Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
1.
Am J Cardiol ; 220: 56-66, 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38580040

RESUMEN

Peripheral artery disease (PAD) is associated with impaired blood flow in the lower extremities and histopathologic changes of the skeletal calf muscles, resulting in abnormal microvascular perfusion. We studied the use of convolution neural networks (CNNs) to differentiate patients with PAD from matched controls using perfusion pattern features from contrast-enhanced magnetic resonance imaging (CE-MRI) of the skeletal calf muscles. We acquired CE-MRI based skeletal calf muscle perfusion in 56 patients (36 patients with PAD and 20 matched controls). Microvascular perfusion imaging was performed after reactive hyperemia at the midcalf level, with a temporal resolution of 409 ms. We analyzed perfusion scans up to 2 minutes indexed from the local precontrast arrival time frame. Skeletal calf muscles, including the anterior muscle, lateral muscle, deep posterior muscle group, and the soleus and gastrocnemius muscles, were segmented semiautomatically. Segmented muscles were represented as 3-dimensional Digital Imaging and Communications in Medicine stacks of CE-MRI perfusion scans for deep learning (DL) analysis. We tested several CNN models for the 3-dimensional CE-MRI perfusion stacks to classify patients with PAD from matched controls. A total of 2 of the best performing CNNs (resNet and divNet) were selected to develop the final classification model. A peak accuracy of 75% was obtained for resNet and divNet. Specificity was 80% and 94% for resNet and divNet, respectively. In conclusion, DL using CNNs and CE-MRI skeletal calf muscle perfusion can discriminate patients with PAD from matched controls. DL methods may be of interest for the study of PAD.

2.
J Vasc Surg Venous Lymphat Disord ; : 101895, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38679142

RESUMEN

OBJECTIVE: Iliocaval thrombotic obstruction is a challenging condition, especially since thrombus age and corresponding pathological remodeling at presentation are unknown, which directly impacts management. Our aim was to assess the ability of Magnetic Resonance Imaging (MRI) in determining age thresholds of experimentally created inferior vena cava (IVC) thrombosis in pigs. METHODS: We used a previously described swine model of IVC thrombosis. Animals underwent MRI at baseline, immediately after thrombosis creation and after a follow-up period extending from 2 to 28 days. Thirteen animals were divided into 3 groups according to disease's chronicity: acute (AG, N1 = 5), subacute (SAG, N2 = 4) and chronic group (CG, N3 = 4) with a mean thrombosis age of respectively 6.4 ± 2.5, 15.7 ± 2.8 and 28 ± 5.7 days. A T1 weighted volumetric interpolated breath-hold examination sequence was used to anatomically delineate IVC thrombus as a region of interest. Three other MRI sequences were used to assess thrombus signal. RESULTS: Kruskal-Wallis showed a statistically significant difference in T1 relaxation times after contrast injection (P = .026) between the 3 groups of chronicity: AG (360.2 ± 102.5) was significantly different from CG (336.7 ± 55.2 ms; P = .003) and SAG (354.1 ± 89.7 ms) was significantly different from AG (P = .027). There was a statistically significant difference in native T2 relaxation times (P = .038) between the 3 groups: AG (160 ± 86.7 ms) was significantly different from SAG (142.3 ± 55.4 ms; P = .027) and SAG was significantly different from CG (178.4 ± 11.7 ms; P = .004). CONCLUSIONS: This study highlighted MRI characteristics in a swine model that may have the potential to significantly differentiate a subacute and a chronic stage from an acute stage of deep venous thrombosis in humans. Further clinical studies in humans are warranted.

3.
Magn Reson Imaging ; 106: 31-42, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38065273

RESUMEN

Diagnosing and assessing the risk of peripheral artery disease (PAD) has long been a focal point for medical practitioners. The impaired blood circulation in PAD patients results in altered microvascular perfusion patterns in the calf muscles which is the primary location of intermittent claudication pain. Consequently, we hypothesized that changes in perfusion and increase in connective tissue could lead to alterations in the appearance or texture patterns of the skeletal calf muscles, as visualized with non-invasive imaging techniques. We designed an automatic pipeline for textural feature extraction from contrast-enhanced magnetic resonance imaging (CE-MRI) scans and used the texture features to train machine learning models to detect the heterogeneity in the muscle pattern among PAD patients and matched controls. CE-MRIs from 36 PAD patients and 20 matched controls were used for preparing training and testing data at a 7:3 ratio with cross-validation (CV) techniques. We employed feature arrangement and selection methods to optimize the number of features. The proposed method achieved a peak accuracy of 94.11% and a mean testing accuracy of 84.85% in a 2-class classification approach (controls vs. PAD). A three-class classification approach was performed to identify a high-risk PAD sub-group which yielded an average test accuracy of 83.23% (matched controls vs. PAD without diabetes vs. PAD with diabetes). Similarly, we obtained 78.60% average accuracy among matched controls, PAD treadmill exercise completers, and PAD exercise treadmill non-completers. Machine learning and imaging-based texture features may be of interest in the study of lower extremity ischemia.


