Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 129
Filtrar
1.
AJNR Am J Neuroradiol ; 38(12): 2257-2263, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28982793

RESUMEN

BACKGROUND AND PURPOSE: Photon-counting detectors offer the potential for improved image quality for brain CT but have not yet been evaluated in vivo. The purpose of this study was to compare photon-counting detector CT with conventional energy-integrating detector CT for human brains. MATERIALS AND METHODS: Radiation dose-matched energy-integrating detector and photon-counting detector head CT scans were acquired with standardized protocols (tube voltage/current, 120 kV(peak)/370 mAs) in both an anthropomorphic head phantom and 21 human asymptomatic volunteers (mean age, 58.9 ± 8.5 years). Photon-counting detector thresholds were 22 and 52 keV (low-energy bin, 22-52 keV; high-energy bin, 52-120 keV). Image noise, gray matter, and white matter signal-to-noise ratios and GM-WM contrast and contrast-to-noise ratios were measured. Image quality was scored by 2 neuroradiologists blinded to the CT detector type. Reproducibility was assessed with the intraclass correlation coefficient. Energy-integrating detector and photon-counting detector CT images were compared using a paired t test and the Wilcoxon signed rank test. RESULTS: Photon-counting detector CT images received higher reader scores for GM-WM differentiation with lower image noise (all P < .001). Intrareader and interreader reproducibility was excellent (intraclass correlation coefficient, ≥0.86 and 0.79, respectively). Quantitative analysis showed 12.8%-20.6% less image noise for photon-counting detector CT. The SNR of photon-counting detector CT was 19.0%-20.0% higher than of energy-integrating detector CT for GM and WM. The contrast-to-noise ratio of photon-counting detector CT was 15.7% higher for GM-WM contrast and 33.3% higher for GM-WM contrast-to-noise ratio. CONCLUSIONS: Photon-counting detector brain CT scans demonstrated greater gray-white matter contrast compared with conventional CT. This was due to both higher soft-tissue contrast and lower image noise for photon-counting CT.


Asunto(s)
Encéfalo/diagnóstico por imagen , Neuroimagen/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Fotones , Reproducibilidad de los Resultados , Relación Señal-Ruido
2.
Diagn Interv Imaging ; 98(1): 3-10, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27423708

RESUMEN

Cardiovascular risk assessment has assumed a prominent role in the course of preventive care of all adults. Traditionally cardiovascular risk assessment has been performed using risk factors including gender, age, smoking history, lipid status, diabetes status, and family history. Increasingly, imaging has been deployed to directly detect coronary atherosclerotic disease. Quantification of coronary calcium (e.g., Agatston method, calcium mass and volume) is readily detected using helical CT scanners. Large multicenter cohort studies have enabled a better understanding of the relevance of coronary calcium detection. The purpose of this review is to review the methods for quantification of coronary artery calcium, as well as to present current and future perspectives on calcium scoring for cardiovascular risk stratification.


Asunto(s)
Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Medición de Riesgo , Tomografía Computarizada por Rayos X , Calcificación Vascular/diagnóstico por imagen , Humanos , Cooperación del Paciente , Guías de Práctica Clínica como Asunto , Factores de Riesgo
4.
Nutr Metab Cardiovasc Dis ; 25(7): 667-76, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26033394

RESUMEN

BACKGROUND AND AIMS: Visceral fat (VF) is a source of pro-inflammatory adipokines implicated in cardiac remodeling. We sought to determine the impact of visceral fat and subcutaneous fat (SQ) depots on left ventricular (LV) structure, function, and geometry in the Multi-Ethnic Study of Atherosclerosis (MESA). METHODS AND RESULTS: We performed a post-hoc analysis on 1151 participants from MESA with cardiac magnetic resonance quantification of LV mass and LV mass-to-volume ratio (LVMV, an index of concentricity) and computed tomographic-derived SQ and VF area. Multivariable regression models to estimate association between height-indexed SQ and VF area (per cm(2)/m) with height-indexed LV mass (per height(2.7)) and LVMV were constructed, adjusted for clinical, biochemical, and demographic covariates. We found that both VF and SQ area were associated with height-indexed LV mass (ρ = 0.36 and 0.12, P < 0.0001, respectively), while only VF area was associated with LVMV (ρ = 0.28, P < 0.0001). Individuals with above-median VF had lower LV ejection fraction, greater indexed LV volumes and mass, and higher LVMV (all P < 0.001). In multivariable models adjusted for weight, VF (but not SQ) area was associated with LV concentricity and LV mass index, across both sexes. CONCLUSION: Visceral adiposity is independently associated with LV concentricity, a precursor to heart failure. Further study into the role of VF in LV remodeling as a potential therapeutic target is warranted.


