Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
ESC Heart Fail ; 8(6): 5531-5541, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34480422

RESUMEN

AIMS: The HERMES (HEart failure Molecular Epidemiology for Therapeutic targetS) consortium aims to identify the genomic and molecular basis of heart failure. METHODS AND RESULTS: The consortium currently includes 51 studies from 11 countries, including 68 157 heart failure cases and 949 888 controls, with data on heart failure events and prognosis. All studies collected biological samples and performed genome-wide genotyping of common genetic variants. The enrolment of subjects into participating studies ranged from 1948 to the present day, and the median follow-up following heart failure diagnosis ranged from 2 to 116 months. Forty-nine of 51 individual studies enrolled participants of both sexes; in these studies, participants with heart failure were predominantly male (34-90%). The mean age at diagnosis or ascertainment across all studies ranged from 54 to 84 years. Based on the aggregate sample, we estimated 80% power to genetic variant associations with risk of heart failure with an odds ratio of ≥1.10 for common variants (allele frequency ≥ 0.05) and ≥1.20 for low-frequency variants (allele frequency 0.01-0.05) at P < 5 × 10-8 under an additive genetic model. CONCLUSIONS: HERMES is a global collaboration aiming to (i) identify the genetic determinants of heart failure; (ii) generate insights into the causal pathways leading to heart failure and enable genetic approaches to target prioritization; and (iii) develop genomic tools for disease stratification and risk prediction.


Asunto(s)
Estudio de Asociación del Genoma Completo , Insuficiencia Cardíaca , Anciano , Anciano de 80 o más Años , Femenino , Genómica , Insuficiencia Cardíaca/genética , Humanos , Masculino , Persona de Mediana Edad , Pronóstico
2.
Europace ; 23(9): 1446-1455, 2021 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-33755136

RESUMEN

AIM: The Prevention of Arrhythmia Device Infection Trial (PADIT) infection risk score, developed based on a large prospectively collected data set, identified five independent predictors of cardiac implantable electronic device (CIED) infection. We performed an independent validation of the risk score in a data set extracted from U.S. healthcare claims. METHODS AND RESULTS: Retrospective identification of index CIED procedures among patients aged ≥18 years with at least one record of a CIED procedure between January 2011 and September 2014 in a U.S health claims database. PADIT risk factors and major CIED infections (with system removal, invasive procedure without system removal, or infection-attributable death) were identified through diagnosis and procedure codes. The data set was randomized by PADIT score into Data Set A (60%) and Data Set B (40%). A frailty model allowing multiple procedures per patient was fit using Data Set A, with PADIT score as the only predictor, excluding patients with prior CIED infection. A data set of 54 042 index procedures among 51 623 patients with 574 infections was extracted. Among patients with no history of prior CIED infection, a 1 unit increase in the PADIT score was associated with a relative 28% increase in infection risk. Prior CIED infection was associated with significant incremental predictive value (HR 5.66, P < 0.0001) after adjusting for PADIT score. A Harrell's C-statistic for the PADIT score and history of prior CIED infection was 0.76. CONCLUSION: The PADIT risk score predicts increased CIED infection risk, identifying higher risk patients that could potentially benefit from targeted interventions to reduce the risk of CIED infection. Prior CIED infection confers incremental predictive value to the PADIT score.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Adolescente , Adulto , Arritmias Cardíacas/terapia , Desfibriladores Implantables/efectos adversos , Atención a la Salud , Electrónica , Humanos , Marcapaso Artificial/efectos adversos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/prevención & control , Estudios Retrospectivos , Factores de Riesgo
3.
Nat Commun ; 11(1): 163, 2020 01 09.
Artículo en Inglés | MEDLINE | ID: mdl-31919418

RESUMEN

Heart failure (HF) is a leading cause of morbidity and mortality worldwide. A small proportion of HF cases are attributable to monogenic cardiomyopathies and existing genome-wide association studies (GWAS) have yielded only limited insights, leaving the observed heritability of HF largely unexplained. We report results from a GWAS meta-analysis of HF comprising 47,309 cases and 930,014 controls. Twelve independent variants at 11 genomic loci are associated with HF, all of which demonstrate one or more associations with coronary artery disease (CAD), atrial fibrillation, or reduced left ventricular function, suggesting shared genetic aetiology. Functional analysis of non-CAD-associated loci implicate genes involved in cardiac development (MYOZ1, SYNPO2L), protein homoeostasis (BAG3), and cellular senescence (CDKN1A). Mendelian randomisation analysis supports causal roles for several HF risk factors, and demonstrates CAD-independent effects for atrial fibrillation, body mass index, and hypertension. These findings extend our knowledge of the pathways underlying HF and may inform new therapeutic strategies.


