Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Am J Ophthalmol Case Rep ; 34: 102009, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38501095

RESUMEN

Purpose: Tube shunts can be inserted into the anterior chamber, ciliary sulcus, or pars plana. Sulcus tube placement can be challenging. This report demonstrates three techniques for guidewire-assisted sulcus tube insertion. Observations: The first technique uses a needle inserted through a paracentesis 180-degrees across from the tube entry site and creates an ab-interno sclerotomy through which the guidewire is inserted by docking it into the needle bevel. The second technique involves inserting the guidewire into the eye via a paracentesis and using microforceps to retrieve it through a sclerotomy. The third technique uses forceps to insert the guidewire into a paracentesis 180° across from the planned tube entry site and dock it into a needle bevel that has been inserted into the sulcus. Each of these techniques provides a reliable and reproducible way to insert a tube into the sulcus. Conclusions and importance: Guidewire-assisted tube entry offers a promising solution in cases of difficult sulcus tube placement without substantial additional cost.

2.
medRxiv ; 2024 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-38260438

RESUMEN

Phospholipase C isozymes (PLCs) hydrolyze phosphatidylinositol 4,5-bisphosphate into inositol 1,4,5-trisphosphate and diacylglycerol, important signaling molecules involved in many cellular processes. PLCG1 encodes the PLCγ1 isozyme that is broadly expressed. Hyperactive somatic mutations of PLCG1 are observed in multiple cancers, but only one germline variant has been reported. Here we describe three unrelated individuals with de novo heterozygous missense variants in PLCG1 (p.Asp1019Gly, p.His380Arg, and p.Asp1165Gly) who exhibit variable phenotypes including hearing loss, ocular pathology and cardiac septal defects. To model these variants in vivo, we generated the analogous variants in the Drosophila ortholog, small wing (sl). We created a null allele slT2A and assessed the expression pattern. sl is broadly expressed, including in wing discs, eye discs, and a subset of neurons and glia. Loss of sl causes wing size reductions, ectopic wing veins and supernumerary photoreceptors. We document that mutant flies exhibit a reduced lifespan and age-dependent locomotor defects. Expressing wild-type sl in slT2A mutant rescues the loss-of-function phenotypes whereas expressing the variants causes lethality. Ubiquitous overexpression of the variants also reduces viability, suggesting that the variants are toxic. Ectopic expression of an established hyperactive PLCG1 variant (p.Asp1165His) in the wing pouch causes severe wing phenotypes, resembling those observed with overexpression of the p.Asp1019Gly or p.Asp1165Gly variants, further arguing that these two are gain-of-function variants. However, the wing phenotypes associated with p.His380Arg overexpression are mild. Our data suggest that the PLCG1 de novo heterozygous missense variants are pathogenic and contribute to the features observed in the probands.

3.
J Ocul Pharmacol Ther ; 39(6): 398-403, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37389843

RESUMEN

Purpose: Sustained intraocular drug delivery devices are being developed to lower intraocular pressure (IOP) and improve adherence in patients with glaucoma. The purpose of this study was to assess the IOP and eyedrop usage reduction effects of intracameral bimatoprost implants. Methods: We retrospectively reviewed the records of 46 eyes from 38 patients who received an intracameral implant containing 10 µg of bimatoprost as a replacement or addition to their existing eyedrop regimen and investigated IOP, eyedrop usage, and adverse effects. Results: Patients were followed for an average of 274 ± 104 (mean ± standard deviation) days after implant. Mean reduction in IOP (mmHg) at 3 months ±30 days, 6 months ±60 days, and 12 months ±90 days postoperation compared to baseline was 1.26 ± 2.53 (P = 0.002), 0.93 ± 4.71 (P = 0.098), and 1.35 ± 5.24 (P = 0.053), respectively. Reduction in eyedrops at 3 months ±30 days, 6 months ±60 days, and 12 months ±90 days postoperation compared to baseline were 0.62 ± 0.49 (P < 0.001), 0.55 ± 0.73 (P < 0.001), and 0.51 ± 0.71 (P < 0.001), respectively. Fifteen eyes (32.6%) experienced implant failure, defined as either restarting IOP-lowering eyedrops or undergoing surgical intervention, at an average of 260 ± 122 days after implant. Conclusions: While some patients eventually experienced implant failure, intracameral bimatoprost implants may result in fewer adverse reactions and successfully lower IOP and eyedrop burden over a longer period than previously reported.