Asunto(s)
Aterosclerosis/patología , Obesidad Abdominal/etnología , Remodelación Ventricular , Adipoquinas/metabolismo , Anciano , Índice de Masa Corporal , Etnicidad , Femenino , Ventrículos Cardíacos/patología , Humanos , Grasa Intraabdominal/patología , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Volumen Sistólico , Grasa Subcutánea/patología , Tomografía Computarizada por Rayos X , Estados Unidos
5.
Mol Imaging Biol ; 17(3): 297-312, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25672749

RESUMEN

This paper summarises the proceedings and discussions at the third annual workshop held in Tübingen, Germany, dedicated to the advancement of the technical, scientific and clinical applications of combined PET/MRI systems in humans. Two days of basic scientific and technical instructions with "hands-on" tutorials were followed by 3 days of invited presentations from active researchers in this and associated fields augmented by round-table discussions and dialogue boards with specific themes. These included the use of PET/MRI in paediatric oncology and in adult neurology, oncology and cardiology, the development of multi-parametric analyses, and efforts to standardise PET/MRI examinations to allow pooling of data for evaluating the technology. A poll taken on the final day demonstrated that over 50 % of those present felt that while PET/MRI technology underwent an inevitable slump after its much-anticipated initial launch, it was now entering a period of slow, progressive development, with new key applications emerging. In particular, researchers are focusing on exploiting the complementary nature of the physiological (PET) and biochemical (MRI/MRS) data within the morphological framework (MRI) that these devices can provide. Much of the discussion was summed up on the final day when one speaker commented on the state of PET/MRI: "the real work has just started".


Asunto(s)
Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Tomografía de Emisión de Positrones/métodos , Animales , Cardiología/métodos , Alemania , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Oncología Médica/métodos , Neurología/métodos
6.
Br J Radiol ; 85(1019): e1145-54, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23091294

RESUMEN

Delayed enhancement cardiac magnetic resonance (DE-CMR) imaging is used increasingly to identify and quantify focal myocardial scar. Our objective is to describe factors used in the interpretation of DE-CMR images and to highlight potential pitfalls and artefacts that mimic myocardial scar. Inversion recovery gradient recalled echo sequence is commonly accepted as the standard of reference for DE-CMR. There are also alternative sequences that can be performed in a single breath-hold or with free breathing. Radiologists need to be aware of factors affecting image quality, and potential pitfalls and artefacts that may generate focal hyperintense areas that mimic myocardial scar.


Asunto(s)
Cicatriz/patología , Imagen por Resonancia Magnética , Miocardio/patología , Cicatriz/diagnóstico , Humanos , Aumento de la Imagen , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/normas , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/patología , Control de Calidad
7.
Nutr Metab Cardiovasc Dis ; 21(5): 332-8, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-20153618

