Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Neuroscience ; 426: 50-58, 2020 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-31785357

RESUMEN

Electroencephalography (EEG) as a biomarker of neuromodulation by High Definition transcranial Direct Current Stimulation (HD-tDCS) offers promise as both techniques are deployable and can be integrated into a single head-gear. The present research addresses experimental design for separating focal EEG effect of HD-tDCS in the '4-cathode × 1-anode' (4 × 1) montage over the left motor area (C3). We assessed change in offline EEG at the homologous central (C3, C4), and occipital (O1, O2) locations. Interhemispheric asymmetry was accessed for background EEG at standard frequency bands; and for the intermittent photic stimulation (IPS). EEG was compared post- vs pre-intervention in three HD-tDCS arms: Active (2 mA), Sham (ramp up/down at the start and end), and No-Stimulation (device was not powered), each intervention lasting 20 min. The asymmetric background EEG changes were only in the central areas with right-side amplitude spectra prevalence, most pronounced in the no-stimulation arm, where they depended on comparison time-points and were consistent with markers of transition between drowsiness and vigilance - bilateral decrease in the delta and asymmetric central increase in the alpha and beta1 bands. For the active arm, similar but less pronounced changes occurred in the alpha band. In contrast, responses to IPS developed similar asymmetric amplitude increase at four harmonics of the IPS of 3 Hz only in the active arm, against a background of a brain-wide symmetric increase in both active and sham arms. Our protocols and analyses suggest methodological caveats for how EEG of tDCS studies could be conducted to isolate putative brain polarization outcomes.


Asunto(s)
Encéfalo/fisiología , Electroencefalografía , Estimulación Luminosa , Estimulación Transcraneal de Corriente Directa , Adulto , Electroencefalografía/métodos , Femenino , Voluntarios Sanos , Humanos , Masculino , Estimulación Luminosa/métodos , Proyectos de Investigación , Estimulación Transcraneal de Corriente Directa/métodos
3.
Exp Neurol ; 297: 179-189, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28803750

RESUMEN

Cervical injuries are the most common form of SCI. In this study, we used a neuromodulatory approach to promote skilled movement recovery and repair of the corticospinal tract (CST) after a moderately severe C4 midline contusion in adult rats. We used bilateral epidural intermittent theta burst (iTBS) electrical stimulation of motor cortex to promote CST axonal sprouting and cathodal trans-spinal direct current stimulation (tsDCS) to enhance spinal cord activation to motor cortex stimulation after injury. We used Finite Element Method (FEM) modeling to direct tsDCS to the cervical enlargement. Combined iTBS-tsDCS was delivered for 30min daily for 10days. We compared the effect of stimulation on performance in the horizontal ladder and the Irvine Beattie and Bresnahan forepaw manipulation tasks and CST axonal sprouting in injury-only and injury+stimulation animals. The contusion eliminated the dorsal CST in all animals. tsDCS significantly enhanced motor cortex evoked responses after C4 injury. Using this combined spinal-M1 neuromodulatory approach, we found significant recovery of skilled locomotion and forepaw manipulation skills compared with injury-only controls. The spared CST axons caudal to the lesion in both animal groups derived mostly from lateral CST axons that populated the contralateral intermediate zone. Stimulation enhanced injury-dependent CST axonal outgrowth below and above the level of the injury. This dual neuromodulatory approach produced partial recovery of skilled motor behaviors that normally require integration of posture, upper limb sensory information, and intent for performance. We propose that the motor systems use these new CST projections to control movements better after injury.