Asunto(s)
Presión Intraocular , Hipertensión Ocular , Humanos , Bimatoprost/farmacología , Soluciones Oftálmicas , Estudios Retrospectivos , Antihipertensivos/farmacología , Amidas , Cloprostenol/efectos adversos , Hipertensión Ocular/tratamiento farmacológico
4.
J Glaucoma ; 32(3): 145-150, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36848258

RESUMEN

PRCIS: The cost of cyclophotocoagulation is less than the cost of a second glaucoma drainage device. PURPOSE: To compare the total direct costs of implantation of a second glaucoma drainage device (SGDD) with transscleral cyclophotocoagulation (CPC) for patients with inadequately controlled intraocular pressure (IOP) reduction, despite the presence of a preexisting glaucoma drainage device in the ASSISTS clinical trial. METHODS: We compared the total direct cost per patient, including the initial study procedure, medications, additional procedures, and clinic visits during the study period. The relative costs for each procedure during the 90-day global period and the entire study period were compared. The cost of the procedure, including facility fees and anesthesia costs, were determined using the 2021 Medicare fee schedule. Average wholesale prices for self-administered medications were obtained from AmerisourceBergen.com. The Wilcoxon rank sum test was used to compare costs between procedures. RESULTS: Forty-two eyes of 42 participants were randomized to SGDD (n=22) or CPC (n=20). One CPC eye was lost to follow-up after initial treatment and was excluded. The mean (±SD, median) duration of follow-up was 17.1 (±12.8, 11.7) months and 20.3 (±11.4, 15.1) months for SGDD and CPC, respectively ( P =0.42, 2 sample t test). The mean total direct costs (±SD, median) per patient during the study period were $8790 (±$3421, $6805 for the SGDD group) and $4090 (±$1424, $3566) for the CPC group ( P <0.001). Similarly, the global period cost was higher in the SGDD group than in the CPC group [$6173 (±$830, $5861) vs. $2569 (±$652, $2628); P <0.001]. The monthly cost after the 90-day global period was $215 (±$314, $100) for SGDD and $103 (±$74, $86) for CPC ( P =0.31). The cost of IOP-lowering medications was not significantly different between groups during the global period ( P =0.19) or after the global period ( P =0.23). CONCLUSION: The total direct cost in the SGDD group was more than double that in the CPC group, driven largely by the cost of the study procedure. The costs of IOP-lowering medications were not significantly different between groups. When considering treatment options for patients with a failed primary GDD, clinicians should be aware of differences in costs between these treatment strategies.


Asunto(s)
Implantes de Drenaje de Glaucoma , Hipotensión Ocular , Estados Unidos , Humanos , Anciano , Medicare , Presión Intraocular , Ojo , Instituciones de Atención Ambulatoria
5.
J Glaucoma ; 31(9): 701-709, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35901309