Asunto(s)
Diabetes Mellitus , Enfermedad Arterial Periférica , Humanos , Enfermedad Arterial Periférica/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Claudicación Intermitente , Músculo Esquelético/diagnóstico por imagen , Músculo Esquelético/irrigación sanguínea
4.
J Endovasc Ther ; : 15266028231210228, 2023 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-37936418

RESUMEN

OBJECTIVE: In many studies on aortic disease, women are underrepresented. The present study aims to assess sex-specific morphometric differences and gain more insight into endovascular treatment of the ascending aorta (AA) and arch. METHODS: Electrocardiogram-gated cardiac computed tomography scans of 116 consecutive patients who were evaluated for transcatheter aortic valve replacement were retrospectively reviewed. Measurements of the AA and aortic arch were made in multiplanar views, perpendicular to the semi-automatic centerline. Multiple linear regression analysis was performed to identify predictors affecting AA and aortic arch diameter in men and women. Propensity score matching was used to investigate whether sex influences aortic morphology. RESULTS: In both sexes, body surface area (BSA) was identified as a positive predictor and diabetes as a negative predictor for aortic diameters. In men, age was identified as a positive predictor and smoking as a negative predictor for aortic diameters. Propensity score matching identified 40 pairs. Systolic and diastolic mean diameters and AA length were significantly wider in men. On average, male aortas were 7.4% wider than female aortas, both in systole and diastole. CONCLUSIONS: The present analysis demonstrates that, in women, increased BSA is associated with increased aortic arch diameters, while diabetes is associated with decreased AA and arch diameters. In men, increased BSA and age are associated with increased AA and arch diameters, while smoking and diabetes are associated with decreased AA and arch diameters. Men were confirmed to have 7.4% greater AA and arch diameters than women. CLINICAL IMPACT: Men had 7.4% greater ascending aorta and arch diameters than women in a retrospective cohort, gated computed tomography-based study of 116 patients. Sex-specific differences in ascending aortic and arch size should be considered by aortic endovascular device manufacturers and physicians when developing ascending and arch endografts and planning aortic interventions.

5.
Eur J Vasc Endovasc Surg ; 66(6): 775-782, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37201718

RESUMEN

OBJECTIVE: To describe the trends in management and outcomes of patients with acute type B aortic dissection in the International Registry of Acute Aortic Dissection. METHODS: From 1996 - 2022, 3 908 patients were divided into similar sized quartiles (T1, T2, T3, and T4). In hospital outcomes were analysed for each quartile. Survival rates following admission were compared using Kaplan-Meier analyses with Mantel-Cox Log rank tests. RESULTS: Endovascular treatment increased from 19.1% in T1 to 37.2% in T4 (ptrend < .001). Correspondingly, medical therapy decreased from 65.7% in T1 to 54.0% in T4 (ptrend < .001), and open surgery from 14.8% in T1 to 7.0% in T4 (ptrend < .001). In hospital mortality decreased in the overall cohort from 10.7% in T1 to 6.1% in T4 (ptrend < .001), as well as in medically, endovascularly and surgically treated patients (ptrend = .017, .033, and .011, respectively). Overall post-admission survival at three years increased (T1: 74.8% vs. T4: 77.3%; p = .006). CONCLUSION: Considerable changes in the management of acute type B aortic dissection were observed over time, with a significant increase in the use of endovascular treatment and a corresponding reduction in open surgery and medical management. These changes were associated with a decreased overall in hospital and three year post-admission mortality rate among quartiles.