Asunto(s)
Axones/fisiología , Corteza Motora/fisiología , Tractos Piramidales/fisiología , Traumatismos de la Médula Espinal/terapia , Estimulación de la Médula Espinal/métodos , Médula Espinal/fisiología , Animales , Vértebras Cervicales , Contusiones/fisiopatología , Contusiones/terapia , Electromiografía/métodos , Femenino , Ratas , Ratas Sprague-Dawley , Recuperación de la Función/fisiología , Traumatismos de la Médula Espinal/fisiopatología
4.
Clin Neurophysiol ; 128(9): 1774-1809, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28709880

RESUMEN

Low intensity transcranial electrical stimulation (TES) in humans, encompassing transcranial direct current (tDCS), transcutaneous spinal Direct Current Stimulation (tsDCS), transcranial alternating current (tACS), and transcranial random noise (tRNS) stimulation or their combinations, appears to be safe. No serious adverse events (SAEs) have been reported so far in over 18,000 sessions administered to healthy subjects, neurological and psychiatric patients, as summarized here. Moderate adverse events (AEs), as defined by the necessity to intervene, are rare, and include skin burns with tDCS due to suboptimal electrode-skin contact. Very rarely mania or hypomania was induced in patients with depression (11 documented cases), yet a causal relationship is difficult to prove because of the low incidence rate and limited numbers of subjects in controlled trials. Mild AEs (MAEs) include headache and fatigue following stimulation as well as prickling and burning sensations occurring during tDCS at peak-to-baseline intensities of 1-2mA and during tACS at higher peak-to-peak intensities above 2mA. The prevalence of published AEs is different in studies specifically assessing AEs vs. those not assessing them, being higher in the former. AEs are frequently reported by individuals receiving placebo stimulation. The profile of AEs in terms of frequency, magnitude and type is comparable in healthy and clinical populations, and this is also the case for more vulnerable populations, such as children, elderly persons, or pregnant women. Combined interventions (e.g., co-application of drugs, electrophysiological measurements, neuroimaging) were not associated with further safety issues. Safety is established for low-intensity 'conventional' TES defined as <4mA, up to 60min duration per day. Animal studies and modeling evidence indicate that brain injury could occur at predicted current densities in the brain of 6.3-13A/m2 that are over an order of magnitude above those produced by tDCS in humans. Using AC stimulation fewer AEs were reported compared to DC. In specific paradigms with amplitudes of up to 10mA, frequencies in the kHz range appear to be safe. In this paper we provide structured interviews and recommend their use in future controlled studies, in particular when trying to extend the parameters applied. We also discuss recent regulatory issues, reporting practices and ethical issues. These recommendations achieved consensus in a meeting, which took place in Göttingen, Germany, on September 6-7, 2016 and were refined thereafter by email correspondence.


Asunto(s)
Encéfalo/fisiología , Guías de Práctica Clínica como Asunto/normas , Estimulación Transcraneal de Corriente Directa/ética , Estimulación Transcraneal de Corriente Directa/normas , Animales , Quemaduras por Electricidad/etiología , Quemaduras por Electricidad/prevención & control , Humanos , Estimulación Transcraneal de Corriente Directa/efectos adversos
5.
Eur Psychiatry ; 41: 21-29, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-28049077

RESUMEN

BACKGROUND: Extensive clinical research has shown that the efficacy and cognitive outcomes of electroconvulsive therapy (ECT) are determined, in part, by the type of electrode placement used. Bitemporal ECT (BT, stimulating electrodes placed bilaterally in the frontotemporal region) is the form of ECT with relatively potent clinical and cognitive side effects. However, the reasons for this are poorly understood. OBJECTIVE: This study used computational modelling to examine regional differences in brain excitation between BT, Bifrontal (BF) and Right Unilateral (RUL) ECT, currently the most clinically-used ECT placements. Specifically, by comparing similarities and differences in current distribution patterns between BT ECT and the other two placements, the study aimed to create an explanatory model of critical brain sites that mediate antidepressant efficacy and sites associated with cognitive, particularly memory, adverse effects. METHODS: High resolution finite element human head models were generated from MRI scans of three subjects. The models were used to compare differences in activation between the three ECT placements, using subtraction maps. RESULTS AND CONCLUSION: In this exploratory study on three realistic head models, Bitemporal ECT resulted in greater direct stimulation of deep midline structures and also left temporal and inferior frontal regions. Interpreted in light of existing knowledge on depressive pathophysiology and cognitive neuroanatomy, it is suggested that the former sites are related to efficacy and the latter to cognitive deficits. We hereby propose an approach using binarised subtraction models that can be used to optimise, and even individualise, ECT therapies.


