Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Radiother Oncol ; 195: 110237, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38513960

RESUMEN

We compared dynamic trajectory radiotherapy (DTRT) to state-of-the-art volumetric modulated arc therapy (VMAT) for 46 head and neck cancer cases. DTRT had lower dose to salivary glands and swallowing structure, resulting in lower predicted xerostomia and dysphagia compared to VMAT. DTRT is deliverable on C-arm linacs with high dosimetric accuracy.

2.
Radiother Oncol ; 195: 110226, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38492670

RESUMEN

The European SocieTy for Radiotherapy and Oncology (ESTRO) organized a one-year pilot mentoring programme. At evaluation after one year, both mentors and mentees scored the programme with a median score of 9 on a scale of 10. All of the mentors indicated that they wanted to participate again as mentors.

3.
Phys Imaging Radiat Oncol ; 29: 100535, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38298885

RESUMEN

Background and purpose: Many 4D particle therapy research concepts have been recently translated into clinics, however, remaining substantial differences depend on the indication and institute-related aspects. This work aims to summarise current state-of-the-art 4D particle therapy technology and outline a roadmap for future research and developments. Material and methods: This review focused on the clinical implementation of 4D approaches for imaging, treatment planning, delivery and evaluation based on the 2021 and 2022 4D Treatment Workshops for Particle Therapy as well as a review of the most recent surveys, guidelines and scientific papers dedicated to this topic. Results: Available technological capabilities for motion surveillance and compensation determined the course of each 4D particle treatment. 4D motion management, delivery techniques and strategies including imaging were diverse and depended on many factors. These included aspects of motion amplitude, tumour location, as well as accelerator technology driving the necessity of centre-specific dosimetric validation. Novel methodologies for X-ray based image processing and MRI for real-time tumour tracking and motion management were shown to have a large potential for online and offline adaptation schemes compensating for potential anatomical changes over the treatment course. The latest research developments were dominated by particle imaging, artificial intelligence methods and FLASH adding another level of complexity but also opportunities in the context of 4D treatments. Conclusion: This review showed that the rapid technological advances in radiation oncology together with the available intrafractional motion management and adaptive strategies paved the way towards clinical implementation.

4.
Phys Med Biol ; 69(5)2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38266298

RESUMEN

Objective.Respiratory motion of lung tumours and adjacent structures is challenging for radiotherapy. Online MR-imaging cannot currently provide real-time volumetric information of the moving patient anatomy, therefore limiting precise dose delivery, delivered dose reconstruction, and downstream adaptation methods.Approach.We tailor a respiratory motion modelling framework towards an MR-Linac workflow to estimate the time-resolved 4D motion from real-time data. We develop a multi-slice acquisition scheme which acquires thick, overlapping 2D motion-slices in different locations and orientations, interleaved with 2D surrogate-slices from a fixed location. The framework fits a motion model directly to the input data without the need for sorting or binning to account for inter- and intra-cycle variation of the breathing motion. The framework alternates between model fitting and motion-compensated super-resolution image reconstruction to recover a high-quality motion-free image and a motion model. The fitted model can then estimate the 4D motion from 2D surrogate-slices. The framework is applied to four simulated anthropomorphic datasets and evaluated against known ground truth anatomy and motion. Clinical applicability is demonstrated by applying our framework to eight datasets acquired on an MR-Linac from four lung cancer patients.Main results.The framework accurately reconstructs high-quality motion-compensated 3D images with 2 mm3isotropic voxels. For the simulated case with the largest target motion, the motion model achieved a mean deformation field error of 1.13 mm. For the patient cases residual error registrations estimate the model error to be 1.07 mm (1.64 mm), 0.91 mm (1.32 mm), and 0.88 mm (1.33 mm) in superior-inferior, anterior-posterior, and left-right directions respectively for the building (application) data.Significance.The motion modelling framework estimates the patient motion with high accuracy and accurately reconstructs the anatomy. The image acquisition scheme can be flexibly integrated into an MR-Linac workflow whilst maintaining the capability of online motion-management strategies based on cine imaging such as target tracking and/or gating.


