quality (LQ) three-dimensional rotational angiography (3DRA) and create guides for optimization of approach to 3DRA in congenital cardiac catheterization (CCC). CCC has adopted 3DRA as a mainstay, but there has not been systematic analysis of approach to and factors associated with HQ 3DRA. This was a single-center, retrospective study of 3DRAs using Canon Infinix-I platform. Reconstructions were graded by 3 interventionalists. Quality was dichotomized into HQ and LQ. Univariable analyses and multivariable logistic regression models were performed. From 8/2016 to 12/2018, 208 3DRAs were performed in 195 CCCs; median age 7 years (2, 16), weight 23 kg (12, 57). The majority of 3DRAs were performed in patients with biventricular physiology (N = 137, 66%) and in pulsatile sites (N = 144, 69%). HQ 3DRA (N = 182, 88%) was associated with greater total injection volume [2.20 mL/kg (1.44, 3.29) vs. 1.62 mL/kg (1.10, 1.98), p = 0.005] and more dilute contrast solution [60% (50, 100) vs. 100% (60, 100), p = 0.007], but not with contrast volume administered (p = 0.2) on univariable analysis. On multivariable logistic regression, HQ 3DRA was significantly associated with patient weight [OR 0.97 (95% CI (0.94, 0.99), p = 0.018], total injection volume [OR 1.04 (95% CI 1.01, 1.07) p = 0.011], and percent contrast solution [OR 0.97 (95% CI 0.95, 1.00), p = 0.022]. These data resulted in creation of scatter plots and a novel 3DRA Nomogram for estimating the probability of HQ 3DRA. This is the first study to create evidence-based contrast dose guides and nomogram for 3DRA in CCC. HQ 3DRA was associated with lower weight, higher total injection volumes, and more dilute contrast solution.


Asunto(s)
Imagenología Tridimensional , Procedimientos de Cirugía Plástica , Humanos , Niño , Estudios Retrospectivos , Imagenología Tridimensional/métodos , Angiografía/métodos , Cateterismo Cardíaco/métodos
4.
Commun Med (Lond) ; 2: 3, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35603301

RESUMEN

Background: Tissue-engineered vascular grafts (TEVGs) have the potential to advance the surgical management of infants and children requiring congenital heart surgery by creating functional vascular conduits with growth capacity. Methods: Herein, we used an integrative computational-experimental approach to elucidate the natural history of neovessel formation in a large animal preclinical model; combining an in vitro accelerated degradation study with mechanical testing, large animal implantation studies with in vivo imaging and histology, and data-informed computational growth and remodeling models. Results: Our findings demonstrate that the structural integrity of the polymeric scaffold is lost over the first 26 weeks in vivo, while polymeric fragments persist for up to 52 weeks. Our models predict that early neotissue accumulation is driven primarily by inflammatory processes in response to the implanted polymeric scaffold, but that turnover becomes progressively mechano-mediated as the scaffold degrades. Using a lamb model, we confirm that early neotissue formation results primarily from the foreign body reaction induced by the scaffold, resulting in an early period of dynamic remodeling characterized by transient TEVG narrowing. As the scaffold degrades, mechano-mediated neotissue remodeling becomes dominant around 26 weeks. After the scaffold degrades completely, the resulting neovessel undergoes growth and remodeling that mimicks native vessel behavior, including biological growth capacity, further supported by fluid-structure interaction simulations providing detailed hemodynamic and wall stress information. Conclusions: These findings provide insights into TEVG remodeling, and have important implications for clinical use and future development of TEVGs for children with congenital heart disease.

5.
Clin Perinatol ; 49(1): 149-166, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35209997

RESUMEN

Percutaneous-based patent ductus arteriosus closure is technically feasible among infants less than 1.5 kg. However, marked heterogeneity in the type and nature of adverse events obscures current safety profile assessments. Although data on the risks of postdevice closure syndrome remain promising, a lack of comparative trials of surgical ductal ligation and inconsistent surveillance across published studies obscure confidence in present estimates of safety and efficacy. To minimize risk and yield the greatest benefits, clinical studies of patent ductus arteriosus treatment should consider incorporating more robust assessments to ensure that infants at greatest risk for adverse ductal consequences are included.


