Australas J Ultrasound Med ; 26(3): 142-149, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37701771

RESUMEN

Introduction/Purpose: Ultrasound-guided popliteal fossa sciatic nerve (PFSN) blocks are performed with patients in the supine, lateral or prone position. No known studies compare the quality of images obtained from each approach. This study examines the quality of supine and prone PFSN ultrasound images. Methods: Thirty-eight adult volunteers were sorted into two groups. Five regional anaesthesiologists performed ultrasound examinations of the PFSN on volunteers in supine and prone positions. Popliteal fossa sciatic nerve image quality was analysed with grayscale techniques and peer evaluation. Popliteal fossa sciatic nerve depth, distance from the popliteal crease and time until optimal imaging were recorded. Results: The grayscale ratio of the PFSN vs. the background was 1.83 (supine) and 1.75 (prone) (P = 0.034). Similarly, the grayscale ratio of the PFSN vs. the immediately adjacent area was 1.65 (supine) and 1.55 (prone) (P = 0.004). Mean depth of the PFSN was 1.6 cm (supine) and 1.7 cm (prone) (P = 0.009). Average distance from the popliteal crease to the PFSN was 5.9 cm (supine) and 6.6 cm (prone) (P = 0.02). Mean time to acquire optimal imaging was 36 s (supine) and 47 s (prone) (P = 0.002). Observers preferred supine positioning 53.8%, prone positioning 22.5% and no preference 23.7% of the time. Observers with strong preferences preferred supine imaging in 70.9% of cases. Conclusions: Supine ultrasound examination offered quicker identification of the PFSN, in a more superficial location, closer to the popliteal crease and with enhanced contrast to surrounding tissue, correlating with observer preferences for supine positioning. These results may influence ultrasound-guided PFSN block success rates, especially in difficult-to-image patients.

3.
Anesth Analg ; 132(3): 743-751, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-32398433

RESUMEN

BACKGROUND: Over 6 million esophagogastroduodenoscopy (EGD) procedures are performed in the United States each year. Patients having anesthesia for advanced EGD procedures, such as interventional procedures, are at high risk for hypoxemia. METHODS: Our primary study aim was to evaluate whether high-flow nasal cannula (HFNC) oxygen reduces the incidence of hypoxemia during anesthesia for advanced EGD. Secondarily, we studied whether HFNC oxygen reduces hypercarbia or hypotension. After obtaining written informed consent, adults having anesthesia for advanced EGD, expected to last longer than 15 minutes, were randomly assigned to receive HFNC oxygen or standard nasal cannula (SNC) oxygen. The primary outcome was occurrence of one or more hypoxemia events during anesthesia, defined by arterial oxygen saturation <92% for at least 15 consecutive seconds. Secondary outcomes were occurrence of one or more hypercarbia or hypotension events. A hypercarbia event was defined by a transcutaneous CO2 measurement 20 mm Hg or more above baseline, and a hypotension event was defined by a mean arterial blood pressure measurement 25% or more below baseline. RESULTS: Two hundred seventy-one adult patients were enrolled and randomized, and 262 patients completed study procedures. Eight randomized patients did not complete study procedures due to changes in their anesthesia or endoscopy plan. One patient was excluded from analysis because their procedure was aborted after 1 minute. Patients who received HFNC oxygen (N = 132) had a significantly lower incidence of hypoxemia than those who received SNC oxygen (N = 130; 21.2% vs 33.1%; hazard ratio [HR] = 0.59 [95% confidence interval {CI}, 0.36-0.95]; P = .03). There was no difference in the incidence of hypercarbia or hypotension between the groups. The HR for hypercarbia with HFNC oxygen was 1.29 (95% CI, 0.89-1.88; P = .17), and the HR for hypotension was 1.25 (95% CI, 0.86-1.82; P = .25). CONCLUSIONS: HFNC oxygen reduces the incidence of hypoxemia during anesthesia for advanced EGD and may offer an opportunity to enhance patient safety during these procedures.