Asunto(s)
Neoplasias Pulmonares , Radioterapia Guiada por Imagen , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Imagen por Resonancia Magnética/métodos , Movimiento (Física) , Imagenología Tridimensional , Respiración , Radioterapia Guiada por Imagen/métodos
5.
Med Phys ; 51(2): 1326-1339, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38131614

RESUMEN

BACKGROUND: Non-coplanar techniques have shown to improve the achievable dose distribution compared to standard coplanar techniques for multiple treatment sites but finding optimal beam directions is challenging. Dynamic collimator trajectory radiotherapy (colli-DTRT) is a new intensity modulated radiotherapy technique that uses non-coplanar partial arcs and dynamic collimator rotation. PURPOSE: To solve the beam angle optimization (BAO) problem for colli-DTRT and non-coplanar VMAT (NC-VMAT) by determining the table-angle and the gantry-angle ranges of the partial arcs through iterative 4π fluence map optimization (FMO) and beam direction elimination. METHODS: BAO considers all available beam directions sampled on a gantry-table map with the collimator angle aligned to the superior-inferior axis (colli-DTRT) or static (NC-VMAT). First, FMO is performed, and beam directions are scored based on their contributions to the objective function. The map is thresholded to remove the least contributing beam directions, and arc candidates are formed by adjacent beam directions with the same table angle. Next, FMO and arc candidate trimming, based on objective function penalty score, is performed iteratively until a desired total gantry angle range is reached. Direct aperture optimization on the final set of colli-DTRT or NC-VMAT arcs generates deliverable plans. colli-DTRT and NC-VMAT plans were created for seven clinically-motivated cases with targets in the head and neck (two cases), brain, esophagus, lung, breast, and prostate. colli-DTRT and NC-VMAT were compared to coplanar VMAT plans as well as to class-solution non-coplanar VMAT plans for the brain and head and neck cases. Dosimetric validation was performed for one colli-DTRT (head and neck) and one NC-VMAT (breast) plan using film measurements. RESULTS: Target coverage and conformity was similar for all techniques. colli-DTRT and NC-VMAT plans had improved dosimetric performance compared to coplanar VMAT for all treatment sites except prostate where all techniques were equivalent. For the head and neck and brain cases, mean dose reduction-in percentage of the prescription dose-to parallel organs was on average 0.7% (colli-DTRT), 0.8% (NC-VMAT) and 0.4% (class-solution) compared to VMAT. The reduction in D2% for the serial organs was on average 1.7% (colli-DTRT), 2.0% (NC-VMAT) and 0.9% (class-solution). For the esophagus, lung, and breast cases, mean dose reduction to parallel organs was on average 0.2% (colli-DTRT) and 0.3% (NC-VMAT) compared to VMAT. The reduction in D2% for the serial organs was on average 1.3% (colli-DTRT) and 0.9% (NC-VMAT). Estimated delivery times for colli-DTRT and NC-VMAT were below 4 min for a full gantry angle range of 720°, including transitions between arcs, except for the brain case where multiple arcs covered the whole table angle range. These times are in the same order as the class-solution for the head and neck and brain cases. Total optimization times were 25%-107% longer for colli-DTRT, including BAO, compared to VMAT. CONCLUSIONS: We successfully developed dosimetrically motivated BAO for colli-DTRT and NC-VMAT treatment planning. colli-DTRT and NC-VMAT are applicable to multiple treatment sites, including body sites, with beneficial or equivalent dosimetric performances compared to coplanar VMAT and reasonable delivery times.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Masculino , Encéfalo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Rotación , Femenino
7.
J Appl Clin Med Phys ; 24(11): e14165, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37782250