Asunto(s)
Conducto Arterioso Permeable , Conducto Arterioso Permeable/cirugía , Humanos , Lactante , Recién Nacido , Recien Nacido Prematuro , Ligadura , Resultado del Tratamiento
6.
Pediatr Cardiol ; 43(5): 986-994, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34981140

RESUMEN

To date, there has been limited investigation of bioabsorbable atrial septal defect (ASD) or patent foramen ovale (PFO) closure devices using clinically relevant large animal models. The purpose of this study is to explore the function and safety of a bioabsorbable ASD occluder (BAO) system for PFO and/or secundum ASD transcatheter closure. Using a sheep model, the intra-atrial septum was evaluated by intracardiac echo (ICE). If a PFO was not present, atrial communication was created via transseptal puncture. Device implantation across the intra-atrial communication was performed with fluoroscopic and ICE guidance. Our 1st generation device consisted of a main structure of thin Poly(L-lactide-co-epsilon-caprolactone) (PLCL) fibers, and an internal Poly glycolic acid (PGA) fabric. Four procedures validated procedure feasibility. Subsequently, device design was modified for improved transcatheter delivery. The 2nd generation device has a two-layered structure and was implanted in six sheep. Results showed procedural success in 9/10 (90%) animals. With deployment, the 1st generation device did not reform into its original disk shape and did not conform nicely along the atrial septum. The 2nd generation device was implanted in six animals, 3 out of 6 survived out to 1 year. At 1 year post implantation, ICE confirmed no residual shunting. By necropsy, biomaterials had partially degraded, and histology of explanted samples revealed significant device endothelialization and biomaterial replacement with a collagen layer. Our results demonstrate that our modified 2nd generation BAO can be deployed via minimally invasive percutaneous transcatheter techniques. The BAO partially degrades over 1 year and is replaced by host native tissues. Future studies are needed prior to clinical trials.


Asunto(s)
Foramen Oval Permeable , Defectos del Tabique Interatrial , Dispositivo Oclusor Septal , Implantes Absorbibles , Animales , Cateterismo Cardíaco/métodos , Estudios de Seguimiento , Foramen Oval Permeable/cirugía , Atrios Cardíacos , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/cirugía , Humanos , Ovinos , Resultado del Tratamiento
7.
Circ Cardiovasc Interv ; 15(1): e010852, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34930015

RESUMEN

BACKGROUND: The Melody valve was developed to extend the useful life of previously implanted right ventricular outflow tract (RVOT) conduits or bioprosthetic pulmonary valves, while preserving RV function and reducing the lifetime burden of surgery for patients with complex congenital heart disease. METHODS: Enrollment for the US Investigational Device Exemption study of the Melody valve began in 2007. Extended follow-up was completed in 2020. The primary outcome was freedom from transcatheter pulmonary valve (TPV) dysfunction (freedom from reoperation, reintervention, moderate or severe pulmonary regurgitation, and/or mean RVOT gradient >40 mm Hg). Secondary end points included stent fracture, catheter reintervention, surgical conduit replacement, and death. RESULTS: One hundred seventy-one subjects with RVOT conduit or bioprosthetic pulmonary valve dysfunction were enrolled. One hundred fifty underwent Melody TPV replacement. Median age was 19 years (Q1-Q3: 15-26). Median discharge mean RVOT Doppler gradient was 17 mm Hg (Q1-Q3: 12-22). The 149 patients implanted >24 hours were followed for a median of 8.4 years (Q1-Q3: 5.4-10.1). At 10 years, estimated freedom from mortality was 90%, from reoperation 79%, and from any reintervention 60%. Ten-year freedom from TPV dysfunction was 53% and was significantly shorter in children than in adults. Estimated freedom from TPV-related endocarditis was 81% at 10 years (95% CI, 69%-89%), with an annualized rate of 2.0% per patient-year. CONCLUSIONS: Ten-year outcomes from the Melody Investigational Device Exemption trial affirm the benefits of Melody TPV replacement in the lifetime management of patients with RVOT conduits and bioprosthetic pulmonary valves by providing sustained symptomatic and hemodynamic improvement in the majority of patients. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT00740870.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Adolescente , Adulto , Humanos , Diseño de Prótesis , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
8.
Catheter Cardiovasc Interv ; 98(1): 128-136, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-33909945

