Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Lancet Oncol ; 24(5): 457-467, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37062295

RESUMEN

BACKGROUND: Targeted real-time imaging during robot-assisted radical prostatectomy provides information on the localisation and extent of prostate cancer. We assessed the safety and feasibility of the prostate-specific membrane antigen (PSMA)-targeted fluorescent tracer OTL78 in patients with prostate cancer. METHODS: In this single-arm, phase 2a, feasibility trial with an adaptive design was carried out in The Netherlands Cancer Institute, Netherlands. Male patients aged 18 years or older, with PSMA PET-avid prostate cancer with an International Society of Urological Pathology (ISUP) grade group of 2 or more, who were scheduled to undergo robot-assisted radical prostatectomy with or without extended pelvic lymph node dissection were eligible. All patients had a robot-assisted radical prostatectomy using OTL78. Based on timing and dose, patients received a single intravenous infusion of OTL78 (0·06 mg/kg 1-2 h before surgery [dose cohort 1], 0·03 mg/kg 1-2 h before surgery [dose cohort 2], or 0·03 mg/kg 24 h before surgery [dose cohort 3]). The primary outcomes, assessed in all enrolled patients, were safety and pharmacokinetics of OTL78. This study is completed and is registered in the European Trial Database, 2019-002393-31, and the International Clinical Trials Registry Platform, NL8552, and is completed. FINDINGS: Between June 29, 2020, and April 1, 2021, 19 patients were screened for eligibility, 18 of whom were enrolled. The median age was 69 years (IQR 64-70) and median prostate-specific antigen concentration was 15 ng/mL (IQR 9·3-22·0). In 16 (89%) of 18 patients, robot-assisted radical prostatectomy was accompanied by an extended pelvic lymph node dissection. Three serious adverse events occurred in one (6%) patient: an infected lymphocele, a urosepsis, and an intraperitoneal haemorrhage. These adverse events were considered unrelated to the administration of OTL78 or intraoperative fluorescence imaging. No patient died, required a dose reduction, or required discontinuation due to drug-related toxicity. The dose-normalised maximum serum concentration (Cmax/dose) in patients was 84·1 ng/mL/mg for the 0·03 mg/kg dose and 79·6 ng/mL/mg for the 0·06 mg/kg dose, the half-life was 5·1 h for the 0·03 mg/kg dose and 4·7 h for the 0·06 mg/kg dose, the volume of distribution was 22·9 L for the 0·03 mg/kg dose and 19·5 L for the 0·06 mg/kg dose, and the clearance was 3·1 L/h for the 0·03 mg/kg dose and 3·0 L/h for the 0·06 mg/kg dose. INTERPRETATION: This first-in-patient study showed that OTL78 was well tolerated and had the potential to improve prostate cancer detection. Optimal dosing was 0·03 mg/kg, 24 h preoperatively. PSMA-directed fluorescence imaging allowed real-time identification of visually occult prostate cancer and might help to achieve complete oncological resections. FUNDING: On Target Laboratories.


Asunto(s)
Próstata , Neoplasias de la Próstata , Humanos , Masculino , Anciano , Próstata/patología , Estudios de Factibilidad , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Antígeno Prostático Específico , Prostatectomía/efectos adversos , Imagen Óptica , Tomografía Computarizada por Tomografía de Emisión de Positrones
2.
Mol Imaging Biol ; 25(1): 122-132, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-34642899

