1.
Artículo en Inglés | MEDLINE | ID: mdl-38752961

RESUMEN

BACKGROUND: The extravascular (EV) implantable cardioverter-defibrillator (ICD) includes features to address sensing and arrhythmia detection challenges presented by its substernal lead location. OBJECTIVES: In this study, the authors sought to evaluate sensing and detection performance in 299 patients discharged with an EV-ICD in the global pivotal study. METHODS: We reviewed and adjudicated all induced ventricular fibrillation (VF) episodes and spontaneous device-stored episodes that satisfied rate and duration criteria in a programmed ventricular tachycardia (VT)/VF therapy zone. RESULTS: At implantation, all EV-ICDs detected induced VF at the programmed sensitivity; 95.9% detected VF with a 3× safety margin. In follow-up, EV-ICDs detected all 59 VT/VF episodes that sustained until therapy. Of 1,034 non-VT/VF episodes, oversensing caused 87.9% and supraventricular tachycardia caused 12.1%. Therapy was withheld in 80.9%, aborted in 10.6%, and delivered in 8.5%. The most common causes of oversensing were myopotentials (61.2%) and P-wave oversensing (PWOS) (19.9%). Inappropriate shocks occurred in only 3.2% of myopotential episodes, but in 21.8% of PWOS episodes. Myopotential oversensing was more common with Ring-Can sensing (P < 0.0001) and correlated with low R-wave amplitude (P < 0.0001). PWOS occurred almost exclusively with Ring1-Ring2 sensing (P = 0.0001) and began with transient decrease in R-wave or increase in P-wave amplitude (P < 0.0001). In software emulation, a new PWOS discriminator significantly reduced total inappropriate detections. CONCLUSIONS: In a global population, EV-ICD detected induced and spontaneous VT/VF accurately. Although discriminators withheld detection from most non-VT/VF episodes, inappropriate shocks were common. The most common cause was PWOS, which may be reduced by optimizing sensing at implantation and incorporation of the PWOS discriminator, which is now in the current device. (Extravascular ICD Pivotal Study [EV ICD]; NCT04060680).

2.
N Engl J Med ; 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38767244

RESUMEN

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown. METHODS: We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%). RESULTS: We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure. CONCLUSIONS: The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).

3.
Artículo en Inglés | MEDLINE | ID: mdl-38795093

RESUMEN

BACKGROUND: Left atrial appendage occlusion (LAAO) provides mechanical cardioembolic protection for atrial fibrillation (AF) patients who cannot use oral anticoagulation therapy (OAT). Patients with a thrombotic event despite OAT are at high risk for recurrence and may also benefit from LAAO. OBJECTIVES: This study sought to investigate the efficacy of LAAO in AF patients with a thrombotic event on OAT compared to: 1) LAAO in AF patients with a contraindication for OAT; and 2) historical data. METHODS: The international LAAO after stroke despite oral anticoagulation (STR-OAC LAAO) collaboration included patients who underwent LAAO because of thrombotic events on OAT. This cohort underwent propensity score matching and was compared to the EWOLUTION (Evaluating Real-Life Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology) registry, which represents patients who underwent LAAO because of OAT contraindications. The primary outcome was ischemic stroke. Event rates were compared between cohorts and with historical data without OAT, yielding relative risk reductions based on risk scores. RESULTS: Analysis of 438 matched pairs revealed no significant difference in the ischemic stroke rate between the STR-OAC LAAO and EWOLUTION cohorts (2.5% vs 1.9%; HR: 1.37; 95% CI: 0.72-2.61). STR-OAC LAAO patients exhibited a higher thromboembolic risk (HR: 1.71; 95% CI: 1.04-2.83) but lower bleeding risk (HR: 0.39; 95% CI: 0.18-0.88) compared to EWOLUTION patients. The mortality rate was slightly higher in EWOLUTION (4.3% vs 6.9%; log-rank P = 0.028). Relative risk reductions for ischemic stroke were 70% and 78% in STR-OAC LAAO and EWOLUTION, respectively, compared to historical data without OAT. CONCLUSIONS: LAAO in patients with a thrombotic event on OAT demonstrated comparable stroke rates to the OAT contraindicated population in EWOLUTION. The thromboembolic event rate was higher and the bleeding rate lower, reflecting the intrinsically different risk profile of both populations. Until randomized trials are available, LAAO may be considered in patients with an ischemic event on OAT.