RESUMEN

BACKGROUND AND AIMS: Arterial stiffness is a prominent feature of vascular aging and a risk factor for cardiovascular disease (CVD). Fat around the heart and blood vessels (i.e. pericardial fat, Pfat) may contribute to arterial stiffness via a local paracrine effect of adipose tissue on the surrounding vasculature. Thus, we determined the association between Pfat and carotid stiffness in 5770 participants (mean age 62 years, 53% female, 25% African American, 24% Hispanic, and 13% Chinese) from the Multi-Ethnic Study of Atherosclerosis. METHODS AND RESULTS: Pfat was measured by computed tomography, and ultrasonography of the common carotid artery was used to calculate the distensibility coefficient (DC) and Young's modulus (YM). Lower DC and higher YM values indicate stiffer arteries. Pfat quartile was highly associated with demographic, behavioral, anthropometric, hemodynamic, metabolic, and disease variables in both men and women. After adjusting for height, clinical site, CVD risk factors, and medications, a 1 standard deviation (41.91 cm(3)) increment in Pfat was associated with a 0.00007±0.00002 1/mm Hg lower DC (p=0.0002) in men and a 48.1±15.1 mm Hg/mm higher YM in women (p=0.002). Additional adjustment for C-reactive protein, coronary artery calcification, and carotid intima-media thickness had only modest effects. More importantly, adjusting for body mass index and waist circumference did not significantly change the overall results. CONCLUSION: Higher Pfat is associated with higher carotid stiffness, independent of traditional CVD risk factors and obesity.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Aterosclerosis/etnología , Arteria Carótida Común/patología , Etnicidad , Pericardio/diagnóstico por imagen , Tejido Adiposo/fisiopatología , Anciano , Aterosclerosis/complicaciones , Aterosclerosis/diagnóstico , Aterosclerosis/diagnóstico por imagen , Composición Corporal , Proteína C-Reactiva/metabolismo , Arteria Carótida Común/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/etnología , Módulo de Elasticidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Obesidad/complicaciones , Obesidad/diagnóstico por imagen , Estudios Prospectivos , Factores de Riesgo , Tomografía Computarizada por Rayos X , Circunferencia de la Cintura
8.
J Hum Hypertens ; 25(1): 25-31, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20237502

RESUMEN

Brachial flow-mediated dilation (FMD) is a measure of endothelial nitric oxide bioavailability. Endothelial nitric oxide controls vascular tone and is likely to modify the ventricular muscle coupling mechanism. The association between left ventricular mass and FMD is not well understood. We assessed the association between left ventricular mass index (LVMI) and FMD in participants of the Multi-Ethnic Study of Atherosclerosis (MESA). MESA is a population-based study of 6814 adults free of clinical cardiovascular disease at baseline who were recruited from six US clinics. LVMI (left ventricular mass per body surface area) and FMD were measured in 2447 subjects. Linear regression analysis was used to evaluate the association. The subjects had a mean age of 61.2±9.9 years, 51.2% females with 34.3% Caucasians, 21.6% Chinese, 19.4% African Americans and 24.7% Hispanics. The mean body mass index (BMI) was 27.4±4.8 kg m⁻², 9.4% had diabetes, 11% were current smokers and 38% hypertensives. The mean±s.d. LVMI was 78.1±15.9 g m⁻² and mean±s.d. FMD was 4.4%±2.8%. In univariate analysis, LVMI was inversely correlated with FMD (r= -0.20, P<0.0001). In the multivariable analysis, LVMI was associated with FMD (ß coefficient (se) = -0.50 (0.11), P<0.001 (0.5 g m⁻² reduction in LVMI per 1% increase in FMD)) after adjusting for age, gender, race/ethnicity, systolic blood pressure, diabetes mellitus, smoking, weight, statin use, antihypertensive medication use, high-density lipoprotein (HDL) and low-density lipoprotein (LDL) cholesterol. The association between brachial flow mediated dilation and LVMI maybe independent of traditional CV risk factors in population based adults.


Asunto(s)
Aterosclerosis/etnología , Aterosclerosis/fisiopatología , Arteria Braquial/fisiopatología , Endotelio Vascular/fisiopatología , Ventrículos Cardíacos/patología , Flujo Sanguíneo Regional/fisiología , Negro o Afroamericano/etnología , Anciano , Anciano de 80 o más Años , Asiático/etnología , Estudios de Cohortes , Femenino , Hispánicos o Latinos/etnología , Humanos , Modelos Lineales , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Óxido Nítrico , Tamaño de los Órganos , Estudios Prospectivos , Estudios Retrospectivos , Población Blanca/etnología
9.
Heart ; 96(1): 42-8, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19858139