RESUMEN

BACKGROUND: Covered stent correction of sinus venosus ASDs (SVASD) is a relatively new technique. Challenges include anchoring a sufficiently long stent in a nonstenotic superior vena cava (SVC) and expanding the stent at the wider SVC-RA junction without obstructing the anomalous right upper pulmonary vein (RUPV). The 10-zig covered Cheatham-platinum (CCP) stent has the advantage of being available in lengths of 5-11 cm and dilatable to 34 mm in diameter. METHODS: An international registry reviewed the outcomes of 10-zig CCP stents in 75 patients aged 11.4-75.9 years (median 45.4) from March 2016. Additional stents were used to anchor the stent in the SVC or close residual shunts in 33/75. An additional stent was placed in 4/5 (80%) with 5/5.5 cm CCPs, 18/29 (62%) with 6 cm CCPs, 5/18 (28%) with 7 cm CCPs, 5/22 (23%) with 7.5/8 cm CCPs and 0/1 with an 11 cm CCP. A "protective" balloon catheter was inflated in the RUPV in 17. RESULTS: Early stent embolization in two patients required surgical removal and defect repair and tamponade was drained in one patient. The CT at 3 months showed occlusion of the RUPV in one patient. Follow up is from 2 months to 5.1 years (median 1.8 years). QP:QS has reduced from 2.5 ± 0.5 to 1.2 ± 0.36 (p < .001) and RVEDVi from 149.1 ± 35.4 to 95.6 ± 21.43 ml/m2 (p < .001). CONCLUSIONS: Ten-zig CCPs of 7-8 cm appear to provide reliable SVASD closure with a low requirement for additional stents. Careful selection of patients and meticulous attention to detail is required to avoid complications.


Asunto(s)
Defectos del Tabique Interatrial , Platino (Metal) , Humanos , Sistema de Registros , Stents , Resultado del Tratamiento , Vena Cava Superior
9.
Circ Cardiovasc Interv ; 14(2): e009399, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33544625

RESUMEN

BACKGROUND: Stent implantation (SI) is more effective than balloon angioplasty for the treatment of coarctation of the aorta (CoA). Due to technical factors, balloon angioplasty is more commonly performed in small patients. We sought to evaluate outcomes of percutaneous adult sized SI for the treatment of CoA in small patients. METHODS: A single-center retrospective review of all patients ≤20 kg who underwent percutaneous adult sized SI for native or recurrent CoA from 2004 to 2015 was performed. RESULTS: Thirty-nine patients (20 patients ≤10 kg) were identified, with 28 (71.8%) having recurrent CoA and 22 (56.4%) previously failed balloon angioplasty. At the time of SI, the median (range) patient age and weight were 1.1 (0.3-7.9) years and 10 (5.5-20.4) kg, respectively. SI resulted in significant improvements in the median gradient (26 mm Hg [interquartile range (IQR), 18-42] to 0 mm Hg [IQR, 0-2]; P< 0.05) and median minimum diameter (3.6 mm [IQR, 2.4-4.8] to 7.7 mm [IQR, 6.5-9.4]; P<0.05). Seven patients (18%) had procedural adverse events. Twenty-seven (69%) patients underwent elective reintervention at a median time of 49.3 (IQR, 26.5-63.2) months from SI, with 8 (21%) stents requiring repeat SI for stent fracture. Over a median follow-up of 67.2 (IQR, 33.8-116.1) months, 25 patients (69%) were without hypertension or blood pressure gradient. Three (11%) patients developed femoral arterial occlusion. CONCLUSIONS: Adult sized SI is an alternative to surgical intervention for small patients with CoA. SI carries a risk of access-related complications, which may improve with the development of lower profile stents with adult sized maximum diameters.


Asunto(s)
Coartación Aórtica , Adulto , Angioplastia de Balón/efectos adversos , Coartación Aórtica/diagnóstico por imagen , Coartación Aórtica/cirugía , Niño , Estudios de Seguimiento , Humanos , Estudios Retrospectivos , Stents , Resultado del Tratamiento
10.
Cardiol Young ; 31(9): 1407-1411, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33597057

