Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Bone Jt Open ; 4(11): 889-899, 2023 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-37992738

RESUMEN

Aims: To perform an incremental cost-utility analysis and assess the impact of differential costs and case volume on the cost-effectiveness of robotic arm-assisted unicompartmental knee arthroplasty (rUKA) compared to manual (mUKA). Methods: This was a five-year follow-up study of patients who were randomized to rUKA (n = 64) or mUKA (n = 65). Patients completed the EuroQol five-dimension questionnaire (EQ-5D) preoperatively, and at three months and one, two, and five years postoperatively, which was used to calculate quality-adjusted life years (QALYs) gained. Costs for the primary and additional surgery and healthcare costs were calculated. Results: rUKA was associated with a relative 0.012 QALY gain at five years, which was associated with an incremental cost per QALY of £13,078 for a unit undertaking 400 cases per year. A cost per QALY of less than £20,000 was achieved when ≥ 300 cases were performed per year. However, on removal of the cost for a revision for presumed infection (mUKA group, n = 1) the cost per QALY was greater than £38,000, which was in part due to the increased intraoperative consumable costs associated with rUKA (£626 per patient). When the absolute cost difference (operative and revision costs) was less than £240, a cost per QALY of less than £20,000 was achieved. On removing the cost of the revision for infection, rUKA was cost-neutral when more than 900 cases per year were undertaken and when the consumable costs were zero. Conclusion: rUKA was a cost-effective intervention with an incremental cost per QALY of £13,078 at five years, however when removing the revision for presumed infection, which was arguably a random event, this was no longer the case. The absolute cost difference had to be less than £240 to be cost-effective, which could be achieved by reducing the perioperative costs of rUKA or if there were increased revision costs associated with mUKA with longer follow-up.

2.
BMJ Open ; 13(6): e068255, 2023 06 09.
Artículo en Inglés | MEDLINE | ID: mdl-37295832

RESUMEN

INTRODUCTION: Robotic-assisted knee replacement systems have been introduced to healthcare services worldwide in an effort to improve clinical outcomes for people, although high-quality evidence that they are clinically, or cost-effective remains sparse. Robotic-arm systems may improve surgical accuracy and could contribute to reduced pain, improved function and lower overall cost of total knee replacement (TKR) surgery. However, TKR with conventional instruments may be just as effective and may be quicker and cheaper. There is a need for a robust evaluation of this technology, including cost-effectiveness analyses using both within-trial and modelling approaches. This trial will compare robotic-assisted against conventional TKR to provide high-quality evidence on whether robotic-assisted knee replacement is beneficial to patients and cost-effective for healthcare systems. METHODS AND ANALYSIS: The Robotic Arthroplasty Clinical and cost Effectiveness Randomised controlled trial-Knee is a multicentre, participant-assessor blinded, randomised controlled trial to evaluate the clinical and cost-effectiveness of robotic-assisted TKR compared with TKR using conventional instruments. A total of 332 participants will be randomised (1:1) to provide 90% power for a 12-point difference in the primary outcome measure; the Forgotten Joint Score at 12 months postrandomisation. Allocation concealment will be achieved using computer-based randomisation performed on the day of surgery and methods for blinding will include sham incisions for marker clusters and blinded operation notes. The primary analysis will adhere to the intention-to-treat principle. Results will be reported in line with the Consolidated Standards of Reporting Trials statement. A parallel study will collect data on the learning effects associated with robotic-arm systems. ETHICS AND DISSEMINATION: The trial has been approved by an ethics committee for patient participation (East Midlands-Nottingham 2 Research Ethics Committee, 29 July 2020. NRES number: 20/EM/0159). All results from the study will be disseminated using peer-reviewed publications, presentations at international conferences, lay summaries and social media as appropriate. TRIAL REGISTRATION NUMBER: ISRCTN27624068.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Procedimientos Quirúrgicos Robotizados , Humanos , Análisis de Costo-Efectividad , Articulación de la Rodilla , Artroplastia de Reemplazo de Rodilla/métodos , Dolor , Análisis Costo-Beneficio , Resultado del Tratamiento , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Multicéntricos como Asunto
3.
Knee Surg Sports Traumatol Arthrosc ; 31(3): 751-759, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36166095

