Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Bone Jt Open ; 4(11): 889-899, 2023 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-37992738

RESUMEN

Aims: To perform an incremental cost-utility analysis and assess the impact of differential costs and case volume on the cost-effectiveness of robotic arm-assisted unicompartmental knee arthroplasty (rUKA) compared to manual (mUKA). Methods: This was a five-year follow-up study of patients who were randomized to rUKA (n = 64) or mUKA (n = 65). Patients completed the EuroQol five-dimension questionnaire (EQ-5D) preoperatively, and at three months and one, two, and five years postoperatively, which was used to calculate quality-adjusted life years (QALYs) gained. Costs for the primary and additional surgery and healthcare costs were calculated. Results: rUKA was associated with a relative 0.012 QALY gain at five years, which was associated with an incremental cost per QALY of £13,078 for a unit undertaking 400 cases per year. A cost per QALY of less than £20,000 was achieved when ≥ 300 cases were performed per year. However, on removal of the cost for a revision for presumed infection (mUKA group, n = 1) the cost per QALY was greater than £38,000, which was in part due to the increased intraoperative consumable costs associated with rUKA (£626 per patient). When the absolute cost difference (operative and revision costs) was less than £240, a cost per QALY of less than £20,000 was achieved. On removing the cost of the revision for infection, rUKA was cost-neutral when more than 900 cases per year were undertaken and when the consumable costs were zero. Conclusion: rUKA was a cost-effective intervention with an incremental cost per QALY of £13,078 at five years, however when removing the revision for presumed infection, which was arguably a random event, this was no longer the case. The absolute cost difference had to be less than £240 to be cost-effective, which could be achieved by reducing the perioperative costs of rUKA or if there were increased revision costs associated with mUKA with longer follow-up.

2.
BMJ Open ; 13(6): e068255, 2023 06 09.
Artículo en Inglés | MEDLINE | ID: mdl-37295832

RESUMEN

INTRODUCTION: Robotic-assisted knee replacement systems have been introduced to healthcare services worldwide in an effort to improve clinical outcomes for people, although high-quality evidence that they are clinically, or cost-effective remains sparse. Robotic-arm systems may improve surgical accuracy and could contribute to reduced pain, improved function and lower overall cost of total knee replacement (TKR) surgery. However, TKR with conventional instruments may be just as effective and may be quicker and cheaper. There is a need for a robust evaluation of this technology, including cost-effectiveness analyses using both within-trial and modelling approaches. This trial will compare robotic-assisted against conventional TKR to provide high-quality evidence on whether robotic-assisted knee replacement is beneficial to patients and cost-effective for healthcare systems. METHODS AND ANALYSIS: The Robotic Arthroplasty Clinical and cost Effectiveness Randomised controlled trial-Knee is a multicentre, participant-assessor blinded, randomised controlled trial to evaluate the clinical and cost-effectiveness of robotic-assisted TKR compared with TKR using conventional instruments. A total of 332 participants will be randomised (1:1) to provide 90% power for a 12-point difference in the primary outcome measure; the Forgotten Joint Score at 12 months postrandomisation. Allocation concealment will be achieved using computer-based randomisation performed on the day of surgery and methods for blinding will include sham incisions for marker clusters and blinded operation notes. The primary analysis will adhere to the intention-to-treat principle. Results will be reported in line with the Consolidated Standards of Reporting Trials statement. A parallel study will collect data on the learning effects associated with robotic-arm systems. ETHICS AND DISSEMINATION: The trial has been approved by an ethics committee for patient participation (East Midlands-Nottingham 2 Research Ethics Committee, 29 July 2020. NRES number: 20/EM/0159). All results from the study will be disseminated using peer-reviewed publications, presentations at international conferences, lay summaries and social media as appropriate. TRIAL REGISTRATION NUMBER: ISRCTN27624068.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Procedimientos Quirúrgicos Robotizados , Humanos , Análisis de Costo-Efectividad , Articulación de la Rodilla , Artroplastia de Reemplazo de Rodilla/métodos , Dolor , Análisis Costo-Beneficio , Resultado del Tratamiento , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Multicéntricos como Asunto
3.
Int Orthop ; 47(7): 1765-1770, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37039819