RESUMEN

BACKGROUND: Three-dimensional printing is increasingly utilised for congenital heart defect procedural planning. CT or MR datasets are typically used for printing, but similar datasets can be obtained from three-dimensional rotational angiography. We sought to assess the feasibility and accuracy of printing three-dimensional models of CHD from rotational angiography datasets. METHODS: Retrospective review of CHD catheterisations using rotational angiography was performed, and patient and procedural details were collected. Imaging data from rotational angiography were segmented, cleaned, and printed with polylactic acid on a Dremel® 3D Idea Builder (Dremel, Mount Prospect, IL, USA). Printing time and materials' costs were captured. CT scans of printed models were compared objectively to the original virtual models. Two independent, non-interventional paediatric cardiologists provided subjective ratings of the quality and accuracy of the printed models. RESULTS: Rotational angiography data from 15 catheterisations on vascular structures were printed. Median print time was 3.83 hours, and material costs were $2.84. The CT scans of the printed models highly matched with the original digital models (root mean square for Hausdorff distance 0.013 ± 0.003 mesh units). Independent reviewers correctly described 80 and 87% of the models (p = 0.334) and reported high quality and accuracy (5 versus 5, p = NS; κ = 0.615). CONCLUSION: Imaging data from rotational angiography can be converted into accurate three-dimensional-printed models of CHD. The cost of printing the models was negligible, but the print time was prohibitive for real-time use. As the speed of three-dimensional printing technology increases, novel future applications may allow for printing patient-specific devices based on rotational angiography datasets.


Asunto(s)
Cardiopatías Congénitas , Impresión Tridimensional , Angiografía , Cateterismo Cardíaco , Niño , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Modelos Anatómicos , Estudios Retrospectivos
11.
J Am Coll Cardiol ; 76(24): 2847-2858, 2020 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-33303074

RESUMEN

BACKGROUND: There are limited published data focused on outcomes of transcatheter pulmonary valve replacement (TPVR) with either a Sapien XT or Sapien 3 (S3) valve. OBJECTIVES: This study sought to report short-term outcomes in a large cohort of patients who underwent TPVR with either a Sapien XT or S3 valve. METHODS: Data were entered retrospectively into a multicenter registry for patients who underwent attempted TPVR with a Sapien XT or S3 valve. Patient-related, procedural, and short-term outcomes data were characterized overall and according to type of right ventricular outflow tract (RVOT) anatomy. RESULTS: Twenty-three centers enrolled a total of 774 patients: 397 (51%) with a native/patched RVOT; 183 (24%) with a conduit; and 194 (25%) with a bioprosthetic valve. The S3 was used in 78% of patients, and the XT was used in 22%, with most patients receiving a 29-mm (39%) or 26-mm (34%) valve. The implant was technically successful in 754 (97.4%) patients. Serious adverse events were reported in 67 patients (10%), with no difference between RVOT anatomy groups. Fourteen patients underwent urgent surgery. Nine patients had a second valve implanted. Among patients with available data, tricuspid valve injury was documented in 11 (1.7%), and 9 others (1.3%) had new moderate or severe regurgitation 2 grades higher than pre-implantation, for 20 (3.0%) total patients with tricuspid valve complications. Valve function at discharge was excellent in most patients, but 58 (8.5%) had moderate or greater pulmonary regurgitation or maximum Doppler gradients >40 mm Hg. During limited follow-up (n = 349; median: 12 months), 9 patients were diagnosed with endocarditis, and 17 additional patients underwent surgical valve replacement or valve-in-valve TPVR. CONCLUSIONS: Acute outcomes after TPVR with balloon-expandable valves were generally excellent in all types of RVOT. Additional data and longer follow-up will be necessary to gain insight into these issues.


Asunto(s)
Procedimientos Endovasculares/estadística & datos numéricos , Implantación de Prótesis de Válvulas Cardíacas/estadística & datos numéricos , Prótesis Valvulares Cardíacas , Válvula Pulmonar , Sistema de Registros , Adolescente , Adulto , Bioprótesis , Niño , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/métodos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
12.
Neoreviews ; 21(7): e469-e478, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32611564

RESUMEN

In view of the known complications of drug therapy and open surgical ligation, and the potential for prolonged patent ductus arteriosus (PDA) exposure to be harmful, health care practitioners have sought new approaches to achieve definitive ductal closure. Interest in percutaneous (catheter-based) PDA closure has emerged within the neonatal community as a viable treatment option, because it has been fueled by recent procedural and device modifications, as well as mounting feasibility and safety data. Herein, we provide a contemporary review of percutaneous PDA closure among infants at the crux of the medical debate-very-low-weight infants (≤1,500 g), including: 1) characterization of traditional PDA treatments (drug therapy, open surgical ligation) and conservative (nonintervention) management options; 2) a general overview of the major procedural steps of percutaneous ductal closure, including efforts to reduce thrombotic complications and the emergence of a novel US Food and Drug Administration-approved device; 3) a systematic review and meta-analysis to better understand risk profiles of percutaneous PDA closure in this population; and 4) discussion of current gaps in our understanding of optimal PDA care, including the critical need for well-designed, randomized, controlled clinical trials.