RESUMEN

PURPOSE: Computer-assisted surgery (CAS) total knee arthroplasty (TKA) remains a controversial area of surgical practice. The aim of this study is to report the ten-year revision rates and patient-reported outcome measures (PROMS) of a single-blinded, prospective, randomised controlled trial comparing electromagnetically (EM) navigated and conventional TKA. METHODS: 199 patients were randomised to receive either EM navigated or conventional TKA where the aim of implantation was neutral mechanical alignment in all cases. Ten-year revision rates were collated and compared between the two intervention groups. Longitudinal PROMS data was collected prospectively at various time points up to 10 years post-operatively. RESULTS: Over the ten-year period, there were 23 deaths (22.8%) in the EM navigation cohort and 30 deaths (30.6%) in the conventional cohort. At 10 years post-operatively, there was no statistically significant difference in all cause revision between the EM navigation and conventional cohort (4.0 vs 6.1%, p = 0.429). When analysing causes of revision that might be influenced by utilising EM navigation, there was no statistically significant difference in revisions (3.0% EM navigated vs 4.1% conventional group, p = 0.591). Patients that received navigated TKAs had improved Oxford Knee Society, American Knee Society Score and range of motion at 3 months following surgery compared to conventional TKA (p = 0.002, p = 0.032, and p = 0.05, respectively). However, from 1 to 10 years post-operatively, both interventions had equivalent outcomes. CONCLUSION: There is no difference in revision rates or clinical outcomes comparing EM navigated versus conventional TKA at ten-year follow-up. The expected mortality rate makes it unlikely that a difference in revision rates will reach statistical significance in the future. In the setting of an experienced knee arthroplasty surgeon, it is difficult to justify the additional costs of CAS in TKA surgery. LEVEL OF EVIDENCE: I.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Cirugía Asistida por Computador , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Estudios Prospectivos , Resultado del Tratamiento , Articulación de la Rodilla/cirugía , Cirugía Asistida por Computador/métodos , Osteoartritis de la Rodilla/cirugía
4.
Bone Joint Res ; 11(12): 890-892, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36513099

RESUMEN

Cite this article: Bone Joint Res 2022;11(12):890-892.

5.
Bone Joint J ; 104-B(5): 541-548, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35491572

RESUMEN

AIMS: This systematic review aims to compare the precision of component positioning, patient-reported outcome measures (PROMs), complications, survivorship, cost-effectiveness, and learning curves of MAKO robotic arm-assisted unicompartmental knee arthroplasty (RAUKA) with manual medial unicompartmental knee arthroplasty (mUKA). METHODS: Searches of PubMed, MEDLINE, and Google Scholar were performed in November 2021 according to the Preferred Reporting Items for Systematic Review and Meta--Analysis statement. Search terms included "robotic", "unicompartmental", "knee", and "arthroplasty". Published clinical research articles reporting the learning curves and cost-effectiveness of MAKO RAUKA, and those comparing the component precision, functional outcomes, survivorship, or complications with mUKA, were included for analysis. RESULTS: A total of 179 articles were identified from initial screening, of which 14 articles satisfied the inclusion criteria and were included for analysis. The papers analyzed include one on learning curve, five on implant positioning, six on functional outcomes, five on complications, six on survivorship, and three on cost. The learning curve was six cases for operating time and zero for precision. There was consistent evidence of more precise implant positioning with MAKO RAUKA. Meta-analysis demonstrated lower overall complication rates associated with MAKO RAUKA (OR 2.18 (95% confidence interval (CI) 1.06 to 4.49); p = 0.040) but no difference in re-intervention, infection, Knee Society Score (KSS; mean difference 1.64 (95% CI -3.00 to 6.27); p = 0.490), or Western Ontario and McMaster Universities Arthritis Index (WOMAC) score (mean difference -0.58 (95% CI -3.55 to 2.38); p = 0.700). MAKO RAUKA was shown to be a cost-effective procedure, but this was directly related to volume. CONCLUSION: MAKO RAUKA was associated with improved precision of component positioning but was not associated with improved PROMs using the KSS and WOMAC scores. Future longer-term studies should report functional outcomes, potentially using scores with minimal ceiling effects and survival to assess whether the improved precision of MAKO RAUKA results in better outcomes. Cite this article: Bone Joint J 2022;104-B(5):541-548.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Procedimientos Quirúrgicos Robotizados , Artroplastia de Reemplazo de Rodilla/métodos , Humanos , Articulación de la Rodilla/cirugía , Curva de Aprendizaje , Ontario , Procedimientos Quirúrgicos Robotizados/métodos
6.
Bone Joint J ; 104-B(4): 433-443, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35360949

