Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38696672

RESUMEN

Objective: To evaluate the safety and explore the efficacy of use of ultra-rapid lispro (URLi, Lyumjev) insulin in the Tandem t:slim X2 insulin pump with Control-IQ 1.5 technology in children, teenagers, and adults living with type 1 diabetes (T1D). Methods: At 14 U.S. diabetes centers, youth and adults with T1D completed a 16-day lead-in period using lispro in a t:slim X2 insulin pump with Control-IQ 1.5 technology, followed by a 13-week period in which URLi insulin was used in the pump. Results: The trial included 179 individuals with T1D (age 6-75 years). With URLi, 1.7% (3 participants) had a severe hypoglycemia event over 13 weeks attributed to override boluses or a missed meal. No diabetic ketoacidosis events occurred. Two participants stopped URLi use because of infusion-site discomfort, and one stopped after developing a rash. Mean time 70-180 mg/dL increased from 65% ± 15% with lispro to 67% ± 13% with URLi (P = 0.004). Mean insulin treatment satisfaction questionnaire score improved from 75 ± 13 at screening to 80 ± 11 after 13 weeks of URLi use (mean difference = 6; 95% confidence interval 4-8; P < 0.001), with the greatest improvement reported for confidence avoiding symptoms of high blood sugar. Mean treatment-related impact measure-diabetes score improved from 74 ± 12 to 80 ± 12 (P < 0.001), and mean TRIM-Diabetes Device (score improved from 82 ± 11 to 86 ± 12 (P < 0.001). Conclusions: URLi use in the Tandem t:slim X2 insulin pump with Control-IQ 1.5 technology was safe for adult and pediatric participants with T1D, with quality-of-life benefits of URLi use perceived by the study participants. Clinicaltrials.gov registration: NCT05403502.

2.
Diabetes Technol Ther ; 26(1): 11-23, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37850941

RESUMEN

Background: The Omnipod® 5 Automated Insulin Delivery (AID) System was shown to be safe and effective following 3 months of use in people with type 1 diabetes (T1D); however, data on the durability of these results are limited. This study evaluated the long-term safety and effectiveness of Omnipod 5 use in people with T1D during up to 2 years of use. Materials and Methods: After a 3-month single-arm, multicenter, pivotal trial in children (6-13.9 years) and adolescents/adults (14-70 years), participants could continue system use in an extension phase. HbA1c was measured every 3 months for up to 15 months; continuous glucose monitor metrics were collected for up to 2 years. Results: Participants (N = 224) completed median (interquartile range) 22.3 (21.7, 22.7) months of AID. HbA1c was reduced in the pivotal trial from 7.7% ± 0.9% in children and 7.2% ± 0.9% in adolescents/adults to 7.0% ± 0.6% and 6.8% ± 0.7%, respectively, (P < 0.0001), and was maintained at 7.2% ± 0.7% and 6.9% ± 0.6% after 15 months (P < 0.0001 from baseline). Time in target range (70-180 mg/dL) increased from 52.4% ± 15.6% in children and 63.6% ± 16.5% in adolescents/adults at baseline to 67.9% ± 8.0% and 73.8% ± 10.8%, respectively, during the pivotal trial (P < 0.0001) and was maintained at 65.9% ± 8.9% and 72.9% ± 11.3% during the extension (P < 0.0001 from baseline). One episode of diabetic ketoacidosis and seven episodes of severe hypoglycemia occurred during the extension. Children and adolescents/adults spent median 96.1% and 96.3% of time in Automated Mode, respectively. Conclusion: Our study supports that long-term use of the Omnipod 5 AID System can safely maintain improvements in glycemic outcomes for up to 2 years of use in people with T1D. Clinical Trials Registration Number: NCT04196140.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Niño , Humanos , Adolescente , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Hemoglobina Glucada , Sistemas de Infusión de Insulina , Glucemia , Automonitorización de la Glucosa Sanguínea
3.
Diabetes Ther ; 14(11): 1933-1945, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37740871

RESUMEN

INTRODUCTION: To assess time in range (TIR) (70-180 mg/dL) with postprandial glucose (PPG)-focused titration of ultra rapid lispro (URLi; Lyumjev®) in combination with insulin degludec in people with type 1 diabetes (T1D). METHODS: This phase 2, single-group, open-label, exploratory study was conducted in 31 participants with T1D on multiple daily injection therapy. Participants were treated with insulin degludec and Lispro for an 11-day lead-in and then URLi for a 46-day treatment period consisting of 35-day titration and 11-day endpoint maintenance period. Glucose targets for the titration period were PPG < 140 mg/dL or < 20% increase from premeal, fasting glucose 80-110 mg/dL, and overnight excursion ± 30 mg/dL or less. Participants used the InPen™ bolus calculator and Dexcom G6 continuous glucose monitoring (CGM). RESULTS: Primary endpoint mean TIR (70-180 mg/dL) with URLi during the maintenance period was 70.2%. TIR (70-180 mg/dL) and times below/above range were not significantly different with URLi (maintenance) versus lispro (lead-in). HbA1c decreased from 7.1% at screening to 6.8% at endpoint (least squares mean [LSM] change from baseline, - 0.36%; P < 0.001). Fructosamine and 1,5-anhydroglucitol improved (P < 0.001). Mean hourly glucose using CGM was reduced from 8:00 AM to 4:00 PM with URLi. Overall highest PPG excursion across meals was significantly reduced at URLi endpoint compared with lispro lead-in (mean 56.5 vs 72.4 mg/dL; P < 0.001). Insulin-to-carbohydrate ratio (U/X g) was reduced (more insulin given) at breakfast at URLi endpoint vs lead-in (LSM 9.0 vs 9.7 g; P = 0.002) and numerically decreased at other meals. Total daily insulin dose (TDD) was higher at URLi endpoint compared with lispro lead-in (mean 50.2 vs 47.0 U; P = 0.046) with similar prandial/TDD ratio (mean 52.1% vs 51.2%). There were no severe hypoglycemia events during the study. CONCLUSIONS: URLi in a basal-bolus regimen focusing on PPG targets demonstrated improved overall glycemic control and reduced PPG excursions without increased hypoglycemia in participants with T1D. TRIAL REGISTRATION: ClinicalTrial.gov, NCT04585776.