Asunto(s)
Fibrilación Atrial/genética , Cardiomiopatías/genética , Enfermedad de la Arteria Coronaria/genética , Insuficiencia Cardíaca/genética , Insuficiencia Cardíaca/patología , Función Ventricular Izquierda/genética , Proteínas Adaptadoras Transductoras de Señales/genética , Proteínas Reguladoras de la Apoptosis/genética , Cardiomiopatías/patología , Proteínas Portadoras/genética , Estudios de Casos y Controles , Inhibidor p21 de las Quinasas Dependientes de la Ciclina/genética , Estudio de Asociación del Genoma Completo , Humanos , Análisis de la Aleatorización Mendeliana , Proteínas de Microfilamentos/genética , Proteínas Musculares/genética , Factores de Riesgo
4.
Nat Genet ; 50(9): 1225-1233, 2018 06 11.
Artículo en Inglés | MEDLINE | ID: mdl-29892015

RESUMEN

Atrial fibrillation (AF) affects more than 33 million individuals worldwide1 and has a complex heritability2. We conducted the largest meta-analysis of genome-wide association studies (GWAS) for AF to date, consisting of more than half a million individuals, including 65,446 with AF. In total, we identified 97 loci significantly associated with AF, including 67 that were novel in a combined-ancestry analysis, and 3 that were novel in a European-specific analysis. We sought to identify AF-associated genes at the GWAS loci by performing RNA-sequencing and expression quantitative trait locus analyses in 101 left atrial samples, the most relevant tissue for AF. We also performed transcriptome-wide analyses that identified 57 AF-associated genes, 42 of which overlap with GWAS loci. The identified loci implicate genes enriched within cardiac developmental, electrophysiological, contractile and structural pathways. These results extend our understanding of the biological pathways underlying AF and may facilitate the development of therapeutics for AF.


Asunto(s)
Fibrilación Atrial/genética , Etnicidad/genética , Fibrilación Atrial/etnología , Estudios de Casos y Controles , Predisposición Genética a la Enfermedad , Estudio de Asociación del Genoma Completo/métodos , Humanos , Sitios de Carácter Cuantitativo , Transcriptoma
5.
Cardiol Res Pract ; 2018: 9532141, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29862071

RESUMEN

Syncope is difficult to definitively diagnose, even with tilt-table testing and beat-to-beat blood pressure measurements, the gold-standard. Both are qualitative, subjective assessments. There are subtypes of syncope associated with autonomic conditions for which tilt-table testing is not useful. Heart rate variability analyses also include too much ambiguity. Three subtypes of syncope are differentiated: vasovagal syncope (VVS) due to parasympathetic excess (VVS-PE), VVS with abnormal heart rate response (VVS-HR), and VVS without PE (VVS-PN). P&S monitoring (ANSAR, Inc., Philadelphia, PA) differentiates subtypes in 2727 cardiology patients (50.5% female; average age: 57 years; age range: 12-100 years), serially tested over four years (3.3 tests per patient, average). P&S monitoring noninvasively, independently, and simultaneously measures parasympathetic and sympathetic (P&S) activity, including the normal P-decrease followed by an S-increase with head-up postural change (standing). Syncope, as an S-excess (SE) with stand, is differentiated from orthostatic dysfunction (e.g., POTS) as S-withdrawal with stand. Upon standing, VVS-PE is further differentiated as SE with PE, VVS-HR as SE with abnormal HR, and VVS-PN as SE with normal P- and HR-responses. Improved understanding of the underlying pathophysiology by more accurate subtyping leads to more precise therapy and improved outcomes.