Asunto(s)
Cognición/fisiología , Disfunción Cognitiva , Estimulación Encefálica Profunda/efectos adversos , Terapia Electroconvulsiva/efectos adversos , Lóbulo Frontal , Lóbulo Temporal , Disfunción Cognitiva/diagnóstico , Disfunción Cognitiva/etiología , Disfunción Cognitiva/fisiopatología , Simulación por Computador , Estimulación Encefálica Profunda/métodos , Terapia Electroconvulsiva/métodos , Análisis de Elementos Finitos , Lóbulo Frontal/diagnóstico por imagen , Lóbulo Frontal/fisiopatología , Humanos , Imagen por Resonancia Magnética , Lóbulo Temporal/diagnóstico por imagen , Lóbulo Temporal/fisiopatología , Resultado del Tratamiento
6.
Brain Stimul ; 9(5): 720-729, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27198577

RESUMEN

BACKGROUND: Response inhibition is a critical executive function, enabling the adaptive control of behavior in a changing environment. The inferior frontal cortex (IFC) is considered to be critical for response inhibition, leading researchers to develop transcranial direct current stimulation (tDCS) montages attempting to target the IFC and improve inhibitory performance. However, conventional tDCS montages produce diffuse current through the brain, making it difficult to establish causality between stimulation of any one given brain region and resulting behavioral changes. Recently, high-definition tDCS (HD-tDCS) methods have been developed to target brain regions with increased focality relative to conventional tDCS. OBJECTIVE: Remarkably few studies have utilized HD-tDCS to improve cognitive task performance, however, and no study has directly compared the behavioral effects of HD-tDCS to conventional tDCS. METHODS: In the present study, participants received either HD-tDCS or conventional tDCS to the IFC during performance of a response inhibition task (stop-signal task, SST) or a control task (choice reaction time task, CRT). A third group of participants completed the same behavioral protocols, but received tDCS to a control site (mid-occipital cortex). Post-stimulation improvement in SST performance was analyzed as a function of tDCS group and the task performed during stimulation using both conventional and Bayesian parameter estimation analyses. RESULTS: Bayesian estimation of the effects of HD- and conventional tDCS to IFC relative to control site stimulation demonstrated enhanced response inhibition for both conditions. No improvements were found after control task (CRT) training in any tDCS condition. CONCLUSION: Results support the use of both HD- and conventional tDCS to the IFC for improving response inhibition, providing empirical evidence that HD-tDCS can be used to facilitate performance on an executive function task.


Asunto(s)
Función Ejecutiva/fisiología , Lóbulo Frontal/fisiología , Inhibición Psicológica , Estimulación Transcraneal de Corriente Directa/métodos , Teorema de Bayes , Femenino , Humanos , Masculino , Pruebas Neuropsicológicas , Tiempo de Reacción/fisiología
7.
Sci Rep ; 6: 25160, 2016 05 05.
Artículo en Inglés | MEDLINE | ID: mdl-27146700

RESUMEN

During value-based decision making, ventromedial prefrontal cortex (vmPFC) is thought to support choices by tracking the expected gain from different outcomes via a competition-based process. Using a computational neurostimulation approach we asked how perturbing this region might alter this competition and resulting value decisions. We simulated a perturbation of neural dynamics in a biophysically informed model of decision-making through in silico depolarization at the level of neuronal ensembles. Simulated depolarization increased baseline firing rates of pyramidal neurons, which altered their susceptibility to background noise, and thereby increased choice stochasticity. These behavioural predictions were compared to choice behaviour in healthy participants performing similar value decisions during transcranial direct current stimulation (tDCS), a non-invasive brain stimulation technique. We placed the soma depolarizing electrode over medial frontal PFC. In line with model predictions, this intervention resulted in more random choices. By contrast, no such effect was observed when placing the depolarizing electrode over lateral PFC. Using a causal manipulation of ventromedial and lateral prefrontal function, these results provide support for competition-based choice dynamics in human vmPFC, and introduce computational neurostimulation as a mechanistic assay for neurostimulation studies of cognition.