4.
J Pharm Bioallied Sci ; 15(Suppl 2): S1347-S1350, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37694062

RESUMEN

The current study aims to present our clinical observations and experience gathered during the diagnosis, clinical presentation, medical/surgical treatment, and functional prosthetic rehabilitation of cases of rhino-orbital/cerebral Mucormycosis patients. Mucormycosis is an aggressive, life-threatening invasive fungal infection that occurs in people who are immune-compromised. The rise of ROCM during the second wave of the COVID-19 pandemic in India suggests a more effective association between Mucormycosis and the SARS-CoV-2 delta variant. The treatment strategy for Mucormycosis is an early diagnosis which is critical for a successful outcome. The initial step is to reduce or remove underlying risk factors followed by surgical excision and debridement of the afflicted tissues supplemented with antifungal medication. The first-line antifungal treatment is Liposomal Amphotericin B. Postsurgical resection defects are rehabilitated by either removable partial prosthesis (obturators) or by fixed zygomatic implant/patient-specific implant supported prosthesis. Management of ROCM requires a multidisciplinary approach. This case series highlights detailed medical, surgical, and functional prosthetic management modalities adopted by our team in managing such a dreaded disease which may be used as a tool for the formulation of standardized prevention and management/treatment/rehabilitation protocols in the future so that disease morbidity and mortality be reduced and an endemic outbreak could be averted.

5.
J Maxillofac Oral Surg ; 22(Suppl 1): 133-144, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37034447

RESUMEN

Removal of a part of or the entire orbit results in facial defect, causing psychological trauma to the patient, apart from anatomic loss. This case series presents 6 clinical cases of prosthetic rehabilitation of ocular defects related to post-COVID-19 ROCM by both analog and digital workflow. The basic objective of this case series was to achieve a well retained, user-friendly, maxillofacial ocular prosthesis with esthetic accuracy. Unique size and shape of the ocular defect in each case, variety of skin tones, age range of patients and compromised neuromuscular control made each of the six cases challenging. This clinical series apart from proposing a digital & analog algorithm for rehabilitating ocular defects also illustrates analog workflow for 4 cases and digital workflow for 2 cases for fabrication of ocular prosthesis.

6.
J Contemp Dent Pract ; 23(7): 743-748, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-36440523

RESUMEN

AIM: Aim of the present research was to compare the antimicrobial activity of Aloevera mouthwash with chlorhexidine mouthwash in fixed orthodontic patients. MATERIALS AND METHODS: A sample of 90 fixed Orthodontic patients participated in this study. Full-mouth oral prophylaxis was performed for every patient at the start of the study. Patients were advised to brush twice a day with the modified bass technique and rinse with respective mouthwashes for 20 days. Once the patients with fixed orthodontic appliances were accepted to participate in the study, they received dental prophylaxis which includes the removal of plaque, calculus, and stains from the teeth by scaling and polishing. Then they were randomly divided into the following three groups: chlorhexidine (group I), Aloevera (group II), and control (group III). A washout period of 8-10 days (baseline) was awaited post-oral prophylaxis and then the following clinical parameters were recorded: Plaque index (PI) and gingival index (GI). The data included clinical examination, inspection, and microscopic observation techniques. RESULTS: The mean reduction of the PI score on the 20th day of group II was 0.03 ± 0.18, group I was 0.43 ± 0.49, and the control group was 1.65 ± 0.88. The mean reduction of GI score on the 20th day of group II was 0.83 ± 0.40, group I was 0.93 ± 0.55, and group III was 1.85 ± 0.77. Student's t-test had been used to evaluate within each group between day 1 and day 20, group I and group II had shown higher differences compared to control. CONCLUSION: In conclusion, both chlorhexidine mouthwash and Aloevera mouthwash are important chemical adjuncts in controlling gingival inflammation, gingival bleeding, and plaque accumulation in orthodontic patients. Aloevera could be an alternative to chlorhexidine in patients who are seeking a chemical-free, indigenous, and patient-friendly oral hygiene aid. CLINICAL SIGNIFICANCE: Chlorhexidine is known to produce temporary tooth discoloration, allergic responses, dry mouth, burning in the mouth, and transient bad taste, which deter patients from using this mouthwash. The hunt for plant extract-based antimicrobial medicines has been prompted by the emergence of medication resistance and the unfavorable side effects of several antibiotics. These natural remedies can be a valuable substitute for creating a comparable effect.