RESUMEN

Non-coplanar radiotherapy treatment techniques on C-arm linear accelerators have the potential to reduce dose to organs-at-risk in comparison with coplanar treatment techniques. Accurately predicting possible collisions between gantry, table and patient during treatment planning is needed to ensure patient safety. We offer a freely available collision prediction tool using Blender, a free and open-source 3D computer graphics software toolset. A geometric model of a C-arm linear accelerator including a library of patient models is created inside Blender. Based on the model, collision predictions can be used both to calculate collision-free zones and to check treatment plans for collisions. The tool is validated for two setups, once with and once without a full body phantom with the same table position. For this, each gantry-table angle combination with a 2° resolution is manually checked for collision interlocks at a TrueBeam system and compared to simulated collision predictions. For the collision check of a treatment plan, the tool outputs the minimal distance between the gantry, table and patient model and a video of the movement of the gantry and table, which is demonstrated for one use case. A graphical user interface allows user-friendly input of the table and patient specification for the collision prediction tool. The validation resulted in a true positive rate of 100%, which is the rate between the number of correctly predicted collision gantry-table combinations and the number of all measured collision gantry-table combinations, and a true negative rate of 89%, which is the ratio between the number of correctly predicted collision-free combinations and the number of all measured collision-free combinations. A collision prediction tool is successfully created and able to produce maps of collision-free zones and to test treatment plans for collisions including visualisation of the gantry and table movement.


Asunto(s)
Comportamiento del Uso de la Herramienta , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Programas Informáticos , Aceleradores de Partículas , Fantasmas de Imagen , Dosificación Radioterapéutica
8.
Med Phys ; 50(10): 6535-6542, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37338935

RESUMEN

BACKGROUND: Dynamic trajectory radiotherapy (DTRT) extends state-of-the-art volumetric modulated arc therapy (VMAT) by dynamic table and collimator rotations during beam-on. The effects of intrafraction motion during DTRT delivery are unknown, especially regarding the possible interplay between patient and machine motion with additional dynamic axes. PURPOSE: To experimentally assess the technical feasibility and quantify the mechanical and dosimetric accuracy of respiratory gating during DTRT delivery. METHODS: A DTRT and VMAT plan are created for a clinically motivated lung cancer case and delivered to a dosimetric motion phantom (MP) placed on the table of a TrueBeam system using Developer Mode. The MP reproduces four different 3D motion traces. Gating is triggered using an external marker block, placed on the MP. Mechanical accuracy and delivery time of the VMAT and DTRT deliveries with and without gating are extracted from the logfiles. Dosimetric performance is assessed by means of gamma evaluation (3% global/2 mm, 10% threshold). RESULTS: The DTRT and VMAT plans are successfully delivered with and without gating for all motion traces. Mechanical accuracy is similar for all experiments with deviations <0.14° (gantry angle), <0.15° (table angle), <0.09° (collimator angle) and <0.08 mm (MLC leaf positions). For DTRT (VMAT), delivery times are 1.6-2.3 (1.6- 2.5) times longer with than without gating for all motion traces except one, where DTRT (VMAT) delivery is 5.0 (3.6) times longer due to a substantial uncorrected baseline drift affecting only DTRT delivery. Gamma passing rates with (without) gating for DTRT/VMAT were ≥96.7%/98.5% (≤88.3%/84.8%). For one VMAT arc without gating it was 99.6%. CONCLUSION: Gating is successfully applied during DTRT delivery on a TrueBeam system for the first time. Mechanical accuracy is similar for VMAT and DTRT deliveries with and without gating. Gating substantially improved dosimetric performance for DTRT and VMAT.


Asunto(s)
Neoplasias Pulmonares , Radioterapia de Intensidad Modulada , Humanos , Estudios de Factibilidad , Radiometría , Pulmón , Neoplasias Pulmonares/radioterapia , Planificación de la Radioterapia Asistida por Computador , Dosificación Radioterapéutica
9.
Phys Imaging Radiat Oncol ; 26: 100442, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37197154

