Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
BMC Med Inform Decis Mak ; 24(1): 44, 2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38347499

RESUMEN

BACKGROUND: Physical inactivity and a sedentary lifestyle are common among people with heart failure (HF), which may lead to worse prognosis. On an already existing mHealth platform, we developed a novel tool called the Activity coach, aimed at increasing physical activity. The aim of this study was to evaluate the usability of the Activity coach and assess feasibility of outcome measures for a future efficacy trial. METHODS: A mixed-methods design was used to collect data. People with a HF diagnosis were recruited to use the Activity coach for four weeks. The Activity coach educates the user about physical activity, provides means of registering daily physical activity and helps the user to set goals for the next week. The usability was assessed by analysing system user logs for adherence, reported technical issues and by interviews about user experiences. Outcome measures assessed for feasibility were objective physical activity as measured by an accelerometer, and subjective goal attainment. Progression criteria for the usability assessment and for the proposed outcomes, were described prospectively. RESULTS: Ten people with HF were recruited, aged 56 to 78 with median age 72. Data from nine of the ten study participants were included in the analyses. Usability: The Activity coach was used 61% of the time and during the first week two study participants called to seek technical support. The Activity coach was found to be intuitive and easy to use by all study participants. An increased motivation to be more physically active was reported by six of the nine study participants. However, in spite of feeling motivated, four reported that their habits or behaviours had not been affected by the Activity coach. FEASIBILITY: Data was successfully stored in the deployed hardware as intended and the accelerometers were used enough, for the data to be analysable. One finding was that the subjective outcome goal attainment, was challenging to collect. A proposed mitigator for this is to use pre-defined goals in future studies, as opposed to having the study participants be completely free to formulate the goals themselves. CONCLUSIONS: It was confirmed that the Activity coach was easy to use. Furthermore, it might stimulate increased physical activity in a population of people with HF, who are physically inactive. The outcomes investigated seem feasible to include in a future efficacy trial. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT05235763. Date of first registration: 11/02/2022.


Asunto(s)
Insuficiencia Cardíaca , Telemedicina , Humanos , Anciano , Estudios de Factibilidad , Interfaz Usuario-Computador , Ejercicio Físico , Insuficiencia Cardíaca/terapia , Telemedicina/métodos
2.
ESC Heart Fail ; 7(4): 1467-1476, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32372549

RESUMEN

AIM: The purpose of this study was to explore the utility of two single-item self-report (SR) questions to assess physical inactivity in patients with heart failure (HF). METHODS AND RESULTS: This is a cross-sectional study using data from 106 patients with HF equipped with accelerometers for 1 week each. Two SR items relating to physical activity were also collected. Correlations between accelerometer activity counts and the SR items were analysed. Patients were classified as physically active or inactive on the basis of accelerometer counts, and the SR items were used to try to predict that classification. Finally, patients were classified as having high self-reported physical activity or low self-reported physical activity, on the basis of the SR items, and the resulting groups were analysed for differences in actual physical activity. There were significant but weak correlations between the SR items and accelerometer counts: ρ = 0.24, P = 0.016 for SR1 and ρ = 0.21, P = 0.033 for SR2. Using SR items to predict whether a patient was physically active or inactive produced an area under the curve of 0.62 for SR1, with a specificity of 92% and a sensitivity of 30%. When dividing patients into groups on the basis of SR1, there was a significant difference of 1583 steps per day, or 49% more steps in the high self-reported physical activity group (P < 0.001). CONCLUSIONS: There might be utility in the single SR question for high-specificity screening of large populations to identify physically inactive patients in order to assign therapeutic interventions efficiently where resources are limited.


Asunto(s)
Insuficiencia Cardíaca , Conducta Sedentaria , Enfermedad Crónica , Estudios Transversales , Ejercicio Físico , Insuficiencia Cardíaca/diagnóstico , Humanos
3.
J Chem Phys ; 148(24): 244503, 2018 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-29960348

RESUMEN

Self- and impurity diffusion coefficients are assessed in the liquid nickel system by the fundamental ab initio molecular dynamics approach. The impurity diffusion coefficients in the Ni-X systems (X=C, Co, N, Nb, Ta, Ti, W) are mostly not available in the current literature. The simulations are performed at four temperatures, in the range from 1903 to 2303 K, which allows to extract activation energies and frequency factors for the temperature dependent diffusion coefficient assuming an Arrhenius-type behavior in the liquid. In addition to the temperature dependence, the concentration-dependent impurity diffusion was investigated for the Ni-Co system. The data are of relevance for the development of the state-of-the art Ni-based superalloys and alternative binder systems in cemented carbides. The obtained theoretical results are in very good agreement with the limited experimental data for the diffusion in liquid Ni systems.

