Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Total Environ ; 791: 148277, 2021 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-34119780

RESUMEN

Accurate and temporally consistent measurements of light absorbing aerosol (LAA) heating rate (HR) and of its source apportionment (fossil-fuel, FF; biomass-burning, BB) and speciation (black and brown Carbon; BC, BrC) are needed to evaluate LAA short-term climate forcing. For this purpose, wavelength- and time-dependent accurate LAA absorption coefficients are required. HR was experimentally determined and apportioned (sources/species) in the EMEP/ACTRIS/COLOSSAL-2018 winter campaign in Milan (urban-background site). Two Aethalometers (AE31/AE33) were installed together with a MAAP, CPC, OPC, a low volume sampler (PM2.5) and radiation instruments. AE31/AE33 multiple-scattering correction factors (C) were determined using two reference systems for the absorption coefficient: 1) 5-wavelength PP_UniMI with low time resolution (12 h, applied to PM2.5 samples); 2) timely-resolved MAAP data at a single wavelength. Using wavelength- and time-independent C values for the AE31 and AE33 obtained with the same reference device, the total HR showed a consistency (i.e. reproducibility) with average values comparable at 95% probability. However, if different reference devices/approaches are used, i.e. MAAP is chosen as reference instead of a PP_UniMI, the HR can be overestimated by 23-30% factor (by both AE31/AE33). This became more evident focusing on HR apportionment: AE33 data (corrected by a wavelength- and time-independent C) showed higher HRFF (+24 ± 1%) and higher HRBC (+10 ± 1%) than that of AE31. Conversely, HRBB and HRBrC were -28 ± 1% and -29 ± 1% lower for AE33 compared to AE31. These inconsistencies were overcome by introducing a wavelength-dependent Cλ for both AE31 and AE33, or using multi-wavelength apportionment methods, highlighting the need for further studies on the influence of wavelength corrections for HR determination. Finally, the temporally-resolved determination of C resulted in a diurnal cycle of the HR not statistically different whatever the source- speciation- apportionment used.


Asunto(s)
Contaminantes Atmosféricos , Calefacción , Aerosoles/análisis , Contaminantes Atmosféricos/análisis , Carbono/análisis , Monitoreo del Ambiente , Material Particulado , Reproducibilidad de los Resultados
2.
Acta Paediatr ; 106(10): 1564-1568, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28580602

RESUMEN

AIM: Alleviating pain in neonates should be the goal of all caregivers. We evaluated whether recorded maternal voices were safe and effective in limiting pain in preterm infants undergoing heel lance procedures in the neonatal intensive care unit of an Italian children's hospital. METHODS: This prospective, controlled study took place from December 2013 to December 2015. We enrolled 40 preterm infants, born at a 26-34 weeks of gestation, at a corrected gestational age 29-36 weeks and randomised them to listen or not listen to a recording of their mother's voice during a painful, routine heel lance for blood collection. Changes in the infants' Premature Infant Pain Profile, heart rate, oxygen saturation and blood pressure during the procedure were compared by analysis of variance. Possible side effects, of apnoea, bradycardia, seizures and vomiting, were also recorded. RESULTS: Both groups showed a marked increase in PIPP scores and decrease in oxygen saturation during the procedure, but infants in the treatment group had significantly lower PIPP scores (p = 0.00002) and lower decreases in oxygen saturation (p = 0.0283). No significant side effects were observed. CONCLUSION: Using recorded maternal voices to limit pain in preterm infants undergoing heel lance procedures appeared safe and effective.


Asunto(s)
Cuidado Intensivo Neonatal/métodos , Manejo del Dolor/métodos , Recursos Audiovisuales , Humanos , Recién Nacido , Recien Nacido Prematuro , Conducta Materna , Dimensión del Dolor , Estudios Prospectivos , Voz
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...