6.
J Clin Invest ; 128(3): 1154-1163, 2018 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-29457789

RESUMEN

SCN5A encodes the voltage-gated Na+ channel NaV1.5 that is responsible for depolarization of the cardiac action potential and rapid intercellular conduction. Mutations disrupting the SCN5A coding sequence cause inherited arrhythmias and cardiomyopathy, and single-nucleotide polymorphisms (SNPs) linked to SCN5A splicing, localization, and function associate with heart failure-related sudden cardiac death. However, the clinical relevance of SNPs that modulate SCN5A expression levels remains understudied. We recently generated a transcriptome-wide map of microRNA (miR) binding sites in human heart, evaluated their overlap with common SNPs, and identified a synonymous SNP (rs1805126) adjacent to a miR-24 site within the SCN5A coding sequence. This SNP was previously shown to reproducibly associate with cardiac electrophysiological parameters, but was not considered to be causal. Here, we show that miR-24 potently suppresses SCN5A expression and that rs1805126 modulates this regulation. We found that the rs1805126 minor allele associates with decreased cardiac SCN5A expression and that heart failure subjects homozygous for the minor allele have decreased ejection fraction and increased mortality, but not increased ventricular tachyarrhythmias. In mice, we identified a potential basis for this in discovering that decreased Scn5a expression leads to accumulation of myocardial reactive oxygen species. Together, these data reiterate the importance of considering the mechanistic significance of synonymous SNPs as they relate to miRs and disease, and highlight a surprising link between SCN5A expression and nonarrhythmic death in heart failure.


Asunto(s)
Insuficiencia Cardíaca/genética , MicroARNs/genética , Canal de Sodio Activado por Voltaje NAV1.5/genética , Potenciales de Acción , Anciano , Alelos , Animales , Sitios de Unión , Muerte Súbita Cardíaca , Femenino , Perfilación de la Expresión Génica , Genotipo , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Homocigoto , Humanos , Desequilibrio de Ligamiento , Masculino , Ratones , Persona de Mediana Edad , Análisis de Secuencia por Matrices de Oligonucleótidos , Técnicas de Placa-Clamp , Polimorfismo de Nucleótido Simple , Ratas Sprague-Dawley
7.
J Cardiovasc Electrophysiol ; 27(6): 735-42, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26990515

RESUMEN

INTRODUCTION: Expert consensus holds that post-market, systematic surveillance of ICD leads is essential to ensure confirmation of adequate lead performance. GALAXY (NCT00836589) and CELESTIAL (NCT00810264) are ongoing multicenter, prospective, non-randomized registries conducted to confirm the long-term safety and reliability of Biotronik leads. METHODS AND RESULTS: ICD and CRT-D patients are followed for Linox and Linox(smart) ICD lead performance and safety for 5 years post-implant. All procedural and system-related adverse events (AEs) were assessed at each follow-up, along with lead electrical parameters. An independent CEC of EPs adjudicated AEs to determine AE category and lead relatedness. The analysis used categories of lead observations per ISO 5841-2 (Third edition). A total of 3,933 leads were implanted in 3,840 patients (73.0% male, mean age 67.0 ± 12.2 years) at 146 US centers. The estimated cumulative survival probability was 96.3% at 5 years after implant for Linox leads and 96.6% at 4 years after implant for Linox(smart) leads. A comparison of the Linox and Linox(smart) survival functions did not find evidence of a difference (P = 0.2155). The most common AEs were oversensing (23, 0.58%), conductor fracture (14, 0.36%), failure to capture (13, 0.33%), lead dislodgement (12, 0.31%), insulation breach (10, 0.25%), and abnormal pacing impedance (8, 0.20%). CONCLUSIONS: Linox and Linox(smart) ICD leads are safe, reliable and infrequently associated with lead-related AEs. Additionally, estimated cumulative survival probability is clinically acceptable and well within industry standards. Ongoing data collection will confirm the longer-term safety and performance of the Linox family of ICD leads.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Cardioversión Eléctrica/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Función Ventricular Izquierda
9.
J Am Heart Assoc ; 4(8): e001566, 2015 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-26231842

