Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Rev Lett ; 131(16): 161802, 2023 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-37925710

RESUMEN

We present a new measurement of the positive muon magnetic anomaly, a_{µ}≡(g_{µ}-2)/2, from the Fermilab Muon g-2 Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable beam, and improved knowledge of the magnetic field weighted by the muon distribution, ω[over ˜]_{p}^{'}, and of the anomalous precession frequency corrected for beam dynamics effects, ω_{a}. From the ratio ω_{a}/ω[over ˜]_{p}^{'}, together with precisely determined external parameters, we determine a_{µ}=116 592 057(25)×10^{-11} (0.21 ppm). Combining this result with our previous result from the 2018 data, we obtain a_{µ}(FNAL)=116 592 055(24)×10^{-11} (0.20 ppm). The new experimental world average is a_{µ}(exp)=116 592 059(22)×10^{-11} (0.19 ppm), which represents a factor of 2 improvement in precision.

2.
Phys Rev Lett ; 126(14): 141801, 2021 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-33891447

RESUMEN

We present the first results of the Fermilab National Accelerator Laboratory (FNAL) Muon g-2 Experiment for the positive muon magnetic anomaly a_{µ}≡(g_{µ}-2)/2. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of high-energy positrons from muon decays directly encodes the difference frequency ω_{a} between the spin-precession and cyclotron frequencies for polarized muons in a magnetic storage ring. The storage ring magnetic field is measured using nuclear magnetic resonance probes calibrated in terms of the equivalent proton spin precession frequency ω[over ˜]_{p}^{'} in a spherical water sample at 34.7 °C. The ratio ω_{a}/ω[over ˜]_{p}^{'}, together with known fundamental constants, determines a_{µ}(FNAL)=116 592 040(54)×10^{-11} (0.46 ppm). The result is 3.3 standard deviations greater than the standard model prediction and is in excellent agreement with the previous Brookhaven National Laboratory (BNL) E821 measurement. After combination with previous measurements of both µ^{+} and µ^{-}, the new experimental average of a_{µ}(Exp)=116 592 061(41)×10^{-11} (0.35 ppm) increases the tension between experiment and theory to 4.2 standard deviations.

3.
Struct Dyn ; 4(4): 044035, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28868325

RESUMEN

A frontier challenge in implementing femtosecond electron microscopy is to gain precise optical control of intense beams to mitigate collective space charge effects for significantly improving the throughput. Here, we explore the flexible uses of an RF cavity as a longitudinal lens in a high-intensity beam column for condensing the electron beams both temporally and spectrally, relevant to the design of ultrafast electron microscopy. Through the introduction of a novel atomic grating approach for characterization of electron bunch phase space and control optics, we elucidate the principles for predicting and controlling the phase space dynamics to reach optimal compressions at various electron densities and generating conditions. We provide strategies to identify high-brightness modes, achieving ∼100 fs and ∼1 eV resolutions with 106 electrons per bunch, and establish the scaling of performance for different bunch charges. These results benchmark the sensitivity and resolution from the fundamental beam brightness perspective and also validate the adaptive optics concept to enable delicate control of the density-dependent phase space structures to optimize the performance, including delivering ultrashort, monochromatic, high-dose, or coherent electron bunches.

4.
Phys Rev Lett ; 119(1): 014801, 2017 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-28731757

RESUMEN

This Letter reports the successful use of feedback from a spin polarization measurement to the revolution frequency of a 0.97 GeV/c bunched and polarized deuteron beam in the Cooler Synchrotron (COSY) storage ring in order to control both the precession rate (≈121 kHz) and the phase of the horizontal polarization component. Real time synchronization with a radio frequency (rf) solenoid made possible the rotation of the polarization out of the horizontal plane, yielding a demonstration of the feedback method to manipulate the polarization. In particular, the rotation rate shows a sinusoidal function of the horizontal polarization phase (relative to the rf solenoid), which was controlled to within a 1 standard deviation range of σ=0.21 rad. The minimum possible adjustment was 3.7 mHz out of a revolution frequency of 753 kHz, which changes the precession rate by 26 mrad/s. Such a capability meets a requirement for the use of storage rings to look for an intrinsic electric dipole moment of charged particles.

5.
Rev Sci Instrum ; 87(11): 115116, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910557

RESUMEN

A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of 10-29 e ⋅ cm by using polarized "magic" momentum 0.7 GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the standard model at the scale of 3000 TeV.

6.
Phys Rev Lett ; 117(5): 054801, 2016 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-27517774

RESUMEN

We observe a deuteron beam polarization lifetime near 1000 s in the horizontal plane of a magnetic storage ring (COSY). This long spin coherence time is maintained through a combination of beam bunching, electron cooling, sextupole field corrections, and the suppression of collective effects through beam current limits. This record lifetime is required for a storage ring search for an intrinsic electric dipole moment on the deuteron at a statistical sensitivity level approaching 10^{-29} e cm.

7.
Phys Rev Lett ; 115(9): 094801, 2015 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-26371657

RESUMEN

A new method to determine the spin tune is described and tested. In an ideal planar magnetic ring, the spin tune-defined as the number of spin precessions per turn-is given by ν(s)=γG (γ is the Lorentz factor, G the gyromagnetic anomaly). At 970 MeV/c, the deuteron spins coherently precess at a frequency of ≈120 kHz in the Cooler Synchrotron COSY. The spin tune is deduced from the up-down asymmetry of deuteron-carbon scattering. In a time interval of 2.6 s, the spin tune was determined with a precision of the order 10^{-8}, and to 1×10^{-10} for a continuous 100 s accelerator cycle. This renders the presented method a new precision tool for accelerator physics; controlling the spin motion of particles to high precision is mandatory, in particular, for the measurement of electric dipole moments of charged particles in a storage ring.

8.
Phys Rev Lett ; 87(11): 114302, 2001 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-11531528

RESUMEN

Long term simulations of Hamiltonian dynamical systems benefit from enforcing the symplectic symmetry. One of the several available methods to perform this symplectification is provided by the recently developed theory of extended generating functions. The theory offers an infinite supply of generator types that can be used for symplectification. Using Hofer's metric, a condition for optimal symplectification is given. In the weakly nonlinear case, the condition provides a generator type that, based on the limited information available on the system, in general gives optimal results.

10.
Artículo en Inglés | MEDLINE | ID: mdl-9965404
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...