4.
J Am Heart Assoc ; 13(8): e032033, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38591264

RESUMEN

BACKGROUND: Chronic total coronary occlusions (CTO) substantially increase the risk for sudden cardiac death. Among patients with chronic ischemic heart disease at risk for sudden cardiac death, an implantable cardioverter defibrillator (ICD) is the favored therapy for primary prevention of sudden cardiac death. This study sought to investigate the impact of CTOs on the risk for appropriate ICD shocks and mortality within a nationwide prospective cohort. METHODS AND RESULTS: This is a subanalysis of the nationwide Dutch-Outcome in ICD Therapy (DO-IT) registry of primary prevention ICD recipients in The Netherlands between September 2014 and June 2016 (n=1442). We identified patients with chronic ischemic heart disease (n=663) and assessed available coronary angiograms for CTO presence (n=415). Patients with revascularized CTOs were excluded (n=79). The primary end point was the composite of all-cause mortality and appropriate ICD shocks. Clinical follow-up was conducted for at least 2 years. A total of 336 patients were included, with an average age of 67±9 years, and 20.5% was female (n=69). An unrevascularized CTO was identified in 110 patients (32.7%). During a median follow-up period of 27 months (interquartile range, 24-32), the primary end point occurred in 21.1% of patients with CTO (n=23) compared with 11.9% in patients without CTO (n=27; P=0.034). Corrected for baseline characteristics including left ventricular ejection fraction, and the presence of a CTO was an independent predictor for the primary end point (hazard ratio, 1.82 [95% CI, 1.03-3.22]; P=0.038). CONCLUSIONS: Within this nationwide prospective registry of primary prevention ICD recipients, the presence of an unrevascularized CTO was an independent predictor for the composite outcome of all-cause mortality and appropriate ICD shocks.


Asunto(s)
Oclusión Coronaria , Desfibriladores Implantables , Humanos , Femenino , Persona de Mediana Edad , Anciano , Oclusión Coronaria/complicaciones , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/terapia , Arritmias Cardíacas , Desfibriladores Implantables/efectos adversos , Volumen Sistólico , Incidencia , Función Ventricular Izquierda , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Sistema de Registros , Factores de Riesgo
5.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38582974

RESUMEN

AIMS: The ultra-low-temperature cryoablation (ULTC) ablation system using -196°C N2 cryogen has been reported to create lesions with freeze duration-dependent depth titratable to over 10 mm with minimum attenuation by scar. Cryocure-VT (NCT04893317) was a first-in-human clinical trial evaluating the safety and efficacy of a novel, purpose-built ULTC catheter in endocardial ablation of scar-dependent ventricular tachycardias (VTs). METHODS AND RESULTS: This prospective, multi-centre study enrolled patients referred for de novo or second ablations of recurrent monomorphic VT of both ischaemic and non-ischaemic aetiologies. Primary safety and efficacy endpoints of the study were freedom from device- or procedure-related major adverse events (MAEs) up to 30 days post-ablation, acute non-inducibility of clinical VTs at the end of the procedure, and freedom from sustained VT or implantable defibrillator intervention at 6 months. Ultra-low-temperature cryoablation was performed in 64 patients (age 67 ± 11 years, 78% ischaemic, ejection fraction = 35 ± 10%) at 9 centres. The primary acute effectiveness endpoint was achieved in 94% (51/54) of patients in whom post-ablation induction was attempted. There were no protocol-defined MAEs; four procedure-related serious adverse events resolved without clinical sequelae. At 6-month follow-up, 38 patients (60.3%) remained VT-free, and freedom from defibrillator shock was 81.0%, with no significant difference between ischaemic and non-ischaemic cohorts. In 47 patients with defibrillator for at least 6 months prior to the ablation, the VT burden was reduced from median of 4, inter-quartile range (IQR, 1-9) to 0, IQR (0-2). CONCLUSION: In this first-in-human multi-centre experience, endocardial ULTC ablation of monomorphic VT appears safe and effective in patients with both ischaemic-cardiomyopathy and non-ischaemic-cardiomyopathy. CLINICAL TRIAL REGISTRATION: NCT04893317.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Criocirugía , Taquicardia Ventricular , Anciano , Humanos , Persona de Mediana Edad , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico , Cardiomiopatías/cirugía , Ablación por Catéter/efectos adversos , Cicatriz/complicaciones , Criocirugía/efectos adversos , Estudios Prospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía , Temperatura , Resultado del Tratamiento
7.
Heart Rhythm ; 21(6): 836-844, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38336193