RESUMEN

BACKGROUND: Reduced left ventricular (LV) ejection fraction increases the risk of ventricular arrhythmias; however, LV ejection fraction has a low sensitivity to predict ventricular arrhythmias. LV dilatation and mass may be useful to further risk-stratify for ventricular arrhythmias. METHODS AND RESULTS: Patients from the Genetic Risk of Assessment of Defibrillator Events (GRADE) study (N=930), a study of heart failure subjects with defibrillators, were assessed for appropriate implantable cardioverter-defibrillator shock and death, heart transplant, or ventricular assist device placement by LV diameter and mass. LV mass was divided into normal, mild, moderate, and severe classifications. Severe LV end-diastolic diameter had worse shock-free survival than normal and mild LV end-diastolic diameter (P=0.0002 and 0.0063, respectively; 2-year shock free, severe 74%, moderate 80%, mild 91%, normal 88%; 4-year shock free, severe 62%, moderate 69%, mild 72%, normal 81%) and freedom from death, transplant, or ventricular assist device compared with normal and moderate LV end-diastolic diameter (P<0.0001 and 0.0441, respectively; 2-year survival: severe 78%, moderate 85%, mild 82%, normal 89%; 4-year survival: severe 55%, moderate 64%, mild 63%, normal 74%). Severe LV mass had worse shock-free survival than normal and mild LV mass (P=0.0370 and 0.0280, respectively; 2-year shock free: severe 80%, moderate 81%, mild 91%, normal 87%; 4-year shock free: severe 68%, moderate 73%, mild 76%, normal 76%) but no association with death, transplant, or ventricular assist device (P=0.1319). In a multivariable Cox proportional hazards analysis adjusted for LV ejection fraction, LV end-diastolic diameter was associated with appropriate implantable cardioverter-defibrillator shocks (hazard ratio 1.22, P=0.020). LV end-diastolic diameter was associated with time to death, transplant, or ventricular assist device (hazard ratio 1.29, P=0.0009). CONCLUSIONS: LV dilatation may complement ejection fraction to predict ventricular arrhythmias. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02045043.


Asunto(s)
Arritmias Cardíacas/etiología , Hipertrofia Ventricular Izquierda/complicaciones , Disfunción Ventricular Izquierda/complicaciones , Función Ventricular Izquierda , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/terapia , Distribución de Chi-Cuadrado , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Dilatación Patológica , Supervivencia sin Enfermedad , Cardioversión Eléctrica/instrumentación , Femenino , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Trasplante de Corazón , Corazón Auxiliar , Humanos , Hipertrofia Ventricular Izquierda/diagnóstico , Hipertrofia Ventricular Izquierda/mortalidad , Hipertrofia Ventricular Izquierda/fisiopatología , Hipertrofia Ventricular Izquierda/terapia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Análisis Multivariante , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo , Sístole , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/mortalidad , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/terapia
10.
Am J Cardiol ; 115(7): 924-31, 2015 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-25682436

RESUMEN

Sudden cardiac death (SCD) is a leading cause of mortality in patients with cardiomyopathy. Although angiotensin-converting enzyme inhibitors (ACEi) and angiotensin receptor blockers (ARBs) decrease cardiac mortality in these cohorts, their role in preventing SCD has not been well established. We sought to determine whether the use of ACEi or ARB in patients with cardiomyopathy is associated with a lower incidence of appropriate implantable cardiac defibrillator (ICD) shocks in the Genetic Risk Assessment of Defibrillator Events study that included subjects with an ejection fraction of ≤30% and ICDs. Treatment with ACEi/ARB versus no-ACEi/ARB was physician dependent. There were 1,509 patients (mean age [SD] 63 [12] years, 80% men, mean [SD] EF 21% [6%]) with 1,213 (80%) on ACEi/ARB and 296 (20%) not on ACEi/ARB. We identified 574 propensity-matched patients (287 in each group). After a mean (SD) of 2.5 (1.9) years, there were 334 (22%) appropriate shocks in the entire cohort. The use of ACEi/ARB was associated with lower incidence of shocks at 1, 3, and 5 years in the matched cohort (7.7%, 16.7%, and 18.5% vs 13.2%, 27.5%, and 32.0%; RR = 0.61 [0.43 to 0.86]; p = 0.005). Among patients with glomerular filtration rate (GFR) >60 and 30 to 60 ml/min/1.73 m(2), those on no-ACEi/ARB were at 45% and 77% increased risk of ICD shock compared with those on ACEi/ARB, respectively. ACEi/ARB were associated with significant lower incidence of appropriate ICD shock in patients with cardiomyopathy and GFR ≥30 ml/min/1.73 m(2) and with neutral effect in those with GFR <30 ml/min/1.73 m(2).


