Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Autom Methods Manag Chem ; 2005: 8-25, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-18924721

RESUMEN

MODULAR ANALYTICS (Roche Diagnostics) (MODULAR ANALYTICS, Elecsys and Cobas Integra are trademarks of a member of the Roche Group) represents a new approach to automation for the clinical chemistry laboratory. It consists of a control unit, a core unit with a bidirectional multitrack rack transportation system, and three distinct kinds of analytical modules: an ISE module, a P800 module (44 photometric tests, throughput of up to 800 tests/h), and a D2400 module (16 photometric tests, throughput up to 2400 tests/h). MODULAR ANALYTICS allows customised configurations for various laboratory workloads. The performance and practicability of MODULAR ANALYTICS were evaluated in an international multicentre study at 16 sites. Studies included precision, accuracy, analytical range, carry-over, and workflow assessment. More than 700 000 results were obtained during the course of the study. Median between-day CVs were typically less than 3% for clinical chemistries and less than 6% for homogeneous immunoassays. Median recoveries for nearly all standardised reference materials were within 5% of assigned values. Method comparisons versus current existing routine instrumentation were clinically acceptable in all cases. During the workflow studies, the work from three to four single workstations was transferred to MODULAR ANALYTICS, which offered over 100 possible methods, with reduction in sample splitting, handling errors, and turnaround time. Typical sample processing time on MODULAR ANALYTICS was less than 30 minutes, an improvement from the current laboratory systems. By combining multiple analytic units in flexible ways, MODULAR ANALYTICS met diverse laboratory needs and offered improvement in workflow over current laboratory situations. It increased overall efficiency while maintaining (or improving) quality.

2.
Clin Chem Lab Med ; 40(5): 529-36, 2002 May.
Artículo en Inglés | MEDLINE | ID: mdl-12113300

RESUMEN

Soluble transferrin receptor (sTfR) is reported to be a reliable marker for the diagnosis of iron deficiency, especially when iron metabolism is influenced by inflammatory disorders such as infection, chronic inflammation and cancer-related anemia. In the present multicenter study the analytical performance of a recently introduced, latex-enhanced immunoturbidimetric assay for the determination of soluble transferrin receptor (Tina quant [a] sTfR, Roche Diagnostics) on different fully mechanized analyzers such as Hitachi 917 and 911, and Cobas Integra 400 and 700 was evaluated. Within-run and between-run imprecision showed good results (CV<5% and <7%, respectively). The assay was found to be linear over a wide measuring range (0.4-35 mg/l). Endogenous substances did not interfere with the test results. Comparison of serum sTfR concentrations with those of heparinized plasma revealed good correlation (r>0.976). Method comparison with an existing fully mechanized method as well as with ELISA tests for sTfR showed very good correlation (r>0.987). Because of the lack of international standardization the results differed from each other up to 2.5-fold. The 95% of serum levels in healthy individuals ranged from 1.9 to 4.4 mg/l (n=427). However, the reference ranges should be reported in a sex-dependent manner, as 2.2-5.0 mg/l for men (n=211) and as 1.9-4.4 mg/l for premenopausal (n=216) and postmenopausal (n=45) women. The Tina quant [a] sTfR assay enables the precise, accurate, rapid and convenient determination of sTfR concentrations for routine clinical chemistry purposes.


Asunto(s)
Nefelometría y Turbidimetría/métodos , Receptores de Transferrina/sangre , Adolescente , Adulto , Anciano , Anemia Ferropénica/diagnóstico , Femenino , Pruebas Hematológicas , Humanos , Pruebas de Fijación de Látex/métodos , Pruebas de Fijación de Látex/normas , Masculino , Persona de Mediana Edad , Nefelometría y Turbidimetría/normas , Valores de Referencia , Reproducibilidad de los Resultados , Factores Sexuales , Solubilidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...