6.
J Vasc Interv Radiol ; 34(8): 1345-1352, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37028705

RESUMEN

PURPOSE: To evaluate the radiation protection offered by an exoskeleton-based radiation protection system (Stemrad MD) and to compare it with that offered by conventional lead aprons. METHODS: The experimental setup involved 2 anthropomorphic phantoms, an operator, a patient, and a C-arm as the x-ray radiation source. Thermoluminescent detectors were used to measure radiation doses to different radiosensitive body parts on the operator phantom both with the exoskeleton and a conventional lead apron at the left radial and right femoral positions. Detected radiation doses for the exoskeleton and lead apron for different body parts and positions were compared. RESULTS: At the left radial position, the mean radiation dose (mGy) reduction by the exoskeleton compared with that by the lead apron was >90% for the left eye lens (0.22 ± 0.13 vs 5.18 ± 0.08; P < .0001), right eye lens (0.23 ± 0.13 vs 4.98 ± 0.10; P < .0001), left head (0.11 ± 0.16 vs 3.53 ± 0.07; P < .0001), right head (0.27 ± 0.09 vs 3.12 ± 0.10; P < .0001), and left brain (0.04 ± 0.08 vs 0.46 ± 0.07; P < .0001). At the right femoral position, radiation reduction was >90% for the left eye lens (0.14 ± 0.10 vs 4.16 ± 0.09; P < .0001), right eye lens (0.06 ± 0.08 vs 1.90 ± 0.11; P < .0001), left head (0.10 ± 0.08 vs 4.39 ± 0.08; P < .0001), left brain (0.03 ± 0.07 vs 1.44 ± 0.08; P < .0001), right brain (0.00 ± 0.14 vs 0.11 ± 0.13; P = .06), and thyroid (0.04 ± 0.07 vs 0.27 ± 0.09; P < .0001). Protection of the torso was equivalent to that offered by conventional lead aprons. CONCLUSIONS: The exoskeleton-based system provided superior radiation protection to the physician compared with that provided by conventional lead aprons. The effects are particularly impactful for the brain, eye lens, and head areas.


Asunto(s)
Dispositivo Exoesqueleto , Exposición Profesional , Protección Radiológica , Humanos , Dosis de Radiación , Ropa de Protección , Cabeza , Exposición Profesional/prevención & control
7.
J Endovasc Ther ; : 15266028231160661, 2023 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-36942629

RESUMEN

OBJECTIVE: Poor ergonomic posture during interventional procedures might lead to increased physical discomfort and work-related musculoskeletal disorders. Adjunctive equipment such as lead aprons (LAs) has been shown to increase ergonomic posture risk (EPR). The objective of this study was to evaluate the effectiveness of StemRad MD (StemRad Ltd., Tel Aviv, Israel), a weightless exoskeleton-based radiation protective ensemble, in reducing EPR on the operator using wearable inertial measurement unit (IMU) sensors. METHODS: A prospective, observational study was conducted at an academic hospital. Inertial measurement unit sensors were affixed to the upper back of 9 interventionalists to assess ergonomic risk posture during endovascular procedures while wearing a traditional LA or the StemRad MD radiation protection system. Total fluoroscopy time, procedure type, and ergonomic risk postures were recorded and analyzed. RESULTS: Twenty-one cases were performed with StemRad MD and 30 with LAs. Mean procedure time for the StemRad MD procedures was 48.4±23.3 minutes (range: 24-106 min), and for LA procedures, it was 34.66±25.83 minutes (range: 6-100 min) (p=.060). The operators assumed low-risk ergonomic positions in 96.1% of StemRad MD cases and in 62.9% of LA cases (p=.001), and high-risk ergonomic positions in 0% and 6.2%, respectively (p=.80). Mean EPR score for StemRad MD was 1.16, and for the LA, it was 1.49 (p=.001). CONCLUSIONS: StemRad MD significantly reduces the EPR to the torso compared with a LA-based radiation protection system. CLINICAL IMPACT: Poor ergonomic posture during interventional procedures might leas to work-related musculoskeletal disorders for healthcare workers. StemRad MD, a weightless, exoskeleton-based radiation protection system was shown to significantly reduce ergonomic posture risk to the torso compared to conventional lead aprons. This might lead to reduced physical discomfort for procedure-based specialists.