RESUMEN

PURPOSE: Radical resection is paramount for curative oncological surgery. Fluorescence-guided surgery (FGS) aids in intraoperative identification of tumor-positive resection margins. This study aims to assess the feasibility of urokinase plasminogen activator receptor (uPAR) targeting antibody fragments for FGS in a direct comparison with their parent IgG in various relevant in vivo models. PROCEDURES: Humanized anti-uPAR monoclonal antibody MNPR-101 (uIgG) was proteolytically digested into F(ab')2 and Fab fragments named uFab2 and uFab. Surface plasmon resonance (SPR) and cell assays were used to determine in vitro binding before and after fluorescent labeling with IRDye800CW. Mice bearing subcutaneous HT-29 human colonic cancer cells were imaged serially for up to 120 h after fluorescent tracer administration. Imaging characteristics and ex vivo organ biodistribution were further compared in orthotopic pancreatic ductal adenocarcinoma (BxPc-3-luc2), head-and-neck squamous cell carcinoma (OSC-19-luc2-GFP), and peritoneal carcinomatosis (HT29-luc2) models using the clinical Artemis fluorescence imaging system. RESULTS: Unconjugated and conjugated uIgG, uFab2, and uFab specifically recognized uPAR in the nanomolar range as determined by SPR and cell assays. Subcutaneous tumors were clearly identifiable with tumor-to-background ratios (TBRs) > 2 after 72 h for uIgG-800F and 24 h for uFab2-800F and uFab-800F. For the latter two, mean fluorescence intensities (MFIs) dipped below predetermined threshold after 72 h and 36 h, respectively. Tumors were easily identified in the orthotopic models with uIgG-800F consistently having the highest MFIs and uFab2-800F and uFab-800F having similar values. In biodistribution studies, kidney and liver fluorescence approached tumor fluorescence after uIgG-800F administration and surpassed tumor fluorescence after uFab2-800F or uFab-800F administration, resulting in interference in the abdominal orthotopic mouse models. CONCLUSIONS: In a side-by-side comparison, FGS with uPAR-targeting antibody fragments compared with the parent IgG resulted in earlier tumor visualization at the expense of peak fluorescence intensity.


Asunto(s)
Neoplasias Pancreáticas , Receptores del Activador de Plasminógeno Tipo Uroquinasa , Animales , Humanos , Ratones , Anticuerpos Monoclonales Humanizados , Línea Celular Tumoral , Colorantes Fluorescentes , Fragmentos Fab de Inmunoglobulinas , Inmunoglobulina G , Imagen Óptica/métodos , Neoplasias Pancreáticas/patología , Distribución Tisular
3.
Mol Imaging Biol ; 25(1): 228-239, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36575340

RESUMEN

PURPOSE: Intraoperative identification of lung tumors can be challenging. Tumor-targeted fluorescence-guided surgery can provide surgeons with a tool for real-time intraoperative tumor detection. This study evaluated cell surface biomarkers, partially selected via data-driven selection software, as potential targets for fluorescence-guided surgery in non-small cell lung cancers: adenocarcinomas (ADC), adenocarcinomas in situ (AIS), and squamous cell carcinomas (SCC). PROCEDURES: Formalin-fixed paraffin-embedded tissue slides of resection specimens from 15 patients with ADC and 15 patients with SCC were used and compared to healthy tissue. Molecular targets were selected based on two strategies: (1) a data-driven selection using > 275 multi-omics databases, literature, and experimental evidence; and (2) the availability of a fluorescent targeting ligand in advanced stages of clinical development. The selected targets were carbonic anhydrase 9 (CAIX), collagen type XVII alpha 1 chain (collagen XVII), glucose transporter 1 (GLUT1), G protein-coupled receptor 87 (GPR87), transmembrane protease serine 4 (TMPRSS4), carcinoembryonic antigen (CEA), epithelial cell adhesion molecule (EpCAM), folate receptor alpha (FRα), integrin αvß6 (αvß6), and urokinase-type plasminogen activator receptor (uPAR). Tumor expression of these targets was assessed by immunohistochemical staining. A total immunostaining score (TIS, range 0-12), combining the percentage and intensity of stained cells, was calculated. The most promising targets in ADC were explored in six AIS tissue slides to explore its potential in non-palpable lesions. RESULTS: Statistically significant differences in TIS between healthy lung and tumor tissue for ADC samples were found for CEA, EpCAM, FRα, αvß6, CAIX, collagen XVII, GLUT-1, and TMPRSS4, and of these, CEA, CAIX, and collagen XVII were also found in AIS. For SCC, EpCAM, uPAR, CAIX, collagen XVII, and GLUT-1 were found to be overexpressed. CONCLUSIONS: EpCAM, CAIX, and Collagen XVII were identified using concomitant use of data-driven selection software and clinical evidence as promising targets for intraoperative fluorescence imaging for both major subtypes of non-small cell lung carcinomas.