Asunto(s)
Antagonistas de Receptores de Angiotensina/uso terapéutico , Inhibidores de la Enzima Convertidora de Angiotensina/uso terapéutico , Insuficiencia Cardíaca Sistólica/terapia , Medición de Riesgo/métodos , Anciano , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca Sistólica/mortalidad , Insuficiencia Cardíaca Sistólica/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Tasa de Supervivencia/tendencias , Factores de Tiempo , Estados Unidos/epidemiología
11.
Med Devices (Auckl) ; 8: 71-8, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25624774

RESUMEN

Cardiovascular implantable electronic device system infection is a serious complication of cardiac device implantation and carries with it a risk of significant morbidity and mortality. In the last 15 years, expansions of indications for cardiac devices have resulted in much higher volumes of much sicker patients being implanted, carrying significant risk of infection. Coagulase (-) Staphylococcus and Staphylococcus aureus are responsible for the majority of these infections, and these organisms are increasingly resistant to methicillin. The Aigis™ envelop is a Food and Drug Administration-approved implantable mesh that is impregnated with antibiotics that can be placed in the surgical incision prior to closure. The antibiotics elute off the mesh for 7-10 days, providing in vivo surgical site coverage with rifampin and minocyclin. This paper reviews the three retrospective clinical trials published in peer-reviewed journals and the interim analysis of the two ongoing prospective trials that have been presented at international conferences. Overall consensus is that the Aigis™ offers significant risk reduction for cardiovascular implantable electronic device infection. We then give a comprehensive discussion of how to use the Aigis™ envelop in the clinical setting, comparing the manufacturer's recommendations with our extensive clinical experience.

12.
Heart Int ; 9(1): 7-14, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-27004091

RESUMEN

BACKGROUND: Cardiovascular autonomic neuropathy (CAN) is recognized as a significant health risk. Specific and sensitive measures of CAN are needed for early identification and treatment to avoid complications, preferably in the preclinical state. OBJECTIVES: In this first of two articles, the patient cohort is described and two measures of autonomic function are reviewed: the traditional heart rate variability (HRV)-alone method and the newer parasympathetic and sympathetic (P&S) Method. These systems are then evaluated against known effects of the alpha/beta-adrenergic blocker, Carvedilol, and the selective beta-adrenergic blocker, Metoprolol, on P&S activity. METHODS: Serial autonomic nervous system test data from 147 type 2 diabetes mellitus patients from eight ambulatory clinics were analyzed. Patients were grouped according to whether a beta-blocker was (1) introduced, (2) discontinued or (3) continued without adjustment. Group 3 served as the control. HRV-alone parameters are computed according to standards. The P&S Method, which is a time-frequency analyses of concurrent respiratory activity and HRV, is elucidated, as developed at MIT and Harvard Medical School (1981). RESULTS: The HRV-alone demonstrated that introducing either medication increased low frequency (msec(2)) and standard deviation of the beat-to-beat (N-N) interval (msec), as expected. The other HRV parameter responses were not consistent with expectations. Similar inconsistencies occurred when either medication was discontinued. The P&S Method demonstrated that introducing or discontinuing either agent decreased or increased sympathetic activity, respectively, according to expectations. With ongoing treatment, resting parasympathetic activity decreased with Metoprolol but increased with Carvedilol. CONCLUSION: Autonomic assessment fidelity was significantly higher with the P&S Method as validated by comparison with previously known physiology of the cardiovascular system.

13.
Heart Int ; 9(1): 15-21, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-27004092

RESUMEN

BACKGROUND: Cardiovascular autonomic neuropathy (CAN) is recognized as a significant health risk, correlating with risk of heart disease, silent myocardial ischemia or sudden cardiac death. Beta-blockers are often prescribed to minimize risk. OBJECTIVES: In this second of two articles, the effects on parasympathetic and sympathetic activity of the alpha/beta-adrenergic blocker, Carvedilol, are compared with those of the selective beta-adrenergic blocker, Metoprolol. METHODS: Retrospective, serial autonomic nervous system test data from 147 type 2 diabetes mellitus patients from eight ambulatory clinics were analyzed. Patients were grouped according to whether a beta-blocker was (1) introduced, (2) discontinued or (3) continued without adjustment. Group 3 served as the control. RESULTS: Introducing Carvedilol or Metoprolol decreased heart rate and blood pressure, and discontinuing them had the opposite effect. Parasympathetic activity increased with introducing Carvedilol. Sympathetic activity increased more after discontinuing Carvedilol, suggesting better sympathetic suppression. With ongoing treatment, resting parasympathetic activity decreased with Metoprolol but increased with Carvedilol. CONCLUSION: Carvedilol has a more profound effect on sympathovagal balance than Metoprolol. While both suppress sympathetic activity, only Carvedilol increases parasympathetic activity. Increased parasympathetic activity may underlie the lower mortality risk with Carvedilol.