RESUMEN

PRCIS: Short-term overall success rates were high with either SGDD or CPC. However, SGDD was associated with more clinic visits and an increased risk of additional glaucoma surgery. Both treatments were reasonable options for eyes with inadequately controlled IOP after a single GDD. PURPOSE: The purpose of this study is to compare the implantation of a second glaucoma drainage device (SGDD) and transscleral cyclophotocoagulation (CPC) in eyes with inadequately controlled intraocular pressure (IOP), despite the presence of a preexisting glaucoma drainage device. METHODS: Patients with inadequately controlled IOP, despite the medical therapy and a preexisting glaucoma drainage device, were enrolled at 14 clinical centers and randomly assigned to treatment with a SGDD or CPC. MAIN OUTCOME MEASURES: Surgical failure was defined as: (1) IOP ≤5 mm Hg or >18 mm Hg or <20% reduction below baseline on maximum tolerated topical ocular hypotensive therapy, (2) reoperation for glaucoma, or (3) loss of light perception. The primary outcome measure was overall success with or without adjunctive medical therapy. RESULTS: Forty-two eyes of 42 participants were randomized to SGDD (n=22) or CPC (n=20). Mean duration of follow-up was 18.6 (±12.1; range: 1.1-38.6) months. The cumulative success rate was 79% for SGDD and 88% for CPC at 1 year ( P =0.63). Although the study was underpowered, no significant differences in IOP, postoperative number of IOP-lowering medications, or adverse events were observed. The number of additional glaucoma surgeries ( P =0.003), office visits during the first 3 months ( P <0.001), and office visits per month after month 3 ( P <0.001) were greater in the SGDD group. CONCLUSIONS: Short-term overall success rates were high with either SGDD or CPC. However, SGDD was associated with more clinic visits and an increased risk of additional glaucoma surgery.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma , Cuerpo Ciliar/cirugía , Estudios de Seguimiento , Glaucoma/etiología , Glaucoma/cirugía , Implantes de Drenaje de Glaucoma/efectos adversos , Humanos , Presión Intraocular , Coagulación con Láser , Estudios Retrospectivos , Resultado del Tratamiento
6.
J Neuroophthalmol ; 42(1): e140-e146, 2022 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33870948

RESUMEN

OBJECTIVE: Optic nerve aplasia (ONA) is a rare ocular anomaly. We report ophthalmologic, systemic, and genetic findings in ONA. METHODS: Patients were identified through an International Pediatric Ophthalmology listserv and from the practice of the senior author. Participating Listserv physicians completed a data collection sheet. Children of all ages were included. Neuroimaging findings were also recorded. RESULTS: Nine cases of ONA are reported. Patients' ages ranged from 10 days to 2 years (median 9 months). Seven cases were bilateral. All patients had absence of the optic nerve and retinal vessels in the affected eye or eyes. Ophthalmologic findings included glaucoma, microcornea, persistent pupillary membrane, iris coloboma, aniridia, retinal dysplasia, retinal atrophy, chorioretinal coloboma, and persistent fetal vasculature. Systemic findings included facial dysmorphism, cardiac, genitourinary, skeletal, and developmental defects. A BCOR mutation was found in one patient. One patient had rudimentary optic nerves and chiasm on imaging. CONCLUSION: ONA is a unilateral or bilateral condition that may be associated with anomalies of the anterior or posterior segment with or without systemic findings. Rudimentary optic nerve on neuroimaging in one case suggests that ONA is on the continuum of optic nerve hypoplasia.


Asunto(s)
Coloboma , Enfermedades del Nervio Óptico , Niño , Humanos , Lactante , Neuroimagen , Nervio Óptico/anomalías , Nervio Óptico/diagnóstico por imagen , Vasos Retinianos
8.
Taiwan J Ophthalmol ; 11(3): 296-299, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34703747

RESUMEN

Traumatic cyclodialysis clefts, a rare diagnosis after blunt injury to the eye, are typically amenable to closure with either medical therapy or direct surgical cyclopexy. However, when cyclodialysis clefts cannot be closed through these methods, unorthodox techniques may be required. We describe a method to close a traumatic cyclodialysis cleft involving simultaneous vitrectomy, capsular tension ring placement, and insertion of an intraocular lens.

9.
Pediatr Neurol ; 121: 59-66, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34153815

RESUMEN

BACKGROUND: Sturge-Weber syndrome (SWS) is a sporadic, neurocutaneous syndrome involving the skin, brain, and eyes. Because of the variability of the clinical manifestations and the lack of prospective studies, consensus recommendations for management and treatment of SWS have not been published. OBJECTIVE: This article consolidates the current literature with expert opinion to make recommendations to guide the neuroimaging evaluation and the management of the neurological and ophthalmologic features of SWS. METHODS: Thirteen national peer-recognized experts in neurology, radiology, and ophthalmology with experience treating patients with SWS were assembled. Key topics and questions were formulated for each group and included (1) risk stratification, (2) indications for referral, and (3) optimum treatment strategies. An extensive PubMed search was performed of English language articles published in 2008 to 2018, as well as recent studies identified by the expert panel. The panel made clinical practice recommendations. CONCLUSIONS: Children with a high-risk facial port-wine birthmark (PWB) should be referred to a pediatric neurologist and a pediatric ophthalmologist for baseline evaluation and periodic follow-up. In newborns and infants with a high-risk PWB and no history of seizures or neurological symptoms, routine screening for brain involvement is not recommended, but brain imaging can be performed in select cases. Routine follow-up neuroimaging is not recommended in children with SWS and stable neurocognitive symptoms. The treatment of ophthalmologic complications, such as glaucoma, differs based on the age and clinical presentation of the patient. These recommendations will help facilitate coordinated care for patients with SWS and may improve patient outcomes.