Asunto(s)
Adenocarcinoma , Carcinoma de Pulmón de Células no Pequeñas , Carcinoma de Células Escamosas , Neoplasias Pulmonares , Humanos , Carcinoma de Pulmón de Células no Pequeñas/patología , Neoplasias Pulmonares/patología , Antígeno Carcinoembrionario , Molécula de Adhesión Celular Epitelial , Fluorescencia , Receptores del Ácido Lisofosfatídico
4.
Cancers (Basel) ; 14(24)2022 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-36551695

RESUMEN

Current imaging modalities frequently misjudge disease stage in colorectal, gastric and pancreatic cancer. As treatment decisions are dependent on disease stage, incorrect staging has serious consequences. Previous preclinical research and case reports indicate that prostate-specific membrane antigen (PSMA)-targeted PET/CT imaging might provide a solution to some of these challenges. This prospective clinical study aims to assess the feasibility of [18F]DCFPyL PET/CT imaging to target and visualize primary colon, gastric and pancreatic cancer. In this prospective clinical trial, patients with colon, gastric and pancreatic cancer were included and underwent both [18F]DCFPyL and [18F]FDG PET/CT scans prior to surgical resection or (for gastric cancer) neoadjuvant therapy. Semiquantitative analysis of immunohistochemical PSMA staining was performed on the surgical resection specimens, and the results were correlated to imaging parameters. The results of this study demonstrate detection of the primary tumor by [18F]DCFPyL PET/CT in 7 out of 10 patients with colon, gastric and pancreatic cancer, with a mean tumor-to-blood pool ratio (TBR) of 3.3 and mean SUVmax of 3.6. However, due to the high surrounding uptake, visual distinction of these tumors was difficult, and the SUVmax and TBR on [18F]FDG PET/CT were significantly higher than on [18F]DCFPyL PET/CT. In addition, no correlation between PSMA expression in the resection specimen and SUVmax on [18F]DCFPyL PET/CT was found. In conclusion, the detection of several gastrointestinal cancers using [18F]DCFPyL PET/CT is feasible. However, low tumor expression and high uptake physiologically in organs/background hamper the clear distinction of the tumor. As a result, [18F]FDG PET/CT was superior in detecting colon, gastric and pancreatic cancers.

5.
Methods Mol Biol ; 2451: 547-556, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35505031

RESUMEN

Photodynamic therapy (PDT) is characterized by the local application of laser light, which activates a photosensitizer to lead to the formation of singlet oxygen and other toxic reactive oxygen species, to finally kill cells. Recently, photosensitizers have been conjugated to nanobodies to render PDT more selective to cancer cells. Nanobodies are the smallest naturally derived antibody fragments from heavy-chain antibodies that exist in animals of the Camelidae family. Indeed, we have shown that nanobody-targeted PDT can lead to extensive and selective tumor damage, and thus the subsequent step is to assess whether this damage can delay or even inhibit tumor growth in vivo. To evaluate the therapeutic efficacy of PDT, mouse models are mostly employed in which human tumors are grown subcutaneously in the flank of the animals. Although very useful, it has been suggested that these tumors are further away from their natural environment and that tumors developed in the organ or tissue of origin would be closer to the natural situation. Thus, this chapter describes the development of an orthotopic model of breast cancer and the application of nanobody-targeted PDT, for the assessment of the therapeutic efficacy.