Asunto(s)
Placa Dental , Gingivitis , Humanos , Clorhexidina/uso terapéutico , Placa Dental/prevención & control , Placa Dental/tratamiento farmacológico , Índice de Placa Dental , Gingivitis/prevención & control , Gingivitis/tratamiento farmacológico , Antisépticos Bucales/uso terapéutico
7.
J Contemp Dent Pract ; 23(6): 646-651, 2022 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-36259306

RESUMEN

AIM: To evaluate and compare the translucency of various commercially available zirconium oxide ceramic systems, i.e., Ceramill® Zolid Classic, Ceramill® Zi, and DD Bio ZX²71 by using a dual beam UV-visible spectrophotometer. MATERIALS AND METHODS: The present study comprised of 21 disk-shaped samples of zirconia for every group, i.e., group I-Ceramill® Zolid Classic, group II-Ceramill Zi®, and group III-DD Bio ZX²71. Furthermore, each group was split into three subgroups and every subgroup had seven samples each one of 0.7, 0.8, and 0.9 mm thickness. The samples were prepared by computer-aided design/computer-aided manufacturing (CAD/CAM) system devised by Amann Girrbach AG in accord with the steps provided by the manufacturer. The entire sample was designed having 10 mm in diameter with 0.7, 0.8, and 0.9 mm thickness for every group. The UV-visible dual beam spectrophotometer equipped with D2 lamp and W lamp was used for the measurement of absorbance and transmittance in order to assess the translucency of the fabricated zirconia samples. RESULTS: The mean value of transmittance % for Ceramill® Zi at 0.8 mm came out to be 0.849 ± 0.024, i.e., the least among all, whereas the mean value of Ceramill® Zolid Classic was 1.408 ± 0.033, being the highest for the same thickness. DD Bio ZX²71 had an intermediate value of 1.274 ± 0.012. The mean value of absorbance for Ceramill® Zi at 0.8 mm came out to be 2.086 ± 0.013, i.e., the maximum among all, whereas the mean value of Ceramill® Zolid Classic was, being the lowest for the same thickness. DD Bio ZX²71 had an intermediate value of 1.902 ± 0.004. CONCLUSION: The present study data suggest that all the materials subjected to evaluation exhibited a substantial translucency. We attempted to study few of the desirable properties, these materials should possess when used for prosthetic rehabilitation with esthetic contentment a clinical setup. There has been an ambiguous distinction that Ceramill® Zi Zirconia supersedes the Ceramill® Zolid Classic and DD Bio ZX²71. Furthermore, 0.8 mm thickness substantiates to be the most ideal among 0.7, 0.8, and 0.9 mm. CLINICAL SIGNIFICANCE: The desired outcome of the procedure becomes dependent solely on the clinician's judgment to opt for the material whose properties are most fitting as per the demands of the esthetics. While a clinician should always be ambitious, but a good clinician should also bear in mind that the success of any treatment procedure not only depends on the assortment of properties of these materials but also the host response and satisfaction evoked by these materials.


Asunto(s)
Porcelana Dental , Estética Dental , Ensayo de Materiales , Circonio , Cerámica , Diseño Asistido por Computadora , Propiedades de Superficie
8.
Diabetes Res Clin Pract ; 190: 109998, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35853530

RESUMEN

AIMS: To evaluate psychosocial outcomes for adults with type 1 diabetes (T1D) using the tubeless Omnipod® 5 Automated Insulin Delivery (AID) System. METHODS: A single-arm, multicenter (across the United States), prospective safety and efficacy study of the tubeless AID system included 115 adults with T1D. Participants aged 18-70 years completed questionnaires assessing psychosocial outcomes - diabetes distress (T1-DDS), hypoglycemic confidence (HCS), well-being (WHO-5), sleep quality (PSQI), insulin delivery satisfaction (IDSS), diabetes treatment satisfaction (DTSQ), and system usability (SUS) - before and after 3 months of AID use. Associations among participant characteristics, psychosocial measures and glycemic outcomes were evaluated using linear regression analyses. RESULTS: Adults using the tubeless AID system demonstrated improvements in diabetes-specific psychosocial measures, including diabetes distress, hypoglycemic confidence, insulin delivery satisfaction, diabetes treatment satisfaction, and system usability after 3 months (all P < 0.001). No changes in general well-being or sleep quality were observed. The psychosocial outcomes assessed were not consistently associated with baseline participant characteristics (i.e., age, sex, diabetes duration, glycemic outcomes including percent time in range 70-180 mg/dL, percent time below range < 70 mg/dL, hemoglobin A1c, or insulin regimen). CONCLUSIONS: Use of the Omnipod 5 AID system was associated with significant improvements in diabetes-related psychosocial outcomes for adults with T1D. CLINICAL TRIALS REGISTRATION NUMBER: NCT04196140.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/psicología , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Insulina Regular Humana/uso terapéutico , Estudios Prospectivos
9.
Diabetes Technol Ther ; 24(6): 424-434, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35294272