Asunto(s)
Consenso , Guías de Práctica Clínica como Asunto/normas , Síndrome de Sturge-Weber/diagnóstico , Síndrome de Sturge-Weber/terapia , Niño , Preescolar , Congresos como Asunto , Glaucoma/diagnóstico , Glaucoma/etiología , Glaucoma/terapia , Humanos , Lactante , Recién Nacido , Neuroimagen/normas , Neurología/normas , Oftalmología/normas , Mancha Vino de Oporto/diagnóstico , Mancha Vino de Oporto/etiología , Mancha Vino de Oporto/terapia , Convulsiones/diagnóstico , Convulsiones/etiología , Convulsiones/terapia , Síndrome de Sturge-Weber/complicaciones
10.
Am J Med Genet A ; 185(8): 2315-2324, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33949769

RESUMEN

Gillespie syndrome (GLSP) is characterized by bilateral symmetric partial aplasia of the iris presenting as a fixed and large pupil, cerebellar hypoplasia with ataxia, congenital hypotonia, and varying levels of intellectual disability. GLSP is caused by either biallelic or heterozygous, dominant-negative, pathogenic variants in ITPR1. Here, we present a 5-year-old male with GLSP who was found to have a heterozygous, de novo intronic variant in ITPR1 (NM_001168272.1:c.5935-17G > A) through genome sequencing (GS). Sanger sequencing of cDNA from this individual's fibroblasts showed the retention of 15 nucleotides from intron 45, which is predicted to cause an in-frame insertion of five amino acids near the C-terminal transmembrane domain of ITPR1. In addition, qPCR and cDNA sequencing demonstrated reduced expression of both ITPR1 alleles in fibroblasts when compared to parental samples. Given the close proximity of the predicted in-frame amino acid insertion to the site of previously described heterozygous, de novo, dominant-negative, pathogenic variants in GLSP, we predict that this variant also has a dominant-negative effect on ITPR1 channel function. Overall, this is the first report of a de novo intronic variant causing GLSP, which emphasizes the utility of GS and cDNA studies for diagnosing patients with a clinical presentation of GLSP and negative clinical exome sequencing.


Asunto(s)
Aniridia/diagnóstico , Aniridia/genética , Ataxia Cerebelosa/diagnóstico , Ataxia Cerebelosa/genética , Estudios de Asociación Genética , Predisposición Genética a la Enfermedad , Receptores de Inositol 1,4,5-Trifosfato/genética , Discapacidad Intelectual/diagnóstico , Discapacidad Intelectual/genética , Intrones , Mutación , Alelos , Preescolar , Análisis Mutacional de ADN , Facies , Estudios de Asociación Genética/métodos , Humanos , Receptores de Inositol 1,4,5-Trifosfato/química , Imagen por Resonancia Magnética , Masculino , Fenotipo , Evaluación de Síntomas , Secuenciación Completa del Genoma
12.
J Glaucoma ; 29(11): 1036-1042, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32976290