Asunto(s)
Neoplasias de la Mama , Fotoquimioterapia , Anticuerpos de Dominio Único , Animales , Neoplasias de la Mama/tratamiento farmacológico , Femenino , Humanos , Luz , Ratones , Fármacos Fotosensibilizantes/farmacología , Fármacos Fotosensibilizantes/uso terapéutico , Anticuerpos de Dominio Único/farmacología , Anticuerpos de Dominio Único/uso terapéutico
6.
Eur J Cancer ; 146: 11-20, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33561783

RESUMEN

With a 5-year recurrence rate of 30-78%, urothelial cell carcinoma (UCC) rates amongst the highest of all solid malignancies. Consequently, after transurethral resection, patients are subjugated to life-long endoscopic surveillance. A multimodal near-infrared (NIR) fluorescence-based imaging strategy can improve diagnosis, resection and surveillance, hence increasing quality of life. METHODS: Expression of urokinase plasminogen activator receptor (uPAR) and epithelial cell adhesion molecule (EpCAM) are determined on paraffin-embedded human UCC using immunohistochemistry and on UCC cell lines by flow cytometry. MNPR-101, a humanised monoclonal antibody targeting uPAR is conjugated to IRDye800CW and binding is validated in vitro using surface plasmon resonance and cell-based binding assays. In vivo NIR fluorescence and photoacoustic three-dimensional (3D) imaging are performed with subcutaneously growing human UM-UC-3luc2 cells in BALB/c-nude mice. The translational potential is confirmed in a metastasising UM-UC-3luc2 orthotopic mouse model. Infliximab-IRDye800CW and rituximab-IRDye800CW are used as controls. RESULTS: UCCs show prominent uPAR expression at the tumour-stroma interface and EpCAM on epithelial cells. uPAR and EpCAM are expressed by 6/7 and 4/7 UCC cell lines, respectively. In vitro, MNPR-101-IRDye800CW has a picomolar affinity for domain 2-3 of uPAR. In vivo fluorescence imaging with MNPR-101-IRDye800CW, specifically delineates both subcutaneous and orthotopic tumours with tumour-to-background ratios reaching as high as 6.8, differing significantly from controls (p < 0.0001). Photoacoustic 3D in depth imaging confirms the homogenous distribution of MNPR-101-IRDye800CW through the tumour. CONCLUSIONS: MNPR-101-IRDye800CW is suitable for multimodal imaging of UCC, awaiting clinical translation.


Asunto(s)
Anticuerpos Monoclonales/farmacología , Imagen Molecular/métodos , Imagen Óptica/métodos , Receptores del Activador de Plasminógeno Tipo Uroquinasa/antagonistas & inhibidores , Cirugía Asistida por Computador/métodos , Neoplasias de la Vejiga Urinaria/diagnóstico , Animales , Apoptosis , Proliferación Celular , Femenino , Humanos , Ratones , Ratones Endogámicos BALB C , Ratones Desnudos , Pronóstico , Receptores del Activador de Plasminógeno Tipo Uroquinasa/inmunología , Receptores del Activador de Plasminógeno Tipo Uroquinasa/metabolismo , Células Tumorales Cultivadas , Neoplasias de la Vejiga Urinaria/inmunología , Neoplasias de la Vejiga Urinaria/cirugía , Ensayos Antitumor por Modelo de Xenoinjerto
7.
Ann Surg Oncol ; 28(3): 1832-1844, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33034788

RESUMEN

BACKGROUND: Carcinoembryonic antigen is overexpressed in colorectal cancer (CRC), making it an optimal target for fluorescence imaging. A phase I/II study was designed to determine the optimal imaging dose of SGM-101 for intraoperative fluorescence imaging of primary and recurrent CRC. METHODS: Patients were included and received a single dose of SGM-101 at least 24 h before surgery. Patients who received routine anticancer therapy (i.e., radiotherapy or chemotherapy) also were eligible. A dedicated near-infrared imaging system was used for real-time fluorescence imaging during surgery. Safety assessments were performed and SGM-101 efficacy was evaluated per dose level to determine the most optimal imaging dose. RESULTS: Thirty-seven patients with CRC were included in the analysis. Fluorescence was visible in all primary and recurrent tumors. In seven patients, no fluorescence was seen; all were confirmed as pathological complete responses after neoadjuvant therapy. Two tumors showed false-positive fluorescence. In the 37 patients, a total of 97 lesions were excised. The highest mean intraoperative tumor-to-background ratio (TBR) of 1.9 (p = 0.019) was seen in the 10-mg dose. This dose showed a sensitivity of 96%, specificity of 63%, and negative predictive value of 94%. Nine patients (24%) had a surgical plan alteration based on fluorescence, with additional malignant lesions detected in six patients. CONCLUSIONS: The optimal imaging dose was established at 10 mg 4 days before surgery. The results accentuate the potential of SGM-101 and designated a promising base for the multinational phase III study, which enrolled the first patients in June 2019.