RESUMEN

PURPOSE: This study was to evaluate the survivorship of HTO for the treatment of medial compartment osteoarthritis (OA) in young and active patients from two teaching hospitals in a single city. METHODS: This is a retrospective cohort multicenter study looking at HTO for treatment of medial compartment OA. We analyzed a case series of HTO's performed by four surgeons in two centres over a 14-year period. Failure was defined as conversion to total knee replacement (TKR). All cases where additional procedures for instability of the knee were performed at the time of the index surgery were excluded. Time to failure was recorded, and a Kaplan-Meir (KM) analysis was performed to evaluate survivorship. Univariate binary regression analysis was undertaken to identify associations between risk factors and failure. RESULTS: A total of 96 patients were included in the study with a median age was 45 years. The survivorship at five years post-op was 90.3%, and at ten years post-op, it was 82%. Patients that were 14 years after surgery had a survivorship of 65%. Also, 18.8% of patients required the removal of their metalwork. The overall complication rate was 6.3%. The univariate regression analysis showed that higher age (p = 0.02) and larger corrections requiring the use of bone graft increased the risk of failure (p = 0.02). There was no statistically significant correlation between laterality, gender, complication rate, and pre-operative alignment to survivorship. CONCLUSION: This is one of the largest reported case series of HTO's with comparable survivorship at five and ten year follow-up compared to the reported literature. There was an association found between increasing age and larger corrections requiring bone graft at index procedure to increasing failure rate.


Asunto(s)
Osteoartritis de la Rodilla , Humanos , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Osteoartritis de la Rodilla/etiología , Estudios Retrospectivos , Estudios de Seguimiento , Supervivencia , Tibia/cirugía , Articulación de la Rodilla/cirugía , Osteotomía/efectos adversos , Osteotomía/métodos , Resultado del Tratamiento
4.
Knee Surg Sports Traumatol Arthrosc ; 31(3): 751-759, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36166095

RESUMEN

PURPOSE: Computer-assisted surgery (CAS) total knee arthroplasty (TKA) remains a controversial area of surgical practice. The aim of this study is to report the ten-year revision rates and patient-reported outcome measures (PROMS) of a single-blinded, prospective, randomised controlled trial comparing electromagnetically (EM) navigated and conventional TKA. METHODS: 199 patients were randomised to receive either EM navigated or conventional TKA where the aim of implantation was neutral mechanical alignment in all cases. Ten-year revision rates were collated and compared between the two intervention groups. Longitudinal PROMS data was collected prospectively at various time points up to 10 years post-operatively. RESULTS: Over the ten-year period, there were 23 deaths (22.8%) in the EM navigation cohort and 30 deaths (30.6%) in the conventional cohort. At 10 years post-operatively, there was no statistically significant difference in all cause revision between the EM navigation and conventional cohort (4.0 vs 6.1%, p = 0.429). When analysing causes of revision that might be influenced by utilising EM navigation, there was no statistically significant difference in revisions (3.0% EM navigated vs 4.1% conventional group, p = 0.591). Patients that received navigated TKAs had improved Oxford Knee Society, American Knee Society Score and range of motion at 3 months following surgery compared to conventional TKA (p = 0.002, p = 0.032, and p = 0.05, respectively). However, from 1 to 10 years post-operatively, both interventions had equivalent outcomes. CONCLUSION: There is no difference in revision rates or clinical outcomes comparing EM navigated versus conventional TKA at ten-year follow-up. The expected mortality rate makes it unlikely that a difference in revision rates will reach statistical significance in the future. In the setting of an experienced knee arthroplasty surgeon, it is difficult to justify the additional costs of CAS in TKA surgery. LEVEL OF EVIDENCE: I.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Cirugía Asistida por Computador , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Estudios Prospectivos , Resultado del Tratamiento , Articulación de la Rodilla/cirugía , Cirugía Asistida por Computador/métodos , Osteoartritis de la Rodilla/cirugía
5.
Bone Joint Res ; 11(12): 890-892, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36513099

RESUMEN

Cite this article: Bone Joint Res 2022;11(12):890-892.

