Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
2.
Am J Cardiol ; 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38844197

RESUMEN

New-generation transcatheter-heart-valves (THV) have significantly improved technical success and procedural safety of transcatheter-aortic-valve-implantation (TAVI) procedures, but incidence of permanent pacemaker implantation (PPI) remains a concern.The study aimed to assess the role of anatomical annulus features in determining peri-procedural conduction disturbances leading to new-PPI following TAVI with the last generation Edwards Sapien balloon-expandable valves (BEV). In the context of a prospective single-center registry, we integrated clinical and procedural predictors of PPI with anatomical data derived from multi-slice-computed-tomography (MSCT). A total of 210 consecutive patients treated with balloon expandable Edwards THV were included in the study from 2015 to 2023. Technical success was achieved in 197 (93.8%) procedures, and 26 patients (12.4%) required new-PPI at 30-day follow-up (median time-to-implantation 3 days). At the univariable logistic-regression analysis, pre-procedural right bundle branch block (RBBB; OR:2.24 [95%CI:1.01-4.97], p=0.047), annulus eccentricity ≥0.25 (OR:5.43 [95%CI:2.21-13.36], p<0.001), calcium volume at annulus of the right coronary cusp (RCC) >48 mm3 (OR:2.60 [95%CI:1.13-5.96], p=0.024) and prosthesis implantation depth greater than membranous septum length (OR:2.17 [95%CI: 1.10-4.28], p=0.026) were associated with new-PPI risk. At multivariable analysis pre-procedural RBBB (OR:2.81 [95%CI:1.01-7.85], p=0.049), annulus eccentricity ≥0.25 (OR:4.14 [95%CI:1.85-9.27], p<0.001), and annulusRCC calcium >48 mm3 (OR:2.89 [95%CI:1.07-7.82], p=0.037) were confirmed as independent predictors of new-PPI. In conclusion, specific anatomical features of the aortic valve annulus might have an additive role in determining the occurrence of conduction disturbances in patients undergoing TAVI with BEV. This suggests the possibility to use the MSCT to improve the prediction of post-TAVI new-PPI risk.

3.
Int J Cardiol ; 410: 132218, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38815673

RESUMEN

BACKGROUND: The possibility to resheath some transcatheter heart valves (THV) facilitates the optimization of self-expandable devices implantation. However, resheating manoeuvres (expecially when repeated) increase the interaction between the transcatheter prosthesis and the patient's tissues potentially causing side-effects. AIMS: To assess the clinical outcomes of resheathing at midterm follow-up with a focus on the safety of multiple resheathing. METHODS: This retrospective observational study included all consecutive patients who underwent TAVI with a self-expandable supra-annular THV between December 2018 and December 2022. Primary endpoint was a composite of cardiovascular (CV) mortality, neurological events, non-fatal acute myocardial infarction and CV rehospitalizations. All clinical endpoints were assessed according to VARC-3 criteria. RESULTS: 469 TAVI procedures with self-expandable supra-annular THV were included in the study. The attempt to resheath and the resheath manoeuvres number was prospectively recorded into an electronic database. Resheating was attempted in 253 (53.9%) cases; 1, 2 and ≥ 3 resheathing were performed in respectively 122 (26.0%), 63 (13.4%) and 68 (14.5%) procedures. At a median follow-up of 640 days (interquartile range 340-1033 days), the incidence of the primary endpoint did not differ between 0 vs. ≥1 (22.7 vs. 26.1%, LogRank p = 0.584) and < 3 vs. ≥3 resheathing groups (24.2 vs. 26.5% LogRank p = 0.963). Furthermore, no significant differences in the primary endpoint were observed between 0, 1-2 and ≥ 3 resheathing (p = 0.84). CONCLUSIONS: Our study found that resheathing of self-expandable THVs during TAVI did not result in worse clinical outcomes compared with no resheathing at mid-term follow-up. These results are independent from the number of resheathing, underling the safety of multiple resheathing in terms of peri-procedural and mid-term outcome. CONDENSED ABSTRACT: In this retrospective observational study of 469 patients undergoing transcatheter aortic valve implantation (TAVI) for symptomatic severe aortic stenosis with self-expanding valves, we investigated the influence of resheathing on mid-term clinical outcomes. Specifically, we focused on the safety of multiple resheathing procedures. Our findings revealed no significant impact of resheathing on medium-term outcomes. The primary endpoint, a composite of cardiovascular mortality, neurological events, non-fatal acute myocardial infarction, and cardiovascular rehospitalizations, did not show statistically significant differences between no resheathing, single resheathing and multiple resheathing groups. Our study suggests that resheathing, even when performed multiple times, does not appear to significantly affect clinical outcomes at mid-term follow-up.