Asunto(s)
Conducta de Elección , Corteza Prefrontal/fisiología , Estimulación Transcraneal de Corriente Directa , Adulto , Femenino , Humanos , Masculino , Modelos Neurológicos , Adulto Joven
8.
Clin Neurophysiol ; 127(2): 1031-1048, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26652115

RESUMEN

Transcranial electrical stimulation (tES), including transcranial direct and alternating current stimulation (tDCS, tACS) are non-invasive brain stimulation techniques increasingly used for modulation of central nervous system excitability in humans. Here we address methodological issues required for tES application. This review covers technical aspects of tES, as well as applications like exploration of brain physiology, modelling approaches, tES in cognitive neurosciences, and interventional approaches. It aims to help the reader to appropriately design and conduct studies involving these brain stimulation techniques, understand limitations and avoid shortcomings, which might hamper the scientific rigor and potential applications in the clinical domain.


Asunto(s)
Encéfalo/fisiología , Estimulación Transcraneal de Corriente Directa/métodos , Cognición/fisiología , Humanos , Estimulación Transcraneal de Corriente Directa/instrumentación
9.
Clin Res Regul Aff ; 32(1): 22-35, 2015 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-25983531

RESUMEN

The field of transcranial electrical stimulation (tES) has experienced significant growth in the past 15 years. One of the tES techniques leading this increased interest is transcranial direct current stimulation (tDCS). Significant research efforts have been devoted to determining the clinical potential of tDCS in humans. Despite the promising results obtained with tDCS in basic and clinical neuroscience, further progress has been impeded by a lack of clarity on international regulatory pathways. We therefore convened a group of research and clinician experts on tDCS to review the research and clinical use of tDCS. In this report, we review the regulatory status of tDCS, and we summarize the results according to research, off-label and compassionate use of tDCS in the following countries: Australia, Brazil, France, Germany, India, Iran, Italy, Portugal, South Korea, Taiwan and United States. Research use, off label treatment and compassionate use of tDCS are employed in most of the countries reviewed in this study. It is critical that a global or local effort is organized to pursue definite evidence to either approve and regulate or restrict the use of tDCS in clinical practice on the basis of adequate randomized controlled treatment trials.

10.
Artículo en Inglés | MEDLINE | ID: mdl-26736243

RESUMEN

The beneficial effects of transcranial direct current stimulation (tDCS) has been demonstrated, but the neuroscientific community is working to increase its efficiency. A promising line of advancement may be reducing the inter-individual variability of the response through the personalization of the stimulation, adapted to fit the structural and functional features of individual subjects. In this paper, we approach the personalization of stimulation parameters using modeling, a powerful tool to test montages enabling the optimization of brain's targeting.


Asunto(s)
Medicina de Precisión/métodos , Estimulación Transcraneal de Corriente Directa/métodos , Encéfalo/fisiología , Electroencefalografía/métodos , Epilepsia/fisiopatología , Epilepsia/terapia , Análisis de Elementos Finitos , Humanos , Modelos Neurológicos
12.
Neuroscience ; 265: 21-7, 2014 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-24508152

RESUMEN

Orbitofrontal reality filtering denotes a memory control mechanism necessary to keep thought and behavior in phase with reality. Its failure induces reality confusion as evident in confabulation and disorientation. In the present study, we explored the influence of orbitofrontal transcranial direct current stimulation (tDCS) on reality filtering. Twenty healthy human subjects made a reality filtering task, while receiving cathodal, anodal, or sham stimulation over the frontal pole in three sessions separated by at least 1week. Computational models predicted that this montage can produce polarity-specific current flow across the posterior medial orbitofrontal cortex (OFC). In agreement with our hypothesis, we found that cathodal tDCS over the frontal pole specifically impaired reality filtering in comparison to anodal and sham stimulation. This study shows that reality filtering, an orbitofrontal function, can be modulated with tDCS.