6.
Clin Anat ; 35(8): 1107-1113, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35668648

RESUMEN

The tip of the tibial tubercle (TTT) is used to assess tibial baseplate rotation in total knee arthroplasty (TKA); however, it can be difficult to palpate and visualize intraoperatively. Several more easily accessible soft-tissue structures have been proposed as intraoperative assessments, including the patellar tendon's medial border (MBPT) and the junction of the medial third of the patellar tendon (mt-PT). No studies have described the relationship between the TTT and these proposed landmarks. The aims of the study were to (1) determine the relationship of the soft-tissue landmarks to the TTT and (2) identify any sex differences in these measures. Measurements of the position of these soft-tissue landmarks relative to the TTT were made on 56 cadaveric knees (28 female) by two observers at the level of the standard tibial cut (10 mm distal to the lateral tibial plateau). The results obtained were compared by sex and side. On average, 50.7% (SD 6.79, range 33.1%-63.1%) of the patellar tendon footprint was medial to the TTT. There were no significant differences between the sexes or left and right lower limbs. However, there was large variability in the position of all the soft-tissue landmarks relative to the TTT. The results indicate that, on average, the patellar tendon footprint is evenly spread around the TTT. However, there is a large variability in the anatomical relationship between the soft-tissue landmarks and the TTT. Caution is advised if relying on these structures intraoperatively.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Artroplastia de Reemplazo de Rodilla/métodos , Cadáver , Femenino , Humanos , Articulación de la Rodilla/cirugía , Masculino , Rotación , Tibia/cirugía
7.
Bone Joint J ; 104-B(5): 541-548, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35491572

RESUMEN

AIMS: This systematic review aims to compare the precision of component positioning, patient-reported outcome measures (PROMs), complications, survivorship, cost-effectiveness, and learning curves of MAKO robotic arm-assisted unicompartmental knee arthroplasty (RAUKA) with manual medial unicompartmental knee arthroplasty (mUKA). METHODS: Searches of PubMed, MEDLINE, and Google Scholar were performed in November 2021 according to the Preferred Reporting Items for Systematic Review and Meta--Analysis statement. Search terms included "robotic", "unicompartmental", "knee", and "arthroplasty". Published clinical research articles reporting the learning curves and cost-effectiveness of MAKO RAUKA, and those comparing the component precision, functional outcomes, survivorship, or complications with mUKA, were included for analysis. RESULTS: A total of 179 articles were identified from initial screening, of which 14 articles satisfied the inclusion criteria and were included for analysis. The papers analyzed include one on learning curve, five on implant positioning, six on functional outcomes, five on complications, six on survivorship, and three on cost. The learning curve was six cases for operating time and zero for precision. There was consistent evidence of more precise implant positioning with MAKO RAUKA. Meta-analysis demonstrated lower overall complication rates associated with MAKO RAUKA (OR 2.18 (95% confidence interval (CI) 1.06 to 4.49); p = 0.040) but no difference in re-intervention, infection, Knee Society Score (KSS; mean difference 1.64 (95% CI -3.00 to 6.27); p = 0.490), or Western Ontario and McMaster Universities Arthritis Index (WOMAC) score (mean difference -0.58 (95% CI -3.55 to 2.38); p = 0.700). MAKO RAUKA was shown to be a cost-effective procedure, but this was directly related to volume. CONCLUSION: MAKO RAUKA was associated with improved precision of component positioning but was not associated with improved PROMs using the KSS and WOMAC scores. Future longer-term studies should report functional outcomes, potentially using scores with minimal ceiling effects and survival to assess whether the improved precision of MAKO RAUKA results in better outcomes. Cite this article: Bone Joint J 2022;104-B(5):541-548.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Procedimientos Quirúrgicos Robotizados , Artroplastia de Reemplazo de Rodilla/métodos , Humanos , Articulación de la Rodilla/cirugía , Curva de Aprendizaje , Ontario , Procedimientos Quirúrgicos Robotizados/métodos
8.
Bone Joint J ; 104-B(4): 433-443, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35360949

RESUMEN

AIMS: The aim of this study was to compare any differences in the primary outcome (biphasic flexion knee moment during gait) of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) at one year post-surgery. METHODS: A total of 76 patients (34 bi-UKA and 42 TKA patients) were analyzed in a prospective, single-centre, randomized controlled trial. Flat ground shod gait analysis was performed preoperatively and one year postoperatively. Knee flexion moment was calculated from motion capture markers and force plates. The same setup determined proprioception outcomes during a joint position sense test and one-leg standing. Surgery allocation, surgeon, and secondary outcomes were analyzed for prediction of the primary outcome from a binary regression model. RESULTS: Both interventions were shown to be effective treatment options, with no significant differences shown between interventions for the primary outcome of this study (18/35 (51.4%) biphasic TKA patients vs 20/31 (64.5%) biphasic bi-UKA patients; p = 0.558). All outcomes were compared to an age-matched, healthy cohort that outperformed both groups, indicating residual deficits exists following surgery. Logistic regression analysis of primary outcome with secondary outcomes indicated that the most significant predictor of postoperative biphasic knee moments was preoperative knee moment profile and trochlear degradation (Outerbridge) (R2 = 0.381; p = 0.002, p = 0.046). A separate regression of alignment against primary outcome indicated significant bi-UKA femoral and tibial axial alignment (R2 = 0.352; p = 0.029), and TKA femoral sagittal alignment (R2 = 0.252; p = 0.016). The bi-UKA group showed a significant increased ability in the proprioceptive joint position test, but no difference was found in more dynamic testing of proprioception. CONCLUSION: Robotic arm-assisted bi-UKA demonstrated equivalence to TKA in achieving a biphasic gait pattern after surgery for osteoarthritis of the knee. Both treatments are successful at improving gait, but both leave the patients with a functional limitation that is not present in healthy age-matched controls. Cite this article: Bone Joint J 2022;103-B(4):433-443.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Procedimientos Quirúrgicos Robotizados , Artroplastia de Reemplazo de Rodilla/efectos adversos , Humanos , Articulación de la Rodilla/cirugía , Estudios Prospectivos
9.
Surg Technol Int ; 40: 341-345, 2022 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-35325452