8.
J Am Heart Assoc ; 12(3): e027649, 2023 02 07.
Artículo en Inglés | MEDLINE | ID: mdl-36688362

RESUMEN

Background Computational fluid dynamics has shown good agreement with contrast-enhanced magnetic resonance imaging measurements in cardiovascular disease applications. We have developed a biomechanical model of microvascular perfusion using contrast-enhanced magnetic resonance imaging signal intensities derived from skeletal calf muscles to study peripheral artery disease (PAD). Methods and Results The computational microvascular model was used to study skeletal calf muscle perfusion in 56 individuals (36 patients with PAD, 20 matched controls). The recruited participants underwent contrast-enhanced magnetic resonance imaging and ankle-brachial index testing at rest and after 6-minute treadmill walking. We have determined associations of microvascular model parameters including the transfer rate constant, a measure of vascular leakiness; the interstitial permeability to fluid flow which reflects the permeability of the microvasculature; porosity, a measure of the fraction of the extracellular space; the outflow filtration coefficient; and the microvascular pressure with known markers of patients with PAD. Transfer rate constant, interstitial permeability to fluid flow, and microvascular pressure were higher, whereas porosity and outflow filtration coefficient were lower in patients with PAD than those in matched controls (all P values ≤0.014). In pooled analyses of all participants, the model parameters (transfer rate constant, interstitial permeability to fluid flow, porosity, outflow filtration coefficient, microvascular pressure) were significantly associated with the resting and exercise ankle-brachial indexes, claudication onset time, and peak walking time (all P values ≤0.013). Among patients with PAD, interstitial permeability to fluid flow, and microvascular pressure were higher, while porosity and outflow filtration coefficient were lower in treadmill noncompleters compared with treadmill completers (all P values ≤0.001). Conclusions Computational microvascular model parameters differed significantly between patients with PAD and matched controls. Thus, computational microvascular modeling could be of interest in studying lower extremity ischemia.


Asunto(s)
Enfermedad Arterial Periférica , Humanos , Enfermedad Arterial Periférica/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Claudicación Intermitente , Pierna/irrigación sanguínea , Músculo Esquelético , Perfusión
9.
J Endovasc Ther ; : 15266028221144590, 2022 Dec 24.
Artículo en Inglés | MEDLINE | ID: mdl-36565274
10.
EJVES Vasc Forum ; 57: 5-11, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36388464

RESUMEN

Objective: Assessment of the quality of the final product (QFP) is critical in simulation training, such as the clock face suture (CFS) exercise that is used to assess trainees' needle handling and suturing accuracy. Objective Structured Assessment of Technical Skill (OSATS) scores are the gold standard for the evaluation of trainees. The aim was to investigate variability in the use of OSATS checklists and to evaluate a semi-automatic method of suture analysis vs. OSATS scores. Methods: Details of 287 CFSs performed by trainees during Fundamentals in Vascular Surgery examinations were collected. All were rated according to a seven item OSATS checklist, including QFP score and an overall score by one or two expert surgeons immediately after completion. Interassessor variability was assessed for the CFS that were assessed by two assessors.In order to assess intra- and interassessor variability, 50 CFS pictures were chosen randomly and submitted to three expert surgeons to rate the QFP twice and to carry out a semi-automatic image analysis of each CFS and the estimated cumulative error (CE; mm) recorded. It was hypothesised that the CE correlates to OSATS checklist items or overall score. Variables were compared for correlation with OSATS results using a linear regression. A Pearson's test was used to confirm the proposed hypothesis. Results: Mean ± standard deviation overall score for the OSATS checklist was 20.61 ± 6.33. Inter- and intra-assessor correlation were statistically significant regarding OSATS checklist items. Both correlations presented a low coefficient of determination, indicating variability. The mean CE was 16.07 ± 4.84 mm, and the correlation between the QFP and CE was statistically significant, proving that CE is an objective metric by which to assess the QFP. Conclusion: OSATS score demonstrated intra- and interassessor variability, although there was a significant correlation between scores. CE is an objective metric that is not subject to assessor subjectivity or interassessor variability and is correlated with the gold standard of evaluation.