Asunto(s)
Neoplasias Colorrectales , Anciano , Antígeno Carcinoembrionario , Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/tratamiento farmacológico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/diagnóstico por imagen , Imagen Óptica
8.
Eur J Surg Oncol ; 47(3 Pt B): 667-673, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33158638

RESUMEN

BACKGROUND: Fluorescence-guided surgery can provide surgeons with an imaging tool for real-time intraoperative tumor detection. SGM-101, an anti-CEA antibody labelled with a fluorescent dye, is a tumor-specific imaging agent that can aid in improving detection and complete resection for CEA-positive tumors. In this study, the performance of SGM-101 for the detection of colorectal and pancreatic liver metastases was investigated. METHODS: In this open-label, non-randomized, single-arm pilot study, patients were included with liver metastases from colorectal origin and intraoperatively detected liver metastases from pancreatic origin (during planned pancreatic surgery). SGM-101 was administered two to four days before the scheduled surgery as a single intravenous injection. Intraoperative fluorescence imaging was performed using the Quest Spectrum® imaging system. The performance of SGM-101 was assessed by measuring the intraoperative fluorescence signal and comparing this to histopathology. RESULTS: A total of 19 lesions were found in 11 patients, which were all suspected as malignant in white light and subsequent fluorescence inspection. Seventeen lesions were malignant with a mean tumor-to-background ratio of 1.7. The remaining two lesions were false-positives as proven by histology. CONCLUSION: CEA-targeted fluorescence-guided intraoperative tumor detection with SGM-101 is feasible for the detection of colorectal and pancreatic liver metastases.


Asunto(s)
Adenocarcinoma/secundario , Antígeno Carcinoembrionario/metabolismo , Neoplasias Colorrectales/patología , Técnica del Anticuerpo Fluorescente/métodos , Neoplasias Hepáticas/secundario , Imagen Molecular/métodos , Imagen Óptica/métodos , Neoplasias Pancreáticas/patología , Adenocarcinoma/diagnóstico , Adenocarcinoma/metabolismo , Adulto , Anciano , Anticuerpos Monoclonales , Antígeno Carcinoembrionario/inmunología , Neoplasias Colorrectales/metabolismo , Neoplasias Colorrectales/cirugía , Femenino , Colorantes Fluorescentes , Humanos , Periodo Intraoperatorio , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/cirugía , Masculino , Persona de Mediana Edad , Neoplasias Pancreáticas/metabolismo , Neoplasias Pancreáticas/cirugía , Proyectos Piloto
9.
Sci Rep ; 10(1): 17667, 2020 10 19.
Artículo en Inglés | MEDLINE | ID: mdl-33077751

RESUMEN

Neuroblastoma resection represents a major challenge in pediatric surgery, because of the high risk of complications. Fluorescence-guided surgery (FGS) could lower this risk by facilitating discrimination of tumor from normal tissue and is gaining momentum in adult oncology. Here, we provide the first molecular-targeted fluorescent agent for FGS in pediatric oncology, by developing and preclinically evaluating a GD2-specific tracer consisting of the immunotherapeutic antibody dinutuximab-beta, recently approved for neuroblastoma treatment, conjugated to near-infrared (NIR) fluorescent dye IRDye800CW. We demonstrated specific binding of anti-GD2-IRDye800CW to human neuroblastoma cells in vitro and in vivo using xenograft mouse models. Furthermore, we defined an optimal dose of 1 nmol, an imaging time window of 4 days after administration and show that neoadjuvant treatment with anti-GD2 immunotherapy does not interfere with fluorescence imaging. Importantly, as we observed universal, yet heterogeneous expression of GD2 on neuroblastoma tissue of a wide range of patients, we implemented a xenograft model of patient-derived neuroblastoma organoids with differential GD2 expression and show that even low GD2 expressing tumors still provide an adequate real-time fluorescence signal. Hence, the imaging advancement presented in this study offers an opportunity for improving surgery and potentially survival of a broad group of children with neuroblastoma.