RESUMEN

INTRODUCTION: Rupture of the anterior cruciate ligament (ACL) often occurs in conjunction with meniscal tears. In this study, we investigate the rates and outcomes of meniscal repair surgery performed with ACL reconstruction compared with acute ACL repair surgery. MATERIALS AND METHODS: Data was collected for all patients undergoing surgery for ACL ruptures between 2012 and 2018, including ACL reconstruction with hamstring autograft and primary ACL repair augmented with suture tape. Patients undergoing multi-ligament surgery were excluded. Meniscal injury was evaluated intraoperatively and the treatment was determined by type of tear, reducibility, and quality of meniscal tissue. If possible, tears were repaired using all-inside anchors and all others were resected. RESULTS: There were 272 ACL reconstructions and 134 ACL repairs, and mean age was 28 (±9) and 35 (±14) years, respectively (p <0.01). The mean Tegner activity score was 6.6 in both groups. The mean interval from injury to surgery was longer in the reconstruction group (26.2 vs. 1.3 months, p <0.01). Fifty-five percent of reconstructions and 43% of ACL repairs required meniscal surgery at the time of their ACL procedure. In the reconstruction group, 123 (70%) were meniscectomies and 53 (30%) were meniscal repairs, compared to 31 (50%) of each in the ACL repair group. Meniscal repair was more likely to be possible when carried out as part of acute ACL repair surgery, c2(1, n=238)=7.94, p <0.01. The success rate of meniscal repair was 97% in both groups. CONCLUSIONS: The rate of meniscal repair is 67% higher when performed early with ACL repair. When ACL reconstruction is performed, meniscal resection was more likely. Rates of post-traumatic osteoarthritis are high after ACL reconstruction when performed with meniscal resection. Furthermore, the success rate of meniscal repair in conjunction with ACL surgery is high (97%). Therefore, meniscal repair should be encouraged whenever possible to improve long-term outcomes.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Reconstrucción del Ligamento Cruzado Anterior , Lesiones de Menisco Tibial , Adulto , Ligamento Cruzado Anterior/cirugía , Lesiones del Ligamento Cruzado Anterior/cirugía , Reconstrucción del Ligamento Cruzado Anterior/métodos , Humanos , Meniscos Tibiales/cirugía , Estudios Retrospectivos , Rotura/cirugía , Lesiones de Menisco Tibial/epidemiología , Lesiones de Menisco Tibial/cirugía
10.
Commun Biol ; 4(1): 1216, 2021 10 22.
Artículo en Inglés | MEDLINE | ID: mdl-34686772

RESUMEN

Fungi have evolved an array of spore discharge and dispersal processes. Here, we developed a theoretical model that explains the ejection mechanics of aeciospore liberation in the stem rust pathogen Puccinia graminis. Aeciospores are released from cluster cups formed on its Berberis host, spreading early-season inoculum into neighboring small-grain crops. Our model illustrates that during dew or rainfall, changes in aeciospore turgidity exerts substantial force on neighboring aeciospores in cluster cups whilst gaps between spores become perfused with water. This perfusion coats aeciospores with a lubrication film that facilitates expulsion, with single aeciospores reaching speeds of 0.053 to 0.754 m·s-1. We also used aeciospore source strength estimates to simulate the aeciospore dispersal gradient and incorporated this into a publicly available web interface. This aids farmers and legislators to assess current local risk of dispersal and facilitates development of sophisticated epidemiological models to potentially curtail stem rust epidemics originating on Berberis.