Asunto(s)
Cateterismo Cardíaco , Conducto Arterioso Permeable/terapia , Recién Nacido de muy Bajo Peso , Cateterismo Cardíaco/métodos , Conducto Arterioso Permeable/tratamiento farmacológico , Conducto Arterioso Permeable/cirugía , Humanos , Recién Nacido
13.
Catheter Cardiovasc Interv ; 96(6): 1266-1276, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32433821

RESUMEN

OBJECTIVES: Characterize the safety and effectiveness of the Amplatzer Piccolo Occluder for patent ductus arteriosus (PDA) closure. BACKGROUND: The presence of a hemodynamically significant PDA has been associated with an increased risk of morbidity and mortality in children born premature. METHODS: This was a single arm, prospective, multicenter, non-randomized study to evaluate the Amplatzer Piccolo Occluder to treat PDA in patients ≥700 g. From June 2017 to February 2019, 200 patients were enrolled at nine centers, with 100 patients weighing ≤2 kg. Primary effectiveness endpoint was the rate of PDA closure at 6-month follow-up. Primary safety endpoint was the rate of major complications through 6 months. Secondary endpoint was rate of significant pulmonary or aortic obstruction through 6 months' follow-up. RESULTS: The implant success rate was 95.5% (191/200) overall and 99% in patients ≤2 kg (99/100). The primary effectiveness endpoint was achieved in 99.4% of implanted patients. Four patients experienced a primary safety endpoint event (2 transfusions, 1 hemolysis, and 1 aortic obstruction). There were no branch pulmonary artery obstructions. Five patients, all ≤2 kg, were noted to have worsening of tricuspid regurgitation (TR) after the procedure. None of the TR incidences manifested clinically. The Amplatzer Piccolo Occluder received FDA approval in January 2019 and became the first device approved for PDA closure in patients ≥700 g. CONCLUSIONS: This study supports the safety and effectiveness of the Amplatzer Piccolo Occluder, particularly in patients between 700 g and 2 kg where there is currently a significant unmet need in the United States. ClinicalTrials.gov identifier: NCT03055858.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Conducto Arterioso Permeable/terapia , Recien Nacido Extremadamente Prematuro , Recién Nacido de muy Bajo Peso , Dispositivo Oclusor Septal , Peso al Nacer , Cateterismo Cardíaco/efectos adversos , Circulación Coronaria , Conducto Arterioso Permeable/diagnóstico por imagen , Conducto Arterioso Permeable/fisiopatología , Femenino , Edad Gestacional , Hemodinámica , Humanos , Recién Nacido , Masculino , Estudios Prospectivos , Diseño de Prótesis , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
14.
Catheter Cardiovasc Interv ; 95(2): 270-279, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31609082

RESUMEN

OBJECTIVE: We describe the technical considerations of transcatheter implantation of the CardioMEMS™ HF System (Abbott, Abbott Park, IL) in adult patients with complex palliated congenital heart disease (CHD) and advanced heart failure (HF). BACKGROUND: Ambulatory pulmonary artery (PA) pressure monitoring with implantable hemodynamic monitors (IHMs) has been shown to reduce HF-related hospital admissions in non-CHD populations. HF is a common late cardiovascular complication in adult CHD necessitating better understanding of IHM application in this population. METHODS: We analyzed adults with complex CHD and advanced HF who were referred for CardioMEMS™ device implantation (2015-2018). Feasibility of device implantation, defined by successful device implantation and calibration, and procedural outcomes were evaluated. RESULTS: CardioMEMS™ was successfully implanted in all 14 adults (35.5 ± 9.2 years old, 72 ± 12 kg) with complex CHD (single ventricle/Fontan, n = 8 [57%]; d-transposition of the great arteries/atrial switch, n = 6 [43%]). The device was delivered via femoral venous access in 13 (93%) patients and implanted in the left PA in 12 (86%). A long sheath was used in 8 (57%) patients, including 5/6 with an atrial switch operation. There was one device migration that did not require retrieval. CONCLUSIONS: Transcatheter implantation of an IHM is feasible in select complex adult CHD patients with advanced HF. Further studies evaluating integration of ambulatory hemodynamics and the impact on clinical care are needed. This technology has the potential to improve medical management of advanced HF in patients with Fontan and atrial switch physiologies and provide new insights into their ambulatory hemodynamics.