RESUMEN

Background and purpose: Anatomical changes may compromise the planned target coverage and organs-at-risk dose in particle therapy. This study reports on the practice patterns for adaptive particle therapy (APT) to evaluate current clinical practice and wishes and barriers to further implementation. Materials and methods: An institutional questionnaire was distributed to PT centres worldwide (7/2020-6/2021) asking which type of APT was used, details of the workflow, and what the wishes and barriers to implementation were. Seventy centres from 17 countries participated. A three-round Delphi consensus analysis (10/2022) among the authors followed to define recommendations on required actions and future vision. Results: Out of the 68 clinically operational centres, 84% were users of APT for at least one treatment site with head and neck being most common. APT was mostly performed offline with only two online APT users (plan-library). No centre used online daily re-planning. Daily 3D imaging was used for APT by 19% of users. Sixty-eight percent of users had plans to increase their use or change their technique for APT. The main barrier was "lack of integrated and efficient workflows". Automation and speed, reliable dose deformation for dose accumulation and higher quality of in-room volumetric imaging were identified as the most urgent task for clinical implementation of online daily APT. Conclusion: Offline APT was implemented by the majority of PT centres. Joint efforts between industry research and clinics are needed to translate innovations into efficient and clinically feasible workflows for broad-scale implementation of online APT.

10.
Phys Imaging Radiat Oncol ; 26: 100439, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37124167

RESUMEN

Background and purpose: Organ motion compromises accurate particle therapy delivery. This study reports on the practice patterns for real-time intrafractional motion-management in particle therapy to evaluate current clinical practice and wishes and barriers to implementation. Materials and methods: An institutional questionnaire was distributed to particle therapy centres worldwide (7/2020-6/2021) asking which type(s) of real-time respiratory motion management (RRMM) methods were used, for which treatment sites, and what were the wishes and barriers to implementation. This was followed by a three-round DELPHI consensus analysis (10/2022) to define recommendations on required actions and future vision. With 70 responses from 17 countries, response rate was 100% for Europe (23/23 centres), 96% for Japan (22/23) and 53% for USA (20/38). Results: Of the 68 clinically operational centres, 85% used RRMM, with 41% using both rescanning and active methods. Sixty-four percent used active-RRMM for at least one treatment site, mostly with gating guided by an external marker. Forty-eight percent of active-RRMM users wished to expand or change their RRMM technique. The main barriers were technical limitations and limited resources. From the DELPHI analysis, optimisation of rescanning parameters, improvement of motion models, and pre-treatment 4D evaluation were unanimously considered clinically important future focus. 4D dose calculation was identified as the top requirement for future commercial treatment planning software. Conclusion:  A majority of particle therapy centres have implemented RRMM. Still, further development and clinical integration were desired by most centres. Joint industry, clinical and research efforts are needed to translate innovation into efficient workflows for broad-scale implementation.

11.
Front Oncol ; 13: 1112481, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36937392

RESUMEN

Background: Pencil beam scanning (PBS) proton therapy can provide highly conformal target dose distributions and healthy tissue sparing. However, proton therapy of hepatocellular carcinoma (HCC) is prone to dosimetrical uncertainties induced by respiratory motion. This study aims to develop intra-treatment tumor motion monitoring during respiratory gated proton therapy and combine it with motion-including dose reconstruction to estimate the delivered tumor doses for individual HCC treatment fractions. Methods: Three HCC-patients were planned to receive 58 GyRBE (n=2) or 67.5 GyRBE (n=1) of exhale respiratory gated PBS proton therapy in 15 fractions. The treatment planning was based on the exhale phase of a 4-dimensional CT scan. Daily setup was based on cone-beam CT (CBCT) imaging of three implanted fiducial markers. An external marker block (RPM) on the patient's abdomen was used for exhale gating in free breathing. This study was based on 5 fractions (patient 1), 1 fraction (patient 2) and 6 fractions (patient 3) where a post-treatment control CBCT was available. After treatment, segmented 2D marker positions in the post-treatment CBCT projections provided the estimated 3D motion trajectory during the CBCT by a probability-based method. An external-internal correlation model (ECM) that estimated the tumor motion from the RPM motion was built from the synchronized RPM signal and marker motion in the CBCT. The ECM was then used to estimate intra-treatment tumor motion. Finally, the motion-including CTV dose was estimated using a dose reconstruction method that emulates tumor motion in beam's eye view as lateral spot shifts and in-depth motion as changes in the proton beam energy. The CTV homogeneity index (HI) The CTV homogeneity index (HI) was calculated as D 2 %  -  D 98 % D 50 %   × 100 % . Results: The tumor position during spot delivery had a root-mean-square error of 1.3 mm in left-right, 2.8 mm in cranio-caudal and 1.7 mm in anterior-posterior directions compared to the planned position. On average, the CTV HI was larger than planned by 3.7%-points (range: 1.0-6.6%-points) for individual fractions and by 0.7%-points (range: 0.3-1.1%-points) for the average dose of 5 or 6 fractions. Conclusions: A method to estimate internal tumor motion and reconstruct the motion-including fraction dose for PBS proton therapy of HCC was developed and demonstrated successfully clinically.