RESUMEN

AIMS: The aim of this study was to compare any differences in the primary outcome (biphasic flexion knee moment during gait) of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) at one year post-surgery. METHODS: A total of 76 patients (34 bi-UKA and 42 TKA patients) were analyzed in a prospective, single-centre, randomized controlled trial. Flat ground shod gait analysis was performed preoperatively and one year postoperatively. Knee flexion moment was calculated from motion capture markers and force plates. The same setup determined proprioception outcomes during a joint position sense test and one-leg standing. Surgery allocation, surgeon, and secondary outcomes were analyzed for prediction of the primary outcome from a binary regression model. RESULTS: Both interventions were shown to be effective treatment options, with no significant differences shown between interventions for the primary outcome of this study (18/35 (51.4%) biphasic TKA patients vs 20/31 (64.5%) biphasic bi-UKA patients; p = 0.558). All outcomes were compared to an age-matched, healthy cohort that outperformed both groups, indicating residual deficits exists following surgery. Logistic regression analysis of primary outcome with secondary outcomes indicated that the most significant predictor of postoperative biphasic knee moments was preoperative knee moment profile and trochlear degradation (Outerbridge) (R2 = 0.381; p = 0.002, p = 0.046). A separate regression of alignment against primary outcome indicated significant bi-UKA femoral and tibial axial alignment (R2 = 0.352; p = 0.029), and TKA femoral sagittal alignment (R2 = 0.252; p = 0.016). The bi-UKA group showed a significant increased ability in the proprioceptive joint position test, but no difference was found in more dynamic testing of proprioception. CONCLUSION: Robotic arm-assisted bi-UKA demonstrated equivalence to TKA in achieving a biphasic gait pattern after surgery for osteoarthritis of the knee. Both treatments are successful at improving gait, but both leave the patients with a functional limitation that is not present in healthy age-matched controls. Cite this article: Bone Joint J 2022;103-B(4):433-443.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Procedimientos Quirúrgicos Robotizados , Artroplastia de Reemplazo de Rodilla/efectos adversos , Humanos , Articulación de la Rodilla/cirugía , Estudios Prospectivos
7.
Surg Technol Int ; 40: 341-345, 2022 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-35325452

RESUMEN

INTRODUCTION: Rupture of the anterior cruciate ligament (ACL) often occurs in conjunction with meniscal tears. In this study, we investigate the rates and outcomes of meniscal repair surgery performed with ACL reconstruction compared with acute ACL repair surgery. MATERIALS AND METHODS: Data was collected for all patients undergoing surgery for ACL ruptures between 2012 and 2018, including ACL reconstruction with hamstring autograft and primary ACL repair augmented with suture tape. Patients undergoing multi-ligament surgery were excluded. Meniscal injury was evaluated intraoperatively and the treatment was determined by type of tear, reducibility, and quality of meniscal tissue. If possible, tears were repaired using all-inside anchors and all others were resected. RESULTS: There were 272 ACL reconstructions and 134 ACL repairs, and mean age was 28 (±9) and 35 (±14) years, respectively (p <0.01). The mean Tegner activity score was 6.6 in both groups. The mean interval from injury to surgery was longer in the reconstruction group (26.2 vs. 1.3 months, p <0.01). Fifty-five percent of reconstructions and 43% of ACL repairs required meniscal surgery at the time of their ACL procedure. In the reconstruction group, 123 (70%) were meniscectomies and 53 (30%) were meniscal repairs, compared to 31 (50%) of each in the ACL repair group. Meniscal repair was more likely to be possible when carried out as part of acute ACL repair surgery, c2(1, n=238)=7.94, p <0.01. The success rate of meniscal repair was 97% in both groups. CONCLUSIONS: The rate of meniscal repair is 67% higher when performed early with ACL repair. When ACL reconstruction is performed, meniscal resection was more likely. Rates of post-traumatic osteoarthritis are high after ACL reconstruction when performed with meniscal resection. Furthermore, the success rate of meniscal repair in conjunction with ACL surgery is high (97%). Therefore, meniscal repair should be encouraged whenever possible to improve long-term outcomes.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Reconstrucción del Ligamento Cruzado Anterior , Lesiones de Menisco Tibial , Adulto , Ligamento Cruzado Anterior/cirugía , Lesiones del Ligamento Cruzado Anterior/cirugía , Reconstrucción del Ligamento Cruzado Anterior/métodos , Humanos , Meniscos Tibiales/cirugía , Estudios Retrospectivos , Rotura/cirugía , Lesiones de Menisco Tibial/epidemiología , Lesiones de Menisco Tibial/cirugía
8.
Bone Joint J ; 103-B(10): 1561-1570, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34587803