Asunto(s)
Anestesia Intravenosa , Cánula , Endoscopía del Sistema Digestivo , Hipoxia/prevención & control , Terapia por Inhalación de Oxígeno/instrumentación , Oxígeno/administración & dosificación , Administración por Inhalación , Anciano , Anestesia Intravenosa/efectos adversos , Baltimore , Femenino , Humanos , Hipoxia/sangre , Hipoxia/etiología , Masculino , Persona de Mediana Edad , Oxígeno/efectos adversos , Oxígeno/sangre , Terapia por Inhalación de Oxígeno/efectos adversos , Factores Protectores , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
4.
Anesthesiology ; 130(6): 1007-1016, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30844948

RESUMEN

BACKGROUND: There is confusion regarding the spread of intraneurally injected local anesthetic agents during regional anesthesia. The aim of this research was to deliberately inject a marker that does not leave the neural compartment into which it is injected, and then to study the longitudinal and circumferential spread and possible pathways of intraneural spread. METHODS: After institutional review board approval, we intraneurally injected 20 and 5 ml of heparinized blood solution under ultrasound guidance into 12 sciatic nerves in the popliteal fossa and 10 median nerves, respectively, of eight fresh, unembalmed cadavers using standard 22-gauge "D" needles, mimicking the blocks in clinical conditions. Ultrasound evidence of nerve swelling confirmed intraneural injection. Samples of the nerves were then examined under light and scanning electron microscopy. RESULTS: Extrafascicular spread was observed in all the adipocyte-containing neural compartments of the 664 cross-section samples we examined, but intrafascicular spread was seen in only 6 cross-sections of two nerves. None of the epineurium, perineurium, or neural components were disrupted in any of the samples. Spread between the layers of the perineurium was a route of spread that included the perineurium surrounding the fascicles and the perineurium that formed incomplete septa in the fascicles. Similar to the endoneurium proper, subepineural compartments that did not contain any fat cells did not reveal any spread of heparinized blood solution cells. No "perineural" spaces were observed within the endoneurium. We also did not observe any true intrafascicular spread. CONCLUSIONS: After deliberate intraneural injection, longitudinal and circumferential extrafascicular spread occurred in all instances in the neural compartments that contained adipocytes, but not in the relatively solid endoneurium of the fascicles.


Asunto(s)
Anestésicos Locales/administración & dosificación , Anestésicos Locales/metabolismo , Bloqueo Nervioso/métodos , Nervios Periféricos/diagnóstico por imagen , Nervios Periféricos/metabolismo , Ultrasonografía Intervencional/métodos , Cadáver , Humanos , Inyecciones , Nervios Periféricos/efectos de los fármacos , Nervio Ciático/diagnóstico por imagen , Nervio Ciático/efectos de los fármacos , Nervio Ciático/metabolismo
5.
Clin Anat ; 31(7): 1050-1057, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30113091

RESUMEN

Recent anatomical discoveries indicate the importance of identifying membranes and compartments surrounding peripheral nerves into which local anesthetic agents can be injected and continuous nerve block catheters placed during regional anesthetic procedures. However, current markers used in anatomical studies have multiple drawbacks, specifically extravasation into noninjected locations, which can result in inadequate treatment. We studied a readily-available new marker, heparinized blood solution (HBS), which is easy to identify by microscopy and can remain in the nerve compartment into which it is deposited without distorting the tissue. We collected blood from 22 patients and prepared it as HBS. This was then injected into four fresh cadavers as in routine clinical practice for ultrasound-guided nerve blocks to form a so-called "doughnut" by "hydro-dissecting" at 32 sites. All samples, including nerves and neighboring tissues, were then prepared and examined by light microscopy. Although no deliberate intraneural injection was attempted, the marker was identified inside all the nerve compartments except the fascicles. Apart from leaking through the needle entry site in some instances, there was no extravasation of the HBS into neighboring nerve compartments in either direction. The tissues were not distorted and the erythrocytes did not form a thrombus. Nerve membranes and compartments could be clearly identified with routine staining. This technique enabled us to study the longitudinal and circumferential spread in all nerve compartments and to collect data for better interpretation of factors influencing an anesthetic nerve block and situations in which complications could possibly arise. HBS seemed superior to other markers because it did not leave the compartments into which it had been injected, did not distort the tissue, and was easily visible under the light microscope. Clin. Anat., 31:1050-1057, 2018. © 2018 Wiley Periodicals, Inc.