RESUMEN

PRéCIS:: The potential parameters for differentiating pupillary block (PB) from plateau iris configuration (PIC) on anterior segment optical coherence tomography (ASOCT) are lens/pupil size parameters and angles. Further study is needed to determine a landmark peripheral to the centroid of the iris. PURPOSE: Investigate anterior segment parameters to distinguish between 2 mechanisms of angle closure, PB and PIC, using swept-source Fourier domain ASOCT. PATIENTS AND METHODS: Retrospective ASOCT images from narrow angle eyes were reviewed. PIC was defined either by ultrasound biomicroscopy and/or clinically when an iridoplasty was performed. Images were read by a masked reader using Anterior Chamber Analysis and Interpretation software to identify scleral spur landmarks and calculate anterior chamber, peripheral angle, iris size, iris shape, and lens/pupil size parameters. ASOCT parameters were summarized and compared using the 2-sample t test. Thresholds and area under receiver operating characteristic curve were calculated using logistic regression analysis. RESULTS: One hundred eyes (66 PB and 34 PIC) of 100 participants were reviewed. Of all ASOCT parameters, iris length in each quadrant, pupil arc, lens/pupil parameters (pupil arc, lens vault, and pupil diameter), all pupillary margin-center point-scleral spur landmark (PM-C-SSL) parameters, and all except superior central iris vault parameters were significantly different between PB and PIC. On threshold evaluation, lens/pupil parameters had the greatest area under receiver operating characteristic curve values (0.77 to 0.80), followed by PM-C-SSL angles (0.71 to 0.75). CONCLUSIONS: We propose that the pupil size parameters and PM-C-SSL angle are the most reliable novel ASOCT parameters to distinguish between PB and PIC eyes. These parameters do not rely on the visibility of the posterior iris surface, which is difficult to identify with ASOCT, but may be ambient lighting dependent.


Asunto(s)
Segmento Anterior del Ojo/diagnóstico por imagen , Glaucoma de Ángulo Cerrado/diagnóstico por imagen , Enfermedades del Iris/diagnóstico por imagen , Trastornos de la Pupila/diagnóstico por imagen , Tomografía de Coherencia Óptica , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Glaucoma de Ángulo Cerrado/cirugía , Gonioscopía , Humanos , Presión Intraocular , Iridectomía , Masculino , Microscopía Acústica , Persona de Mediana Edad , Curva ROC , Estudios Retrospectivos
13.
Ophthalmology ; 126(1): 156-170, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-29361356

RESUMEN

PURPOSE: To describe the study protocol and baseline characteristics of the African Descent and Glaucoma Evaluation Study (ADAGES) III. DESIGN: Cross-sectional, case-control study. PARTICIPANTS: Three thousand two hundred sixty-six glaucoma patients and control participants without glaucoma of African or European descent were recruited from 5 study centers in different regions of the United States. METHODS: Individuals of African descent (AD) and European descent (ED) with primary open-angle glaucoma (POAG) and control participants completed a detailed demographic and medical history interview. Standardized height, weight, and blood pressure measurements were obtained. Saliva and blood samples to provide serum, plasma, DNA, and RNA were collected for standardized processing. Visual fields, stereoscopic disc photographs, and details of the ophthalmic examination were obtained and transferred to the University of California, San Diego, Data Coordinating Center for standardized processing and quality review. MAIN OUTCOME MEASURES: Participant gender, age, race, body mass index, blood pressure, history of smoking and alcohol use in POAG patients and control participants were described. Ophthalmic measures included intraocular pressure, visual field mean deviation, central corneal thickness, glaucoma medication use, or past glaucoma surgery. Ocular conditions, including diabetic retinopathy, age-related macular degeneration, and past cataract surgery, were recorded. RESULTS: The 3266 ADAGES III study participants in this report include 2146 AD POAG patients, 695 ED POAG patients, 198 AD control participants, and 227 ED control participants. The AD POAG patients and control participants were significantly younger (both, 67.4 years) than ED POAG patients and control participants (73.4 and 70.2 years, respectively). After adjusting for age, AD POAG patients had different phenotypic characteristics compared with ED POAG patients, including higher intraocular pressure, worse visual acuity and visual field mean deviation, and thinner corneas (all P < 0.001). Family history of glaucoma did not differ between AD and ED POAG patients. CONCLUSIONS: With its large sample size, extensive specimen collection, and deep phenotyping of AD and ED glaucoma patients and control participants from different regions in the United States, the ADAGES III genomics study will address gaps in our knowledge of the genetics of POAG in this high-risk population.