12.
J Endovasc Ther ; : 15266028221113752, 2022 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-35869618

RESUMEN

PURPOSE: To demonstrate the feasibility of Octafen technique, a novel endovascular configuration for the treatment of thoracoabdominal aortic aneurysms (TAAA). TECHNIQUE: Two patients with complex TAAA and high surgical risk were treated with Octafen endograft configuration in a hybrid operating room with computed tomography (CT)-fluoroscopy image fusion guidance, using 3D-3D fusion techniques to facilitate procedural success. The procedure is a modification of the previously-described Octopus technique for endovascular repair of TAAA. The main advantage of this technique is the ability to use devices to repair a TAAA with the combination of off-the-shelf and noninvestigational custom-made devices. The devices used are readily available to most practicing vascular surgeons, which provides an alternative treatment in case of limited access to investigational devices, in time-sensitive cases, and in patients with limited functional capacity who cannot undergo open repair. In the modification described herein, we use a combination of standard bifurcated endovascular aneurysm repair (EVAR) devices (Excluder; W.L. Gore & Associates, Flagstaff, Arizona) in combination with a 2-vessel renal fenestrated device (Z-Fen; Cook Medical, Bloomington, Indiana). The article describes a step-by-step approach to this technique to elucidate pitfalls, benefits, and advantages. CONCLUSION: The Octafen technique might offer an alternative option for thoracoabdominal aneurysm treatment circumventing the need for access to custom-made, investigational devices. CLINICAL IMPACT: In this manuscript, we describe a technique for endovascular repair of thoraco-abdominal aortic aneurysms that involves the combination of off-the-shelf and non-investigational, custom-made devices. The 'Octafen' technique provides a treatment alternative in case of limited access to investigational devices and can be adjusted according to patient anatomy.

13.
Eur J Vasc Endovasc Surg ; 63(4): 623-630, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35272950

RESUMEN

OBJECTIVE: To develop a large animal model of iliocaval deep venous thrombosis (DVT), which enables development and evaluation of interventional management and existing imaging modalities. METHODS: The experimental protocol consisted of a total endovascular approach. Pigs were percutaneously accessed through the right internal jugular and bilateral femoral veins. Three balloon catheters were inflated to induce venous stasis in the infrarenal inferior vena cava (IVC) and bilateral common iliac veins (CIVs). Hypercoagulability was induced by injecting 10 000 IU of thrombin. After 2.5 hours, the balloon catheters were removed before animal recovery. After seven, 14, 21, 28, or 35 days, animals were euthanised; the IVC and CIV were harvested en bloc, cross sectioned and prepared for histological examination. Multimodal imaging was performed before and after thrombus creation, and before animal euthanasia. RESULTS: Thirteen female domestic pigs with a mean weight of 59.3 kilograms were used. The mean maximum IVC diameter and area were 16.4 mm and 1.2 cm2, respectively. The procedure was successful in 12 animals with occlusive venous thrombosis in the region of interest on immediate post-operative magnetic resonance venography and a mean thrombus volume of 19.8 cm3. Clinical pathology results showed platelet consumption, D dimer increase, and inflammatory response. Histological evaluation demonstrated a red cell, fibrin, and platelet rich thrombus on day 1, with progressive inflammatory cell infiltration from day 7. Collagen deposition appeared in week 2 and neovascularisation in week 3. CONCLUSION: Endovascular occlusion combined with thrombin infusion is a reliable minimally invasive approach to produce acute and subacute DVT in a large animal model.


Asunto(s)
Procedimientos Endovasculares , Trombosis de la Vena , Animales , Modelos Animales de Enfermedad , Procedimientos Endovasculares/métodos , Femenino , Humanos , Vena Ilíaca/diagnóstico por imagen , Vena Ilíaca/cirugía , Stents , Porcinos , Trombina , Resultado del Tratamiento , Grado de Desobstrucción Vascular/fisiología , Vena Cava Inferior/diagnóstico por imagen , Vena Cava Inferior/cirugía , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/etiología , Trombosis de la Vena/terapia
15.
J Cardiovasc Surg (Torino) ; 62(6): 527-534, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34581554