Asunto(s)
Presión Arterial , Monitoreo Ambulatorio de la Presión Arterial/instrumentación , Monitores de Presión Sanguínea , Cardiopatías Congénitas/terapia , Insuficiencia Cardíaca/diagnóstico , Cuidados Paliativos , Arteria Pulmonar/fisiopatología , Tecnología de Sensores Remotos/instrumentación , Adulto , Femenino , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/fisiopatología , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
15.
J Pediatr ; 212: 144-150.e3, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31262530

RESUMEN

OBJECTIVES: To describe longer term outcomes for infants <6 kg undergoing percutaneous occlusion of the patent ductus arteriosus (PDA). STUDY DESIGN: This was a retrospective cohort study of infants <6 kg who underwent isolated percutaneous closure of the PDA at a single, tertiary center (2003-2017). Cardiopulmonary outcomes and device-related complications (eg, left pulmonary artery obstruction) were examined for differences across weight thresholds (very low weight, <3 kg; low weight, 3-<6 kg). We assessed composite measures of respiratory status during and beyond the initial hospitalization using linear mixed effects models. RESULTS: In this cohort of lower weight infants, 92 of 106 percutaneous occlusion procedures were successful. Median age and weight at procedure were 3.0 months (range, 0.5-11.1 months) and 3.7 kg (range, 1.4-5.9 kg), respectively. Among infants with pulmonary artery obstruction on initial postprocedural echocardiograms (n = 20 [22%]), obstruction persisted through hospital discharge in 3 infants. No measured variables were associated with device-related complications. Rates of oxygenation failure (28% vs 8%; P < .01) and decreased left ventricular systolic function (29% vs 5%; P < .01) were higher among very low weight than low weight infants. Pulmonary scores decreased (indicating improved respiratory status) following percutaneous PDA closure. CONCLUSIONS: Percutaneous PDA occlusion among lower weight infants is associated with potential longer term improvements in respiratory health. Risks of device-related complications and adverse cardiopulmonary outcomes, particularly among very low weight infants, underscore the need for continued device modification. Before widespread use, clinical trials comparing percutaneous occlusion vs alternative treatments are needed.


Asunto(s)
Conducto Arterioso Permeable/terapia , Oclusión Terapéutica , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Lactante , Recién Nacido de Bajo Peso , Recién Nacido , Masculino , Estudios Retrospectivos , Oclusión Terapéutica/métodos , Factores de Tiempo , Resultado del Tratamiento
16.
Catheter Cardiovasc Interv ; 94(3): 416-421, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-31276274

RESUMEN

The Gore Viabahn VBX balloon-expandable endoprosthesis (W. L. Gore & Associates, Flagstaff, AZ) is a flexible covered stent that is FDA-approved for the treatment of iliac artery stenosis, including lesions at the aortic bifurcation. In this case series, we report the first use of the VBX covered stent in congenital heart disease, highlighting several of its unique advantages.


Asunto(s)
Angioplastia de Balón/instrumentación , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Cardiopatías Congénitas/cirugía , Cuidados Paliativos , Enfermedades Vasculares Periféricas/cirugía , Stents , Adulto , Femenino , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/fisiopatología , Humanos , Recién Nacido , Masculino , Enfermedades Vasculares Periféricas/diagnóstico por imagen , Enfermedades Vasculares Periféricas/fisiopatología , Diseño de Prótesis , Resultado del Tratamiento
18.
Echocardiography ; 36(7): 1434-1436, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31215683