Asunto(s)
Bencenosulfonatos/uso terapéutico , Neoplasias Encefálicas/cirugía , Colorantes Fluorescentes/uso terapéutico , Gangliósidos/metabolismo , Indoles/uso terapéutico , Neuroblastoma/cirugía , Animales , Neoplasias Encefálicas/metabolismo , Línea Celular Tumoral , Femenino , Citometría de Flujo , Humanos , Ratones , Ratones Desnudos , Trasplante de Neoplasias , Neoplasias Experimentales , Neuroblastoma/metabolismo , Análisis de Matrices Tisulares
10.
Mol Imaging Biol ; 22(6): 1511-1522, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32780212

RESUMEN

PURPOSE: Aberrantly expressed glycans in cancer are of particular interest for tumor targeting. This proof-of-concept in vivo study aims to validate the use of aberrant Lewis glycans as target for antibody-based, real-time imaging of gastrointestinal cancers. PROCEDURES: Immunohistochemical (IHC) staining with monoclonal antibody FG88.2, targeting Lewisa/c/x, was performed on gastrointestinal tumors and their healthy counterparts. Then, FG88.2 and its chimeric human/mouse variant CH88.2 were conjugated with near-infrared fluorescent (NIRF) IRDye 800CW for real-time imaging. Specific binding was evaluated in vitro on human gastrointestinal cancer cell lines with cell-based plate assays, flow cytometry, and immune-fluorescence microscopy. Subsequently, mice bearing human colon and pancreatic subcutaneous tumors were imaged in vivo after intravenous administration of 1 nmol (150 µg) CH88.2-800CW with the clinical Artemis NIRF imaging system using the Pearl Trilogy small animal imager as reference. One week post-injection of the tracer, tumors and organs were resected and tracer uptake was analyzed ex vivo. RESULTS: IHC analysis showed strong FG88.2 staining on colonic, gastric, and pancreatic tumors, while staining on their normal tissue counterparts was limited. Next, human cancer cell lines HT-29 (colon) and BxPC-3 and PANC-1 (both pancreatic) were identified as respectively high, moderate, and low Lewisa/c/x-expressing. Using the clinical NIRF camera system for tumor-bearing mice, a mean tumor-to-background ratio (TBR) of 2.2 ± 0.3 (Pearl: 3.1 ± 0.8) was observed in the HT-29 tumors and a TBR of 1.8 ± 0.3 (Pearl: 1.9 ± 0.5) was achieved in the moderate expression BxPC-3 model. In both models, tumors could be adequately localized and delineated by NIRF for up to 1 week. Ex vivo analysis confirmed full tumor penetration of the tracer and low fluorescence signals in other organs. CONCLUSIONS: Using a novel chimeric Lewisa/c/x-targeting tracer in combination with a clinical NIRF imager, we demonstrate the potential of targeting Lewis glycans for fluorescence-guided surgery of gastrointestinal tumors.