RESUMEN

OBJECTIVE: To evaluate the association of physical activity with left ventricular structure and function in the general population in a community setting. DESIGN: Cross-sectional study. SETTING: The Multi-Ethnic Study of Atherosclerosis (MESA), a population-based study of subclinical atherosclerosis. PARTICIPANTS: A multiethnic sample of 4992 participants (aged 45-84 years; 52% female) free of clinically apparent cardiovascular disease. INTERVENTIONS: Physical activity induces beneficial physiological cardiac remodelling in a cross-sectional study of non-athlete individuals. MAIN OUTCOME MEASURES: Left ventricular mass, volumes and function were assessed by cardiac magnetic resonance imaging. Physical activity, defined as intentional exercise and total moderate and vigorous physical activity, was assessed by a standard semiquantitative questionnaire. RESULTS: Left ventricular mass and end-diastolic volume were positively associated with physical activity (eg, 1.4 g/m(2) (women) and 3.1 g/m(2) (men) greater left ventricular mass in the highest category of intentional exercise compared with individuals reporting no intentional exercise; p = 0.05 and p<0.001, respectively). Relationships were non-linear, with stronger positive associations at lower levels of physical activity (test for non-linearity; p = 0.02 and p = 0.03, respectively). Cardiac output and ejection fraction were unchanged with increased physical activity levels. Resting heart rate was lower in women and men with higher physical activity levels (eg, -2.6 beats/minute lower resting heart rate in the highest category of intentional exercise compared with individuals reporting no intentional exercise; p<0.001). CONCLUSIONS: In a community-based population free of clinically apparent cardiovascular disease, higher physical activity levels were associated with proportionally greater left ventricular mass and end-diastolic volume and lower resting heart rate.


Asunto(s)
Ejercicio Físico/fisiología , Ventrículos Cardíacos/anatomía & histología , Función Ventricular Izquierda/fisiología , Remodelación Ventricular/fisiología , Factores de Edad , Anciano , Anciano de 80 o más Años , Gasto Cardíaco/fisiología , Volumen Cardíaco/fisiología , Estudios Transversales , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Caracteres Sexuales
10.
JBR-BTR ; 90(2): 124-7, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17555074

RESUMEN

We compared two-dimensional (2D) and three-dimensional (3D) inversion recovery prepared (IR) fast gradient echo (FGRE) and steady state free precession (SSFP) sequences used in myocardial delayed enhancement imaging. Twenty patients with a prior history of acute coronary syndrome were included in this study. Breath hold, ECG gated, segmented 2D and 3D IR_FGRE and SSFP sequences were acquired after intravenous administration of 0.15 mmol/kg gadodiamide-DTPA. Overall image quality, transmural extent of myocardial infarction, infarct volume, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and signal intensity ratio (SIR) were calculated and compared for each technique. 3D IR trueFISP showed significantly higher mean values of SNR and CNR compared with 3D IR turboFLASH, 2D IR turboFLASH and 2D IR trueFISP (p < 0.04 and p < 0.001). 3D IR_FGRE showed the second highest SNR and CNR. 3D IR_SSFP and 3D IR_FGRE allowed the imaging of the whole heart within a single breath-hold which reduced the imaging time significantly compared to 2D IR_FGRE and 2D IR_SSFP. 3D IR_SSFP and 3D IR_FGRE offer higher SNR, CNR and rapid acquisiton compared to 2D IR_SSFP and 2D IR_FGRE with adequate image quality.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Infarto del Miocardio/patología , Adulto , Anciano , Análisis de Varianza , Medios de Contraste , Femenino , Gadolinio DTPA , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad
11.
Pediatr Cardiol ; 27(3): 316-20, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16565909