Asunto(s)
Humedad , Puccinia/fisiología , Esporas Fúngicas/fisiología
11.
Bone Joint J ; 103-B(10): 1561-1570, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34587803

RESUMEN

AIMS: The aim of this study was to compare the clinical outcomes of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) during the first six weeks and at one year postoperatively. METHODS: A per protocol analysis of 76 patients, 43 of whom underwent TKA and 34 of whom underwent bi-UKA, was performed from a prospective, single-centre, randomized controlled trial. Diaries kept by the patients recorded pain, function, and the use of analgesics daily throughout the first week and weekly between the second and sixth weeks. Patient-reported outcome measures (PROMs) were compared preoperatively, and at three months and one year postoperatively. Data were also compared longitudinally and a subgroup analysis was conducted, stratified by preoperative PROM status. RESULTS: Both operations were shown to offer comparable outcomes, with no significant differences between the groups across all timepoints and outcome measures. Both groups also had similarly low rates of complications. Subgroup analysis for preoperative psychological state, activity levels, and BMI showed no difference in outcomes between the two groups. CONCLUSION: Robotic arm-assisted, cruciate-sparing bi-UKA offered similar early clinical outcomes and rates of complications to a mechanically aligned TKA, both in the immediate postoperative period and up to one year following surgery. Further work is required to identify which patients with osteoarthritis of the knee will derive benefit from a cruciate-sparing bi-UKA. Cite this article: Bone Joint J 2021;103-B(10):1561-1570.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Hemiartroplastia/métodos , Osteoartritis de la Rodilla/cirugía , Procedimientos Quirúrgicos Robotizados/métodos , Anciano , Artroplastia de Reemplazo de Rodilla/instrumentación , Método Doble Ciego , Femenino , Estudios de Seguimiento , Marcha , Hemiartroplastia/instrumentación , Humanos , Análisis de Intención de Tratar , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Medición de Resultados Informados por el Paciente , Estudios Prospectivos , Resultado del Tratamiento
12.
Int Orthop ; 45(11): 2859-2867, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34392378

RESUMEN

PURPOSE: The NexGen Legacy Posterior Stabilised (LPS) prosthesis (Zimmer Biomet, Warsaw, IN, USA) has augmentable and non-augmentable tibial baseplate options. We have noted an anecdotal increase in the number of cases requiring early revision for aseptic loosening since adopting the non-augmentable option. The purpose of this study was to ascertain our rates of aseptic tibial loosening for the two implant types within five years of implantation and to investigate the causes for any difference observed. METHODS: A database search was performed for all patients who underwent primary total knee arthroplasty (TKA) using the NexGen LPS between 2009 and 2015. Kaplan-Meier curves were plotted to assess for differences in revision rates between cohorts. We collected and compared data on gender, age, body mass index, component alignment and cement mantle quality as these were factors thought to affect the likelihood of aseptic loosening. RESULTS: Two thousand one hundred seventy-two TKAs were included with five year follow-up. There were 759 augmentable knees of which 14 were revised and 1413 non-augmentable knees of which 48 were revised. The overall revision rate at five years was 1.84% in the augmentable cohort and 3.4% in the non-augmentable cohort. The revision rate for aseptic loosening was 0.26% in the augmentable group and 1.42% in the non-augmentable group (p = 0.0241). CONCLUSIONS: We have identified increased rates of aseptic loosening in non-augmentable components. This highlights the effect that minor implant changes can have on outcomes. We recommend that clinicians remain alert to implant changes and publish their own results when important trends are observed.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Artroplastia de Reemplazo de Rodilla/efectos adversos , Humanos , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla/efectos adversos , Diseño de Prótesis , Falla de Prótesis , Reoperación , Estudios Retrospectivos
13.
J Arthroplasty ; 36(10): 3451-3455, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34226082