RESUMEN

AIMS: The aim of this study was to compare the clinical outcomes of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) during the first six weeks and at one year postoperatively. METHODS: A per protocol analysis of 76 patients, 43 of whom underwent TKA and 34 of whom underwent bi-UKA, was performed from a prospective, single-centre, randomized controlled trial. Diaries kept by the patients recorded pain, function, and the use of analgesics daily throughout the first week and weekly between the second and sixth weeks. Patient-reported outcome measures (PROMs) were compared preoperatively, and at three months and one year postoperatively. Data were also compared longitudinally and a subgroup analysis was conducted, stratified by preoperative PROM status. RESULTS: Both operations were shown to offer comparable outcomes, with no significant differences between the groups across all timepoints and outcome measures. Both groups also had similarly low rates of complications. Subgroup analysis for preoperative psychological state, activity levels, and BMI showed no difference in outcomes between the two groups. CONCLUSION: Robotic arm-assisted, cruciate-sparing bi-UKA offered similar early clinical outcomes and rates of complications to a mechanically aligned TKA, both in the immediate postoperative period and up to one year following surgery. Further work is required to identify which patients with osteoarthritis of the knee will derive benefit from a cruciate-sparing bi-UKA. Cite this article: Bone Joint J 2021;103-B(10):1561-1570.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Hemiartroplastia/métodos , Osteoartritis de la Rodilla/cirugía , Procedimientos Quirúrgicos Robotizados/métodos , Anciano , Artroplastia de Reemplazo de Rodilla/instrumentación , Método Doble Ciego , Femenino , Estudios de Seguimiento , Marcha , Hemiartroplastia/instrumentación , Humanos , Análisis de Intención de Tratar , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Medición de Resultados Informados por el Paciente , Estudios Prospectivos , Resultado del Tratamiento
9.
J Arthroplasty ; 36(10): 3451-3455, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34226082

RESUMEN

BACKGROUND: The objective of this study is to provide the 5-year follow-up results of a randomized study comparing conventional versus electromagnetic computer navigated total knee arthroplasty. METHODS: Analysis of 127 patients (66 navigated and 61 conventional surgeries) was performed from a prospective, single-blinded, randomized controlled trial. Patient-reported outcome measures were collected at 5 years after surgery and compared with previously published 1-year clinical outcomes. Five-year surgical revision rates were collated and compared between intervention groups. RESULTS: Overall, there have been continued improvements in the clinical scores of patients in both groups when compared with clinical data at 1 year; however, at 5 years, there is no statistical difference in any of the patient-reported outcome measures between conventional and navigated surgery. Interestingly, improved implant survivorship was observed in the navigated (0% revision rate) compared with the conventional group (4.9% all-cause revision rate). CONCLUSION: Electromagnetic computer navigated technology produces similar clinical outcomes compared with traditional surgery. Further work is required to monitor implant survivorship, and clinical outcomes with long-term follow-up, to determine the cost effectiveness of this technology.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Cirugía Asistida por Computador , Fenómenos Electromagnéticos , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Estudios Prospectivos , Falla de Prótesis , Método Simple Ciego , Resultado del Tratamiento
10.
Bone Joint J ; 103-B(6): 1088-1095, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34058870