RESUMEN

The objective of this study was to determine if distortion of the left subclavian artery course distinguishes double aortic arch with atretic left dorsal aorta from right aortic arch with mirror image branching. We performed a retrospective case series at a tertiary care center. Twenty-six patients undergoing magnetic resonance imaging for suspicion of a vascular ring were identified, 6 of whom had an atretic left dorsal aorta confirmed by surgical inspection. Six patients with the diagnosis of right aortic arch with mirror image branching were identified for comparison. The course of the left subclavian artery was assessed using surface-rendered magnetic resonance angiography (MRA) and axial fast spin echo images. All patients with double aortic arch had clinical symptoms suggestive of esophageal or tracheal compression. Six patients had double aortic arch, 3 of whom had an atretic left dorsal aorta. In these 3 patients, the branching patterns on MRA mimicked right aortic arch mirror image branching except for the distortion of the initial course of the left subclavian artery. Surgical observation confirmed the presence of an atretic left dorsal aorta that resulted in tension on the left subclavian artery pulling it posteriorly and inferiorly and completing the vascular ring. Patients with right aortic arch mirror image branching demonstrated no such subclavian artery distortion, and these patients did not have clinical symptoms suggestive of a vascular ring. Our results demonstrate that left subclavian artery distortion due to traction by an atretic left arch is an important diagnostic finding in the evaluation 6 patients with suspected vascular rings.


Asunto(s)
Aorta Torácica/anomalías , Anomalías Cardiovasculares/diagnóstico , Imagen por Resonancia Magnética , Arteria Subclavia/anomalías , Adolescente , Niño , Preescolar , Femenino , Humanos , Lactante , Angiografía por Resonancia Magnética , Masculino , Estudios Retrospectivos
12.
Heart ; 92(5): 589-97, 2006 May.
Artículo en Inglés | MEDLINE | ID: mdl-16251224

RESUMEN

OBJECTIVE: To show an overall diagnostic accuracy > or = 90% for detection of > or = 50% stenoses by coronary half millimetre 32 detector row computed tomography angiography (32 x 0.5-MDCTA) in patients with advanced coronary artery disease (CAD) and a high likelihood of raised calcium scores. METHODS: ECG gated 32 x 0.5-MDCTA (32 x 0.5 mm cross sections, 0.35 x 0.35 x 0.35 mm3 isotropic voxels, 400 ms rotation) was performed after injection of iodixanol (120 ml, 320 mg/ml) in 30 consecutive patients (25 men, mean (SD) age 59 (13) years, body mass index 26.2 (4.9) kg/m2). Native arteries, including > or = 1.5 mm branches, and bypass grafts were screened for > or = 50% stenoses. Stents were excluded. Conventional coronary angiography (performed 18 (12) days before 32 x 0.5-MDCTA) was analysed by quantitative coronary angiography. RESULTS: Median Agatston calcium score was 510 (range 3-5066). Sensitivity, specificity, and positive and negative predictive values for detection of > or = 50% stenoses in native arteries were 76% (29 of 38), 94% (190 of 202), 71% (29 of 41), and 96% (190 of 199), respectively. Overall diagnostic accuracy was 91% (219 of 240). Due to the following artefacts 20% (69 of 352) of the vessels were excluded: motion, noise, and low contrast enhancement isolated or in combination (45 of 69 (65%)); image distortion by implantable cardioverter-defibrillator or pacemaker leads (18 of 69 (26%)); and blooming secondary to severe calcification (6 of 69 (9%)). CONCLUSIONS: Coronary 32 x 0.5-MDCTA accurately excludes > or = 50% stenoses in patients with advanced CAD and high calcium scores with an overall diagnostic accuracy of 91%.


Asunto(s)
Cardiomiopatías/diagnóstico por imagen , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Artefactos , Calcinosis/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/normas
13.
Pacing Clin Electrophysiol ; 28(4): 336-8, 2005 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15826272

RESUMEN

The presence of pacemakers and implantable cardioverter-defibrillators (ICD) is considered historically a contraindication to magnetic resonance (MR) imaging. This image modality has unparalleled soft-tissue imaging capabilities, and many consider it as the image of choice for patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C). ICDs are now smaller, with less magnetic materials and improved electromagnetic interference protection. We tested modern ICDs for heat, force, function and image distortion and found that several of them may indeed be MRI safe. We report here a patient who was suspected of ARVD/C, underwent ICD implantation based on MR safety testing, and underwent intentionally scheduled follow-up cardiac MR imaging. This is the description of a patient with an ICD who had planned MRI scanning. The scan was safe and most of the MRI images were of high quality.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Seguridad de Equipos , Imagen por Resonancia Magnética , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Adulto , Humanos
14.
Circulation ; 110(6): 732-7, 2004 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-15289374