Asunto(s)
Memoria/fisiología , Corteza Prefrontal/fisiología , Reconocimiento en Psicología/fisiología , Adolescente , Adulto , Estimulación Eléctrica , Femenino , Lóbulo Frontal/fisiología , Humanos , Masculino , Adulto Joven
13.
Neuroimage ; 57(3): 885-91, 2011 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-21620985

RESUMEN

Transcranial direct current stimulation (tDCS) has recently emerged as a promising approach to enhance neurorehabilitative outcomes. However, little is known about how the local electrical field generated by tDCS relates to underlying neuroplastic changes and behavior. To address this question, we present a case study analysis of an individual with hemianopia due to stroke and who benefited from a combined visual rehabilitation training and tDCS treatment program. Activation associated with a visual motion perception task (obtained by functional magnetic resonance imaging; fMRI) was used to characterize local changes in brain activity at baseline and after training. Individualized, high-resolution electrical field modeling reproducing precise cerebral and lesioned tissue geometry, predicted distortions of current flow in peri-lesional areas and diffuse clusters of peak electric fields. Using changes in fMRI signal as an index of cortical recovery, correlations to the electrical field map were determined. Significant correlations between the electrical field and change in fMRI signal were region specific including cortical areas under the anode electrode and peri-lesional visual areas. These patterns were consistent with effective tDCS facilitated rehabilitation. We describe the methodology used to analyze tDCS mechanisms through combined fMRI and computational modeling with the ultimate goal of developing a rationale for individualized therapy.


Asunto(s)
Mapeo Encefálico , Encéfalo/fisiopatología , Hemianopsia/fisiopatología , Plasticidad Neuronal/fisiología , Accidente Cerebrovascular/fisiopatología , Estimulación Magnética Transcraneal , Femenino , Hemianopsia/etiología , Hemianopsia/rehabilitación , Humanos , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Magnética , Persona de Mediana Edad , Accidente Cerebrovascular/complicaciones , Rehabilitación de Accidente Cerebrovascular , Percepción Visual/fisiología
15.
J Neural Eng ; 7(1): 16005, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20075507

RESUMEN

Deep brain stimulation (DBS) achieves therapeutic outcome through generation of electric fields (EF) in the vicinity of energized electrodes. Targeted brain regions are highly vascularized, and it remains unknown if DBS electric fields modulate blood-brain barrier (BBB) function, either through electroporation of individual endothelial cells or electro-permeation of barrier tight junctions. In our study, we calculated the intensities of EF generated around energized Medtronic 3387 and 3389 DBS leads by using a finite element model. Then we designed a novel stimulation system to study the effects of such fields with DBS-relevant waveforms and intensities on bovine aortic endothelial cell (BAEC) monolayers, which were used as a basic analog for the blood-brain barrier endothelium. Following 5 min of stimulation, we observed a transient increase in endothelial hydraulic conductivity (Lp) that could be related to the disruption of the tight junctions (TJ) between cells, as suggested by zonula occludens-1 (ZO-1) protein staining. This 'electro-permeation' occurred in the absence of cell death or single cell electroporation, as indicated by propidium iodide staining and cytosolic calcein uptake. Our in vitro results, using uniform fields and BAEC monolayers, thus suggest that electro-permeation of the BBB may occur at electric field intensities below those inducing electroporation and within intensities generated near DBS electrodes. Further studies are necessary to address potential BBB disruption during clinical studies, with safety and efficacy implications.


Asunto(s)
Estimulación Encefálica Profunda , Campos Electromagnéticos , Células Endoteliales/fisiología , Animales , Aorta/fisiología , Barrera Hematoencefálica/fisiología , Encéfalo/fisiología , Permeabilidad Capilar/fisiología , Bovinos , Muerte Celular/fisiología , Membrana Celular/fisiología , Permeabilidad de la Membrana Celular/fisiología , Células Cultivadas , Estimulación Encefálica Profunda/instrumentación , Estimulación Encefálica Profunda/métodos , Conductividad Eléctrica , Electrodos , Electroporación , Proteínas de la Membrana/metabolismo , Modelos Biológicos , Fosfoproteínas/metabolismo , Uniones Estrechas/fisiología , Factores de Tiempo , Agua/metabolismo , Proteína de la Zonula Occludens-1
16.
Radiat Prot Dosimetry ; 106(4): 321-3, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-14690274

RESUMEN

Electric fields applied to brain tissue will affect cellular properties. They will hyperpolarise the ends of cells closest to the positive part of the field, and depolarise ends closest to the negative. In the case of neurons this affects excitability. How these changes in transmembrane potential are distributed depends on the length constant of the neuron, and on its geometry; if the neuron is electrically compact, the change in transmembrane potential becomes an almost linear function of distance in the direction of the field. Neurons from the mammalian hippocampus, maintained in tissue slices in vitro, are significantly affected by fields of around 1-5 V m(-1).