4.
Materials (Basel) ; 10(1)2017 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-28772417

RESUMEN

(Ti,Zr)C powder was sintered with WC-Co following an industrial process, including an isotherm at 1410 °C. A series of interrupted sintering trials was performed with the aim of studying the sintering behavior and the microstructural evolution during both solid-state and liquid-state sintering. Reference samples, using the same elemental compositions but with the starting components TiC and ZrC instead of (Ti,Zr)C, were also sintered. The microstructure was investigated using scanning electron microscopy and energy dispersive X-ray spectroscopy. It is found that the (Ti,Zr)C phase decomposes into Ti-rich and Zr-rich nano-scale lamellae before the liquid-state of the sintering initiates. The final microstructure consists of the binder and WC as well as two different γ phases, rich in either Ti (γ1) or Zr (γ2). The γ2 phase grains have a core-shell structure with a (Ti,Zr)C core following the full sintering cycle. The major differences observed in (Ti,Zr)C with respect to the reference samples after the full sintering cycle were the referred core-shell structure and the carbide grain sizes; additionally, the microstructural evolution during sintering differs. The grain size of carbides (WC, γ1, and γ2) is about 10% smaller in WC-(Ti,Zr)C-Co than WC-TiC-ZrC-Co. The shrinkage behavior and hardness of both composites are reported and discussed.

5.
Sci Rep ; 4: 4686, 2014 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-24732685

RESUMEN

We report an unusual robust ferromagnetic order above room temperature upon amorphization of perovskite [YCrO3] in pulsed laser deposited thin films. This is contrary to the usual expected formation of a spin glass magnetic state in the resulting disordered structure. To understand the underlying physics of this phenomenon, we combine advanced spectroscopic techniques and first-principles calculations. We find that the observed order-disorder transformation is accompanied by an insulator-metal transition arising from a wide distribution of Cr-O-Cr bond angles and the consequent metallization through free carriers. Similar results also found in YbCrO3-films suggest that the observed phenomenon is more general and should, in principle, apply to a wider range of oxide systems. The ability to tailor ferromagnetic order above room temperature in oxide materials opens up many possibilities for novel technological applications of this counter intuitive effect.

6.
Pacing Clin Electrophysiol ; 37(7): 810-9, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24502608

RESUMEN

BACKGROUND: We hypothesized that left atrial pressure (LAP) obtained by a permanent implantable sensor is sensitive to changes in cardiac resynchronization therapy (CRT) settings and could guide CRT optimization to improve the response rate. We investigated the effect of CRT optimization on LAP and its waveform parameters in ambulant heart failure (HF) patients. METHODS: CRT optimization was performed in eight ambulant HF patients, using echocardiography as reference. LAP waveform was acquired at each of eight atrioventricular (AV) intervals and five inter-ventricular (VV) intervals. Selected waveform parameters were also evaluated for their sensitivity to CRT changes and agreement with echocardiography-guided optimal settings. RESULTS: Optimal AV and VV intervals varied considerably between patients. All patients exhibited significant changes in waveform morphology with AV optimization. Optimal AV delay determined from echocardiography ranged between 140 ms and 225 ms. Mean LAP tended to be lower at optimal setting 14 ± 3 mmHg compared to shorter (<100 ms) or longer (>160 ms) AV settings (P = 0.16). There were clear trends to smaller peak a-wave (P = 0.11) and gentler positive a-slope (P = 0.15) and positive v-slope (P = 0.09) with longer AV delays. Mean LAP and negative v-wave slope correlated well with echo-guided optimal setting, r = 0.91 (P = 0.001) and 0.79 (P = 0.03), respectively. No significant effects on LAP or waveform were seen during VV optimization. CONCLUSIONS: LAP and its waveform changes considerably with AV optimization. There is good agreement between echo-guided optimal setting and LAP. LAP could provide an objective guide to CRT optimization. (Clinical Trial Registry information: URL: http://www.clinicaltrials.gov. Unique Identifier: NCT00632372).