Asunto(s)
Negro o Afroamericano/genética , Glaucoma de Ángulo Abierto/genética , Polimorfismo de Nucleótido Simple , Anciano , Constitución Corporal , Estudios de Casos y Controles , Estudios Transversales , Femenino , Interacción Gen-Ambiente , Estudio de Asociación del Genoma Completo , Genotipo , Glaucoma de Ángulo Abierto/diagnóstico , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Fenotipo , Proyectos de Investigación , Agudeza Visual/fisiología , Campos Visuales/fisiología , Población Blanca/genética
14.
Ophthalmology ; 126(1): 38-48, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30352225

RESUMEN

PURPOSE: To find genetic contributions to glaucoma in African Americans. DESIGN: Cross-sectional, case-control study. PARTICIPANTS: One thousand eight hundred seventy-five primary open-angle glaucoma (POAG) patients and 1709 controls, self-identified as being of African descent (AD), from the African Descent and Glaucoma Evaluation Study (ADAGES) III and Wake Forest School of Medicine. METHODS: MegaChip genotypes were imputed to Thousand Genomes data. Association of single nucleotide polymorphisms (SNPs) with POAG and advanced POAG was tested by linear mixed model correcting for relatedness and population stratification. Genetic risk scores were tested by receiver operator characteristic curves (ROC-AUCs). MAIN OUTCOME MEASURES: Primary open-angle glaucoma defined by visual field loss without other nonocular conditions (n = 1875). Advanced POAG was defined by age-based mean deviation of visual field (n = 946). RESULTS: Eighteen million two hundred eighty-one thousand nine hundred twenty SNPs met imputation quality of r2 > 0.7 and minor allele frequency > 0.005. Association of a novel locus, EN04, was observed for advanced POAG (rs185815146 ß, 0.36; standard error, 0.065; P < 3×10-8). For POAG, an AD signal was observed at the 9p21 European descent (ED) POAG signal (rs79721419; P < 6.5×10-5) independent of the previously observed 9p21 ED signal (rs2383204; P < 2.3×10-5) by conditional analyses. An association with POAG in FNDC3B (rs111698934; P < 3.9×10-5) was observed, not in linkage disequilibrium (LD) with the previously reported ED SNP. Additional previously identified loci associated with POAG in persons of AD were: 8q22, AFAP1, and TMC01. An AUC of 0.62 was observed with an unweighted genetic risk score comprising 11 SNPs in candidate genes. Two additional risk scores were studied by using a penalized matrix decomposition with cross-validation; risk scores of 50 and 400 SNPs were identified with ROC of AUC = 0.74 and AUC = 0.94, respectively. CONCLUSIONS: A novel association with advanced POAG in the EN04 locus was identified putatively in persons of AD. In addition to this finding, this genome-wide association study in POAG patients of AD contributes to POAG genetics by identification of novel signals in prior loci (9p21), as well as advancing the fine mapping of regions because of shorter average LD (FNDC3B). Although not useful without confirmation and clinical trials, the use of genetic risk scores demonstrated that considerable AD-specific genetic information remains in these data.


Asunto(s)
Negro o Afroamericano/genética , Glaucoma de Ángulo Abierto/genética , Fosfopiruvato Hidratasa/genética , Polimorfismo de Nucleótido Simple , Anciano , Estudios de Casos y Controles , Estudios Transversales , Femenino , Frecuencia de los Genes , Predisposición Genética a la Enfermedad , Estudio de Asociación del Genoma Completo , Genotipo , Glaucoma de Ángulo Abierto/diagnóstico , Humanos , Presión Intraocular , Masculino , Persona de Mediana Edad , Curva ROC
16.
Ophthalmology ; 125(7): 994-1002, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29477691