Asunto(s)
Campos Electromagnéticos , Hipocampo/efectos de la radiación , Potenciales de la Membrana/fisiología , Potenciales de la Membrana/efectos de la radiación , Red Nerviosa/fisiología , Red Nerviosa/efectos de la radiación , Neuronas/fisiología , Neuronas/efectos de la radiación , Animales , Relación Dosis-Respuesta en la Radiación , Electricidad , Hipocampo/fisiología , Humanos , Neuronas/química , Dosis de Radiación
17.
Neuroscience ; 115(1): 251-61, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-12401338

RESUMEN

The effect of quinine on pyramidal cell intrinsic properties, extracellular potassium transients, and epileptiform activity was studied in vitro using the rat hippocampal slice preparation. Quinine enhanced excitatory post-synaptic potentials and decreased fast- and slow-inhibitory post-synaptic potentials. Quinine reduced the peak potassium rise following tetanic stimulation but did not affect the potassium clearance rate. Epileptiform activity induced by either low-Ca(2+) or high-K(+) artificial cerebrospinal fluid (ACSF) was suppressed by quinine. The frequency of spontaneous inter-ictal bursting induced by picrotoxin, high-K(+), or 4-aminopyridine was significantly increased. In normal ACSF, quinine did not affect CA1 pyramidal cell resting membrane potential, input resistance, threshold for action potentials triggered by intracellular or extracellular stimulation, or the orthodromic and antidromic evoked population spike amplitude. The main effects of quinine on intrinsic cell properties were to increase action potential duration and to reduce firing frequency during sustained membrane depolarizations, but not at normal resting membrane potentials. This attenuation was enhanced at increasingly depolarized membrane potentials. These results suggest that quinine suppresses extracellular potassium transients and ictal activity and modulates inter-ictal activity by limiting the firing rate of cells in a voltage-dependent manner. Because quinine does not affect 'normal' neuronal function, it may merit consideration as an anticonvulsant.


Asunto(s)
Epilepsia/fisiopatología , Potenciales Postsinápticos Excitadores/efectos de los fármacos , Espacio Extracelular/efectos de los fármacos , Neuronas/efectos de los fármacos , Canales de Potasio/fisiología , Quinina/farmacología , Animales , Anticonvulsivantes/farmacología , Epilepsia/tratamiento farmacológico , Potenciales Postsinápticos Excitadores/fisiología , Espacio Extracelular/fisiología , Técnicas In Vitro , Masculino , Neuronas/fisiología , Quinina/uso terapéutico , Ratas , Ratas Sprague-Dawley
18.
J Physiol ; 537(Pt 1): 191-9, 2001 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-11711572

RESUMEN

1. Spontaneous non-synaptic epileptiform activity was induced by bathing rat hippocampal slices in low-Ca(2+) solution. Extracellular recordings from electrodes placed on both sides of a complete cut showed that non-synaptic activity was synchronized across the lesion. 2. Ion-selective electrode recordings showed that each event was accompanied by a transient increase in extracellular potassium that diffused across the lesion. The synchrony was destroyed when a thin film was inserted into the lesion site. 3. Local pressure ejection of KCl evoked an event that subsequently propagated across the lesion. 4. After a complete lesion was made, afterdischarges evoked on one half of a slice were not detected on the other half. 5. Voltage-sensitive dye imaging methods showed that epileptic activity propagated across the mechanical lesion without significant attenuation or additional delays. The velocity of the activity was consistent with that of the slow diffusion of a potassium wave. 6. Since field effects were significantly attenuated across the lesion and all gap junctions and cell processes across the lesion would be cut, these data show that extracellular diffusion, most probably potassium, is sufficient to synchronize populations of neurons and propagate slow frequency epileptiform activity.