RESUMEN

Objective: To evaluate glycemic outcomes in the Wireless Innovation for Seniors with Diabetes Mellitus (WISDM) randomized clinical trial (RCT) participants during an observational extension phase. Research Design and Methods: WISDM RCT was a 26-week RCT comparing continuous glucose monitoring (CGM) with blood glucose monitoring (BGM) in 203 adults aged ≥60 years with type 1 diabetes. Of the 198 participants who completed the RCT, 100 (98%) CGM group participants continued CGM (CGM-CGM cohort) and 94 (98%) BGM group participants initiated CGM (BGM-CGM cohort) for an additional 26 weeks. Results: CGM was used a median of >90% of the time at 52 weeks in both cohorts. In the CGM-CGM cohort, median time <70 mg/dL decreased from 5.0% at baseline to 2.6% at 26 weeks and remained stable with a median of 2.8% at 52 weeks (P < 0.001 baseline to 52 weeks). Participants spent more time in range 70-180 mg/dL (TIR) (mean 56% vs. 64%; P < 0.001) and had lower hemoglobin A1c (HbA1c) (mean 7.6% [59 mmol/mol] vs. 7.4% [57 mmol/mol]; P = 0.01) from baseline to 52 weeks. In BGM-CGM, from 26 to 52 weeks median time <70 mg/dL decreased from 3.9% to 1.9% (P < 0.001), TIR increased from 56% to 60% (P = 0.006) and HbA1c decreased from 7.5% (58 mmol/mol) to 7.3% (57 mmol/mol) (P = 0.025). In BGM-CGM, a severe hypoglycemic event was reported for nine participants while using BGM during the RCT and for two participants during the extension phase with CGM (P = 0.02). Conclusions: CGM use reduced hypoglycemia without increasing hyperglycemia in older adults with type 1 diabetes. These data provide further evidence for fully integrating CGM into clinical practice. Clinicaltrials.gov (NCT03240432).


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Anciano , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada/análisis , Humanos , Hipoglucemia/prevención & control , Hipoglucemiantes/uso terapéutico
10.
Diabetes Technol Ther ; 24(8): 535-543, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35263188

RESUMEN

Background: Standard insulin infusion sets (IISs) are to be replaced every 2 to 3 days to avoid complications and diabetic ketosis due to set failure. This pivotal trial evaluated the safety and performance of a new extended-wear infusion set (EIS) when used for 7 days by adults with type 1 diabetes (T1D). Methods: This single-arm, nonrandomized trial enrolled adults (18-80 years of age) with T1D, who used their own MiniMed™ 670G system with insulin lispro or insulin aspart and the EIS for up to 7 days, across 12 consecutive wears. Safety endpoints included incidence of serious adverse events (SAEs), serious adverse device effects (SADEs), unanticipated adverse device effects (UADEs), severe hypoglycemia (SevHypo), severe hyperglycemia (SevHyper), diabetic ketoacidosis (DKA), and skin infection. The EIS failure rate due to unexplained hyperglycemia (i.e., suspected occlusion), the overall EIS survival rate, glycemic control outcomes (i.e., A1C, mean sensor glucose and time spent in established glucose ranges), total daily insulin delivered, and satisfaction with the EIS were determined. Results: The intention to treat population (n = 259, 48% men, 45.0 ± 14.1 years) wore a total of 3041 EIS devices. No SADE, UADE, or DKA events was reported. Overall rates of SAEs, SevHypo, SevHyper, and skin infection were 3.8, 2.5, 104.1, and 20.1 events per 100 participant-years. The rate of EIS failure due to unexplained hyperglycemia at the end of day 7 was 0.1% (95% confidence interval [CI]: 0.03-0.51) and 0.4% (95% CI: 0.16-1.00) for insulin lispro and aspart use, respectively. Overall EIS survival rate at the end of day 7 was 77.8% (95% CI: 76.2-79.3), glycemic control did not change, and participants reported greater satisfaction with the EIS compared with standard IISs worn before the study (P < 0.001). Conclusions: This investigation demonstrates that the EIS, when worn for up to 7 days, was safe and rated with high satisfaction, without adversely affecting glycemic control in adults with T1D. Clinical Trial Registration number: NCT04113694 (https://clinicaltrials.gov/ct2/show/NCT04113694).


Asunto(s)
Diabetes Mellitus Tipo 1 , Cetoacidosis Diabética , Hiperglucemia , Hipoglucemia , Adulto , Glucemia , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Cetoacidosis Diabética/inducido químicamente , Femenino , Humanos , Hiperglucemia/inducido químicamente , Hipoglucemia/inducido químicamente , Hipoglucemia/tratamiento farmacológico , Hipoglucemia/prevención & control , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Insulina Lispro/uso terapéutico , Masculino , Tasa de Supervivencia
11.
J Chem Phys ; 155(14): 144702, 2021 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-34654287