Asunto(s)
Medios de Contraste/administración & dosificación , Heparina/administración & dosificación , Bloqueo Nervioso/métodos , Nervios Periféricos/ultraestructura , Biomarcadores/sangre , Cadáver , Humanos , Traumatismos de los Nervios Periféricos/prevención & control , Nervios Periféricos/anatomía & histología
6.
A A Case Rep ; 8(10): 272-275, 2017 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-28328582

RESUMEN

Needle guides may allow the practitioner to align the needle with the probe when ultrasound-guided nerve block is performed. The author's goal was to design and fabricate an inexpensive ($1.90), disposable, needle guide that could articulate over a range from 85 degrees to 0 degrees with a three-dimension printer. Three-dimensional representations of an L50, L25, and C 60 ultrasound probe (Sono Site, Bothell, WA) were created using a laser scanner. Computer-aided design software (Solid Works, Waltham, MA) was used to design a needle bracket and needle guide to attach to these probes. A three-dimensional printer was used to fabricate the needle bracket and guide with acrylonitrile polybutadiene polystyrene. An echogenic needle was held in plane with the needle guide. The author performed a supraclavicular block in a morbidly obese patient. The needle was easily visualized. Similar guides that are commercially available cost as much as $400. A knowledge of computer-aided design is necessary for this work.


Asunto(s)
Diseño Asistido por Computadora , Equipos Desechables , Agujas , Bloqueo Nervioso/instrumentación , Obesidad Mórbida/complicaciones , Impresión Tridimensional , Transductores , Ultrasonografía Intervencional/instrumentación , Acrilonitrilo/química , Butadienos/química , Elastómeros/química , Diseño de Equipo , Humanos , Persona de Mediana Edad , Bloqueo Nervioso/métodos , Poliestirenos/química , Estereolitografía
8.
Reg Anesth Pain Med ; 42(1): 126, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-27997496
9.
J Ultrasound Med ; 35(6): 1319-23, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27162281

RESUMEN

We have designed, produced, and tested an echogenic needle based on a sawtooth pattern where the height of the tooth was 1.25 times the wavelength of the ultrasound transducer. A numeric solution to the time-independent wave equation (Helmholtz equation) was used to create a model of backscattering from a needle. A 21-gauge stainless steel prototype was manufactured and tested in a water bath. Backscattering from the needle was compared to theoretical predications from our model. Based on these results, an 18-gauge prototype needle was fabricated from stainless steel and tested in a pig cadaver. This needle was compared to a commercial 18-gauge echogenic needle (Pajunk Medical Systems, Tucker, GA) by measuring the brightness of the needle relative to the background of sonograms of a needle in a pig cadaver. The backscattering from the 21-gauge prototype needle reproduced the qualitative predictions of our model. At 30° and 45° of insonation, our prototype performed equivalently to the Pajunk needle. At 60°, our prototype was significantly brighter than the Pajunk needle (P = .017). In conclusion, we chose a model for the design of an echogenic needle and modeled it on the basis of a solution to the Helmholtz equation. A prototype needle was tested in a water bath and compared to the model prediction. After verification of our model, we designed an 18-gauge needle, which performed better than an existing echogenic needle (Pajunk) at 60° of insonation. Our needle will require further testing in human trials.


Asunto(s)
Bloqueo Nervioso/instrumentación , Ultrasonografía Intervencional/métodos , Animales , Diseño de Equipo , Modelos Biológicos , Agujas , Porcinos
10.
Anesthesiology ; 123(2): 459-74, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26083767

RESUMEN

Given the fast development and increasing clinical relevance of ultrasound guidance for thoracic paravertebral blockade, this review article strives (1) to provide comprehensive information on thoracic paravertebral space anatomy, tailored to the needs of a regional anesthesia practitioner, (2) to interpret ultrasound images of the thoracic paravertebral space using cross-sectional anatomical images that are matched in location and plane, and (3) to briefly describe and discuss different ultrasound-guided approaches to thoracic paravertebral blockade. To illustrate the pertinent anatomy, high-resolution photographs of anatomical cross-sections are used. By using voxel anatomy, it is possible to visualize the needle pathway of different approaches in the same human specimen. This offers a unique presentation of this complex anatomical region and is inherently more realistic than anatomical drawings.