RESUMEN

BACKGROUND: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events. OBJECTIVE: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias. METHODS: This multicenter investigator-initiated trial randomized 965 patients between DFT and PRAETORIAN score calculation after de novo S-ICD implantation. Successful DFT was defined as conversion of induced ventricular arrhythmia in <5 seconds from shock delivery within 2 attempts. Bidirectional chest radiographs were obtained after implantation. The predictive value of the PRAETORIAN score for DFT success was calculated for patients in the DFT arm. RESULTS: In total, 482 patients were randomized to undergo DFT. Of these patients, 457 (95%) underwent DFT according to protocol, of whom 445 (97%) had successful DFT and 12 (3%) had failed DFT. A PRAETORIAN score of ≥90 had a positive predictive value of 25% for failed DFT, and a PRAETORIAN score of <90 had a negative predictive value of 99% for successful DFT. A PRAETORIAN score of ≥90 was the strongest independent predictor for failed DFT (odds ratio 33.77; confidence interval 6.13-279.95; P < .001). CONCLUSION: A PRAETORIAN score of <90 serves as a reliable indicator for DFT success in patients with S-ICD, and a PRAETORIAN score of ≥90 is a strong predictor for DFT failure.


Asunto(s)
Desfibriladores Implantables , Cardioversión Eléctrica , Valor Predictivo de las Pruebas , Humanos , Femenino , Masculino , Persona de Mediana Edad , Cardioversión Eléctrica/métodos , Estudios Prospectivos , Anciano , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Medición de Riesgo/métodos , Taquicardia Ventricular/terapia , Taquicardia Ventricular/fisiopatología , Fibrilación Ventricular/terapia
9.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38291925

RESUMEN

A significant proportion of patients who suffer from atrial fibrillation (AF) and are in need of thromboembolic protection are not treated with oral anticoagulation or discontinue this treatment shortly after its initiation. This undertreatment has not improved sufficiently despite the availability of direct oral anticoagulants which are associated with less major bleeding than vitamin K antagonists. Multiple reasons account for this, including bleeding events or ischaemic strokes whilst on anticoagulation, a serious risk of bleeding events, poor treatment compliance despite best educational attempts, or aversion to drug therapy. An alternative interventional therapy, which is not associated with long-term bleeding and is as effective as vitamin K anticoagulation, was introduced over 20 years ago. Because of significant improvements in procedural safety over the years, left atrial appendage closure, predominantly achieved using a catheter-based, device implantation approach, is increasingly favoured for the prevention of thromboembolic events in patients who cannot achieve effective anticoagulation. This management strategy is well known to the interventional cardiologist/electrophysiologist but is not more widely appreciated within cardiology or internal medicine. This article introduces the devices and briefly explains the implantation technique. The indications and device follow-up are more comprehensively described. Almost all physicians who care for adult patients will have many with AF. This practical guide, written within guideline/guidance boundaries, is aimed at those non-implanting physicians who may need to refer patients for consideration of this new therapy, which is becoming increasingly popular.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Médicos , Accidente Cerebrovascular , Tromboembolia , Adulto , Humanos , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/complicaciones , Cierre del Apéndice Auricular Izquierdo , Consenso , Hemorragia/inducido químicamente , Hemorragia/prevención & control , Anticoagulantes/efectos adversos , Tromboembolia/etiología , Tromboembolia/prevención & control , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Vitamina K , Apéndice Atrial/cirugía , Resultado del Tratamiento
12.
J Cardiovasc Electrophysiol ; 35(2): 240-246, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38047465