RESUMEN

BACKGROUND: The objective of this study is to provide the 5-year follow-up results of a randomized study comparing conventional versus electromagnetic computer navigated total knee arthroplasty. METHODS: Analysis of 127 patients (66 navigated and 61 conventional surgeries) was performed from a prospective, single-blinded, randomized controlled trial. Patient-reported outcome measures were collected at 5 years after surgery and compared with previously published 1-year clinical outcomes. Five-year surgical revision rates were collated and compared between intervention groups. RESULTS: Overall, there have been continued improvements in the clinical scores of patients in both groups when compared with clinical data at 1 year; however, at 5 years, there is no statistical difference in any of the patient-reported outcome measures between conventional and navigated surgery. Interestingly, improved implant survivorship was observed in the navigated (0% revision rate) compared with the conventional group (4.9% all-cause revision rate). CONCLUSION: Electromagnetic computer navigated technology produces similar clinical outcomes compared with traditional surgery. Further work is required to monitor implant survivorship, and clinical outcomes with long-term follow-up, to determine the cost effectiveness of this technology.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Cirugía Asistida por Computador , Fenómenos Electromagnéticos , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Estudios Prospectivos , Falla de Prótesis , Método Simple Ciego , Resultado del Tratamiento
14.
Bone Joint J ; 103-B(6): 1088-1095, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34058870

RESUMEN

AIMS: Unicompartmental knee arthroplasty (UKA) is a bone-preserving treatment option for osteoarthritis localized to a single compartment in the knee. The success of the procedure is sensitive to patient selection and alignment errors. Robotic arm-assisted UKA provides technological assistance to intraoperative bony resection accuracy, which is thought to improve ligament balancing. This paper presents the five-year outcomes of a comparison between manual and robotically assisted UKAs. METHODS: The trial design was a prospective, randomized, parallel, single-centre study comparing surgical alignment in patients undergoing UKA for the treatment of medial compartment osteoarthritis (ISRCTN77119437). Participants underwent surgery using either robotic arm-assisted surgery or conventional manual instrumentation. The primary outcome measure (surgical accuracy) has previously been reported, and, along with secondary outcomes, were collected at one-, two-, and five-year timepoints. Analysis of five-year results and longitudinal analysis for all timepoints was performed to compare the two groups. RESULTS: Overall, 104 (80%) patients of the original 130 who received surgery were available at five years (55 robotic, 49 manual). Both procedures reported successful results over all outcomes. At five years, there were no statistical differences between the groups in any of the patient reported or clinical outcomes. There was a lower reintervention rate in the robotic arm-assisted group with 0% requiring further surgery compared with six (9%) of the manual group requiring additional surgical intervention (p < 0.001). CONCLUSION: This study has shown excellent clinical outcomes in both groups with no statistical or clinical differences in the patient-reported outcome measures. The notable difference was the lower reintervention rate at five years for roboticarm-assisted UKA when compared with a manual approach. Cite this article: Bone Joint J 2021;103-B(6):1088-1095.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Osteoartritis de la Rodilla/cirugía , Procedimientos Quirúrgicos Robotizados/métodos , Actividades Cotidianas , Adulto , Anciano , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Medición de Resultados Informados por el Paciente , Satisfacción del Paciente , Complicaciones Posoperatorias , Estudios Prospectivos , Rango del Movimiento Articular , Recuperación de la Función , Reoperación/estadística & datos numéricos
15.
Sci Rep ; 11(1): 11271, 2021 05 28.
Artículo en Inglés | MEDLINE | ID: mdl-34050237

RESUMEN

Thiamine diphosphate (TDP) and magnesium are co-factors for key enzymes in human intermediary metabolism. However, their role in the systemic inflammatory response (SIR) is not clear. Therefore, the aim of the present study was to examine the relation between acute changes in the SIR and thiamine and magnesium dependent enzyme activity in patients undergoing elective knee arthroplasty (a standard reproducible surgical injury in apparently healthy individuals). Patients (n = 35) who underwent elective total knee arthroplasty had venous blood samples collected pre- and post-operatively for 3 days, for measurement of whole blood TDP, serum and erythrocyte magnesium, erythrocyte transketolase activity (ETKA), lactate dehydrogenase (LDH), glucose and lactate concentrations. Pre-operatively, TDP concentrations, erythrocyte magnesium concentrations, ETKA and plasma glucose were within normal limits for all patients. In contrast, 5 patients (14%) had low serum magnesium concentrations (< 0.75 mmol/L). On post-operative day1, both TDP concentrations (p < 0.001) and basal ETKA (p < 0.05) increased and serum magnesium concentrations decreased (p < 0.001). Erythrocyte magnesium concentrations correlated with serum magnesium concentrations (rs = 0.338, p < 0.05) and remained constant during SIR. Post-operatively 14 patients (40%) had low serum magnesium concentrations. On day1 serum magnesium concentrations were directly associated with LDH (p < 0.05), WCC (p < 0.05) and neutrophils (p < 0.01). Whole blood TDP and basal ETKA increased while serum magnesium concentrations decreased, indicating increased requirement for thiamine and magnesium dependent enzyme activity during SIR. Therefore, thiamine and magnesium represent potentially modifiable therapeutic targets that may modulate the host inflammatory response. Erythrocyte magnesium concentrations are likely to be reliable measures of status, whereas serum magnesium concentrations and whole blood TDP may not.ClinicalTrials.gov: NCT03554668.