14.
J Card Fail ; 18(9): 717-23, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22939041

RESUMEN

BACKGROUND: Sudden cardiac death (SCD) from ventricular tachyarrhythmias accounts for approximately 450,000 annual deaths in the United States; many of these cases involve patients with chronic heart failure (HF). Prediction of which HF patients are most susceptible to SCD is difficult, and it is uncertain whether gene polymorphisms associated with HF outcomes are also linked to arrhythmic risk. METHODS: We evaluated 485 patients with chronic HF to see whether the angiotensin receptor type 1 (AT1R) 1166A/C or angiotensin-converting enzyme insertion/deletion (ACE I/D) polymorphisms were associated with a higher rate of ventricular arrhythmias requiring implantable cardioverter defibrillator (ICD) therapies over a 5-year period. We assessed the correlation between polymorphisms and antitachycardia pacing (ATP) and/or ICD shocks. RESULTS: Patients with AT1R-1166CC genotype had an increased rate of all events: ATP plus ICD shocks (P = .02). There was no association between ACE I/D genotype and ICD therapies. Furthermore, circulating levels of microRNA-155 (miR-155), a microRNA known to posttranscriptionally regulate AT1R expression, were significantly decreased in the CC compared with the AC and AA genotypes and were associated with ICD events. CONCLUSION: Our study suggests that the AT1R-1166CC genotype is associated with increased ICD therapies in patients with chronic HF, and the level of circulating miR-155 may be a potential marker for arrhythmic risk. Although these findings are novel, they will need replication and validation in larger cohorts of chronic HF patients.


Asunto(s)
Arritmias Cardíacas/genética , Muerte Súbita Cardíaca/patología , Desfibriladores Implantables , Insuficiencia Cardíaca/genética , MicroARNs/genética , Receptor de Angiotensina Tipo 1/genética , Arritmias Cardíacas/patología , Arritmias Cardíacas/terapia , Femenino , Genotipo , Insuficiencia Cardíaca/patología , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad , Polimorfismo de Nucleótido Simple , Riesgo , Estadística como Asunto
15.
Heart Rhythm ; 9(3): 390-6, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22004663

RESUMEN

BACKGROUND: Dilated cardiomyopathy (DCM) is a leading cause of heart failure and death. The etiology of DCM is genetically heterogeneous. OBJECTIVES: We sought to define the prevalence of mutations in the RNA splicing protein RBM20 in a large cohort with DCM and to determine whether genetic variation in RBM20 is associated with clinical outcomes. METHODS: Subjects included in the Genetic Risk Assessment of Defibrillator Events (GRADE) study were aged at least 18 years, had an ejection fraction of ≤30%, and an implantable cardioverter-defibrillator (ICD). The coding region and splice junctions of RBM20 were screened in subjects with DCM; 2 common polymorphisms in RBM20, rs942077 and rs35141404, were genotyped in all GRADE subjects. RESULTS: A total of 1465 subjects were enrolled in the GRADE study, and 283 with DCM were screened for RBM20 mutations. The mean age of subjects with DCM was 58 ± 13 years, 64% were males, and the mean follow-up time was 24.2 ± 17.1 months after ICD placement. RBM20 mutations were identified in 8 subjects with DCM (2.8%). Mutation carriers had a similar survival, transplantation rate, and frequency of ICD therapy compared with nonmutation carriers. Three of 8 subjects with RBM20 mutations (37.5%) had atrial fibrillation (AF), whereas 19 subjects without mutations (7.4%) had AF (P = .02). Among all GRADE subjects, rs35141404 was associated with AF (minor allele odds ratio = 0.62; 95% confidence interval = 0.44-0.86; P = .006). In the subset of GRADE subjects with DCM, rs35141404 was associated with AF (minor allele odds ratio = 0.58; P = .047). CONCLUSIONS: Mutations in RBM20 were observed in approximately 3% of subjects with DCM. There were no differences in survival, transplantation rate, and frequency of ICD therapy in mutation carriers.