RESUMEN

Efforts to improve energy storage depend greatly on the development of efficient electrode materials. Recently, strain has been employed as an alternate approach to improve ion mobility. While lattice strain has been well-researched in catalytic applications, its effects on electrochemical energy storage are largely limited to computational studies due to complexities associated with strain control in nanomaterials as well as loss of strain due to the phase change of the active material during charging-discharging. In this work, we overcome these challenges and investigate the effects of strain on supercapacitor performance in Li-ion-based energy devices. We synthesize epitaxial Fe3O4@MnFe2O4 (core@shell) nanoparticles with varying shell thickness to control the lattice strain. A narrow voltage window for electrochemical testing is used to limit the storage mechanism to lithiation-delithiation, preventing a phase change and maintaining structural strain. Cyclic voltammetry reveals a pseudocapacitive behavior and similar levels of surface charge storage in both strained- and unstrained-MnFe2O4 samples; however, diffusive charge storage in the strained sample is twice as high as the unstrained sample. The strained-MnFe2O4 electrode exceeds the performance of the unstrained-MnFe2O4 electrode in energy density by ∼33%, power density by ∼28%, and specific capacitance by ∼48%. Density functional theory shows lower formation energies for Li-intercalation and lower activation barrier for Li-diffusion in strained-MnFe2O4, corresponding to a threefold increase in the diffusion coefficient. The enhanced Li-ion diffusion rate in the strained-electrodes is further confirmed using the galvanostatic intermittent titration technique. This work provides a starting point to using strain engineering as a novel approach for designing high performance energy storage devices.

12.
Diabetes Care ; 44(12): 2729-2737, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34588210

RESUMEN

OBJECTIVE: To explore the effect of discontinuing continuous glucose monitoring (CGM) after 8 months of CGM use in adults with type 2 diabetes treated with basal without bolus insulin. RESEARCH DESIGN AND METHODS: This multicenter trial had an initial randomization to either real-time CGM or blood glucose monitoring (BGM) for 8 months followed by 6 months in which the BGM group continued to use BGM (n = 57) and the CGM group was randomly reassigned either to continue CGM (n = 53) or discontinue CGM with resumption of BGM for glucose monitoring (n = 53). RESULTS: In the group that discontinued CGM, mean time in range (TIR) 70-180 mg/dL, which improved from 38% before initiating CGM to 62% after 8 months of CGM, decreased after discontinuing CGM to 50% at 14 months (mean change from 8 to 14 months -12% [95% CI -21% to -3%], P = 0.01). In the group that continued CGM use, little change was found in TIR from 8 to 14 months (baseline 44%, 8 months 56%, 14 months 57%, mean change from 8 to 14 months 1% [95% CI -11% to 12%], P = 0.89). Comparing the two groups at 14 months, the adjusted treatment group difference in mean TIR was -6% (95% CI -16% to 4%, P = 0.20). CONCLUSIONS: In adults with type 2 diabetes treated with basal insulin who had been using real-time CGM for 8 months, discontinuing CGM resulted in a loss of about one-half of the initial gain in TIR that had been achieved during CGM use.


Asunto(s)
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Adulto , Glucemia , Automonitorización de la Glucosa Sanguínea/métodos , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Hemoglobina Glucada/análisis , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico
13.
Diabetes Care ; 44(7): 1630-1640, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34099518

RESUMEN

OBJECTIVE: Advances in diabetes technology have transformed the treatment paradigm for type 1 diabetes, yet the burden of disease is significant. We report on a pivotal safety study of the first tubeless, on-body automated insulin delivery system with customizable glycemic targets. RESEARCH DESIGN AND METHODS: This single-arm, multicenter, prospective study enrolled 112 children (age 6-13.9 years) and 129 adults (age 14-70 years). A 2-week standard therapy phase (usual insulin regimen) was followed by 3 months of automated insulin delivery. Primary safety outcomes were incidence of severe hypoglycemia and diabetic ketoacidosis. Primary effectiveness outcomes were change in HbA1c and percent time in sensor glucose range 70-180 mg/dL ("time in range"). RESULTS: A total of 235 participants (98% of enrolled, including 111 children and 124 adults) completed the study. HbA1c was significantly reduced in children by 0.71% (7.8 mmol/mol) (mean ± SD: 7.67 ± 0.95% to 6.99 ± 0.63% [60 ± 10.4 mmol/mol to 53 ± 6.9 mmol/mol], P < 0.0001) and in adults by 0.38% (4.2 mmol/mol) (7.16 ± 0.86% to 6.78 ± 0.68% [55 ± 9.4 mmol/mol to 51 ± 7.4 mmol/mol], P < 0.0001). Time in range was improved from standard therapy by 15.6 ± 11.5% or 3.7 h/day in children and 9.3 ± 11.8% or 2.2 h/day in adults (both P < 0.0001). This was accomplished with a reduction in time in hypoglycemia <70 mg/dL among adults (median [interquartile range]: 2.00% [0.63, 4.06] to 1.09% [0.46, 1.75], P < 0.0001), while this parameter remained the same in children. There were three severe hypoglycemia events not attributable to automated insulin delivery malfunction and one diabetic ketoacidosis event from an infusion site failure. CONCLUSIONS: This tubeless automated insulin delivery system was safe and allowed participants to significantly improve HbA1c levels and time in target glucose range with a very low occurrence of hypoglycemia.