Asunto(s)
Bloqueo Nervioso/métodos , Vértebras Torácicas/diagnóstico por imagen , Ultrasonografía Intervencional/métodos , Humanos
11.
Curr Opin Anaesthesiol ; 28(1): 89-94, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25500688

RESUMEN

PURPOSE OF REVIEW: Open cardiac surgery may cause severe postoperative pain and the activation of a perioperative stress response. If not treated adequately, the patient may suffer increased morbidity, a longer hospital stay, and higher overall costs. This article reviews the literature regarding various modalities for management of postoperative pain after cardiac surgery. RECENT FINDINGS: Paravertebral block of the spinal nerve roots provides similar analgesia to thoracic epidural without the risk of hypotension or epidural hematoma. Continuous α-2 agonist infusion reduces opioid requirements in the immediate postoperative period and may convey a morbidity and mortality benefit in cardiac surgery patients that persists for 12 months. Antiepileptics may significantly decrease opioid requirements and improve pain scores. Finally, complementary and alternative practices such as acupuncture, music, and behavioral exercises both pre and postoperatively may improve acute pain and lessen conversion to chronic pain. SUMMARY: Although published data remain limited, recent evidence indicates that patients may benefit from the addition of a variety of novel pain-management strategies currently under investigation. Selection of a multimodal approach to perioperative pain management is advocated, including selective application of regional analgesia, non-narcotic medications, and complimentary alternative options to improve patient comfort and overall outcome.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Manejo del Dolor/métodos , Dolor Postoperatorio/tratamiento farmacológico , Atención Perioperativa/métodos , Analgesia/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Humanos
12.
Case Rep Anesthesiol ; 2014: 349797, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24715987

RESUMEN

Ultrasound guidance is recommended for cannulation of the internal jugular vein. Use of ultrasound allows you to identify relevant anatomy and possible anatomical anomalies. The most common approach is performed while visualizing the vein transversely and inserting the needle out of plane to the probe. With this approach needle tip visualization may be difficult. We report the use of a new biplane ultrasound probe which allows the user to simultaneously view the internal jugular vein in transverse and longitudinal views in real time. Use of this probe enhances needle visualization during venous cannulation.

14.
A A Case Rep ; 2(8): 96-8, 2014 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-25611769

RESUMEN

A 25-year-old man presented for revision of a dialysis fistula in his left upper arm. An ultrasound-guided left supraclavicular block was performed, and 4 hours later during wound closure, the patient developed intermittent airway obstruction accompanied by edema of the face and upper airway. Superior vena cava syndrome was suspected, and awake fiberoptic tracheal intubation was performed. Partial obstruction of the left brachiocephalic vein and right internal jugular vein were identified while the patient was in the radiology suite. Sympathetic block and increased venous return from the left arm likely contributed to his airway obstruction that mimicked superior vena cava syndrome.

15.
Paediatr Anaesth ; 23(12): 1193-8, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23890290

RESUMEN

BACKGROUND: Paravertebral perineural blocks are used to prevent pain in the thoracoabdominal dermatomes. Traditionally, a landmark-based technique is used in children, while ultrasound-guided (UG) techniques are being employed in adult patients. OBJECTIVE: To describe an UG technique for placement of thoracic paravertebral nerve block (TPVNB) catheters in pediatric patients. METHODS: Retrospective chart review of a series of 22 pediatric patients' ages 6 months to 17 years with weights from 6.25 kg to 135 kg using a transverse in-plane technique. Catheters were placed both bilateral and unilateral for a variety of thoracic and abdominal procedures. A linear ultrasound transducer was used in all cases with frequency of oscillation and transducer length chosen based on individual patient characteristics of age, weight, and BMI. RESULTS: The median pain scores at 12, 24, 36, and 48 h were 1.2 (interquartile range, 4.5), 0.84 (interquartile range 3.0), 1.6 (interquartile range 2.9), and 0.83 (interquartile range 1.74), respectively. The median dose of opioid expressed as morphine equivalents consumed during the first 24 h after surgery was 0.14 mg·kg(-1) (interquartile range, 0.78 mg·kg(-1) ) and from 24 to 48 h the median dose was 0.11 mg·kg(-1) (interquartile range 0.44 mg·kg(-1) ). No complications were noted, and catheters were left an average of 3 days with a range of 1-5 days with good pain relief. CONCLUSION: This technical description demonstrates the feasibility of placing PVNB catheters using a transverse in-line ultrasound-guided technique in a wide range of pediatric patients.