Asunto(s)
Epilepsia/patología , Epilepsia/fisiopatología , Hipocampo/patología , Hipocampo/fisiopatología , Animales , Calcio/fisiología , Difusión , Electrofisiología , Técnicas In Vitro , Potasio/metabolismo , Ratas , Ratas Sprague-Dawley , Tiempo de Reacción , Sinapsis/fisiología
19.
J Physiol ; 531(Pt 1): 181-91, 2001 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-11179402

RESUMEN

1. Sinusoidal high frequency (20-50 Hz) electric fields induced across rat hippocampal slices were found to suppress zero-Ca2+, low-Ca2+, picrotoxin, and high-K+ epileptiform activity for the duration of the stimulus and for up to several minutes following the stimulus. 2. Suppression of spontaneous activity by high frequency stimulation was found to be frequency (< 500 Hz) but not orientation or waveform dependent. 3. Potassium-sensitive microelectrodes showed that block of epileptiform activity was always coincident with a stimulus-induced rise in extracellular potassium concentration during stimulation. Post-stimulus inhibition was always associated with a decrease in extracellular potassium activity below baseline levels. 4. Intracellular recordings and optical imaging with voltage-sensitive dyes showed that during suppression neurons were depolarized yet did not fire action potentials. 5. Direct injection of sinusoidal current into individual pyramidal cells did not result in a tonic depolarization. Injection of large direct current (DC) depolarized neurons and suppressed action potential generation. 6. These findings suggest that high frequency stimulation suppresses epileptiform activity by inducing potassium efflux and depolarization block.


Asunto(s)
Campos Electromagnéticos , Epilepsia/prevención & control , Hipocampo/fisiología , Animales , Calcio/fisiología , Estimulación Eléctrica , Electrofisiología , Epilepsia/fisiopatología , Antagonistas del GABA/farmacología , Procesamiento de Imagen Asistido por Computador , Técnicas de Placa-Clamp , Picrotoxina/farmacología , Potasio/metabolismo , Ratas , Ratas Sprague-Dawley
20.
J Neurophysiol ; 84(1): 274-80, 2000 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-10899202

RESUMEN

It is well established that exogenous electric fields can suppress activity obtained in different models of epileptiform discharge such as penicillin and high potassium. In the low-calcium model of epilepsy, spontaneous epileptiform bursting is generated in the absence of synaptic transmission. It has been suggested that ephaptic interactions play a critical role in neuronal synchronization and burst propagation in this nonsynaptic model. We, therefore, tested the hypothesis that low-calcium bursting induced in the CA1 region of transverse and longitudinal hippocampal slices should be highly sensitive to exogenous electric fields. Uniform, low amplitude DC electric fields were applied during spontaneous low-calcium epileptiform activity. Modulation and full suppression of epileptiform activity was observed at field strengths between 1 and 5 mV/mm, a value significantly lower than in other in vitro models of epilepsy. We further investigated the hypothesis that the efficacy of electrical fields was related to changes in the extracellular space. Our results suggest that the osmolality of the perfusate can modulate the efficacy of electric fields. It was also observed that the ability of a field to suppress or modulate low-calcium activity was highly dependent on its orientation, polarity, as well as magnitude. Finally, it was observed that the extracellular potassium "waves" that normally accompany individual epileptiform events was abolished when the individual events were suppressed. These results suggest that DC fields modulate and suppress low-calcium activity by directly polarizing CA1 pyramidal cells.


Asunto(s)
Calcio/farmacología , Campos Electromagnéticos , Epilepsia/fisiopatología , Hipocampo/fisiología , Células Piramidales/fisiología , Animales , Estimulación Eléctrica , Epilepsia/inducido químicamente , Hipocampo/citología , Hipocampo/efectos de los fármacos , Técnicas In Vitro , Potenciales de la Membrana/efectos de los fármacos , Potenciales de la Membrana/fisiología , Concentración Osmolar , Potasio/farmacología , Células Piramidales/efectos de los fármacos , Ratas , Ratas Sprague-Dawley , Transmisión Sináptica/efectos de los fármacos , Transmisión Sináptica/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA