Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
NPJ Breast Cancer ; 9(1): 12, 2023 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-36922547

RESUMEN

Although breast density decline with tamoxifen therapy is associated with greater therapeutic benefit, limited data suggest that endocrine symptoms may also be associated with improved breast cancer outcomes. However, it is unknown whether endocrine symptoms are associated with reductions in breast density after tamoxifen initiation. We evaluated treatment-associated endocrine symptoms and breast density change among 74 women prescribed tamoxifen in a 12-month longitudinal study. Treatment-associated endocrine symptoms and sound speed measures of breast density, assessed via novel whole breast ultrasound tomography (m/s), were ascertained before tamoxifen (T0) and at 1-3 (T1), 4-6 (T2), and 12 months (T3) after initiation. CYP2D6 status was genotyped, and tamoxifen metabolites were measured at T3. Using multivariable linear regression, we estimated mean change in breast density by treatment-associated endocrine symptoms adjusting for age, race, menopausal status, body mass index, and baseline density. Significant breast density declines were observed in women with treatment-associated endocrine symptoms (mean change (95% confidence interval) at T1:-0.26 m/s (-2.17,1.65); T2:-2.12 m/s (-4.02,-0.22); T3:-3.73 m/s (-5.82,-1.63); p-trend = 0.004), but not among women without symptoms (p-trend = 0.18) (p-interaction = 0.02). Similar declines were observed with increasing symptom frequency (p-trends for no symptoms = 0.91; low/moderate symptoms = 0.03; high symptoms = 0.004). Density declines remained among women with detectable tamoxifen metabolites or intermediate/efficient CYP2D6 metabolizer status. Emergent/worsening endocrine symptoms are associated with significant, early declines in breast density after tamoxifen initiation. Further studies are needed to assess whether these observations predict clinical outcomes. If confirmed, endocrine symptoms may be a proxy for tamoxifen response and useful for patients and providers to encourage adherence.

2.
J Clin Med ; 11(3)2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-35160244

RESUMEN

PURPOSE: Women whose mammographic breast density declines within 12-18 months of initiating tamoxifen for chemoprevention or adjuvant treatment show improved therapeutic responses compared with those whose density is unchanged. We tested whether measuring changes in sound speed (a surrogate of breast density) using ultrasound tomography (UST) could enable rapid identification of favorable responses to tamoxifen. METHODS: We evaluated serial density measures at baseline and at 1 to 3, 4 to 6, and 12+ months among 74 women (aged 30-70 years) following initiation of tamoxifen for clinical indications, including an elevated risk of breast cancer (20%) and diagnoses of in situ (39%) or invasive (40%) breast carcinoma, enrolled at Karmanos Cancer Institute and Henry Ford Health System (Detroit, MI, USA). For comparison, we evaluated an untreated group with screen negative mammography and frequency-matched on age, race, and menopausal status (n = 150), at baseline and 12 months. Paired t-tests were used to assess differences in UST sound speed over time and between tamoxifen-treated and untreated patients. RESULTS: Sound speed declined steadily over the 12 month period among patients receiving tamoxifen (mean (SD): -3.0 (8.2) m/s; p = 0.001), whereas density remained unchanged in the untreated group (mean (SD): 0.4 (7.1) m/s; p = 0.75 (relative change between groups: p = 0.0009)). In the tamoxifen group, we observed significant sound speed reductions as early as 4-6 months after tamoxifen initiation (mean (SD): -2.1 (6.8) m/s; p = 0.008). Sound speed reductions were greatest among premenopausal patients (P-interaction = 0.0002) and those in the middle and upper tertiles of baseline sound speed (P-interaction = 0.002). CONCLUSIONS: UST can image rapid declines in sound speed following initiation of tamoxifen. Given that sound speed and mammographic density are correlated, we propose that UST breast imaging may capture early responses to tamoxifen, which in turn may have utility in predicting therapeutic efficacy.

3.
J Breast Imaging ; 2(6): 569-576, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33385161

RESUMEN

OBJECTIVE: To evaluate the combination of tumor volume and sound speed as a potential imaging marker for assessing neoadjuvant chemotherapy (NAC) response. METHODS: This study was carried out under an IRB-approved protocol (written consent required). Fourteen patients undergoing NAC for invasive breast cancer were examined with ultrasound tomography (UST) throughout their treatment. The volume (V) and the volume-averaged sound speed (VASS) of the tumors and their changes were measured for each patient. Time-dependent response curves of V and VASS were constructed individually for each patient and then as averages for the complete versus partial response groups in order to characterize differences between the two groups. Differences in group means were assessed for statistical significance using t-tests. Differences in shapes of group curves were evaluated with Kolmogorov-Smirnoff tests. RESULTS: On average, tumor volume and sound speed in the partial response group showed a gradual decline in the first 60 days of treatment, while the complete response group showed a much steeper decline (P < 0.05). The shapes of the response curves of the two groups, corresponding to the entire treatment period, were also found to be significantly different (P < 0.05). Furthermore, large simultaneous drops in volume and sound speed in the first 3 weeks of treatment were characteristic only of the complete responders (P < 0.05). CONCLUSION: This study demonstrates the feasibility of using UST to monitor NAC response, warranting future studies to better define the potential of UST for noninvasive, rapid identification of partial versus complete responders in women undergoing NAC.