RESUMEN

PURPOSE: To identify the presence or absence of 3 identifiable landmarks: trabecular meshwork (TM), Schlemm's canal (SC), and a novel landmark termed the band of extracanalicular limbal lamina (BELL), which is a landmark adjacent to SC visible on anterior segment (AS) OCT. These landmarks also were analyzed pathologically to identify all 3 landmarks. DESIGN: Retrospective review. PARTICIPANTS: One eye per participant from prior institutional review board-approved studies in which AS OCT imaging was performed. METHODS: Horizontal images from 2-dimensional angle analysis scans using a CASIA SS-1000 (Tomey, Nagoya, Japan) AS OCT were evaluated by masked readers. Logistic regression was used to analyze the potential factors of age, gender, race, intraocular pressure, gonioscopy grade, angle location, and history or presence of surgery on the visibility of these structures. Pathologic correlation on 5 previously enucleated eyes also was performed. MAIN OUTCOME MEASURES: Presence or absence of angle landmarks-TM, SC, and BELL-using Anterior Chamber Analysis and Interpretation software (ACAI, Houston, TX). RESULTS: Three hundred three angles of 153 horizontal images were included in this study. The mean age was 51.5±16.0 years, with 98 women (64%) and 100 white persons (66%). The outer border of the BELL was observed in 288 angles (95%), TM was found in 220 angles (73%), and SC was seen in 120 angles (40%). The outer border of the BELL was more visible in white persons (P = 0.02) than Asians and in eyes with a Spaeth gonioscopy grade of E than those with a grade of A (P = 0.02). Both TM (P = 0.001) and SC (P = 0.001) were more visible in temporal angles (81% for TM, 49% for SC) than in nasal angles (64% for TM, 30% for SC). Additionally, SC was more visible in open angles (43%) than in narrow angles (27%; P = 0.02). These 3 structures were verified in a pathologic study. CONCLUSIONS: We identified a novel AS OCT landmark adjacent to SC. This structure also was identified on pathologic samples from enucleated eyes. Further study is needed to determine the pathophysiologic relevance of these findings.


Asunto(s)
Puntos Anatómicos de Referencia/diagnóstico por imagen , Limbo de la Córnea/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Malla Trabecular/diagnóstico por imagen , Anciano , Segmento Anterior del Ojo/diagnóstico por imagen , Femenino , Gonioscopía , Humanos , Presión Intraocular , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tonometría Ocular
17.
J Glaucoma ; 26(11): 1010-1018, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28858156

RESUMEN

PURPOSE: Compare intraocular pressure (IOP) control and complication rates of a second glaucoma drainage device (GDD) to diode transscleral cyclophotocoagulation (TSCPC) following failure of an initial GDD. PATIENTS AND METHODS: Eyes with 1 GDD that required a second GDD or TSCPC for glaucoma control were included. Exclusion criteria were a cyclodestructive procedure before initial GDD, no light perception vision, or follow-up <1 year. Failure was defined as ≥1 of (1) reoperation for lowering IOP; (2) explantation of second GDD; (3) persistent hypotony; (4) use of oral carbonic anhydrase inhibitor for lowering IOP in the study eye; or (5) loss of light perception. Reoperation for lowering IOP included additional GDD implantation or additional cyclodestruction, except if additional cyclodestruction was within 6 months of the initial session. RESULTS: A total of 75 eyes (35 in second GDD; 40 in TSCPC) were included (mean follow-up, 25.5 mo). Both procedures lowered IOP [-11.4 mm Hg (±13.6) for second GDD and -7.8 mm Hg (±11.8) for TSCPC groups] and decreased the number of IOP-lowering medications at the last visit. The second GDD group had significantly greater mean survival time [45.0 mo (±4.2)] than the TSCPC group [26.5 mo (±2.8)] but significantly more postoperative complications (60% of eyes) and non-IOP-related procedures (40% of eyes) than the TSCPC group (20% for postoperative complications and 18% for non-IOP-related procedures). CONCLUSIONS: Although both second procedures are efficacious in lowering IOP and number of IOP-lowering medications, TSCPC failed earlier, whereas a second GDD had significantly more complications.