RESUMEN

INTRODUCTION: The pivotal study of the extravascular implantable cardioverter-defibrillator (EV ICD) recently demonstrated primary efficacy and safety endpoints comparable to previous ICD systems. Patient experience with this novel device has not been reported. The current study examined the standardized patient-reported outcome (PRO) metrics of quality of life (QOL) and patient acceptance of the device. METHODS: The EV ICD Pivotal Study was a prospective, single-arm, nonrandomized, global, premarket approval trial. Patients completed the 12-Item Short Form Survey (SF-12) QOL surveys at baseline and at 6 months following implant. Additionally, patients completed the Florida Patient Acceptance Survey (FPAS) QOL survey at 6 months. RESULTS: From baseline to 6 months, patients within the EV ICD Pivotal Study (n = 247) reported statistically significant SF-12 improvements in physical QOL (45.4 ± 9.4 vs. 46.8 ± 9.1 respectively, p = .020) and no changes in mental QOL (49.3 ± 10.4 vs. 50.5 ± 9.7, p = .061). No differences were noted by sex, atrial fibrillation, or the experience of ICD shock. EV ICD patients reported better total FPAS patient acceptance of their ICD than TV-ICD or S-ICD patients using historical norms comparisons (80.4 ± 15.7 vs. 70.2 ± 17.8, p < .0001 for S-ICD and 73.0 ± 17.4, p = .004 for TV-ICD). CONCLUSION: The initial PROs for EV ICD patients indicated that patients had improvements in physical QOL from baseline to 6-month follow-up and markedly better overall acceptance of their ICD compared to a previous study with S-ICD and TV-ICD data. These initial results suggest that the EV ICD is evaluated positively by patients.


Asunto(s)
Desfibriladores Implantables , Humanos , Calidad de Vida , Estudios Prospectivos , Encuestas y Cuestionarios , Medición de Resultados Informados por el Paciente
13.
J Clin Med ; 12(20)2023 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-37892626

RESUMEN

Atrial fibrillation (AF) is the most common arrhythmia in adults worldwide and represents an important burden for patients, physicians, and healthcare systems. AF is associated with substantial mortality and morbidity, due to the disease itself and its specific complications, such as the increased risk of stroke and thromboembolic events associated with AF. The temporal relation between AF episodes and stroke is nonetheless incompletely understood. The factors associated with an increased thromboembolic risk remain unclear, as well as the stroke risk stratification. Therefore, in this review, we intend to expose the mechanisms and physiopathology leading to intracardiac thrombus formation and stroke in AF patients, together with the evidence supporting the causal hypothesis. We also expose the risk factors associated with increased risk of stroke, the current different risk stratification tools as well as future prospects for improving this risk stratification.

14.
J Arrhythm ; 39(5): 776-783, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37799786

RESUMEN

Background: The tissue response viewer (TRV) is a novel marker for ablation lesion quality that aims to classify lesions into transmural or nontransmural lesions (high or low dielectric response, HDR or LDR) using dielectric-based tissue assessment. The objective of this study was to gain insight in the TRV by relating its outcomes to conventional ablation parameters. Methods: Patients that had repeat ablation for atrial fibrillation with a dielectric imaging-based mapping system were enrolled. All ablation data were downloaded from the mapping system and analyzed to explore associations between TRV outcomes and other ablation parameters. Results: The cohort included 24 patients, in which 58 pulmonary veins and 8 superior vena cavas were targeted. A total of 388 energy applications were applied, resulting in 639 ablation points. The system classified 36% of ablation points as HDR and 44% as LDR. The system did not provide a dielectric response in 20%. The system's ability to provide a dielectric response was related to longer ablation duration and absence of dragging ablation. HDR (versus LDR) was multivariably associated with longer energy applications, higher mean ablation power, and lower wall thickness. Greater impedance drop was univariably associated with HDR. Conclusion: Outcomes of the TRV are associated with conventional ablation parameters (e.g., duration and power) but also local wall thickness. Catheter stability seems important for successful lesion assessment with the TRV. Further reduction of missing outcomes and validation of the tool are warranted before widespread use.