Asunto(s)
Diabetes Mellitus Tipo 1 , Insulina , Adolescente , Adulto , Anciano , Glucemia , Niño , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada/análisis , Humanos , Hipoglucemiantes , Sistemas de Infusión de Insulina , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
14.
JAMA ; 325(22): 2262-2272, 2021 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-34077499

RESUMEN

Importance: Continuous glucose monitoring (CGM) has been shown to be beneficial for adults with type 2 diabetes using intensive insulin therapy, but its use in type 2 diabetes treated with basal insulin without prandial insulin has not been well studied. Objective: To determine the effectiveness of CGM in adults with type 2 diabetes treated with basal insulin without prandial insulin in primary care practices. Design, Setting, and Participants: This randomized clinical trial was conducted at 15 centers in the US (enrollment from July 30, 2018, to October 30, 2019; follow-up completed July 7, 2020) and included adults with type 2 diabetes receiving their diabetes care from a primary care clinician and treated with 1 or 2 daily injections of long- or intermediate-acting basal insulin without prandial insulin, with or without noninsulin glucose-lowering medications. Interventions: Random assignment 2:1 to CGM (n = 116) or traditional blood glucose meter (BGM) monitoring (n = 59). Main Outcomes and Measures: The primary outcome was hemoglobin A1c (HbA1c) level at 8 months. Key secondary outcomes were CGM-measured time in target glucose range of 70 to 180 mg/dL, time with glucose level at greater than 250 mg/dL, and mean glucose level at 8 months. Results: Among 175 randomized participants (mean [SD] age, 57 [9] years; 88 women [50%]; 92 racial/ethnic minority individuals [53%]; mean [SD] baseline HbA1c level, 9.1% [0.9%]), 165 (94%) completed the trial. Mean HbA1c level decreased from 9.1% at baseline to 8.0% at 8 months in the CGM group and from 9.0% to 8.4% in the BGM group (adjusted difference, -0.4% [95% CI, -0.8% to -0.1%]; P = .02). In the CGM group, compared with the BGM group, the mean percentage of CGM-measured time in the target glucose range of 70 to 180 mg/dL was 59% vs 43% (adjusted difference, 15% [95% CI, 8% to 23%]; P < .001), the mean percentage of time at greater than 250 mg/dL was 11% vs 27% (adjusted difference, -16% [95% CI, -21% to -11%]; P < .001), and the means of the mean glucose values were 179 mg/dL vs 206 mg/dL (adjusted difference, -26 mg/dL [95% CI, -41 to -12]; P < .001). Severe hypoglycemic events occurred in 1 participant (1%) in the CGM group and in 1 (2%) in the BGM group. Conclusions and Relevance: Among adults with poorly controlled type 2 diabetes treated with basal insulin without prandial insulin, continuous glucose monitoring, as compared with blood glucose meter monitoring, resulted in significantly lower HbA1c levels at 8 months. Trial Registration: ClinicalTrials.gov Identifier: NCT03566693.


Asunto(s)
Glucemia/análisis , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Control Glucémico/métodos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Anciano , Intervalos de Confianza , Diabetes Mellitus Tipo 2/sangre , Femenino , Hemoglobina Glucada/análisis , Humanos , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Periodo Posprandial , Tamaño de la Muestra , Factores de Tiempo , Resultado del Tratamiento
15.
J Clin Exp Dent ; 13(4): e342-e349, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33841732

RESUMEN

BACKGROUND: Gingivitis is one of the most prevalent oral disease in humans. The most important etiological factor of gingivitis is dental plaque. Plaque control procedures comprises of several mechanical and chemical methods. Many studies have advocated that chemical plaque control methods can be used successfully as an adjunct to mechanical plaque control procedures. Thus, the aim of this pilot study is to evaluate the effectiveness of two topical antimicrobial gels as an adjunct to mechanical plaque control over a period of 2 weeks in treatment of chronic gingivitis patients. MATERIAL AND METHODS: This is a single blind, two arm parallel design pilot clinical study including 60 systemically healthy patients with 1) chronic generalized gingivitis (MGI>1), 2) probing depth ≤ 3mm and 3) zero clinical attachment loss. The study participants were randomly assigned into two groups i.e., Group I- Chlorhexidine Gluconate (CHX) gel, Group II- combination gel of Chlorhexidine gluconate and Metronidazole (CHX-MTZ) gel. Clinical parameters viz. Gingival Index (GI) and Modified Sulcus bleeding index (MSBI) were recorded firstly at baseline after Scaling and Root Planing(SRP), and secondly at the end of the study period of two weeks. Intra and inter-group comparisons of clinical parameters were done using appropriate statistical tests. RESULTS: There was high significant reduction in GI and MSBI scores at the end of 2 weeks period in both the groups. Further, combination gel of Group II (CHX+MTZ) was found to be statistically more effective as compared to Group I (CHX) used alone. CONCLUSIONS: Our study suggests that Chemotherapeutic agents like CHX and combination CHX-MTZ Gel are clinically effective as adjunct to Scaling and Root Planning(SRP) in treatment of Chronic Gingivitis. Further, post statistical comparative analysis has proved CHX-MTZ combination gel regime to be more clinically effective than CHX gel used alone in treatment of Chronic Gingivitis as adjunct to SRP. Key words:Scaling and Root Planning (SRP), Chronic Gingivitis, Chlorhexidine Gluconate (CHX) gel, Combination (CHX+MTZ) Gel, Metronidazole (MTZ).