4.
Ultrasound Med Biol ; 43(1): 91-103, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27692872

RESUMEN

A population of 165 women with negative mammographic screens also received an ultrasound tomography (UST) examination at the Karmanos Cancer Institute in Detroit, MI. Standard statistical techniques were employed to measure the associations between the various mammographic- and UST-related density measures and various participant characteristics such as age, weight and height. The mammographic percent density (MPD) was found to have similar strength associations with UST mean sound speed (Spearman coefficient, rs = 0.722, p < 0.001) and UST median sound speed (rs = 0.737, p < 0.001). Both were stronger than the associations between MPD with two separate measures of UST percent density, a k-means (rs = 0.568, p < 0.001) or a threshold (rs = 0.715, p < 0.001) measure. Segmentation of the UST sound speed images into dense and non-dense volumes showed weak to moderate associations with the mammographically equivalent measures. Relationships were found to be inversely and weakly associated between age and the UST mean sound speed (rs = -0.239, p = 0.002), UST median sound speed (rs = -0.226, p = 0.004) and MPD (rs = -0.204, p = 0.008). Relationships were found to be inversely and moderately associated between body mass index (BMI) and the UST mean sound speed (rs = -0.429, p < 0.001), UST median sound speed (rs = -0.447, p < 0.001) and MPD (rs = -0.489, p < 0.001). The results confirm and strengthen findings presented in previous work indicating that UST sound speed imaging yields viable markers of breast density in a manner consistent with mammography, the current clinical standard. These results lay the groundwork for further studies to assess the role of sound speed imaging in risk prediction.


Asunto(s)
Densidad de la Mama , Mama/diagnóstico por imagen , Imagenología Tridimensional/métodos , Ultrasonografía Mamaria/métodos , Adulto , Anciano , Femenino , Humanos , Persona de Mediana Edad
5.
Med Phys ; 42(10): 5671-8, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26429241

RESUMEN

PURPOSE: High breast density, as measured by mammography, is associated with increased breast cancer risk, but standard methods of assessment have limitations including 2D representation of breast tissue, distortion due to breast compression, and use of ionizing radiation. Ultrasound tomography (UST) is a novel imaging method that averts these limitations and uses sound speed measures rather than x-ray imaging to estimate breast density. The authors evaluated the reproducibility of measures of speed of sound and changes in this parameter using UST. METHODS: One experienced and five newly trained raters measured sound speed in serial UST scans for 22 women (two scans per person) to assess inter-rater reliability. Intrarater reliability was assessed for four raters. A random effects model was used to calculate the percent variation in sound speed and change in sound speed attributable to subject, scan, rater, and repeat reads. The authors estimated the intraclass correlation coefficients (ICCs) for these measures based on data from the authors' experienced rater. RESULTS: Median (range) time between baseline and follow-up UST scans was five (1-13) months. Contributions of factors to sound speed variance were differences between subjects (86.0%), baseline versus follow-up scans (7.5%), inter-rater evaluations (1.1%), and intrarater reproducibility (∼0%). When evaluating change in sound speed between scans, 2.7% and ∼0% of variation were attributed to inter- and intrarater variation, respectively. For the experienced rater's repeat reads, agreement for sound speed was excellent (ICC = 93.4%) and for change in sound speed substantial (ICC = 70.4%), indicating very good reproducibility of these measures. CONCLUSIONS: UST provided highly reproducible sound speed measurements, which reflect breast density, suggesting that UST has utility in sensitively assessing change in density.


Asunto(s)
Mama/citología , Tomografía/métodos , Ondas Ultrasónicas , Adulto , Anciano , Femenino , Humanos , Persona de Mediana Edad , Reproducibilidad de los Resultados
6.
Proc SPIE Int Soc Opt Eng ; 9040: 90400S, 2014 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-25309102