RESUMEN

AIMS: Unicompartmental knee arthroplasty (UKA) is a bone-preserving treatment option for osteoarthritis localized to a single compartment in the knee. The success of the procedure is sensitive to patient selection and alignment errors. Robotic arm-assisted UKA provides technological assistance to intraoperative bony resection accuracy, which is thought to improve ligament balancing. This paper presents the five-year outcomes of a comparison between manual and robotically assisted UKAs. METHODS: The trial design was a prospective, randomized, parallel, single-centre study comparing surgical alignment in patients undergoing UKA for the treatment of medial compartment osteoarthritis (ISRCTN77119437). Participants underwent surgery using either robotic arm-assisted surgery or conventional manual instrumentation. The primary outcome measure (surgical accuracy) has previously been reported, and, along with secondary outcomes, were collected at one-, two-, and five-year timepoints. Analysis of five-year results and longitudinal analysis for all timepoints was performed to compare the two groups. RESULTS: Overall, 104 (80%) patients of the original 130 who received surgery were available at five years (55 robotic, 49 manual). Both procedures reported successful results over all outcomes. At five years, there were no statistical differences between the groups in any of the patient reported or clinical outcomes. There was a lower reintervention rate in the robotic arm-assisted group with 0% requiring further surgery compared with six (9%) of the manual group requiring additional surgical intervention (p < 0.001). CONCLUSION: This study has shown excellent clinical outcomes in both groups with no statistical or clinical differences in the patient-reported outcome measures. The notable difference was the lower reintervention rate at five years for roboticarm-assisted UKA when compared with a manual approach. Cite this article: Bone Joint J 2021;103-B(6):1088-1095.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Osteoartritis de la Rodilla/cirugía , Procedimientos Quirúrgicos Robotizados/métodos , Actividades Cotidianas , Adulto , Anciano , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Medición de Resultados Informados por el Paciente , Satisfacción del Paciente , Complicaciones Posoperatorias , Estudios Prospectivos , Rango del Movimiento Articular , Recuperación de la Función , Reoperación/estadística & datos numéricos
11.
Bone Joint J ; 102-B(11): 1511-1518, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33135443

RESUMEN

AIMS: The aim of this study was to compare robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) in order to determine the changes in the anatomy of the knee and alignment of the lower limb following surgery. METHODS: An analysis of 38 patients who underwent TKA and 32 who underwent bi-UKA was performed as a secondary study from a prospective, single-centre, randomized controlled trial. CT imaging was used to measure coronal, sagittal, and axial alignment of the knee preoperatively and at three months postoperatively to determine changes in anatomy that had occurred as a result of the surgery. The hip-knee-ankle angle (HKAA) was also measured to identify any differences between the two groups. RESULTS: The pre- to postoperative changes in joint anatomy were significantly less in patients undergoing bi-UKA in all three planes in both the femur and tibia, except for femoral sagittal component orientation in which there was no difference. Overall, for the six parameters of alignment (three femoral and three tibial), 47% of bi-UKAs and 24% TKAs had a change of < 2° (p = 0.045). The change in HKAA towards neutral in varus and valgus knees was significantly less in patients undergoing bi-UKA compared with those undergoing TKA (p < 0.001). Alignment was neutral in those undergoing TKA (mean 179.5° (SD 3.2°)) while those undergoing bi-UKA had mild residual varus or valgus alignment (mean 177.8° (SD 3.4°)) (p < 0.001). CONCLUSION: Robotic-assisted, cruciate-sparing bi-UKA maintains the natural anatomy of the knee in the coronal, sagittal, and axial planes better, and may therefore preserve normal joint kinematics, compared with a mechanically aligned TKA. This includes preservation of coronal joint line obliquity. HKAA alignment was corrected towards neutral significantly less in patients undergoing bi-UKA, which may represent restoration of the pre-disease constitutional alignment (p < 0.001). Cite this article: Bone Joint J 2020;102-B(11):1511-1518.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla/cirugía , Procedimientos Quirúrgicos Robotizados , Anciano , Fenómenos Biomecánicos , Desviación Ósea/prevención & control , Femenino , Fémur/cirugía , Humanos , Articulación de la Rodilla/anatomía & histología , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Tibia/cirugía
12.
J Arthroplasty ; 33(7S): S109-S115, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29627257