RESUMEN

INTRODUCTION: Since the outbreak of the 2019 coronavirus (COVID-19), vascular specialists have faced dramatic changes in clinical and surgical practice. Although COVID-19 pulmonary signs and symptoms were the most pertinent problems initially, in the long term, cardiovascular complications became the most fearsome, with poor outcomes in terms of morbidity and mortality. Algorithms and decision-making procedures have been modified, not only to treat new clinical findings in COVID-19 positive patients, but also to avoid complications related to pulmonary and systemic infections. Additionally, COVID-19-negative patients experienced challenging management, due to hospital crowding, the risk of nosocomial COVID-19 transmission, and pandemic emergencies. In this context, aortic interventions were subject to several difficulties. First, in COVID-19-positive patients, there was the onset of new pathological scenarios including thrombotic manifestations and the subsequent complications. Second, in both COVID-19-negative and positive patients, there was a need to deliver optimal treatment with acceptable perioperative risks, forcing a rethinking of decision-making especially in terms of indications for treatments. The aim of this systematic review is to present evidence published on COVID-19 and aortic-related issues, highlighting some challenging aspects regarding management, treatment and outcomes. EVIDENCE ACQUISITION: Data search was performed on PubMed, Scopus and Web of Science, using as time range "January 1st, 2000 - May 1st, 2021." Only articles in English language were included. Key words used for the query were "Aorta" AND "COVID-19" OR "SARS-CoV-2." Furthermore, the NCBI database of "SARS-CoV-2 Resources" was interrogated to find further relevant studies. EVIDENCE SYNTHESIS: The search retrieved 416 papers; among these, 46 studies were eligible and reviewed in depth. The published literature suggests the existence of a hypercoagulable state in patients with COVID-19 disease occurring via direct and indirect mechanisms. COVID-19 infection seems to promote a prothrombotic status that aggravates vascular disease. Regardless of clinical laboratory or status, active COVID-19 infection is considered a risk factor for poor vascular surgery outcomes. Specifically, it is associated with a fourfold increased risk of death and a threefold increased risk of major adverse events. Prognosis of patients hospitalized with COVID-19 disease is often determined by the extent of pulmonary disease, although vascular complications also greatly affect outcomes. Nevertheless, although COVID­19 is highly morbid, in high­risk operations good outcomes can still be achieved even in elderly patients with COVID­19. CONCLUSIONS: In the case of aortic disease during active COVID-19 infection, poor outcomes are associated with COVID-19 vascular and non-vascular complications, while for COVID-19-negative patients not much changed in terms of outcomes, despite the difficulties in management. Endovascular repair, when possible, minimized the impact of treatment, reducing the risk of COVID-related postoperative complications or acquired infection in negative patients.


Asunto(s)
Anticoagulantes/uso terapéutico , Enfermedades de la Aorta/cirugía , Coagulación Sanguínea/efectos de los fármacos , COVID-19/terapia , Procedimientos Endovasculares , Trombofilia/tratamiento farmacológico , Procedimientos Quirúrgicos Vasculares , Anticoagulantes/efectos adversos , Enfermedades de la Aorta/sangre , Enfermedades de la Aorta/mortalidad , COVID-19/sangre , COVID-19/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Humanos , Complicaciones Posoperatorias/etiología , Medición de Riesgo , Factores de Riesgo , Trombofilia/sangre , Trombofilia/mortalidad , Resultado del Tratamiento , Procedimientos Quirúrgicos Vasculares/efectos adversos , Procedimientos Quirúrgicos Vasculares/mortalidad
16.
Ann Vasc Surg ; 72: 383-389, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32890642

RESUMEN

BACKGROUND: Central venous occlusive disease (CVOD) is a prevalent problem in patients with end-stage renal disease (ESRD) and can lead to access malfunction or ligation for symptomatic relief. The purpose of this study is to evaluate the efficacy of the TriForce® Peripheral Crossing Set (Cook Medical), a novel reinforced telescoping catheter set designed to provide additional support for crossing difficult central venous occlusions. METHODS: This is a single-center retrospective study from a quaternary referral center. We identified 37 patients over a 17-month period who underwent 56 attempts at endovascular recanalization for the treatment of central venous occlusion. Technical success rates, procedural data, and outcomes were compared between those undergoing recanalization using traditional wire/catheter sets versus the TriForce catheter set. RESULTS: Average age was 48 ± 2 years. Comorbidities were similar between the two cohorts and included ESRD (61%), deep venous thrombosis (30%), and May-Thurner syndrome (7%). Forty attempts were made with traditional wire/catheter sets and 16 attempts with the TriForce catheter set to treat 2.1 ± 0.2 and 1.9 ± 0.3 occluded venous segments, respectively (P = 0.74). Technical success rates were significantly higher for the group undergoing recanalization using the TriForce catheter (69% versus 38%, P = 0.04) and 4 patients were successfully recanalized using the TriForce catheter set after a failed attempt with traditional wire/catheter sets. Mean fluoroscopy time and radiation dose were 13 ± 3 min and 14,623 ± 2,775 µGy∗m2 for traditional techniques versus 30 ± 6 min and 30,408 ± 10,433 µGy∗m2 for the novel telescoping catheter set (P = 0.01 and 0.09, respectively). Freedom from reintervention at 1 year was 60% for the TriForce cohort versus 44% for the traditional wire/catheter cohort (P = 0.25). CONCLUSIONS: The novel TriForce reinforced telescoping catheter set is a useful adjunct that may improve recanalization rates of CVOD compared with traditional wire/catheter sets.