4.
Catheter Cardiovasc Interv ; 103(3): 443-454, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38173287

RESUMEN

The introduction of transradial access for percutaneous coronary diagnostic and interventional procedures has led to a decrease in access site complications. The aim of this paper is to propose a combined stepwise technical approach where real time ultrasound ("echo-first" approach) can be used to select the best vascular access and, together with angiography, to manage the potential obstacles that may occur during transradial procedures. In each section, we summarize some tips and tricks based on both our experience and current literature that can be easily implemented in daily practice to increase the success of transradial procedures.


Asunto(s)
Intervención Coronaria Percutánea , Arteria Radial , Humanos , Arteria Radial/diagnóstico por imagen , Angiografía Coronaria/efectos adversos , Angiografía Coronaria/métodos , Resultado del Tratamiento , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos
5.
Minerva Cardiol Angiol ; 72(2): 172-181, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38088090

RESUMEN

BACKGROUND: Paravalvular leakage (PVL) is a common finding after transcatheter aortic valve replacement (TAVR) and affects late clinical outcome. It is more frequent with self-expandable (SE) transcatheter-heart-valve (THV). Few is known about SE-THV expansion after implantation. The purpose is to assess SE-THV frame expansion and its possible influence on PVL. METHODS: We designed a prospective pilot study to assess the time-course of SE-THV frame dimensions and PVL after TAVR. Consecutive patients undergoing TAVR with SE-THV were enrolled. Prosthesis fluoroscopy and echocardiography were prospectively performed immediately after TAVR (T0) and before discharge (T1) to grade PVL. Prosthesis diameters were assessed in 2 fluoroscopic orthogonal views. PVL reduction ≥1+ from T0 to T1 at echocardiography was the primary study endpoint. RESULTS: Twenty-five patients were enrolled. Mean interval between T0 and T1 evaluations was 5 days. Grade 1 or 2 was present in 76% of patients at T0 and in 68% at T1 (P=0.034). A total of 7 patients (28%) improved PVL ≥1 grade from T0 to T1. Differences between T0 and T1 fluoroscopic diameters were not statistically significant. When comparing the diameter changes according to PVL evolution, patients with PVL improvement (as compared with those without) had significantly larger minimum diameter increase at both annulus/inflow (P=0.016) and outflow/distal edge (P=0.027). CONCLUSIONS: PVL may improve in the early days after SE-THV and those patients with PVL improvement may have THV frame expansion. Further studies are needed to confirm such preliminary observations and to establish the clinical relevance of this phenomenon.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estudios Prospectivos , Proyectos Piloto , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Diseño de Prótesis
9.
Biosystems ; 230: 104936, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37279825

RESUMEN

In the seminal work on autopoiesis by Varela, Maturana, and Uribe, they start by addressing the confusion between processes that are history dependent and processes that are history independent in the biological world. The former is particularly linked to evolution and ontogenesis, while the latter pertains to the organizational features of biological individuals. Varela, Maturana, and Uribe reject this framework and propose their original theory of autopoietic organization, which emphasizes the strong complementarity of temporal and non-temporal phenomena. They argue that the dichotomy between structure and organization lies at the core of the unity of living systems. By opposing history-dependent and history-independent processes, methodological challenges arise in explaining phenomena related to living systems and cognition. Consequently, Maturana and Varela reject this approach in defining autopoietic organization. I argue, however, that this relationship presents an issue that can be found in recent developments of the science of artificial intelligence (AI) in different ways, giving rise to related concerns. While highly capable AI systems exist that can perform cognitive tasks, their internal workings and the specific contributions of their components to the overall system behavior, understood as a unified whole, remain largely uninterpretable. This article explores the connection between biological systems, cognition, and recent developments in AI systems that could potentially be linked to autopoiesis and related concepts such as autonomy and organization. The aim is to assess the advantages and disadvantages of employing autopoiesis in the synthetic (artificial) explanation for biological cognitive systems and to determine if and how the notion of autopoiesis can still be fruitful in this perspective.