16.
Adv Mater ; 32(49): e2004490, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33084168

RESUMEN

The small-polaron hopping model has been used for six decades to rationalize electronic charge transport in oxides. The model was developed for binary oxides, and, despite its significance, its accuracy has not been rigorously tested for higher-order oxides. Here, the small-polaron transport model is tested by using a spinel system with mixed cation oxidation states (Mnx Fe3- x O4 ). Using molecular-beam epitaxy (MBE), a series of single crystal Mnx Fe3- x O4 thin films with controlled stoichiometry, 0 ≤ x ≤ 2.3, and lattice strain are grown, and the cation site-occupation is determined through X-ray emission spectroscopy (XES). Density functional theory + U analysis shows that charge transport occurs only between like-cations (Fe/Fe or Mn/Mn). The site-occupation data and percolation models show that there are limited stoichiometric ranges for transport along Fe and Mn pathways. Furthermore, due to asymmetric hopping barriers and formation energies, the Mn O h 2 + polaron is energetically preferred to the Fe O h 2 + polaron, resulting in an asymmetric contribution of Mn/Mn pathways. All of these findings are not contained in the conventional small-polaron hopping model, highlighting its inadequacy. To correct the model, new parameters in the nearest-neighbor hopping equation are introduced to account for percolation, cross-hopping, and polaron-distribution, and it is found that a near-perfect correlation can be made between experiment and theory for the electronic conductivity.

17.
J Am Chem Soc ; 142(34): 14495-14503, 2020 08 26.
Artículo en Inglés | MEDLINE | ID: mdl-32786802

RESUMEN

Self-assembly of three-dimensional structures with order across multiple length scales-hierarchical assembly-is of great importance for biomolecules for the functions of life. Creation of similar complex architectures from inorganic building blocks has been pursued toward artificial biomaterials and advanced functional materials. Current research, however, primarily employs only large, nonreactive building blocks such as Au colloids. By contrast, sulfur-bridged transition metal clusters (<2 nm) are able to offer more functionality in catalytic and biochemical reactions. Hierarchical assembly of these systems has not been well researched because of the difficulty in obtaining single-phase clusters and the lack of suitable ligands to direct structure construction. To overcome these challenges, we employ a rigid planar ligand with an aromatic ring and bifunctional bond sites. We demonstrate the synthesis and assembly of 1.2 nm sulfur-bridged copper (SB-Cu) clusters with tertiary hierarchical complexity. The primary structure is clockwise/counterclockwise chiral cap and core molecules. They combine to form clusters, and due to the cap-core interaction (C-H···π), only two enantiomeric isomers are formed (secondary structure). A tertiary hierarchical architecture is achieved through the self-assembly of alternating enantiomers with hydrogen bonds as the intermolecular driving force. The SB-Cu clusters are air stable and have a distribution of oxidation states ranging from Cu(0) to Cu(I), making them interesting for redox and catalytic activities. This study shows that structural complexity at different length scales, mimicking biomolecules, can occur in active-metal clusters and provides a new platform for investigation of those systems and for the design of advanced functional materials.

18.
JAMA ; 323(23): 2397-2406, 2020 06 16.
Artículo en Inglés | MEDLINE | ID: mdl-32543682

RESUMEN

Importance: Continuous glucose monitoring (CGM) provides real-time assessment of glucose levels and may be beneficial in reducing hypoglycemia in older adults with type 1 diabetes. Objective: To determine whether CGM is effective in reducing hypoglycemia compared with standard blood glucose monitoring (BGM) in older adults with type 1 diabetes. Design, Setting, and Participants: Randomized clinical trial conducted at 22 endocrinology practices in the United States among 203 adults at least 60 years of age with type 1 diabetes. Interventions: Participants were randomly assigned in a 1:1 ratio to use CGM (n = 103) or standard BGM (n = 100). Main Outcomes and Measures: The primary outcome was CGM-measured percentage of time that sensor glucose values were less than 70 mg/dL during 6 months of follow-up. There were 31 prespecified secondary outcomes, including additional CGM metrics for hypoglycemia, hyperglycemia, and glucose control; hemoglobin A1c (HbA1c); and cognition and patient-reported outcomes, with adjustment for multiple comparisons to control for false-discovery rate. Results: Of the 203 participants (median age, 68 [interquartile range {IQR}, 65-71] years; median type 1 diabetes duration, 36 [IQR, 25-48] years; 52% female; 53% insulin pump use; mean HbA1c, 7.5% [SD, 0.9%]), 83% used CGM at least 6 days per week during month 6. Median time with glucose levels less than 70 mg/dL was 5.1% (73 minutes per day) at baseline and 2.7% (39 minutes per day) during follow-up in the CGM group vs 4.7% (68 minutes per day) and 4.9% (70 minutes per day), respectively, in the standard BGM group (adjusted treatment difference, -1.9% (-27 minutes per day); 95% CI, -2.8% to -1.1% [-40 to -16 minutes per day]; P <.001). Of the 31 prespecified secondary end points, there were statistically significant differences for all 9 CGM metrics, 6 of 7 HbA1c outcomes, and none of the 15 cognitive and patient-reported outcomes. Mean HbA1c decreased in the CGM group compared with the standard BGM group (adjusted group difference, -0.3%; 95% CI, -0.4% to -0.1%; P <.001). The most commonly reported adverse events using CGM and standard BGM, respectively, were severe hypoglycemia (1 and 10), fractures (5 and 1), falls (4 and 3), and emergency department visits (6 and 8). Conclusions and Relevance: Among adults aged 60 years or older with type 1 diabetes, continuous glucose monitoring compared with standard blood glucose monitoring resulted in a small but statistically significant improvement in hypoglycemia over 6 months. Further research is needed to understand the long-term clinical benefit. Trial Registration: ClinicalTrials.gov Identifier: NCT03240432.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/métodos , Glucemia/análisis , Diabetes Mellitus Tipo 1/sangre , Hemoglobina Glucada/análisis , Hipoglucemia/prevención & control , Anciano , Automonitorización de la Glucosa Sanguínea/instrumentación , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/psicología , Femenino , Humanos , Hiperglucemia/diagnóstico , Hipoglucemia/inducido químicamente , Hipoglucemia/diagnóstico , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/efectos adversos , Masculino , Persona de Mediana Edad , Monitoreo Ambulatorio/instrumentación , Medición de Resultados Informados por el Paciente
19.
Diabetes Technol Ther ; 22(9): 666-673, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-31833801