RESUMEN

BACKGROUND: Unicompartmental knee arthroplasty (UKA) for treatment of medial compartment osteoarthritis has potential benefits over total knee arthroplasty but UKA has a higher revision rate. Robotic-assisted UKA is increasingly common and offers more accurate implant positioning and limb alignment, lower early postoperative pain but evidence of functional outcome is lacking. The aim was to assess the clinical outcomes of a single-centre, prospective, randomised controlled trial, comparing robotic-arm-assisted UKA with conventional surgery. METHODS: A total of 139 participants were recruited and underwent robotic-arm-assisted (fixed bearing) or conventional (mobile bearing) UKA. Fifty-eight patients in the robotic-arm-assisted group and 54 in the manual group at 2 years. The main outcome measures were the Oxford Knee Score, American Knee Society Score and revision rate. RESULTS: At 2 years, there were no significant differences for any of the outcome measures. Sub-group analysis (n = 35) of participants with a preoperative University of California Los Angeles Activity Scale >5 (more active) was performed. In this sub-group, the median Oxford Knee Score at 2 years was 46 (IQR 42.0-48.0) for robotic-arm-assisted and 41 (IQR 38.5-44.0) for the manual group (P = .036). The median American Knee Society Score was 193.5 (IQR 184.0-198.0) for the robotic-arm-assisted group and 174.0 (IQR 166.0-188.5) for the manual group (P = .017). Survivorship was 100% in robotic-arm-assisted group and 96.3% in the manual group. CONCLUSION: Overall, participants achieved an outcome equivalent to the most widely implanted UKA in the United Kingdom. Sub-group analysis suggests that more active patients may benefit from robotic-arm- assisted surgery. Long term follow-up is required to evaluate differences in survivorship.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Procedimientos Quirúrgicos Robotizados , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Dolor Postoperatorio/prevención & control , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Reino Unido
13.
Surg Technol Int ; 26: 239-55, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-26055016

RESUMEN

This article reviews the surgical decision-making considerations when preparing to undertake an anatomic ligament repair with augmentation using the InternalBrace™. Lateral ankle ligament stabilization of the Broström variety and ACL repair in particular are used to illustrate its application. The InternalBrace™ supports early mobilization of the repaired ligament and allows the natural tissues to progressively strengthen. The principle established by this experience has resulted in its successful application to other distal extremity ligaments including the deltoid, spring, and syndesmosis complex. Knee ligament augmentation with the InternalBrace™ has been successfully applied to all knee ligaments including anterior cruciate ligament (ACL), posterior cruciate ligament (PCL), medial collateral ligament (MCL), lateral collateral ligament (LCL), anterolateral ligament (ALL), and patellofemoral ligament (PFL). The surgical technique and early results will be reviewed including multi-ligament presentations. Upper limb experience with acromioclavicular (AC) joint augmentation and ulnar collateral ligament (UCL) repair of the elbow with the InternalBrace™ will also be discussed. This article points to a change in orthopaedic practice positioning reconstruction as a salvage procedure that has additional surgical morbidity and should be indicated only if the tissues fail to heal adequately after augmentation and repair.


Asunto(s)
Tobillo/cirugía , Ligamento Cruzado Anterior/cirugía , Procedimientos Ortopédicos/instrumentación , Procedimientos Ortopédicos/métodos , Procedimientos de Cirugía Plástica/métodos , Tirantes , Humanos , Dimensión del Dolor , Calidad de Vida , Rango del Movimiento Articular
14.
J Arthroplasty ; 30(2): 199-205, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25263246