Asunto(s)
Cuerpo Ciliar/cirugía , Implantes de Drenaje de Glaucoma , Glaucoma/cirugía , Coagulación con Láser , Complicaciones Posoperatorias , Falla de Prótesis , Adulto , Anciano , Inhibidores de Anhidrasa Carbónica , Femenino , Glaucoma/fisiopatología , Humanos , Presión Intraocular/fisiología , Láseres de Semiconductores/uso terapéutico , Masculino , Persona de Mediana Edad , Reoperación , Estudios Retrospectivos , Tonometría Ocular , Resultado del Tratamiento , Agudeza Visual/fisiología
18.
J Glaucoma ; 26(9): 780-786, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28767461

RESUMEN

PURPOSE: To report long-term (>5 y) outcomes of plateau iris syndrome patients treated with argon laser peripheral iridoplasty (ALPI). PATIENTS AND METHODS: A retrospective chart review was performed on all patients with plateau iris syndrome treated with ALPI from 1996 to 2007. The study included 22 eyes from 22 patients with plateau iris after peripheral iridotomy that were followed for at least 1 year after ALPI. The primary outcome was incidence of needing any intraocular pressure (IOP)-lowering medications or surgery (either a filtering procedure or phacoemulsification). Demographic and baseline clinical data were summarized by mean (±SD) or frequency (percentage). Snellen best-corrected visual acuity was converted to logMAR. The paired t test was used to compare IOP changes, number of IOP-lowering medications, and best-corrected visual acuity from baseline to annual follow-up. RESULTS: Mean follow-up was 76 months. Only 2 (9%) eyes maintained an IOP<21 mm Hg without requiring medication or surgery. Seventeen (77%) eyes underwent surgery at an average of 49.1±7.9 months after ALPI. Eight (36%) eyes underwent filtering surgery, and 9 (41%) eyes underwent phacoemulsification. Three months after cataract extraction, no eyes required IOP-lowering medication. CONCLUSIONS: The beneficial effects of ALPI last for <4 years, with the majority of patients (77%) requiring surgery. Phacoemulsification alone was a successful treatment for plateau iris in our patient population.


Asunto(s)
Glaucoma de Ángulo Cerrado/cirugía , Enfermedades del Iris/cirugía , Iris/cirugía , Terapia por Láser/métodos , Adulto , Anciano , Coagulación con Plasma de Argón , Femenino , Estudios de Seguimiento , Humanos , Presión Intraocular/fisiología , Implantación de Lentes Intraoculares , Masculino , Persona de Mediana Edad , Facoemulsificación , Estudios Retrospectivos , Tonometría Ocular , Agudeza Visual/fisiología
20.
Acad Emerg Med ; 24(9): 1072-1079, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28662312

RESUMEN

OBJECTIVE: The objective was to evaluate the sensitivity and specificity of computed tomography (CT) diagnosis of open globes, determine which imaging factors are most predictive of open globe injuries, and evaluate the agreement between neuroradiologist and ophthalmologist readers for diagnosis of open and closed globes. METHODS: This study was a retrospective cohort study. Patients who presented to Memorial Hermann-Texas Medical Center with suspicion for open globes were reviewed. One neuroradiologist and two ophthalmologists masked to clinical information reviewed CT images for signs concerning for open globe including change in globe contour, anterior chamber deformation, intraocular air, vitreous hemorrhage, subretinal fluid indicating retinal or choroidal detachment, dislocated or absent lens, intraocular foreign body, and orbital fracture. Using the clinically or surgically confirmed globe status as the true globe status, sensitivity, specificity, and agreement (kappa) were calculated and used to investigate which imaging factors are most predictive of open globe injuries. RESULTS: A total of 114 patients were included: 35 patients with open globes and 79 patients with closed globes. Specificity was greater than 97% for each reader, and sensitivity ranged from 51% to 77% among readers. The imaging characteristics most consistently used to predict an open globe injury were change in globe contour and vitreous hemorrhage (sensitivity = 43% to 57%, specificity > 98%). The agreement of impression of open globe between the neuroradiologist and ophthalmologists was good and excellent between ophthalmologists. CONCLUSIONS: Computed tomography imaging is not absolute, and the sensitivity is still inadequate to be fully relied upon. The CT imaging findings most predictive of an open globe injury were change in globe contour and vitreous hemorrhage. Clinical examination or surgical exploration remains the most important component in evaluating for a suspected open globe, with CT imaging as an adjunct.


Asunto(s)
Lesiones Oculares Penetrantes/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Lesiones Oculares Penetrantes/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oftalmólogos/estadística & datos numéricos , Radiólogos/estadística & datos numéricos , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...