12.
Int J Radiat Oncol Biol Phys ; 116(2): 246-256, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-36792016

RESUMEN

PURPOSE: Organizational culture plays a major role in prioritizing diversity, equity, and inclusion (DEI) objectives by aligning individual values of employees with organizational values. However, effective strategies to create an inclusive organizational culture, in which these values are aligned, remain unclear. The European Society for Radiotherapy and Oncology (ESTRO) launched a qualitative study, as a follow-up of the previous project on DEI that highlighted low levels of inclusion and work engagement among radiation oncology (RO) professionals in Europe. The aim of the present study was to gain an understanding of how DEI could be improved within RO departments by creating a more inclusive organizational culture. METHODS AND MATERIALS: A qualitative research study was conducted by enrolling RO professionals from 4 selected European countries through an open call on the ESTRO platform. Respondents who completed an online survey and met the inclusion criteria, such as experiencing low DEI levels at work, were invited for an online semistructured interview. Interview transcripts were analyzed thematically with an abductive approach via concepts in relation to "DEI," "work engagement," "organizational culture," and "professional values." RESULTS: Twenty-six eligible respondents from Great Britain, Italy, Poland, and Switzerland were interviewed. The thematic analysis identified cases in which limited engagement at work emerged when the personal values of RO professionals conflicted with dominant organizational values, hampering DEI. Three conflicts were found between the following personal versus organizational values: (1) self-development versus efficiency, (2) togetherness versus competition, and (3) people-oriented versus task-oriented cultures. CONCLUSIONS: Awareness of how organizational values can conflict with professionals' values should be raised to improve inclusion and engagement in the workplace. Additionally, efforts should be focused on tackling existing power imbalances that hamper effective deliberation on organizational- versus personal-value conflicts.


Asunto(s)
Oncología por Radiación , Humanos , Diversidad, Equidad e Inclusión , Lugar de Trabajo , Europa (Continente) , Investigación Cualitativa
13.
Phys Imaging Radiat Oncol ; 24: 129-135, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36439328

RESUMEN

Background and purpose: Twitter presence in academia has been linked to greater research impact which influences career progression. The purpose of this study was to analyse Twitter activity of the radiotherapy community around ESTRO congresses with a focus on gender-related and geographic trends. Materials and methods: Tweets, re-tweets and replies, here designated as interactions, around the ESTRO congresses held in 2012-2021 were collected. Twitter activity was analysed temporally and, for the period 2016-2021, the geographical span of the ESTRO Twitter network was studied. Tweets and Twitter users collated during the 10 years analysed were ranked based on number of 'likes', 're-tweets' and followers, considered as indicators of leadership/influence. Gender representation was assessed for the top-end percentiles. Results: Twitter activity around ESTRO congresses was multiplied by 60 in 6 years growing from 150 interactions in 2012 to a peak of 9097 in 2018. In 2020, during the SARS-CoV-2 pandemic, activity dropped by 60 % to reach 2945 interactions and recovered to half the pre-pandemic level in 2021. Europe, North America and Oceania were strongly connected and remained the main contributors. While overall, 58 % of accounts were owned by men, this proportion increased towards top liked/re-tweeted tweets and most-followed profiles to reach up to 84 % in the top-percentiles. Conclusion: During the SARS-CoV-2 pandemic, Twitter activity around ESTRO congresses substantially decreased. Men were over-represented on the platform and in most popular tweets and influential accounts. Given the increasing importance of social media presence in academia the gender-based biases observed may help in understanding the gender gap in career progression.