RESUMEN

An 8-year-old boy with tetralogy of Fallot, pulmonary atresia, and major aortopulmonary collaterals status post complete repair including a fenestrated ventricular septal defect patch presented to the catheterization laboratory for fenestration closure. During the procedure, the catheterization wire was found to have an unusual intracardiac loop and was unable to be straightened within the heart. Three-dimensional transesophageal echocardiography revealed the wire was looped around a right ventricular papillary muscle. The wire was readjusted, and the fenestration was successfully closed. Three-dimensional imaging was essential in unambiguously defining the catheter course and assisting in fenestration closure.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/instrumentación , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Defectos del Tabique Interventricular/diagnóstico por imagen , Defectos del Tabique Interventricular/cirugía , Músculos Papilares/diagnóstico por imagen , Niño , Humanos , Masculino , Músculos Papilares/cirugía , Atresia Pulmonar/complicaciones , Tetralogía de Fallot/complicaciones
19.
Congenit Heart Dis ; 14(1): 95-99, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30811795

RESUMEN

The optimal treatment method for infants with a patent ductus arteriosus (PDA) necessitating closure remains a subject of controversy and debate. While the risks associated with surgical PDA ligation are well described, the available evidence base for alternative management strategies during infancy, including percutaneous closure or conservative (nonintervention) management, are not well explored. Among infants, the goals of this review are to: (a) use rigorous systematic review methodology to assess the quality and quantity of published reports on percutaneous closure vs surgical ligation; (b) compare outcomes of percutaneous closure vs conservative management; and (c) based on recommendations from the International PDA symposium, to elucidate needs and opportunities for future research and interdisciplinary collaboration. The available evidence base, as well as on broad consensus reached at the International PDA Symposium, suggests that a contemporary, pragmatic clinical trial comparing PDA treatment strategies is warranted. Additionally, quality assurance safeguards are necessary in the implementation of newer PDA closure devices. Finally, to determine best approaches to treatment for infants with PDA, tools for consistent data collection and reporting across centers and disciplines are needed to minimize heterogeneity and permit pooled analysis.


Asunto(s)
Cateterismo Cardíaco/tendencias , Procedimientos Quirúrgicos Cardíacos/tendencias , Conducto Arterioso Permeable/cirugía , Recién Nacido de Bajo Peso , Mejoramiento de la Calidad , Procedimientos Quirúrgicos Cardíacos/métodos , Humanos , Recién Nacido
20.
Catheter Cardiovasc Interv ; 93(3): 474-480, 2019 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-30419603

RESUMEN

OBJECTIVES: This study describes procedural and 1-year outcomes of the 16 mm Melody PB1016 valve in patients with dysfunctional RVOT conduits. BACKGROUND: The Melody PB1016 is a standard Melody valve produced from a 16 mm bovine jugular vein and is intended for deployment up to 20 mm. METHODS: This is a prospective, non-randomized, multicenter study of the procedural and short-term outcomes of Melody PB1016 TPV replacement within dysfunctional RVOT conduits. Data from eight centers were included in the analysis. RESULTS: During the study period, 39 patients underwent attempted Melody TPVR. Of the 39 patients, 30 underwent successful Melody TPVR. The majority of patients underwent placement of one or more stents prior to TPVR. There was a significant reduction in peak conduit pressure gradient following TPVR (38 mmHg vs. 11 mmHg, P < 0.001). There were three cases of confined conduit tears successfully treated with covered stents or the valve itself. Repeat catheterization was performed in one patient for early re-obstruction that was successfully treated with balloon valvuloplasty. At recent follow-up, there were no cases of more than mild valve regurgitation and the mean pulmonary valve gradient by echocardiogram remained reduced relative to pre-TPVR implant measurements (33.5 mmHg vs. 15.2 mmHg). There were no cases of valve stent fracture or endocarditis reported at the 1-year follow-up. CONCLUSIONS: Our analysis of TPVR with the PB1016 valve in RVOT conduits showed it to be safe and effective and can be performed in a wide range of conduit sizes with preserved valve function. ClinicalTrials.gov Identifier: NCT02347189.


Asunto(s)
Bioprótesis , Cateterismo Cardíaco/instrumentación , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Cardiopatías Congénitas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Venas Yugulares/trasplante , Insuficiencia de la Válvula Pulmonar/cirugía , Válvula Pulmonar/cirugía , Stents , Adolescente , Adulto , Animales , Canadá , Cateterismo Cardíaco/efectos adversos , Bovinos , Niño , Europa (Continente) , Femenino , Cardiopatías Congénitas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Xenoinjertos , Humanos , Masculino , Estudios Prospectivos , Diseño de Prótesis , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/fisiopatología , Recuperación de la Función , Resultado del Tratamiento , Estados Unidos , Adulto Joven