Asunto(s)
Procedimientos Endovasculares/instrumentación , Dispositivos de Acceso Vascular , Enfermedades Vasculares/terapia , Venas , Obstrucción del Catéter , Cateterismo Venoso Central/efectos adversos , Constricción Patológica , Procedimientos Endovasculares/efectos adversos , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Enfermedades Vasculares/diagnóstico por imagen , Enfermedades Vasculares/etiología , Enfermedades Vasculares/fisiopatología , Grado de Desobstrucción Vascular , Venas/diagnóstico por imagen , Venas/fisiopatología
17.
Am J Cardiol ; 140: 140-147, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-33144163

RESUMEN

Peripheral artery disease (PAD) is associated with impaired lower extremity function. We hypothesized that contrast-enhanced magnetic resonance imaging (CE-MRI) based arterial signal enhancement (SE) measures are associated with markers of PAD. A total of 66 participants were enrolled, 10 were excluded due to incomplete data, resulting in 56 participants for the final analyses (36 PAD, 20 matched controls). MR imaging was performed postreactive hyperemia using bilateral thigh blood-pressure cuffs. First pass-perfusion images were acquired at the mid-calf region with a high-resolution saturation recovery gradient echo pulse sequence, and arterial SE was measured for the lower extremity arteries. As expected, peak walking time (PWT) was reduced in PAD patients compared with controls (282 [248 to 317] sec, vs 353 [346 to 360] sec; p = 0.002), and postexercise ankle brachial index (ABI) decreased in PAD patients but not in controls (PAD: 0.75 ± 0.2, 0.60 [0.5 to 0.7]; p <0.001; vs Controls: 1.17 ± 0.1, 1.19 [1.1 to 1.2]; p = 0.50). Intraclass correlation coefficients were excellent for inter- and intraobserver variability of arterial tracings (n = 10: 0.95 (95%-confidence interval [CI]: 0.94 to 0.96), n = 9: 1.0 (CI: 1.0 to 1.0). Minimum arterial SE was reduced in PAD patients compared with matched controls (128 [110 to 147] A.U. vs 192 [149 to 234] A.U., p = 0.003). Among PAD patients but not in controls the maximum arterial SE was associated with the estimated glomerular filtration rate (eGFR), a marker of renal function (n = 36, ß = 1.37, R2 = 0.12, p = 0.025). In conclusion, CE-MRI first-pass arterial perfusion is impaired in PAD patients compared with matched controls and associated with markers of lower extremity ischemia.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Pierna/irrigación sanguínea , Imagen por Resonancia Magnética/métodos , Enfermedad Arterial Periférica/diagnóstico , Flujo Sanguíneo Regional/fisiología , Caminata/fisiología , Anciano , Índice Tobillo Braquial/métodos , Prueba de Esfuerzo/métodos , Femenino , Humanos , Masculino , Enfermedad Arterial Periférica/fisiopatología , Estudios Retrospectivos
18.
Artículo en Inglés | MEDLINE | ID: mdl-33001164

RESUMEN

OBJECTIVES: Correct stent-graft sizing is important when planning for thoracic endovascular repair in zone 0. As the movements of the aorta are constantly evolving in longitudinal and circumferential directions during the cardiac cycle, the diameter may not be the only important measurement. The aim of this study is to measure the circumferential and longitudinal pulsatile changes throughout the cardiac cycle. METHODS: Ninety-two patients, who were evaluated for transcatheter aortic valve replacement, were selected for this retrospective study. Their electrocardiogram-gated cardiac computed tomography was analysed. We identified the area, perimeter and diameter of the thoracic aorta in zone 0 and calculated the differences between these parameters at 3 locations in zone 0. The measurements were made in multiplanar views perpendicular to the semi-automatically created centreline in both systolic and diastolic phases. RESULTS: The mean age of our study cohort was 77 ± 11 years. The mean change between systole and diastole of the area (mm2), perimeter (mm) and diameter (mm) were compared at 3 different locations in the ascending aorta: at the sinotubular junction (0.78 mm2 vs 0.89 mm vs 1.41 mm), mid-ascending (0.72 mm2 vs 0.68 vs 0.81 mm) and proximal edge of the brachiocephalic artery (0.76 mm2 vs 0.73 mm vs 0.73 mm). The change in percentage is the smallest in the area at the sinotubular junction compared to the perimeter and diameter (2.6% vs 3.1% vs 4.7%). CONCLUSIONS: Changes in measurement of ascending aortic diameter with cardiac cycle are larger than measurement change in the area. This is especially more pronounced in zone 0A. For more accurate information on the morphometric changes, it may be necessary to measure the area when planning for thoracic endovascular repair to maximize results. A prospective study comparing these different measurements regarding the outcomes is advised by the authors to understand the clinical implications.