Asunto(s)
Presión Atrial , Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Adulto , Anciano , Estudios de Factibilidad , Humanos , Persona de Mediana Edad , Estudios Prospectivos
7.
Dalton Trans ; 41(16): 4754-64, 2012 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-22258117

RESUMEN

Li-Na ternary amidoborane, Na[Li(NH(2)BH(3))(2)], was recently synthesized by reacting LiH and NaH with NH(3)BH(3). This mixed-cation amidoborane shows improved dehydrogenation performance compared to that of single-cation amidoboranes, i.e., LiNH(2)BH(3) and NaNH(2)BH(3). In this paper, we synthesized the Li-Na ternary amidoborane by blending and re-crystallizing equivalent LiNH(2)BH(3) and NaNH(2)BH(3) in tetrahydrofuran (THF), and employed first-principles calculations and the special quasirandom structure (SQS) method to theoretically explore the likelihood for the existence of Li(1-x)Na(x)(NH(2)BH(3)) for various Li/Na ratios. The thermodynamic, electronic and phononic properties were investigated to understand the possible dehydrogenation mechanisms of Na[Li(NH(2)BH(3))(2)].

8.
Nanotechnology ; 22(33): 335401, 2011 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-21788688

RESUMEN

Complex light metal hydrides possess many properties which make them attractive as a storage medium for hydrogen, but typically catalysts are required to lower the hydrogen desorption temperature and to facilitate hydrogen uptake in the form of a reversible reaction. The overwhelming focus in the search for catalysing agents has been on compounds containing titanium, but the precise mechanism of their actions remains somewhat obscure. A recent experiment has now shown that fullerenes (C(60)) can also act as catalysts for both hydrogen uptake and release in lithium borohydride (LiBH(4)). In an effort to understand the involved mechanism, we have employed density functional theory to carry out a detailed study of the interaction between this complex metal hydride and the carbon nanomaterial. Considering a stepwise reduction of the hydrogen content in LiBH(4), we find that the presence of C(60) can lead to a substantial reduction of the involved H-removal energies. This effect is explained as a consequence of the interaction between the BH(x)( - ) complex and the C(60) entity.

9.
Phys Rev Lett ; 106(1): 018301, 2011 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-21231773

RESUMEN

The energies of the solid reactants in the lead-acid battery are calculated ab initio using two different basis sets at nonrelativistic, scalar-relativistic, and fully relativistic levels, and using several exchange-correlation potentials. The average calculated standard voltage is 2.13 V, compared with the experimental value of 2.11 V. All calculations agree in that 1.7-1.8 V of this standard voltage arise from relativistic effects, mainly from PbO2 but also from PbSO4.

10.
Phys Rev Lett ; 105(18): 185901, 2010 Oct 29.
Artículo en Inglés | MEDLINE | ID: mdl-21231116

RESUMEN

The diffusion rate of hydrogen in Nb was calculated using ab initio molecular dynamics simulations. At low temperatures the hydrogen is strongly trapped in a local strain field which is caused by the elastic response of the lattice. At elevated temperatures, the residence time (τ) of hydrogen in an interstitial site is not sufficient for fully developing the local strain field. This unbinding of the interstitial hydrogen and the strain field increases the hopping rate (1/τ) at elevated temperatures (>400 K). These results call for a revision of the conceptual framework of diffusion of hydrogen in transition metals at elevated temperatures.

12.
Nano Lett ; 9(4): 1501-5, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19351192

RESUMEN

A synergistic approach involving experiment and first-principles theory not only shows that carbon nanostructures can be used as catalysts for hydrogen uptake and release in complex metal hydrides such as sodium alanate, NaAlH(4), but also provides an unambiguous understanding of how the catalysts work. Here we show that the stability of NaAlH(4) originates with the charge transfer from Na to the AlH(4) moiety, resulting in an ionic bond between Na(+) and AlH(4)(-) and a covalent bond between Al and H. Interaction of NaAlH(4) with an electronegative substrate such as carbon fullerene or nanotube affects the ability of Na to donate its charge to AlH(4), consequently weakening the Al-H bond and causing hydrogen to desorb at lower temperatures as well as facilitating the absorption of H(2) to reverse the dehydrogenation reaction. In addition, based on our experimental observations and theoretical calculations it appears the curvature of the carbon nanostructure plays a role in the catalytic process. Ab initio molecular dynamics simulation further reveals the time evolution of the charge transfer process.