Asunto(s)
Inteligencia Artificial , Cognición , Humanos
10.
Int J Cardiol ; 387: 131098, 2023 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-37290663

RESUMEN

BACKGROUND: The use of Impella support is increasingly adopted to "protect" patients with severe coronary artery disease (CAD) and left ventricle (LV) dysfunction undergoing percutaneous coronary intervention (PCI). AIMS: To evaluate the impact of Impella-protected (Abiomed, Danvers, Massachusetts, USA) PCIs on myocardial function recovery. METHODS: Patients with significant LV dysfunction undergoing multi-vessel PCIs with pre-intervention Impella implantation were evaluated by echocardiography before PCI and at median follow up of 6 months: global and segmental LV contractile function were assessed by LV ejection fraction (LVEF) and wall motion score index (WMSI), respectively. Extent of revascularization was graded using the British Cardiovascular Intervention Society Jeopardy score (BCIS-JS). Study endpoints were LVEF and WMSI improvement, and its correlation with revascularization. RESULTS: A total of 48 high surgical risk (mean EuroSCORE II 8) patients with median LVEF value of 30%, extensive wall motion abnormalities (median WMSI 2.16), and severe multi-vessel CAD (mean SYNTAX score 35) were included. PCIs brought a significant reduction of ischemic myocardium burden with BCIS-JS decrease from mean value of 12 to 4 (p < 0.001). At follow-up, WMSI reduced from 2.2 to 2.0 (p = 0.004) and LVEF increased from 30% to 35% (p = 0.016). WMSI improvement was proportional to the baseline impairment (R - 0.50, p < 0.001), and confined to revascularized segments (from 2.1 to 1.9, p < 0.001). CONCLUSIONS: In patients with extensive CAD and severe LV dysfunction, multi-vessel Impella-protected PCI was associated to an appreciable contractile recovery, mainly determined by regional wall motion improvement in revascularized segments.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Disfunción Ventricular Izquierda , Humanos , Función Ventricular Izquierda , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Ventrículos Cardíacos , Recuperación de la Función , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/terapia
11.
EuroIntervention ; 19(5): e423-e431, 2023 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-37171514

RESUMEN

BACKGROUND: In patients with complex coronary bifurcation lesions undergoing percutaneous coronary intervention (PCI), various 2-stent techniques might be utilised. The Visible Heart Laboratories (VHL) offer an experimental environment where PCI results can be assessed by multimodality imaging. AIMS: We aimed to assess the post-PCI stent configuration achieved by 2-stent techniques in the VHL and to evaluate the procedural factors associated with suboptimal results. METHODS: Bifurcation PCI with 2-stent techniques, performed by expert operators in the VHL on explanted beating swine hearts, was studied. The adopted bifurcation PCI strategy and the specific procedural steps applied in each procedure were classified according to Main, Across, Distal, Side (MADS)-2 and to their adherence to the European Bifurcation Club (EBC) recommendations. Microcomputed tomography (micro-CT) was used to assess the post-PCI stent configuration. The primary endpoint was "suboptimal stent implantation", defined as a composite of stent underexpansion (<90%), side branch ostial area stenosis >50% and the gap between stents. RESULTS: A total of 82 PCI with bifurcation stenting were assessed, comprised of 29 crush, 25 culotte, 28 T/T and small protrusion (TAP) techniques. Suboptimal stent implantation was observed in as many as 53.7% of the cases, regardless of baseline anatomy or the stenting strategy. However, less frequent use of the proximal optimisation technique (POT; p=0.015) and kissing balloon inflations (KBI; p=0.027) and no adherence to EBC recommendations (p=0.004, p multivariate=0.006) were significantly associated with the primary endpoint. CONCLUSIONS: Commonly practised bifurcation 2-stent techniques may result in imperfect stent configurations. More frequent use of POT/KBI and adherence to expert recommendations might reduce the occurrence of post-PCI suboptimal stent configurations.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Animales , Porcinos , Intervención Coronaria Percutánea/métodos , Microtomografía por Rayos X , Resultado del Tratamiento , Stents , Constricción Patológica , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/cirugía
13.
Circ Cardiovasc Interv ; 16(3): e012908, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36943931