Asunto(s)
Inflamación/inmunología , Magnesio/metabolismo , Tiamina Pirofosfato/metabolismo , Adulto , Anciano , Artroplastia de Reemplazo de Rodilla/métodos , Procedimientos Quirúrgicos Electivos , Eritrocitos/metabolismo , Femenino , Humanos , Magnesio/sangre , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Tiamina/metabolismo , Tiamina Pirofosfato/sangre , Transcetolasa/metabolismo
16.
Bone Joint J ; 102-B(11): 1511-1518, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33135443

RESUMEN

AIMS: The aim of this study was to compare robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) in order to determine the changes in the anatomy of the knee and alignment of the lower limb following surgery. METHODS: An analysis of 38 patients who underwent TKA and 32 who underwent bi-UKA was performed as a secondary study from a prospective, single-centre, randomized controlled trial. CT imaging was used to measure coronal, sagittal, and axial alignment of the knee preoperatively and at three months postoperatively to determine changes in anatomy that had occurred as a result of the surgery. The hip-knee-ankle angle (HKAA) was also measured to identify any differences between the two groups. RESULTS: The pre- to postoperative changes in joint anatomy were significantly less in patients undergoing bi-UKA in all three planes in both the femur and tibia, except for femoral sagittal component orientation in which there was no difference. Overall, for the six parameters of alignment (three femoral and three tibial), 47% of bi-UKAs and 24% TKAs had a change of < 2° (p = 0.045). The change in HKAA towards neutral in varus and valgus knees was significantly less in patients undergoing bi-UKA compared with those undergoing TKA (p < 0.001). Alignment was neutral in those undergoing TKA (mean 179.5° (SD 3.2°)) while those undergoing bi-UKA had mild residual varus or valgus alignment (mean 177.8° (SD 3.4°)) (p < 0.001). CONCLUSION: Robotic-assisted, cruciate-sparing bi-UKA maintains the natural anatomy of the knee in the coronal, sagittal, and axial planes better, and may therefore preserve normal joint kinematics, compared with a mechanically aligned TKA. This includes preservation of coronal joint line obliquity. HKAA alignment was corrected towards neutral significantly less in patients undergoing bi-UKA, which may represent restoration of the pre-disease constitutional alignment (p < 0.001). Cite this article: Bone Joint J 2020;102-B(11):1511-1518.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla/cirugía , Procedimientos Quirúrgicos Robotizados , Anciano , Fenómenos Biomecánicos , Desviación Ósea/prevención & control , Femenino , Fémur/cirugía , Humanos , Articulación de la Rodilla/anatomía & histología , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Tibia/cirugía
17.
Ther Adv Musculoskelet Dis ; 12: 1759720X20943088, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32922524

RESUMEN

BACKGROUND: Topical diclofenac, a nonsteroidal anti-inflammatory drug, has proven efficacy and safety in the management of osteoarthritis pain. We investigated penetration of topical diclofenac into knee synovial tissue and fluid (primary objective) and evaluated relative exposure in the knee versus plasma (secondary objective). METHODS: In this phase I, double-blind, multicenter study, patients scheduled for arthroplasty for end-stage knee osteoarthritis were randomly assigned 2:1 to 4 g diclofenac diethylamine 2.32% w/w gel (92.8 mg diclofenac diethylamine, equivalent to 74.4 mg diclofenac, per application) or placebo gel, applied to the affected knee by a trained nurse/designee every 12 h for 7 days before surgery. Diclofenac concentrations were measured in synovial tissue, synovial fluid and plasma from samples obtained during surgery ⩾12 h after last application. Treatment-emergent adverse events (TEAEs) were evaluated. RESULTS: Evaluable synovial tissue or fluid samples were obtained from 45 (diclofenac n = 29; placebo n = 16) of 47 patients. All diclofenac-treated participants had measurable diclofenac concentrations in synovial tissue [geometric mean 1.57 (95% confidence interval (CI) 1.12, 2.20) ng/g] and fluid [geometric mean 2.27 (95% CI 1.87, 2.76) ng/ml] ⩾12 h after the last dose. Geometric mean (95% CI) ratio of diclofenac in synovial tissue:plasma was 0.32 (0.23, 0.45) and in synovial fluid:plasma was 0.46 (0.40, 0.54). TEAE rates were similar for diclofenac (55.2%) and placebo (58.8%); none were treatment related. CONCLUSIONS: Topical diclofenac diethylamine 2.32% w/w gel penetrated into the osteoarthritic knee after repeated application and remained detectable in synovial tissue and fluid at the end of the final 12 h dosing cycle.