Asunto(s)
Neoplasias Gastrointestinales/diagnóstico por imagen , Polisacáridos/química , Prueba de Estudio Conceptual , Espectroscopía Infrarroja Corta , Animales , Anticuerpos Monoclonales/metabolismo , Bencenosulfonatos , Línea Celular Tumoral , Fluorescencia , Neoplasias Gastrointestinales/patología , Humanos , Indoles , Ratones
11.
Pharmaceuticals (Basel) ; 13(8)2020 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-32751634

RESUMEN

BACKGROUND: Targeted image-guided surgery is based on the detection of tumor cells after administration of a radio-active or fluorescent tracer. Hence, enhanced binding of a tracer to tumor tissue compared to healthy tissue is crucial. Various tumor antigens have been evaluated as possible targets for image-guided surgery of breast cancer, with mixed results. METHODS: In this study we have evaluated tyrosine kinase receptor EphB4, a member from the Eph tyrosine kinase receptor family, as a possible target for image-guided surgery of breast cancers. Two independent tissue micro arrays, consisting of matched sets of tumor and normal breast tissue, were stained for EphB4 by immunohistochemistry. The intensity of staining and the percentage of stained cells were scored by two independent investigators. RESULTS: Immunohistochemical staining for EphB4 shows that breast cancer cells display enhanced membranous expression compared to adjacent normal breast tissue. The enhanced tumor staining is not associated with clinical variables like age of the patient or stage or subtype of the tumor, including Her2-status. CONCLUSION: These data suggest that EphB4 is a promising candidate for targeted image-guided surgery of breast cancer, especially for Her2 negative cases.

12.
Clin Cancer Res ; 26(15): 3990-3998, 2020 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-32345649

RESUMEN

PURPOSE: Incomplete oncologic resections and damage to vital structures during colorectal cancer surgery increases morbidity and mortality. Moreover, neoadjuvant chemoradiotherapy has become the standard treatment modality for locally advanced rectal cancer, where subsequent downstaging can make identification of the primary tumor more challenging during surgery. Near-infrared (NIR) fluorescence imaging can aid surgeons by providing real-time visualization of tumors and vital structures during surgery. EXPERIMENTAL DESIGN: We present the first-in-human clinical experience of a novel NIR fluorescent peptide, cRGD-ZW800-1, for the detection of colon cancer. cRGD-ZW800-1 was engineered to have an overall zwitterionic chemical structure and neutral charge to lower nonspecific uptake and thus background fluorescent signal. We performed a phase I study in 11 healthy volunteer as well as a phase II feasibility study in 12 patients undergoing an elective colon resection, assessing 0.005, 0.015, and 0.05 mg/kg cRGD-ZW800-1 for the intraoperative visualization of colon cancer. RESULTS: cRGD-ZW800-1 appears safe, and exhibited rapid elimination into urine after a single low intravenous dose. Minimal invasive intraoperative visualization of colon cancer through full-thickness bowel wall was possible after an intravenous bolus injection of 0.05 mg/kg at least 2 hours prior to surgery. Longer intervals between injection and imaging improved the tumor-to-background ratio. CONCLUSIONS: cRGD-ZW800-1 enabled fluorescence imaging of colon cancer in both open and minimal invasive surgeries. Further development of cRGD-ZW800-1 for widespread use in cancer surgery may be warranted given the ubiquitous overexpression of various integrins on different types of tumors and their vasculature.


Asunto(s)
Carcinoma/diagnóstico , Colon/diagnóstico por imagen , Neoplasias del Colon/diagnóstico , Colorantes Fluorescentes/administración & dosificación , Imagen Óptica/métodos , Anciano , Anciano de 80 o más Años , Animales , Carcinoma/patología , Carcinoma/terapia , Quimioradioterapia Adyuvante , Colectomía/métodos , Colon/patología , Colon/cirugía , Neoplasias del Colon/patología , Neoplasias del Colon/terapia , Estudios de Factibilidad , Femenino , Colorantes Fluorescentes/efectos adversos , Colorantes Fluorescentes/química , Colorantes Fluorescentes/farmacocinética , Voluntarios Sanos , Humanos , Integrinas/metabolismo , Masculino , Ratones , Persona de Mediana Edad , Terapia Neoadyuvante , Imagen Óptica/efectos adversos , Péptidos Cíclicos/administración & dosificación , Péptidos Cíclicos/efectos adversos , Péptidos Cíclicos/química , Péptidos Cíclicos/farmacocinética , Compuestos de Amonio Cuaternario/administración & dosificación , Compuestos de Amonio Cuaternario/efectos adversos , Compuestos de Amonio Cuaternario/química , Compuestos de Amonio Cuaternario/farmacocinética , Ratas , Espectroscopía Infrarroja Corta/métodos , Ácidos Sulfónicos/administración & dosificación , Ácidos Sulfónicos/efectos adversos , Ácidos Sulfónicos/química , Ácidos Sulfónicos/farmacocinética , Pruebas de Toxicidad Aguda
13.
Front Oncol ; 10: 586112, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33392081