Asunto(s)
Arritmias Cardíacas , Estimulación Cardíaca Artificial/métodos , Cardiomiopatía Dilatada , Trasplante de Corazón/estadística & datos numéricos , Proteínas de Unión al ARN/genética , Adulto , Anciano , Empalme Alternativo/genética , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/etiología , Arritmias Cardíacas/genética , Arritmias Cardíacas/terapia , Cardiomiopatía Dilatada/complicaciones , Cardiomiopatía Dilatada/diagnóstico , Cardiomiopatía Dilatada/genética , Cardiomiopatía Dilatada/mortalidad , Cardiomiopatía Dilatada/terapia , Desfibriladores Implantables , Femenino , Humanos , Masculino , Persona de Mediana Edad , Mutación Missense , Polimorfismo de Nucleótido Simple , Prevalencia , Sitios de Empalme de ARN/genética , Medición de Riesgo , Volumen Sistólico , Tasa de Supervivencia , Estados Unidos/epidemiología
16.
J Cardiovasc Electrophysiol ; 22(4): 414-9, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20946227

RESUMEN

BACKGROUND: Inflammation and oxidative stress are associated with atrial fibrillation (AF). Statins have antioxidant and anti-inflammatory properties. We tested if atorvastatin reduced AF recurrence after DC cardioversion (CV) by modifying systemic oxidative stress and inflammation (NCT00252967). METHODS AND RESULTS: In a randomized, double-blinded, placebo-controlled trial, patients with atrial fibrillation/flutter (AF) were randomized to receive either atorvastatin 80 mg (n = 33) or placebo (n = 31) before CV. Treatment was continued for 12 months or until AF recurred. Serum oxidative stress markers (ratios of oxidized to reduced glutathione and cysteine, derivatives of reactive oxygen species, isoprostanes) and inflammatory markers (high-sensitivity C- reactive protein [hs-CRP], interleukin-6 [IL-6], interleukin-1ß[IL-1ß], tumor necrosis factor alpha [TNFα]) were measured at baseline and on follow-up. AF recurred in 22 (66.7%) of atorvastatin and 26 (83.9%) of placebo group (P = 0.2). The adjusted hazard ratio of having recurrence on atorvastatin versus on placebo was 0.99 (95% CI: 0.98-1.01, P = 0.3). There was no significant difference in the time to recurrence using Kaplan-Meier survival estimates (median [IR]: 29 [2-145] days versus 22 [7-70] days, P = 0.9). Although no significant effect was seen on oxidative stress, 2 of 4 inflammatory markers, IL-6 (adjusted OR: 0.59, 95% CI: 0.35-0.97, P = 0.04) and hs-CRP (adjusted OR: 0.59, 95% CI: 0.37-0.95, P = 0.03) were significantly lowered with atorvastatin. Cholesterol levels significantly decreased with atorvastatin (P = 0.03). CONCLUSIONS: High-dose atorvastatin did not reduce the recurrence of AF after CV. It reduced selective markers of inflammation without affecting systemic oxidative stress. Failure of atorvastatin to prevent AF recurrence may be due to its failure to affect oxidative stress.


Asunto(s)
Fibrilación Atrial/sangre , Fibrilación Atrial/prevención & control , Ácidos Heptanoicos/uso terapéutico , Pirroles/uso terapéutico , Anciano , Atorvastatina , Fibrilación Atrial/etiología , Biomarcadores/sangre , Método Doble Ciego , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/métodos , Femenino , Estudios de Seguimiento , Humanos , Mediadores de Inflamación/sangre , Masculino , Persona de Mediana Edad , Estrés Oxidativo/fisiología , Resultado del Tratamiento
17.
Pacing Clin Electrophysiol ; 34(2): 133-42, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20942819