18.
Scott Med J ; 65(3): 89-93, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32594896

RESUMEN

BACKGROUND AND AIMS: The aim of this large population based study was to investigate the effect of patient age and gender on the complication rates of knee arthroplasty surgery using data from the Scottish Arthroplasty Project joint registry. METHODS AND RESULTS: 55,636 knee arthroplasty procedures were included in the study and divided into four age categories (<55, 55-64, 65-75 and >75 years) for comparison of the 90-day deep vein thrombosis or pulmonary embolism (DVT/PE) and one-year infection rates and the mortality and revision rates up to ten-year follow up. The mean rate of DVT/PE was 1.4% with significantly higher rates in elderly patients (p = 0.0006). The mean one-year infection rate was 1.6% with a significantly increased rate of 1.9% in males (p = 0.0001). Mortality rates increased with age, the 10-year mortality in patients >75 years of age was 44.8%. Revision rates were increased in males and younger patients. CONCLUSION: Elderly patients showed higher rates of thromboembolic complications. There was no difference in infection rates between different age groups. The infection rate was higher in males. Younger patients need to be counselled about the increased risk of revision at 10 years.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/estadística & datos numéricos , Infección de la Herida Quirúrgica/epidemiología , Tromboembolia/epidemiología , Distribución por Edad , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Escocia/epidemiología , Distribución por Sexo , Tromboembolia/complicaciones
19.
Int J Pharm ; 584: 119408, 2020 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-32407942

RESUMEN

Using micro-sized channels to manipulate fluids is the essence of microfluidics which has wide applications from analytical chemistry to material science and cell biology research. Recently, using microfluidic-based devices for pharmaceutical research, in particular for the fabrication of micro- and nano-particles, has emerged as a new area of interest. The particles that can be prepared by microfluidic devices can range from micron size droplet-based emulsions to nano-sized drug loaded polymeric particles. Microfluidic technology poses unique advantages in terms of the high precision of the mixing regimes and control of fluids involved in formulation preparation. As a result of this, monodispersity of the particles prepared by microfluidics is often recognised as being a particularly advantageous feature in comparison to those prepared by conventional large-scale mixing methods. However, there is a range of practical drawbacks and challenges of using microfluidics as a direct micron- and nano-particle manufacturing method. Technological advances are still required before this type of processing can be translated for application by the pharmaceutical industry. This review focuses specifically on the application of microfluidics for pharmaceutical solid nanoparticle preparation and discusses the theoretical foundation of using the nanoprecipitation principle to generate particles and how this is translated into microfluidic design and operation.


Asunto(s)
Química Farmacéutica/métodos , Microfluídica/métodos , Nanopartículas/química , Dispositivos Laboratorio en un Chip , Tamaño de la Partícula
20.
Arthroplasty ; 2(1): 36, 2020 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-35236456

RESUMEN

BACKGROUND: CT scans can be used to assess the rotational alignment of the femoral component following total knee arthroplasty (TKA). This is done by calculating the posterior condylar angle (PCA). However, the methods used may not account for the biomechanical functionality of the TKA components. This cadaveric study aimed to determine whether the axis of scanning (mechanical or anatomical) alters the results of PCA calculations. METHODS: CT scans of 12 cadaveric adult femora were performed along the anatomical axis and the mechanical axis. The PCA was determined on each CT scan by measuring the relationship of the prosthetic posterior condyles to the surgical epicondylar axis of the femur. The mechanical and anatomical axis groups were further subdivided into best-fit and multi-slice subgroups. As a control, the posterior condylar angle was also calculated on photographic images of each femur. Bland-Altman plots were used to determine the correlation between the PCA values obtained from the different scanning axes and measurement techniques. RESULTS: There was no significant difference between the PCA measurements derived from anatomical and mechanical axis CT scans. The Pearson correlation co-efficient also indicated good correlation between the two scanning axes. CONCLUSION: The axis of scanning does not significantly affect the PCA measurements. Therefore, the measurements may be reliably used for clinical decision-making, regardless of the axis of CT scanning.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...