RESUMEN

BACKGROUND: MRI can identify patients with obstructive coronary artery disease by imaging the left ventricular myocardium during a first-pass contrast bolus in the presence and absence of pharmacologically induced myocardial hyperemia. The purpose of this multicenter dose-ranging study was to determine the minimally efficacious dose of gadopentetate dimeglumine injection (Magnevist Injection; Berlex Laboratories) for detecting obstructive coronary artery disease. METHOD AND RESULTS: A total of 99 patients scheduled for coronary artery catheterization as part of their clinical evaluation were enrolled in this study. Patients were randomized to 1 of 3 doses of gadopentate dimeglumine: 0.05, 0.10, or 0.15 mmol/kg. First-pass perfusion imaging was performed during hyperemia (induced by a 4-minute infusion of adenosine at a rate of 140 microg x kg(-1) x min(-1)) and then again in the absence of adenosine with otherwise identical imaging parameters and the same contrast dose. Perfusion defects were evaluated subjectively by 4 blinded reviewers. Receiver-operating curve analysis showed that the areas under the receiver-operating curve were 0.90, 0.72, and 0.83 for the low-, medium-, and high-contrast doses, respectively, compared with quantitative coronary angiography (diameter stenosis > or =70%). For the low-dose group, mean sensitivity was 93+/-0%, mean specificity was 75+/-7%, and mean accuracy was 85+/-3%. CONCLUSIONS: First-pass perfusion MRI is a safe and accurate test for identifying patients with obstructive coronary artery disease. A low dose of 0.05 mmol/kg gadopentetate dimeglumine is at least as efficacious as higher doses.


Asunto(s)
Circulación Coronaria , Enfermedad Coronaria/patología , Imagen por Resonancia Magnética/métodos , Miocardio/patología , Adenosina , Anciano , Área Bajo la Curva , Cateterismo Cardíaco , Medios de Contraste/administración & dosificación , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Relación Dosis-Respuesta a Droga , Reacciones Falso Positivas , Femenino , Gadolinio DTPA/administración & dosificación , Humanos , Hiperemia/inducido químicamente , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC , Sensibilidad y Especificidad , Método Simple Ciego
16.
J Am Coll Cardiol ; 38(7): 1859-65, 2001 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-11738285

RESUMEN

OBJECTIVES: We sought: 1) to investigate the relationship between vascular wall shear stress and flow-mediated dilation (FMD) in humans, and 2) to investigate whether this relationship could explain why FMD is greater in small arteries. BACKGROUND: Arterial wall shear stress (WSS) is considered to be the primary stimulus for the endothelial-dependent FMD response. However, the relationship between WSS and FMD has not been investigated in humans. Furthermore, FMD is greater in small arteries, though the reasons for this phenomenon are unclear. METHODS: Using phase-contrast magnetic resonance angiography (PMRCA), we measured hyperemic WSS and FMD in 18 healthy volunteers. Peak systolic WSS was calculated assuming a blunted parabolic velocity profile. Diameter by PCMRA and by ultrasound was compared in nine subjects. RESULTS: Flow-mediated dilation was linearly proportional to hyperemic peak systolic WSS (r = 0.79, p = 0.0001). Flow-mediated dilation was inversely related to baseline diameter (r = 0.62, p = 0.006), but the hyperemic peak WSS stimulus was also inversely related to baseline diameter (r = 0.47, p = 0.049). Phase-contrast magnetic resonance angiography and ultrasound diameters were compared in nine subjects and correlated well (r = 0.84, p < 0.0001), but diameter by PCMRA was greater (4.1 +/- 0.7 mm vs. 3.7 +/- 0.5 mm, p = 0.009). CONCLUSION: Arterial FMD is linearly proportional to peak hyperemic WSS in normal subjects. Thus, the endothelial response is linearly proportional to the stimulus. Furthermore, the greater FMD response in small arteries is accounted for, at least partially, by a greater hyperemic WSS stimulus in small arteries. By allowing the calculation of vascular WSS, which is the stimulus for FMD, and by imaging a fixed arterial cross-section, thus reducing operator dependence, PCMRA enhances the assessment of vascular endothelial function.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Endotelio Vascular/fisiopatología , Angiografía por Resonancia Magnética , Músculo Liso Vascular/fisiopatología , Vasodilatación/fisiología , Adulto , Femenino , Humanos , Hiperemia/fisiopatología , Masculino , Persona de Mediana Edad , Valores de Referencia , Sístole/fisiología
18.
Dis Colon Rectum ; 44(11): 1575-83; discussion 1583-4, 2001 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11711726