RESUMEN

BACKGROUND: Stepwise provisional stenting is the gold standard for percutaneous coronary intervention (PCI) on bifurcation lesions, but the optimal ballooning technique for eventual side branch treatment is not established. The objective of the present study was to compare the stent configuration obtained by 2 different side branch optimization techniques performed after main vessel (MV) stent implantation: proximal optimization technique+kissing balloon inflation+final proximal optimization technique (POT/KBI/POT [PKP]) versus proximal optimization technique+isolated side branch dilation+final proximal optimization technique (POT-side-POT [PSP]). METHODS: We realized a 1:1 prospective randomized trial comparing bifurcation PCI conducted (under angiographic and angioscopic visualization) with either PKP or PSP in reanimated swine hearts using commercially available drug-eluting stents. After PCI, the obtained stent configuration (expansion, eccentricity, apposition) was assessed by optical coherence tomography and micro-computed tomography dividing the stent in 4 segments. Primary study end point was minimum stent expansion at the distal MV segment. RESULTS: A total of 30 PCIs were successfully performed according to randomization obtaining overall good results (average minimum stent expansion >90% at optical coherence tomography and micro-computed tomography) with PSP or PKP. Minimum stent expansion at the distal MV segment was significantly higher with PKP as compared with PSP at optical coherence tomography (97.9±4.2% versus 91.0±7.7%; P=0.002) and micro-computed tomography (98.1±4.1% versus 91.3±7.9%; P=0.006). Other significant findings included higher stent eccentricity index at proximal MV with PSP, higher side branch scaffolding length and lower malapposition (at bifurcation core and distal MV) with PKP. CONCLUSIONS: This first prospective randomized trial in a unique non-atherosclerotic preclinical environment showed that bifurcation PCI conducted with PSP and PKP achieves different stent configurations. These findings might be useful in bifurcation PCI practice and call for further evaluations in clinical ground.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Animales , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Estudios Prospectivos , Stents , Porcinos , Resultado del Tratamiento , Microtomografía por Rayos X
14.
Rev. esp. cardiol. (Ed. impr.) ; 76(3): 157-164, mar, 2023. ilus, tab, graf
Artículo en Español | IBECS | ID: ibc-216565

RESUMEN

Introducción y objetivos La enfermedad coronaria (EC) se encuentra en el 30-50% de los pacientes con estenosis aórtica (EA) grave que reciben tratamiento intervencionista. Todavía no está claro cuál es el mejor tratamiento de la EAC en pacientes con EA sometidos a implante percutáneo de válvula aórtica (TAVI). El objetivo del estudio fue analizar el impacto clínico del miocardio en riesgo en pacientes con EAC y EA grave tratados con TAVI. Métodos Se incluyó a pacientes consecutivos sometidos a TAVI en nuestro hospital. En presencia de EAC, el miocardio en riesgo antes del procedimiento se clasificó utilizando la puntuación de riesgo (JS) de la British Cardiovascular Intervention Society (BCIS). La población de estudio se dividió en 3 grupos: pacientes sin EAC concomitante (grupo No-EAC), pacientes con EAC y BCIS-JS ≤ 4 (grupo EAC BCIS-JS ≤ 4) y pacientes con EAC concomitante y BCIS-JS> 4 (grupo EAD BCIS -JS> 4). El objetivo primario del estudio fueron los eventos cardiovasculares y cerebrovasculares adversos mayores (MACCE). Resultados Se incluyó a un total de 403 pacientes: 223 No-EAD, 94 EAC BCIS-JS ≤ 4 y 86 EAC BCIS-JS> 4. Con 3 meses de seguimiento [rango 104 – 3.296 días], los pacientes sin EAC y los pacientes con EAC con BCIS-JS ≤ 4 tuvieron una mejor supervivencia libre de MACCE en comparación con aquellos con revascularización menos extensa (BCIS-JS> 4) (p=0,049). Este resultado se debió en parte a una reducción significativa de la mortalidad (p=0,031). En el análisis multivariado, el BCIS-JS residual ≤ 4 y la clase III-IV de la NYHA predijeron MACCE de forma independiente. Conclusiones En pacientes con EAC y EA grave, la extensión del miocardio en riesgo antes del TAVI influye en los resultados clínicos (AU)