14.
Clin Transl Radiat Oncol ; 37: 101-108, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36186923

RESUMEN

Purpose: The COVID-19 pandemic had a substantial effect on mental health and work productivity of early-career researchers working in Radiation Oncology (RO). However, the underlying mechanisms of these effects are unclear. The aim of the current qualitative study was therefore to achieve a better understanding of how these effects arose and could be managed in the future. Methods: This study was conducted jointly by RO and qualitative health researchers. Data was collected in four online Focus Groups with 6-11 RO researchers (total N = 31) working in Europe. The transcripts were analysed through a qualitative cross-impact analysis. Results: Causal relations were identified between seventeen variables that depict the impact of disrupted working conditions. Mental health and work productivity were indeed the most important affected variables, but relations between variables towards these impacts were complex. Relations could either be positive or negative and direct or indirect, leading to a cascade of interrelated events which are highly personal and could change over time. We developed the model 'impact of disrupted working conditions' depicting the identified variables and their relations, to allow more individual assessment and personalised solutions. Conclusion: The impacts of disrupted working conditions on RO researchers varied due to the complexity of interrelated variables. Consequently, collective actions are not sufficient, and a more personal approach is needed. Our impact model is recommended to help guide conversations and reflections with the aim of improving work/life balance. The participants showed high levels of personal responsibility towards their own mental health and work productivity. Although being an individual issue, a collective responsibility in developing such approaches is key due to the dependency on organizational variables.

15.
Radiat Oncol ; 17(1): 122, 2022 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-35841098

RESUMEN

BACKGROUND: Dynamic trajectory radiotherapy (DTRT) extends volumetric modulated arc therapy (VMAT) with dynamic table and collimator rotation during beam-on. The aim of the study is to establish DTRT path-finding strategies, demonstrate deliverability and dosimetric accuracy and compare DTRT to state-of-the-art VMAT for common head and neck (HN) cancer cases. METHODS: A publicly available library of seven HN cases was created on an anthropomorphic phantom with all relevant organs-at-risk (OARs) delineated. DTRT plans were generated with beam incidences minimizing fractional target/OAR volume overlap and compared to VMAT. Deliverability and dosimetric validation was carried out on the phantom. RESULTS: DTRT and VMAT had similar target coverage. For three locoregionally advanced oropharyngeal carcinomas and one adenoid cystic carcinoma, mean dose to the contralateral salivary glands, pharynx and oral cavity was reduced by 2.5, 1.7 and 3.1 Gy respectively on average with DTRT compared to VMAT. For a locally recurrent nasopharyngeal carcinoma, D0.03 cc to the ipsilateral optic nerve was above tolerance (54.0 Gy) for VMAT (54.8 Gy) but within tolerance for DTRT (53.3 Gy). For a laryngeal carcinoma, DTRT resulted in higher dose than VMAT to the pharynx and brachial plexus but lower dose to the upper oesophagus, thyroid gland and contralateral carotid artery. For a single vocal cord irradiation case, DTRT spared most OARs better than VMAT. All plans were delivered successfully on the phantom and dosimetric validation resulted in gamma passing rates of 93.9% and 95.8% (2%/2 mm criteria, 10% dose threshold). CONCLUSIONS: This study provides a proof of principle of DTRT for common HN cases with plans that were deliverable on a C-arm linac with high accuracy. The comparison with VMAT indicates substantial OAR sparing could be achieved.