RESUMEN

Assessing lymph node (LN) status during tumor resection is fundamental for the staging of colorectal cancer. Current guidelines require a minimum of 12 LNs to be harvested during resection and ultra-staging regional lymph nodes by sentinel lymph node (SLN) assessment is being extensively investigated. The current study presents novel near-infrared (NIR) fluorescent dyes for simultaneous pan lymph node (PanLN; regional) and SLN mapping. PanLN-Forte was intravenously injected in mice and assessed for accumulation in regional LNs. SLN800 was injected intradermally in mice, after which the collection and retention of fluorescence in SLNs were measured using indocyanine green (ICG) and its precursor, SLN700, as references. LNs in the cervical, inguinal, jejunal, iliac, and thoracic basins could clearly be distinguished after a low dose intravenous injection of PanLN-Forte. Background fluorescence was significantly lower compared to the parent compound ZW800-3A (p < 0.001). SLN700 and SLN800 specifically targeted SLNs with fluorescence being retained over 40-fold longer than the current clinically used agent ICG. Using SLN700 and SLN800, absolute fluorescence in SLN was at least 10 times higher than ICG in second-tier nodes, even at 1 hour post-injection. Histologically, the fluorescent signal localized in the LN medulla (PanLN-Forte) or sinus entry (SLN700/SLN800). PanLN-Forte and SLN800 appear to be optimal for real-time NIR fluorescence imaging of regional and SLNs, respectively.

14.
Oral Oncol ; 78: 1-7, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29496035

RESUMEN

OBJECTIVES: Tumour-positive resection margins are a major problem during oral cancer surgery. gGlu-HMRG is a tracer that becomes fluorescent upon activation by gamma-glutamyltranspeptidase (GGT). This study aims to investigate the combination of gGlu-HMRG and a clinical fluorescence imaging system for the detection of tumour-positive resection margins. MATERIALS AND METHODS: The preclinical Maestro and clinical Artemis imaging systems were compared in vitro and ex vivo with cultured human head and neck cancer cells (OSC19, GGT-positive; and FaDu, GGT negative) and tumour-bearing nude mice. Subsequently, frozen sections of normal and oral cancer tissues were ex vivo sprayed with gGlu-HMRG to determine the sensitivity and specificity. Finally, resection margins of patients with suspected oral cancer were ex vivo sprayed with gGlu-HMRG to detect tumour-positive resection margins. RESULTS: Both systems could be used to detect gGlu-HMRG activation in vitro and ex vivo in GGT positive cancer cells. Sensitivity and specificity of gGlu-HMRG and the Artemis on frozen tissue samples was 80% and 87%, respectively. Seven patients undergoing surgery for suspected oral cancer were included. In three patients fluorescence was observed at the resection margin. Those margins were either tumour-positive or within 1 mm of tumour. The margins of the other patients were clear (≥8 mm). CONCLUSION: This study demonstrates the feasibility to detect tumour-positive resection margins with gGlu-HMRG and a clinical fluorescence imaging system. Applying this technique would enable intraoperative screening of the entire resection margin and allow direct re-resection in case of tumour-positivity.


Asunto(s)
Carcinoma de Células Escamosas/cirugía , Colorantes Fluorescentes/administración & dosificación , Márgenes de Escisión , Neoplasias de la Boca/cirugía , gamma-Glutamiltransferasa/metabolismo , Animales , Femenino , Colorantes Fluorescentes/metabolismo , Xenoinjertos , Humanos , Ratones , Ratones Endogámicos BALB C , Ratones Desnudos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...