RESUMEN

We report on the results of a randomized study (n=200) to compare total knee arthroplasty performed using conventional instrumentation or electromagnetic computer assisted surgical technique. 92% of navigated and 85% of conventional knees were implanted within ±3° from neutral mechanical alignment; there was no statistically significant difference between these proportions. There was also no difference in femoral or tibial rotation assessed by CT scan. At 1year follow up there was no statistical difference between the two groups in American Knee Society Score, Oxford Knee Scores, patient satisfaction, quality of life, hospital length of stay, complication rates or other adverse events. Tourniquet time in the navigated group was longer. Proving value for navigation in total knee arthroplasty surgery remains a challenge.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/cirugía , Cirugía Asistida por Computador , Adulto , Anciano , Anciano de 80 o más Años , Fenómenos Electromagnéticos , Femenino , Fémur/cirugía , Humanos , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Calidad de Vida , Rotación , Método Simple Ciego , Tibia/cirugía , Tomografía Computarizada por Rayos X
15.
Am J Sports Med ; 42(3): 716-22, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24458241

RESUMEN

BACKGROUND: The medial patellofemoral ligament (MPFL) is the main restraining force against lateral patellar displacement. It is disrupted after patellar subluxation or dislocation. Reconstruction of the MPFL is frequently performed when nonoperative management fails and the patient experiences recurrent patellar dislocation. PURPOSE: To determine the relationship between the degree of trochlear dysplasia and femoral tunnel position and outcome after MPFL reconstruction. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: A total of 68 patients (72 knees) with recurrent dislocation of the patella underwent MPFL reconstruction. The mean follow-up was 31.3 months (range, 13-72 months). Clinical and functional outcomes were recorded using the Kujala, Lysholm, and Tegner scores. Postoperative complications, participation in sporting activity, and overall patient satisfaction were determined. Radiographs were analyzed to evaluate congruence angle, lateral patellofemoral angle, patellar height, trochlear dysplasia, trochlear boss height, and position of the femoral tunnel. RESULTS: The mean Kujala, Lysholm, and Tegner scores postoperatively were 76.2, 73.8, and 3.6, respectively (n = 61). The mean congruence angle (n = 30) improved from 22.5° to 1.0° postoperatively (P = .000038), the lateral patellofemoral angle (n = 30) improved from 7.4° to 7.8° postoperatively (P = .048), and the patellar height (n = 46) using the Caton-Deschamps method improved from 1.1 to 1.0 postoperatively (P = .000016). Mild trochlear dysplasia grade A/B was found in 89% of patients (n = 54), and 11% of patients (n = 7) had severe grade C/D dysplasia. The mean distance from the anatomic insertion of the MPFL to the center of the tunnel was 9.3 mm (range, 0.5-28.2 mm), with 71.7% thought to be within 10 mm of the anatomic position defined by Schottle (n = 46). When patients with high-grade trochlear dysplasia were excluded, anatomically placed femoral tunnels demonstrated significantly better clinical scores than did tunnels not placed anatomically (Kujala score, P = .028; Lysholm score, P = .012). A multivariate logistic regression analysis also demonstrated that the distance of the femoral tunnel from the anatomic position predicted clinical outcome (Kujala score, P = .043; Lysholm score, P = .028). All of the patients with severe trochlear dysplasia (n = 7) suffered from recurrent dislocations postoperatively, compared with only 9.3% of patients (n = 5) with mild trochlear dysplasia (P = .0001). Four patients had patellar fractures postoperatively. Of patients with mild dysplasia, 83% were either very satisfied or satisfied with the outcome of their surgery compared with only 57% with severe dysplasia (P = .05). Of patients with mild trochlear dysplasia, 56% returned to sport postoperatively compared with only 43% of patients with severe trochlear dysplasia (P = .526). CONCLUSION: This study demonstrates the importance of restoration of the anatomic insertion point of the MPFL when performing MPFL reconstruction and proposes that this procedure should not be performed in isolation in patients with high-grade trochlear dysplasia.


Asunto(s)
Fémur/cirugía , Ligamentos Articulares/cirugía , Osteotomía/métodos , Luxación de la Rótula/cirugía , Articulación Patelofemoral/diagnóstico por imagen , Articulación Patelofemoral/cirugía , Adolescente , Adulto , Femenino , Estudios de Seguimiento , Fracturas Óseas/etiología , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Rótula/lesiones , Luxación de la Rótula/prevención & control , Satisfacción del Paciente , Complicaciones Posoperatorias , Radiografía , Recuperación de la Función , Estudios Retrospectivos , Prevención Secundaria , Tendones/trasplante , Tibia/cirugía , Adulto Joven
16.
Orthopedics ; 35(6): e945-9, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22691672