RESUMEN

BACKGROUND: Cardiovascular implantable electronic device (CIED) infection rates are increasing faster than implantation rates. More effective antimicrobial prophylaxis may help reduce CIED infections and improve clinical outcomes. The AIGIS(Rx)(®) antibacterial envelope is a polymer mesh implanted in the generator pocket with the CIED. After implantation it releases two antibiotics, minocycline and rifampin, that have been shown to reduce infections associated with other medical devices. The purpose of this retrospective cohort study is to determine the rate of CIED implantation success and CIED infection in procedures utilizing the antibacterial envelope. METHODS: This study enrolled consecutive CIED procedures utilizing the antibacterial envelope at 10 US academic, community, and Veterans Affairs medical centers. Procedures following an explantation for a prior CIED infection or off-label use of the antibacterial envelope were excluded. RESULTS: The 624 eligible procedures (age 70 ± 13 years, 68.1% men, 27.2% renal insufficiency, 35.4% oral anticoagulant use, 67.8% replacement/revision procedures) utilized pacemakers (35%), implantable cardioverter-defibrillators (ICD)(29%), and cardiac resynchronization therapy with defibrillator devices (CRT-D)(36%). Nearly half of the patients (49%) had at least three predefined risk factors for CIED infection. CIED implantation was successful in 621 procedures (99.5%[95% confidence interval (CI) 98.8-99.9]). There were three major infections (0.48%[95%CI 0.17-1.40]) after 1.9 ± 2.4 months follow-up. The infections followed one ICD revision and two CRT-D replacements. There were seven deaths; none was a result of the antibacterial envelope or the CIED procedure. CONCLUSIONS: CIED procedures that utilized an antibacterial envelope had a high rate of CIED implantation success (>99%). Although the follow-up to date is short, there was also a low rate of infection (<0.50%) in this population at high risk for CIED infection.


Asunto(s)
Antibacterianos/administración & dosificación , Desfibriladores Implantables/estadística & datos numéricos , Miocarditis/epidemiología , Miocarditis/prevención & control , Marcapaso Artificial/estadística & datos numéricos , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/prevención & control , Anciano , Implantes de Medicamentos/administración & dosificación , Femenino , Humanos , Masculino , Prevalencia , Pronóstico , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento , Estados Unidos/epidemiología
18.
Cardiol Res Pract ; 2010: 253803, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20369058

RESUMEN

Recent studies demonstrate that statins decrease ventricular arrhythmias in internal cardioverter defibrillator (ICD) patients. The mechanism is unknown, but evidence links increased inflammatory and oxidative states with increased arrhythmias. We hypothesized that statin use decreases oxidation. Methods. 304 subjects with ICDs were surveyed for ventricular arrhythmia. Blood was analyzed for derivatives of reactive oxygen species (DROMs) and interleukin-6 (IL-6). Results. Subjects included 252 (83%) men, 58% on statins, 20% had ventricular arrhythmias. Average age was 63 years and ejection fraction (EF) 20%. ICD implant duration was 29 +/- 27 months. Use of statins correlated with lower ICD events (r = 0.12, P = .02). Subjects on statins had lower hsCRP (5.2 versus 6.3; P = .05) and DROM levels (373 versus 397; P = .03). Other factors, including IL-6 and EF did not differ between statin and nonstatin use, nor did beta-blocker or antiarrhythmic use. Multivariate cross-correlation analysis demonstrated that DROMs, statins, IL-6 and EF were strongly associated with ICD events. Multivariate regression shows DROMs to be the dominant predictor. Conclusion. ICD event rate correlates with DROMs, a measure of lipid peroxides. Use of statins is associated with reduced DROMs and fewer ICD events, suggesting that statins exert their effect through reducing oxidation.

20.
F1000 Med Rep ; 12009 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-20948708

RESUMEN

Ventricular tachycardia (VT) is a leading cause of morbidity and mortality for many patients, with a significant emotional and economic burden caused by implantable cardioverter-defibrillator (ICD) shocks and the requirement of medication with significant side effects. Additionally, 10% of VT occurs in patients with no structural heart disease. Until quite recently, ablation for VT has been reserved as the procedure of last hope for those who have ongoing recurrences despite maximal medical therapy and who are traumatized by multiple ICD shocks [1]. However, recent advances in imaging technology and three-dimensional intracardiac mapping systems have significantly improved the safety and efficacy of VT ablation procedures. Thus, ablation for VT should no longer be reserved as a last-resort bailout procedure and should move into the realm of routine electrophysiology treatment.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...