13.
J Am Coll Cardiol ; 53(12): 1075-81, 2009 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-19298923

RESUMEN

OBJECTIVES: This study was designed to investigate the properties of multiple bioelectric impedance signals recorded during congestive heart failure (CHF) by utilizing various electrode configurations of an implanted cardiac resynchronization therapy system. BACKGROUND: The monitoring of CHF has relied mainly on right-side heart sensors. METHODS: Fifteen normal dogs underwent implantation of cardiac resynchronization therapy systems using standard leads. An additional left atrial (LA) pressure lead sensor was implanted in 5 dogs. Continuous rapid right ventricular (RV) pacing was applied over several weeks. Left ventricular (LV) catheterization and echocardiography were performed biweekly. Six steady-state impedance signals, utilizing intrathoracic and intracardiac vectors, were measured through ring (r), coil (c), and device Can electrodes. RESULTS: Congestive heart failure developed in all animals after 2 to 4 weeks of pacing. Impedance diminished gradually during CHF induction, but at varying rates for different vectors. Impedance during CHF decreased significantly in all measured vectors: LV(r)-Can, -17%; LV(r)-RV(r), -15%; LV(r)-RA(r), -11%; RV(r)-Can, -12%; RV(c)-Can, -7%; and RA(r)-Can, -5%. The LV(r)-Can vector reflected both the fastest and largest change in impedance in comparison with vectors employing only right-side heart electrodes, and was highly reflective of changes in LV end-diastolic volume and LA pressure. CONCLUSIONS: Impedance, acquired by different lead electrodes, has variable responses to CHF. Impedance vectors employing an LV lead are highly responsive to physiologic changes during CHF. Measuring multiple impedance signals could be useful for optimizing ambulatory monitoring in heart failure patients.


Asunto(s)
Insuficiencia Cardíaca/diagnóstico , Monitoreo Ambulatorio , Animales , Modelos Animales de Enfermedad , Perros , Impedancia Eléctrica , Electrodos Implantados , Insuficiencia Cardíaca/fisiopatología , Hemodinámica , Marcapaso Artificial , Función Ventricular Derecha
14.
Phys Rev Lett ; 102(7): 075504, 2009 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-19257687

RESUMEN

On the basis of ab initio molecular dynamics simulations, large voids mainly surrounded by Te atoms are observed in molten and amorphous Ge2Sb2Te5, which is due to the clustering of two- and threefold coordinated Te atoms. Furthermore, pressure shows a significant effect on the clustering of the under coordinated Te atoms and hence the formation of large voids. The present results demonstrate that both vacancies and Te play an important role in the fast reversible phase transition process.

15.
Proc Natl Acad Sci U S A ; 106(8): 2515-8, 2009 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-19188608

RESUMEN

The formation of substitutional alloys has been restricted to elements with similar atomic radii and electronegativity. Using high-pressure at 298 K, we synthesized a face-centered cubic disordered alloy of highly dissimilar elements (large Ce and small Al atoms) by compressing the Ce(3)Al intermetallic compound >15 GPa or the Ce(3)Al metallic glass >25 GPa. Synchrotron X-ray diffraction, Ce L(3)-edge absorption spectroscopy, and ab initio calculations revealed that the pressure-induced Kondo volume collapse and 4f electron delocalization of Ce reduced the differences between Ce and Al and brought them within the Hume-Rothery (HR) limit for substitutional alloying. The alloy remained after complete release of pressure, which was also accompanied by the transformation of Ce back to its ambient 4f electron localized state and reversal of the Kondo volume collapse, resulting in a non-HR alloy at ambient conditions.