Introduction and objectives Coronary artery disease (CAD) is found in 30%-50% of patients with severe aortic stenosis (AS) undergoing treatment. The best management of CAD in AS patients undergoing transcatheter aortic valve implantation (TAVI) is still unclear. We investigated the clinical impact of the extent of jeopardized myocardium in patients with concomitant CAD and severe AS treated by TAVI. Methods Consecutive patients who underwent TAVI procedures at our hospital were identified. In the presence of CAD, the myocardium jeopardized before TAVI was graded using the British Cardiovascular Intervention Society (BCIS) jeopardy score (JS). The study population was divided in 3 groups: patients without concomitant CAD (no-CAD), patients with CAD and BCIS-JS ≤ 4 (CAD BCIS-JS ≤ 4) and patients with concomitant CAD and BCIS-JS> 4 (CAD BCIS-JS> 4). The primary study endpoint was major adverse cardiovascular and cerebrovascular events (MACCE). Results A total of 403 patients entered the study: 223 no-CAD, 94 CAD BCIS-JS ≤ 4 and 86 CAD BCIS-JS> 4. At> 3 months of follow-up [range 104–3296 days], patients without CAD and CAD patients with BCIS-JS ≤ 4 had better survival free from MACCE compared with those with less extensive revascularization (BCIS-JS> 4) (P=.049). This result was driven by a significant reduction in death (P=.031). On multivariate analysis, residual BCIS-JS ≤ 4 and NYHA class III-IV independently predicted MACCE. Conclusions In patients with concomitant CAD and severe AS, the extent of jeopardized myocardium before TAVI impacts on clinical outcomes (AU)


Asunto(s)
Humanos , Masculino , Femenino , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Estudios Retrospectivos , Estudios de Seguimiento , Factores de Riesgo
15.
Minerva Cardiol Angiol ; 71(1): 20-26, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33703859

RESUMEN

BACKGROUND: In provisional technique, main vessel (MV) drug-eluting stent (DES) diameter is usually selected according to distal MV to reduce carina shift. Proximal optimization technique (POT) is used to expand the DES in the proximal MV. Occasionally, the size discrepancy between left main (LM) and left anterior descending artery (LAD) may be huge and this may cause stent malapposition and poor vessel wall coverage in large-sized LM. Recently, some manufactures designed extra-large DES to treat large vessels. METHODS: We developed an "adapted" provisional strategy based on under-deployment of extra-large DES in case of major size mismatch between LM and proximal LAD. Bench tests were realized in appropriately designed LM bifurcation model using an extra-large DES (Onyx XL, Medtronic, Santa Rosa, CA, USA). This technique was adopted when such "rare" anatomy was found in our clinical practice. RESULTS: At bench test, Onyx XL 4.5 mm stent reaches 3.8 mm at 5-6 atmospheres, with favorable stent deformation achieved after POT, kissing balloon and re-POT. This technique was performed in 10 patients undergoing unprotected LM stenting with large LM and major mismatch toward LAD. Angiographic success was achieved in all cases and optical coherence tomography assessment was performed in 5 patients revealing optimal stent result. After a follow-up of 557 days (range: 90-1369 days), clinical course was uneventful in all treated patients. CONCLUSIONS: Under-deployment of extra-large DES is a technical option that can be considered to optimize the provisional stenting technique in selected patients with major diameter mismatch between large-sized LM and LAD.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Angioplastia Coronaria con Balón/métodos , Angiografía Coronaria/métodos , Resultado del Tratamiento
16.
Rev Esp Cardiol (Engl Ed) ; 76(3): 157-164, 2023 Mar.
Artículo en Inglés, Español | MEDLINE | ID: mdl-35691553