Asunto(s)
Neoplasias de Cabeza y Cuello , Neoplasias Nasofaríngeas , Radioterapia de Intensidad Modulada , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Recurrencia Local de Neoplasia , Órganos en Riesgo/efectos de la radiación , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos
16.
Radiother Oncol ; 171: 198-204, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35461952

RESUMEN

BACKGROUND AND PURPOSE: Diversity, Equity and Inclusion (DEI) in the medical workforce is linked to improved patient care and innovation, as well as employee retention and engagement. The European Society for Radiotherapy and Oncology launched a survey to provide a benchmark of DEI and engagement among radiation oncology (RO) professionals in Europe. METHODS: An anonymous survey was disseminated among RO professionals in Europe. The survey collected demographics and professional information, and participants were asked if they felt they belonged to a minority group. A DEI and workforce engagement questionnaire by Person et al. evaluated 8 inclusion factors. A favourable score was calculated by adding the percentage of "strongly agreed" or "agreed" answers. RESULTS: A total of 812 complete responses were received from 35 European countries. 21% of respondents felt they belonged to a minority group, mostly based on race/ethnicity (5.9%), nationality (4.8%) and age (4.3%). Compared to benchmark data from the United States, scores were lower for most inclusion factors, and to a greater extent for minority groups. The overall favourable score was 58% for those belonging to a minority group, significantly lower than for other respondents (71%, p < 0.001). Those belonging to a minority group because of their gender or age had the lowest overall favourable score (47% and 51% respectively). CONCLUSIONS: Our work indicates that actions to improve DEI and workforce engagement among RO professionals in Europe are urgently needed, in particular among minority groups. This would potentially improve employee wellbeing and retention, promoting high quality care and innovation.


Asunto(s)
Oncología por Radiación , Benchmarking , Europa (Continente) , Humanos , Grupos Minoritarios , Estados Unidos , Recursos Humanos
17.
Med Phys ; 49(7): 4780-4793, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35451087

RESUMEN

BACKGROUND: Evaluating plan robustness is a key step in radiotherapy. PURPOSE: To develop a flexible Monte Carlo (MC)-based robustness calculation and evaluation tool to assess and quantify dosimetric robustness of intensity-modulated radiotherapy (IMRT) treatment plans by exploring the impact of systematic and random uncertainties resulting from patient setup, patient anatomy changes, and mechanical limitations of machine components. METHODS: The robustness tool consists of two parts: the first part includes automated MC dose calculation of multiple user-defined uncertainty scenarios to populate a robustness space. An uncertainty scenario is defined by a certain combination of uncertainties in patient setup, rigid intrafraction motion and in mechanical steering of the following machine components: angles of gantry, collimator, table-yaw, table-pitch, table-roll, translational positions of jaws, multileaf-collimator (MLC) banks, and single MLC leaves. The Swiss Monte Carlo Plan (SMCP) is integrated in this tool to serve as the backbone for the MC dose calculations incorporating the uncertainties. The calculated dose distributions serve as input for the second part of the tool, handling the quantitative evaluation of the dosimetric impact of the uncertainties. A graphical user interface (GUI) is developed to simultaneously evaluate the uncertainty scenarios according to user-specified conditions based on dose-volume histogram (DVH) parameters, fast and exact gamma analysis, and dose differences. Additionally, a robustness index (RI) is introduced with the aim to simultaneously evaluate and condense dosimetric robustness against multiple uncertainties into one number. The RI is defined as the ratio of scenarios passing the conditions on the dose distributions. Weighting of the scenarios in the robustness space is possible to consider their likelihood of occurrence. The robustness tool is applied on IMRT, a volumetric modulated arc therapy (VMAT), a dynamic trajectory radiotherapy (DTRT), and a dynamic mixed beam radiotherapy (DYMBER) plan for a brain case to evaluate the robustness to uncertainties of gantry-, table-, collimator angle, MLC, and intrafraction motion. Additionally, the robustness of the IMRT, VMAT, and DTRT plan against patient setup uncertainties are compared. The robustness tool is validated by Delta4 measurements for scenarios including all uncertainty types available. RESULTS: The robustness tool performs simultaneous calculation of uncertainty scenarios, and the GUI enables their fast evaluation. For all evaluated plans and uncertainties, the planning target volume (PTV) margin prevented major clinical target volume (CTV) coverage deterioration (maximum observed standard deviation of D 98 % CTV $D98{\% _{{\rm{CTV}}}}$ was 1.3 Gy). OARs close to the PTV experienced larger dosimetric deviations (maximum observed standard deviation of D 2 % chiasma $D2{\% _{{\rm{chiasma}}}}$ was 14.5 Gy). Robustness comparison by RI evaluation against patient setup uncertainties revealed better dosimetric robustness of the VMAT and DTRT plans as compared to the IMRT plan. Delta4 validation measurements agreed with calculations by >96% gamma-passing rate (3% global/2 mm). CONCLUSIONS: The robustness tool was successfully implemented. Calculation and evaluation of uncertainty scenarios with the robustness tool were demonstrated on a brain case. Effects of patient and machine-specific uncertainties and the combination thereof on the dose distribution are evaluated in a user-friendly GUI to quantitatively assess and compare treatment plans and their robustness.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Método de Montecarlo , Radiometría/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Incertidumbre
18.
Radiother Oncol ; 170: 89-94, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35189156