RESUMEN

PURPOSE: Pelvic organ prolapse results in a spectrum of progressively disabling disorders. Despite attempts to standardize the clinical examination, a variety of imaging techniques are used. The purpose of this study was to evaluate dynamic pelvic magnetic resonance imaging and dynamic cystocolpoproctography in the surgical management of females with complex pelvic floor disorders. METHODS: Twenty-two patients were identified from The Johns Hopkins Pelvic Floor Disorders Center database who had symptoms of complex pelvic organ prolapse and underwent dynamic magnetic resonance, dynamic cystocolpoproctography, and subsequent multidisciplinary review and operative repair. RESULTS: The mean age of the study group was 58 +/- 13 years, and all patients were Caucasian. Constipation (95.5 percent), urinary incontinence (77.3 percent), complaints of incomplete fecal evacuation (59.1 percent), and bulging vaginal tissues (54.4 percent) were the most common complaints on presentation. All patients had multiple complaints with a median number of 4 symptoms (range, 2-8). Physical examination, dynamic magnetic resonance imaging, and dynamic cystocolpoproctography were concordant for rectocele, enterocele, cystocele, and perineal descent in only 41 percent of patients. Dynamic imaging lead to changes in the initial operative plan in 41 percent of patients. Dynamic magnetic resonance was the only modality that identified levator ani hernias. Dynamic cystocolpoproctography identified sigmoidoceles and internal rectal prolapse more often than physical examination or dynamic magnetic resonance. CONCLUSIONS: Levator ani hernias are often missed by physical examination and traditional fluoroscopic imaging. Dynamic magnetic resonance and cystocolpoproctography are complementary studies to the physical examination that may alter the surgical management of females with complex pelvic floor disorders.


Asunto(s)
Colposcopía , Cistoscopía , Diafragma Pélvico/patología , Prolapso Uterino/cirugía , Adulto , Anciano , Canal Anal/patología , Estreñimiento/etiología , Estreñimiento/patología , Femenino , Hernia/diagnóstico , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Diafragma Pélvico/cirugía , Examen Físico , Estudios Prospectivos , Incontinencia Urinaria/etiología , Incontinencia Urinaria/patología , Prolapso Uterino/patología
19.
Int J Cardiovasc Imaging ; 17(4): 287-94; discussion 295-6, 2001 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-11599868

RESUMEN

A comparison between the prospective and retrospective respiratory navigator gating in MR coronary angiography was performed with eight normal subjects. A three-dimensional (3D) ECG-gated fast gradient echo pulse sequence was used for image data acquisition. The results show that the MR coronary angiography obtained using retrospective gating retains a considerable amount of motion artifacts. In this study, the images acquired using prospective navigator gating demonstrated significantly reduced motion artifacts (p = 0.009), improved vessel visibility (p = 0.021) with reduced imaging time (p = 0.013) compared to the images obtained using retrospective navigator gating.


Asunto(s)
Angiografía Coronaria , Angiografía por Resonancia Magnética/métodos , Movimiento (Física) , Músculos Respiratorios/diagnóstico por imagen , Músculos Respiratorios/fisiología , Adulto , Arterias/ultraestructura , Artefactos , Vasos Coronarios/ultraestructura , Humanos , Masculino , Estudios Prospectivos , Intensificación de Imagen Radiográfica , Valores de Referencia , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...