19.
Vasc Endovascular Surg ; 54(6): 532-535, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32452286

RESUMEN

Ultrasound-guided thrombin injection (UGTI) has emerged as the first-line treatment for moderately sized or persistent pseudoaneurysms (PSAs). Although rare, the most feared complication of UGTI is arterial thrombosis or embolism during the off-label injection of thrombin causing acute limb ischemia requiring emergent surgical intervention. Higher thrombin volume, rapidity of injection, and wide or short-neck PSAs are all thought to increase the risk of arterial thrombosis or embolism during this procedure. For patients with unfavorable PSA anatomy who are high-risk surgical candidates due to their medical comorbidities or active critical illness, balloon-assisted thrombin injection (BATI) has been suggested as a means to potentially reduce the risk of thrombosis or distal embolization associated with UGTI. This minimally invasive technique also decreases the risk of groin wound dehiscence or infection associated with open repair, especially in patients who are morbidly obese or have had prior groin surgery. We report a patient with a complex femoral artery PSA after endovascular intervention who was successfully treated with BATI and describe the procedure in detail.


Asunto(s)
Aneurisma Falso/terapia , Oclusión con Balón , Arteria Femoral/lesiones , Enfermedad Iatrogénica , Trombina/administración & dosificación , Ultrasonografía Intervencional , Lesiones del Sistema Vascular/terapia , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/etiología , Femenino , Arteria Femoral/diagnóstico por imagen , Humanos , Inyecciones Intraarteriales , Persona de Mediana Edad , Resultado del Tratamiento , Lesiones del Sistema Vascular/diagnóstico por imagen , Lesiones del Sistema Vascular/etiología
20.
Eur J Vasc Endovasc Surg ; 60(2): 243-252, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32359973

RESUMEN

OBJECTIVE: To review the existing literature on large animal models of central venous thrombosis (CVT) and to evaluate its relevance in regard to the development and testing of dedicated therapeutics applicable to humans. METHODS: A systematic literature search was conducted in PubMed and Embase. Articles describing an in vivo experimental protocol of CVT in large animals, involving the iliac vein and/or the vena cava and/or the brachiocephalic vein, were included. The primary aim of the study, animal characteristics, experimental protocol, and thrombus evaluation were recorded. RESULTS: Thirty-eight papers describing more than 30 different protocols were included. Animals used were pigs (53%), dogs (21%), monkeys (24%), and cattle (3%). The median number of animals per study was 12. Animal sex, strain, and weight were missing in 18 studies (47%), seven studies (18%), and eight studies (21%), respectively. CVT was always induced by venous stasis: solely (55%), or in addition to hypercoagulability (37%) or endothelial damage (10%). The size of the vessel used for thrombus creation was measured in four studies (10%). Unexpected animal death occurred in nine studies (24%), ranging from 3% to 37% of the animals. Twenty-two studies (58%) in the acute phase and 31 studies in the chronic phase (82%) evaluated the presence or absence of the thrombus created, and its occlusive characteristic was reported, respectively, in five and 17 studies. Histological examination was performed in 24 studies (63%) with comparison to human thrombus in one study. CONCLUSION: This review showed advantages and weaknesses of the existing large animal models of CVT. Future models should insist on more rigour and consistency in reporting animal characteristics, as well as evaluating and comparing the thrombus created to human thrombus.


Asunto(s)
Venas Braquiocefálicas , Vena Ilíaca , Venas Cavas , Trombosis de la Vena , Animales , Coagulación Sanguínea , Venas Braquiocefálicas/patología , Modelos Animales de Enfermedad , Perros , Haplorrinos , Humanos , Vena Ilíaca/patología , Especificidad de la Especie , Sus scrofa , Venas Cavas/patología , Trombosis de la Vena/sangre , Trombosis de la Vena/etiología , Trombosis de la Vena/patología , Trombosis de la Vena/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...