RESUMEN

Ultrasound tomography (UST) employs sound waves to produce three-dimensional images of breast tissue and precisely measures the sound speed of breast tissue composition. High breast density is a strong breast cancer risk factor and sound speed is directly proportional to breast density. UST provides a quantitative measure of breast density based on three-dimensional imaging without compression, thereby overcoming the shortcomings of many other imaging modalities. The quantitative nature of the UST breast density measures are tied to an external standard, so sound speed measurement in breast tissue should be independent of specific hardware. The work presented here compares breast sound speed measurement obtained with two different UST devices. The Computerized Ultrasound Risk Evaluation (CURE) system located at the Karmanos Cancer Institute in Detroit, Michigan was recently replaced with the SoftVue ultrasound tomographic device. Ongoing clinical trials have used images generated from both sets of hardware, so maintaining consistency in sound speed measurements is important. During an overlap period when both systems were in the same exam room, a total of 12 patients had one or both of their breasts imaged on both systems on the same day. There were 22 sound speed scans analyzed from each system and the average breast sound speeds were compared. Images were either reconstructed using saved raw data (for both CURE and SoftVue) or were created during the image acquisition (saved in DICOM format for SoftVue scans only). The sound speed measurements from each system were strongly and positively correlated with each other. The average difference in sound speed between the two sets of data was on the order of 1-2 m/s and this result was not statistically significant. The only sets of images that showed a statistical difference were the DICOM images created during the SoftVue scan compared to the SoftVue images reconstructed from the raw data. However, the discrepancy between the sound speed values could be easily handled by uniformly increasing the DICOM sound speed by approximately 0.5 m/s. These results suggest that there is no fundamental difference in sound speed measurement for the two systems and support combining data generated with these instruments in future studies.

7.
J Cancer Educ ; 28(2): 270-4, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23467999

RESUMEN

Little is known about women's knowledge of breast density or between-race differences in this knowledge. In the current study, we examined knowledge of breast density and awareness of its role as a breast cancer risk factor among women who had previously taken part in a breast imaging study. Seventy-seven women (54.5 % Black) returned a survey assessing perceptions and accuracy of breast density knowledge, knowledge of one's own breast density, and breast cancer risk awareness. White women had greater perceived knowledge of breast density compared to Black women; however, differences in the accuracy of definitions of breast density were due to education. Black women were less likely to know how dense their own breasts were. Black and White women both lacked awareness that having dense breast increased breast cancer risk. The results highlight the need to disseminate information regarding breast density to women, while ensuring that the information is equally accessible to both Black and White women.


Asunto(s)
Concienciación , Negro o Afroamericano/psicología , Mama/patología , Conocimientos, Actitudes y Práctica en Salud/etnología , Neoplasias/diagnóstico por imagen , Neoplasias/etnología , Ultrasonografía Mamaria , Población Blanca/psicología , Adulto , Negro o Afroamericano/educación , Anciano , Femenino , Educación en Salud , Humanos , Persona de Mediana Edad , Factores de Riesgo , Gravedad Específica , Estados Unidos , Población Blanca/educación
8.
Artículo en Inglés | MEDLINE | ID: mdl-37033290

RESUMEN

For women with dense breast tissue, who are at much higher risk for developing breast cancer, the performance of mammography is at its worst. Consequently, many early cancers go undetected when they are the most treatable. Improved cancer detection for women with dense breasts would decrease the proportion of breast cancers diagnosed at later stages, which would significantly lower the mortality rate. The emergence of whole breast ultrasound provides good performance for women with dense breast tissue, and may eliminate the current trade-off between the cost effectiveness of mammography and the imaging performance of more expensive systems such as magnetic resonance imaging. We report on the performance of SoftVue, a whole breast ultrasound imaging system, based on the principles of ultrasound tomography. SoftVue was developed by Delphinus Medical Technologies and builds on an early prototype developed at the Karmanos Cancer Institute. We present results from preliminary testing of the SoftVue system, performed both in the lab and in the clinic. These tests aimed to validate the expected improvements in image performance. Initial qualitative analyses showed major improvements in image quality, thereby validating the new imaging system design. Specifically, SoftVue's imaging performance was consistent across all breast density categories and had much better resolution and contrast. The implications of these results for clinical breast imaging are discussed and future work is described.

9.
Proc SPIE Int Soc Opt Eng ; 8675: 86751E, 2013 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-25426270

RESUMEN

Women with high breast density have an increased risk of developing breast cancer. Women treated with the selective estrogen receptor modulator tamoxifen for estrogen receptor positive breast cancer experience a 50% reduction in risk of contralateral breast cancer and overall reduction of similar magnitude has been identified among high-risk women receiving the drug for prevention. Tamoxifen has been shown to reduce mammographic density, and in the IBIS-1 chemoprevention trial, risk reduction and decline in density were significantly associated. Ultrasound tomography (UST) is an imaging modality that can create tomographic sound speed images of the breast. These sound speed images are useful because breast density is proportional to sound speed. The aim of this work is to examine the relationship between UST-measured breast density and the use of tamoxifen. So far, preliminary results for a small number of patients have been observed and are promising. Correlations between the UST-measured density and mammographic density are strong and positive, while relationships between UST density with some patient specific risk factors behave as expected. Initial results of UST examinations of tamoxifen treated patients show that approximately 45% of the patients have a decrease in density in the contralateral breast after only several months of treatment. The true effect of tamoxifen on UST-measured density cannot yet be fully determined until more data are collected. However, these promising results suggest that UST can be used to reliably assess quantitative changes in breast density over short intervals and therefore suggest that UST may enable rapid assessment of density changes associated with therapeutic and preventative interventions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...