RESUMEN

PURPOSE: To update the 2011 ESTRO-EFOMP core curriculum (CC) for education and training of medical physics experts (MPE)s working in radiotherapy (RT), in line with recent EU guidelines, and to provide a framework for European countries to develop their own curriculum. MATERIAL AND METHODS: Since September 2019, 27 European MPEs representing ESTRO, EFOMP and National Societies, with expertise covering all subfields of RT physics, have revised the CC for recent advances in RT. The ESTRO and EFOMP Education Councils, all European National Societies and international stakeholders have been involved in the revision process. RESULTS: A 4-year training period has been proposed, with a total of 240 ECTS (European Credit Transfer and Accumulation System). Training entrance levels have been defined ensuring the necessary physics and mathematics background. The concept of competency-based education has been reinforced by introducing the CanMEDS role framework. The updated CC includes (ablative) stereotactic-, MR-guided- and adaptive RT, particle therapy, advanced automation, complex quantitative data analysis (big data/artificial intelligence), use of biological images, and personalized treatments. Due to the continuously increasing RT complexity, more emphasis has been given to quality management. Clear requirements for a research project ensure a proper preparation of MPE residents for their central role in science and innovation in RT. CONCLUSION: This updated, 3rd edition of the CC provides an MPE training framework for safe and effective practice of modern RT, while acknowledging the significant efforts needed in some countries to reach this level. The CC can contribute to further harmonization of MPE training in Europe.


Asunto(s)
Inteligencia Artificial , Oncología por Radiación , Curriculum , Europa (Continente) , Física Sanitaria/educación , Humanos , Oncología por Radiación/educación
19.
Phys Imaging Radiat Oncol ; 19: 25-32, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34179522

RESUMEN

BACKGROUND AND PURPOSE: The COVID-19 pandemic has imposed changes in radiotherapy (RT) departments worldwide. Medical physicists (MPs) are key healthcare professionals in maintaining safe and effective RT. This study reports on MPs experience during the first pandemic peak and explores the consequences on their work. METHODS: A 39-question survey on changes in departmental and clinical practice and on the impact for the future was sent to the global MP community. A total of 433 responses were analysed by professional role and by country clustered on the daily infection numbers. RESULTS: The impact of COVID-19 was bigger in countries with high daily infection rate. The majority of MPs worked in alternation at home/on-site. Among practice changes, implementation and/or increased use of hypofractionation was the most common (47% of the respondents). Sixteen percent of respondents modified patient-specific quality assurance (QA), 21% reduced machine QA, and 25% moved machine QA to weekends/evenings. The perception of trust in leadership and team unity was reversed between management MPs (towards increased trust and unity) and clinical MPs (towards a decrease). Changes such as home-working and increased use of hypofractionation were welcomed. However, some MPs were concerned about pressure to keep negative changes (e.g. weekend work). CONCLUSION: COVID-19 affected MPs through changes in practice and QA procedures but also in terms of trust in leadership and team unity. Some changes were welcomed but others caused worries for the future. This report forms the basis, from a medical physics perspective, to evaluate long-lasting changes within a multi-disciplinary setting.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...