Asunto(s)
Anestesia Raquidea/métodos , Bloqueo Nervioso/métodos , Columna Vertebral/diagnóstico por imagen , Ultrasonografía Intervencional/métodos , Adolescente , Anestesia General , Índice de Masa Corporal , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Narcóticos/administración & dosificación , Narcóticos/uso terapéutico , Dimensión del Dolor , Dolor Postoperatorio/tratamiento farmacológico
16.
Biomed Opt Express ; 4(5): 760-71, 2013 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-23667791

RESUMEN

Miniature optical sensors that can detect blood vessels in front of advancing instruments will significantly benefit many interventional procedures. Towards this end, we developed a thin and flexible coherence-gated Doppler (CGD) fiber probe (O.D. = 0.125 mm) that can be integrated with minimally-invasive tools to provide real-time audio feedback of blood flow at precise locations in front of the probe. Coherence-gated Doppler (CGD) is a hybrid technology with features of laser Doppler flowmetry (LDF) and Doppler optical coherence tomography (DOCT). Because of its confocal optical design and coherence-gating capabilities, CGD provides higher spatial resolution than LDF. And compared to DOCT imaging systems, CGD is simpler and less costly to produce. In vivo studies of rat femoral vessels using CGD demonstrate its ability to distinguish between artery, vein and bulk movement of the surrounding soft tissue. Finally, by placing the CGD probe inside a 30-gauge needle and advancing it into the brain of an anesthetized sheep, we demonstrate that it is capable of detecting vessels in front of advancing probes during simulated stereotactic neurosurgical procedures. Using simultaneous ultrasound (US) monitoring from the surface of the brain we show that CGD can detect at-risk blood vessels up to 3 mm in front of the advancing probe. The improved spatial resolution afforded by coherence gating combined with the simplicity, minute size and robustness of the CGD probe suggest it may benefit many minimally invasive procedures and enable it to be embedded into a variety of surgical instruments.

18.
Reg Anesth Pain Med ; 37(5): 525-9, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22878523

RESUMEN

BACKGROUND: The potential for injection into the brachial plexus root at cervical levels must be considered during interscalene block or chronic pain interventions in the neck, but this phenomenon has not been well studied. In this investigation, we performed injections into the brachial plexus roots of unembalmed cadavers, with real-time ultrasound guidance, to evaluate the proximal and distal spread of the injected fluids, the potential of the injectate to reach the neuraxis, and whether the injectate could migrate into the actual substance of the spinal cord itself. METHODS: A solution of particulate dye mixed with local anesthetic was injected into 8 brachial plexus roots at a lower cervical level, in unembalmed cadaver specimens, utilizing an automated pump and pressure monitor. Two injections were made adjacent to nerve roots as controls. The specimens were then dissected, and gross and microscopic analysis utilized to determine the distribution of the dye and the structures affected. RESULTS: The mean peak pressure achieved during plexus root injections was 48.9 psi. After injections into the plexus root, dye was evident within the neural tissue at the level of injection and spread primarily distally in the plexus. In 1 of 8 injections into the brachial plexus root, the dye in the injectate spread proximally into the spinal canal, but in none of the injections was the spinal cord affected by the dye. CONCLUSIONS: Injection directly into the neural tissue of a brachial plexus root in a cadaver model produced high pressures suggestive of intrafascicular injection and widespread flow of the injectate through the distal brachial plexus. However, proximal movement of the dye-containing injectate was more restricted, with only 1 of the injections leading to epidural spread and no apparent effects on the spinal cord.


Asunto(s)
Plexo Braquial/efectos de los fármacos , Plexo Braquial/metabolismo , Raíces Nerviosas Espinales/efectos de los fármacos , Raíces Nerviosas Espinales/metabolismo , Amidas/administración & dosificación , Amidas/metabolismo , Anestésicos Locales/administración & dosificación , Anestésicos Locales/metabolismo , Plexo Braquial/diagnóstico por imagen , Cadáver , Colorantes Fluorescentes/administración & dosificación , Colorantes Fluorescentes/metabolismo , Humanos , Inyecciones , Bloqueo Nervioso/métodos , Ropivacaína , Raíces Nerviosas Espinales/diagnóstico por imagen , Distribución Tisular/efectos de los fármacos , Distribución Tisular/fisiología , Ultrasonografía Intervencional/métodos