RESUMEN

The association between hip fracture and reduced bone mineral density is well documented, with reduced bone mineral density predisposing to fracture. However, it is unknown whether an association exists between the magnitude of bone density lost and the severity of the hip fracture sustained. One hundred forty-two patients (96 women, 46 men) with a mean age of 74 years (range, 49-92 years) who sustained a hip fracture following a simple ground-level fall and were treated for this injury were reviewed. All patients had undergone dual-energy x-ray absorptiometry bone scanning of the contralateral hip and lumbar spine. Fractures were classified as intra- or extracapsular or subtrochanteric and then subclassified by degree of severity as simple (stable) or multifragmentary (unstable) fracture patterns.Although a low hip bone mineral density (T- or Z score <2.5) was associated with an increased risk of extracapsular fracture (P=.025) compared with other fracture types, no association existed between bone mineral density and the severity of the resultant hip fracture. Although an association exists between bone mineral density and the risk of fragility fractures, the results of the current study suggest that the severity of hip fractures does not follow this correlation. Therefore, no assumption can be made about bone mineral density of the proximal femur based on the severity of the fracture observed on plain radiographs.


Asunto(s)
Densidad Ósea , Fracturas de Cadera/diagnóstico , Fracturas de Cadera/fisiopatología , Índices de Gravedad del Trauma , Anciano , Anciano de 80 o más Años , Femenino , Fracturas de Cadera/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Reino Unido
17.
Knee ; 17(3): 187-90, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19740664

RESUMEN

Anterior knee pain following primary total knee arthroplasty is common and can be difficult to treat satisfactorily. We reviewed 28 consecutive patients (29 knees) who underwent secondary resurfacing of the patella for persistent anterior knee pain and report on the results. Mean follow-up was 28 months (range 12-61) with no cases lost to follow-up. Oxford knee scores, range of motion, the patient's assessment of outcome and overall satisfaction were recorded. Seventeen out of 19 (59%) felt their knee was better following patellar resurfacing, 10 out of 29 (34%) felt it was the same and two out of 29 (7%) felt it was worse. There was a significant improvement in Oxford knee scores (p<0.001) and significant increase in patient satisfaction (p<0.001) following secondary resurfacing. While secondary resurfacing of the patella does not provide the solution for every case of anterior knee pain following total knee joint replacement, in greater than 50% of cases it can be effective at relieving symptoms and in this series carries a low risk of worsening symptoms or complications.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Dolor/etiología , Dolor/cirugía , Rótula/cirugía , Satisfacción del Paciente , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Osteotomía , Rango del Movimiento Articular , Reoperación , Estudios Retrospectivos
18.
Knee Surg Sports Traumatol Arthrosc ; 11(4): 204-11, 2003 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-12761610

RESUMEN

We present medium-term results in 30 prospectively followed patients aged over 50 years at the time of ACL reconstruction (31 procedures); mean follow-up time was 46 months (range 24-95). Mean Lysholm score improved significantly from 63 pre-operatively to 93 at final review Cincinnati score from 49 to 89. In IKDC score 25 knees (81%) were considered normal or nearly normal and 6 abnormal; there were no severely abnormal results. Mean Tegner activity scores improved from pre-operatively from 3.7 to 5.2 at review. Mean side-to-side difference measured by the KT-1000 at maximal manual pressure was 2.7 mm; two knees had. a measured difference greater than 5 mm. The mean torque ratio for isokinetic flexion strength was 102% and for extension strength 94%. Poor results as determined by the three scoring systems were associated mainly with advanced articular degenerative changes (Outerbridge grade 3 or 4) seen at the time of reconstruction. Despite this all patients reported improvement in stability and overall function of the knee. Degenerative change itself was associated with increased time to surgery from injury. This study demonstrates that the ACL can be reliably reconstructed in patients over the age of 50 years with good symptomatic relief, restoration of function and return to sporting activity.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Traumatismos de la Rodilla/cirugía , Femenino , Estudios de Seguimiento , Humanos , Traumatismos de la Rodilla/fisiopatología , Ligamentos Articulares/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Rango del Movimiento Articular , Reoperación , Rotura , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...