16.
J Chem Phys ; 129(16): 164104, 2008 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-19045244

RESUMEN

Hydrogen binding energies for the primary and secondary adsorption sites in the Cd- and Zn-based metal organic framework-5 (MOF-5) were studied using density functional theory. Out of the three exchange-correlation functionals employed in our study, we find that the local density approximation yields a qualitatively correct description of the interaction strengths of H(2) in MOF-5 systems. The H(2) adsorption energies for all trapping sites in Zn- and Cd-based MOF-5 are seen to be of the same order of magnitude but with a generally stronger binding in Cd-based MOF-5 as compared to Zn-based MOF-5. In particular, the H(2) binding energy at the secondary adsorption sites in Cd-based MOF-5 is increased by around 25% compared to Zn-based MOF-5. This result suggests that Cd-based MOF-5 would be better suited to store hydrogen at higher temperatures than Zn-based MOF-5.

17.
Artículo en Inglés | MEDLINE | ID: mdl-19164003

RESUMEN

INTRODUCTION: We investigated trends in intrathoracic impedance measured between multiple implanted electrodes for monitoring pulmonary edema secondary to congestive heart failure (CHF) in an experimental model. METHODS: Biventricular ICDs were implanted in 16 dogs and 5 sheep. Continuous RV pacing (230- 250 bpm) was applied over several weeks. Meanwhile, impedance was measured every hour along 4 intrathoracic and 2 intracardiac vectors. Four cardiogenic impedance vectors were also monitored. Cardiac function was assessed biweekly by catheterization and echocardiography. Left atrial (LA) pressure was measured daily by an implanted LA pressure sensor. RESULTS: All animals developed CHF after 2-4 weeks of pacing as evidenced by changes in function (EF, 52 vs. 34%; LV end-diastolic volume, 65 vs. 97 ml; LV end-diastolic pressure, 7 vs. 16 mmHg; LA volume, 17 vs. 33 ml; LA pressure, 7 vs. 26 mmHg), clinical symptoms, or autopsy. Steady state impedance decreased during CHF: LV-Can, 17+/-9%; LV-RV, 15+/-8%; LV-RA, 13+/-6%; RV-Can, 13+/-8%; RVcoil-Can, 8+/-6%; RA-Can, 6+/-6%. Change in LV-Can impedance was greater than that of RA-Can, RV-Can, and RVcoil-Can (P0.05). LV-Can impedance correlated well with LA pressure (r(2)=0.73), while RV-Can and RVcoil-Can were weakly correlated (r(2)=0.43 and r(2)=0.52, respectively). Changes in LV-RV and LV-RA impedances were also larger than those of RVcoil-Can and RA-Can (P0.05). Meanwhile, all impedances were associated with circadian variability at baseline (5+/-2%) which diminished during CHF (2+/-1%); P=0.02. Furthermore, significant variations were observed in cardiogenic impedances during progression into CHF as evidenced by reduced peak-to-peak amplitude and increased fractionation of the signals. CONCLUSIONS: All impedance vectors decreased during CHF. Impedance measurement employing left heart sensors correlated well wit- - h LA pressure, and may improve detection of CHF onset compared to sensing by RA or RV leads alone. This approach has important clinical implications for managing heart failure patients in the ambulatory setting.


Asunto(s)
Algoritmos , Diagnóstico por Computador/métodos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/etiología , Pletismografía de Impedancia/métodos , Edema Pulmonar/diagnóstico , Edema Pulmonar/etiología , Animales , Perros , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Ovinos
18.
J Phys Condens Matter ; 20(20): 205102, 2008 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-21694283

RESUMEN

Phase-change materials based on chalcogenide alloys have been widely used for optical data storage and are promising materials for nonvolatile electrical memory use. However, the mechanism behind the utilization is unclear as yet. Since the rewritable data storage involved an extremely fast laser melt-quenched process for chalcogenide alloys, the liquid structure of which is one key to investigating the mechanism of the fast reversible phase transition and hence rewritable data storage, here by means of ab initio molecular dynamics we have studied the local structure of liquid Ge(1)Sb(2)Te(4). The results show that the liquid structure gives a picture of most Sb atoms being octahedrally coordinated, and the coexistence of tetrahedral and fivefold coordination at octahedral sites for Ge atoms, while Te atoms are essentially fourfold and threefold coordinated at octahedral sites, as characterized by partial pair correlation functions and bond angle distributions. The local structure of liquid Ge(1)Sb(2)Te(4) generally resembles that of the crystalline form, except for the much lower coordination number. It may be this unique liquid structure that results in the fast and reversible phase transition between crystalline and amorphous states.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...