RESUMEN

INTRODUCTION AND OBJECTIVES: Coronary artery disease (CAD) is found in 30%-50% of patients with severe aortic stenosis (AS) undergoing treatment. The best management of CAD in AS patients undergoing transcatheter aortic valve implantation (TAVI) is still unclear. We investigated the clinical impact of the extent of jeopardized myocardium in patients with concomitant CAD and severe AS treated by TAVI. METHODS: Consecutive patients who underwent TAVI procedures at our hospital were identified. In the presence of CAD, the myocardium jeopardized before TAVI was graded using the British Cardiovascular Intervention Society (BCIS) jeopardy score (JS). The study population was divided in 3 groups: patients without concomitant CAD (no-CAD), patients with CAD and BCIS-JS ≤ 4 (CAD BCIS-JS ≤ 4) and patients with concomitant CAD and BCIS-JS> 4 (CAD BCIS-JS> 4). The primary study endpoint was major adverse cardiovascular and cerebrovascular events (MACCE). RESULTS: A total of 403 patients entered the study: 223 no-CAD, 94 CAD BCIS-JS ≤ 4 and 86 CAD BCIS-JS> 4. At> 3 months of follow-up [range 104-3296 days], patients without CAD and CAD patients with BCIS-JS ≤ 4 had better survival free from MACCE compared with those with less extensive revascularization (BCIS-JS> 4) (P=.049). This result was driven by a significant reduction in death (P=.031). On multivariate analysis, residual BCIS-JS ≤ 4 and NYHA class III-IV independently predicted MACCE. CONCLUSIONS: In patients with concomitant CAD and severe AS, the extent of jeopardized myocardium before TAVI impacts on clinical outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica , Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Arteria Coronaria/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Miocardio , Resultado del Tratamiento , Intervención Coronaria Percutánea/métodos , Factores de Riesgo
17.
J Cardiovasc Dev Dis ; 9(12)2022 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-36547410

RESUMEN

Transcatheter aortic valve replacement (TAVR) has become a popular treatment option for severe aortic stenosis for patients with a high risk for mortality with surgical aortic valve replacement (SAVR). Coronary artery occlusion (CAO) following the implantation of the device is a potential and sometimes devastating complication of this procedure, that provokes a sudden deterioration of hemodynamic status followed by cardiogenic shock and electrical instability. With patients that present a high risk for coronary obstruction, coronary protection with a chimney stenting technique is an effective strategy that can ensure coronary perfusion during TAVR in case of acute CAO. Utilizing Visible Heart® methodologies, a human heart was reanimated. A chimney stenting technique was implemented simultaneously with the deployment of a Medtronic Evolut™ Pro+ valve (Medtronic PLC; Minneapolis, MN, USA). The entire procedure was recorded utilizing endoscopic cameras, fluoroscopy, optical coherence tomography, and echocardiography. In addition to these procedural visualizations, post-procedural micro-computed tomography (micro-CT) was conducted to provide post-implantation imaging with approximately 60-micron resolution. Utilizing these imaging modalities in a reanimated human heart allows for the unique opportunity to collect data for TAVR procedures in real human anatomies for the subsequent educational uses by the physicians treating aortic valvular disease and/or the designers of future TAVR technologies and procedures.

19.
Front Cardiovasc Med ; 9: 895477, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35711347

RESUMEN

Actually transcatheter aortic valve implantation within failed surgically bioprosthetic valves (VIV-TAVI) is an established procedure in patients at high risk for repeat surgical aortic valve intervention. Although less invasive than surgical reintervention, VIV-TAVI procedure offers potential challenges, such as higher rates of prosthesis-patient mismatch and coronary obstruction. Thus, optimal procedural planning plays an important role to minimize the risk of procedure complications. In this review, we describe the key points of a VIV-TAVI procedure to optimize outcomes and reduce the risk of procedure complications.

20.
Biosystems ; 148: 32-39, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26802674

RESUMEN

Artificial intelligence can make numerous contributions to synthetic biology. I would like to suggest three that are related to the past, present and future of artificial intelligence. From the past, works in biology and artificial systems by Turing and von Neumann prove highly interesting to explore within the new framework of synthetic biology, especially with regard to the notions of self-modification and self-replication and their links to emergence and the bottom-up approach. The current epistemological inquiry into emergence and research on swarm intelligence, superorganisms and biologically inspired cognitive architecture may lead to new achievements on the possibilities of synthetic biology in explaining cognitive processes. Finally, the present-day discussion on the future of artificial intelligence and the rise of superintelligence may point to some research trends for the future of synthetic biology and help to better define the boundary of notions such as "life", "cognition", "artificial" and "natural", as well as their interconnections in theoretical synthetic biology.


Asunto(s)
Inteligencia Artificial , Cognición/fisiología , Biología Computacional/métodos , Biología Sintética/métodos , Comunicación , Biología Computacional/tendencias , Predicción , Humanos , Inteligencia/fisiología , Apoyo Social , Biología Sintética/tendencias
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...