RESUMEN

Background: The aim was to assess the safety and tolerability of the insulin aspart biosimilar/follow-on product SAR341402 (100 U/mL solution; SAR-Asp) and originator insulin aspart (100 U/mL; NN-Asp; NovoLog®) self-administered through an insulin pump. Materials and Methods: This randomized, open-label, 2 × 4-week crossover study enrolled 45 adults with type 1 diabetes (T1D). Participants were randomized 1:1 to the treatment sequence SAR-Asp/NN-Asp or NN-Asp/SAR-Asp. The basal and prandial insulin doses were individually titrated. The primary outcome was the number of participants with at least one infusion set occlusion (infusion set change due to failure-to-correct hyperglycemia [plasma glucose ≥250 mg/dL] by insulin pump bolus) during the 4-week treatment. The main secondary outcome was the number of participants with at least one episode of unexplained hyperglycemia (regardless of correction by an insulin pump bolus without apparent material defect, medical, dietary, insulin dosing reason, or pump problem). Results: The number of participants reporting ≥1 infusion set occlusion were similar between treatments: 14/43 on SAR-Asp (33 events) and 12/43 on NN-Asp (24 events). The estimated difference in infusion set occlusion risk for SAR-Asp versus NN-Asp was 4.1% (95% confidence interval: -9.3% to 17.4%). The number of participants with ≥1 episode of unexplained hyperglycemia was similar between treatments (31/43 on SAR-Asp [154 events]; 32/43 on NN-Asp [175 events]). Hypoglycemia, treatment-emergent adverse events, hypersensitivity, and injection site reactions were similar between treatments. Conclusions: SAR-Asp and NN-Asp were well tolerated and had similar infusion set occlusions over a 4-week period in insulin pump users with T1D.


Asunto(s)
Biosimilares Farmacéuticos/uso terapéutico , Diabetes Mellitus Tipo 1 , Hipoglucemiantes/uso terapéutico , Insulina Aspart/uso terapéutico , Adulto , Anciano , Biosimilares Farmacéuticos/efectos adversos , Glucemia , Estudios Cruzados , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Femenino , Humanos , Hipoglucemiantes/efectos adversos , Insulina Aspart/efectos adversos , Sistemas de Infusión de Insulina , Masculino , Persona de Mediana Edad
20.
Diabetes Obes Metab ; 22(3): 434-441, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31865633

RESUMEN

AIM: To compare the safety and efficacy of U500-R delivered by a novel, specifically designed U500-R insulin pump with U-500R delivered by multiple daily injections (MDI). METHODS: The phase 3 VIVID study randomized people with type 2 diabetes to U-500R by continuous subcutaneous insulin infusion (CSII) or MDI. Participants (aged 18-85 years) had HbA1c ≥7.5% and ≤12.0% and a total daily dose of insulin >200 and ≤600 U/day. After a 2-week transition to three times daily injections of U-500R, participants were treated for 24 weeks with U-500R by CSII or MDI. Treatment arms were compared using mixed model repeated measures analysis. RESULTS: The study randomized 420 participants (CSII: 209, MDI: 211) with 365 completers. Mean changes from baseline were: HbA1c, -1.27% (-13.9 mmol/mol) with CSII and -0.85% (-9.3 mmol/mol) with MDI (difference - 0.42% [-4.6 mmol/mol], P <0.001); fasting plasma glucose, -33.9 mg/dL (-1.9 mmol/L) with CSII and 1.7 mg/dL (0.09 mmol/L) with MDI (difference - 35.6 mg/dL [-2.0 mmol/L], P <0.001); total daily dose, 2.8 U with CSII and 51.3 U with MDI (P < 0.001). Weight changes and rates of documented symptomatic and severe hypoglycaemia were similar between groups; the CSII group had a higher rate of nocturnal hypoglycaemia. CONCLUSIONS: In type 2 diabetes requiring high doses of insulin, both methods of U-500R delivery lowered HbA1c. However, the CSII group attained greater HbA1c reduction with significantly less insulin. Individualized dose titration will be important to balance glycaemic control with hypoglycaemia risk.


Asunto(s)
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Adulto , Glucemia , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Hemoglobina Glucada/análisis , Humanos , Hipoglucemiantes/efectos adversos , Inyecciones Subcutáneas , Insulina/uso terapéutico , Sistemas de Infusión de Insulina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...