15.
Pacing Clin Electrophysiol ; 46(11): 1403-1411, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37724739

RESUMEN

BACKGROUND: High-density (HD) mapping is increasingly used to characterize arrhythmic substrate for ablation of atypical atrial flutters (AAFl). However, results on clinical outcomes and factors that are associated with arrhythmia recurrence are scarce. METHODS: Single-center, prospective, observational cohort study that enrolled patients with catheter ablation for AAFl using a HD mapping system and a grid-shaped mapping catheter. Procedural characteristics, rates of atrial flutter recurrence, and factors that were associated with atrial flutter recurrence were evaluated. RESULTS: Sixty-one patients with a total of 94 AAFl were included in the cohort. HD mapping was used to successfully identify the flutter circuit of 80/94 AAFl. The circuit was not identified for 14/94 AAFl in 11 patients. Critical isthmuses were identified and ablated in 29 patients (48%). Acute procedural success was achieved in 52 patients (85%), and 37 patients (61%) remained free from atrial flutter recurrence during a follow up of 1.3 [1.0-2.1] years. Atrial flutter recurrence was univariably associated with presence of a non-identified flutter circuit (HR:2.6 95% CI [1.1-6.3], p = .04) and critical isthmus-targeted ablation (HR:0.4 [0.15-0.90], p = .03). In multivariable regression analyses, critical isthmus ablation remained significant (HR:0.4 [0.16-0.97], p = .04), whereas presence of a non-identified flutter did not (HR:2.4 [0.96-5.8], p = .06). CONCLUSION: HD mapping was successfully used to identify the majority of AAFl circuits. Ablation resulted in freedom from atrial flutter recurrence in 61% of the cohort. Successful identification of all flutter circuits and critical isthmuses appears to be beneficial for long-term outcomes.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Humanos , Estudios Prospectivos , Estudios de Cohortes , Ablación por Catéter/métodos
16.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37622592

RESUMEN

The first edition of Europace journal in 1999 came right around the time of the landmark publication of the electrophysiologists from Bordeaux, establishing how elimination of ectopic activity from the pulmonary veins (PVs) resulted in a marked reduction of atrial fibrillation (AF). The past 25 years have seen an incredible surge in scientific interest to develop new catheters and energy sources to optimize durability and safety of ablation, as well as study the mechanisms for AF and devise ablation strategies. While ablation in the beginning was performed with classic 4 mm tip catheters that emitted radiofrequency (RF) energy to create tissue lesions, this evolved to using irrigation and contact force (CF) measurement while increasing power. Also, so-called single-shot devices were developed with balloons and arrays to create larger contiguous lesions, and energy sources changed from RF current to cryogenic ablation and more recently pulsed field ablation with electrical current. Although PV ablation has remained the basis for every AF ablation, it was soon recognized that this was not enough to cure all patients, especially those with non-paroxysmal AF. Standardized approaches for additional ablation targets have been used but have not been satisfactory in all patients so far. This led to highly technical mapping systems that are meant to unravel the drivers for the maintenance of AF. In the following sections, the development of energies, strategies, and tools is described with a focus on the contribution of Europace to publish the outcomes of studies that were done during the past 25 years.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Catéteres , Terapia de Electroporación Irreversible
17.
JACC Cardiovasc Interv ; 16(15): 1889-1898, 2023 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-37587597

RESUMEN

BACKGROUND: Left atrial appendage occlusion (LAAO) procedures are widely guided by standard transesophageal echocardiography (TEE) probes, requiring general anesthesia in most patients. The use of miniaturized TEE probes allows for LAAO guidance under local anesthesia and offers an attractive imaging alternative to standard TEE probes. OBJECTIVES: The aim of this study was to assess the safety and efficacy of miniaturized TEE probes for procedural guidance of LAAO. METHODS: Multicenter retrospective observational study of LAAO procedures performed under miniaturized TEE guidance and conscious sedation. The primary efficacy endpoint was technical success. The secondary efficacy endpoint was procedural success (technical success without major periprocedural complications). The safety outcome was a composite of major periprocedural complications. RESULTS: A total of 546 consecutive LAAO procedures were performed in 5 European centers. Technical success was achieved in 534 (98.0%) patients. Sixteen major periprocedural complications occurred in 15 (2.9%) patients, yielding a procedural success rate of 97.0%. Conversion to general anesthesia was required in 4 (0.7%) patients. Short-term imaging follow-up was available in 422 patients with an incidence of major (>5 mm) TEE-detected residual leaks of 0.7%, complete LAA occlusion of 82.2% on cardiac computed tomography, and device-related thrombus of 5%. As compared with procedural 2-dimensional imaging for device sizing, preprocedural assessment by 3-dimensional imaging resulted in improved technical success (100% vs 95.0%; P < 0.001). CONCLUSIONS: LAAO under conscious sedation and miniaturized TEE guidance is safe and feasible with a high rate of technical success and a low rate of periprocedural complications.


Asunto(s)
Apéndice Atrial , Ecocardiografía Transesofágica , Humanos , Sedación Consciente/efectos adversos , Apéndice Atrial/diagnóstico por imagen , Resultado del Tratamiento , Anestesia General
18.
Heart Rhythm ; 20(12): 1649-1656, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37579867

RESUMEN

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) delivers 80 J shocks from an 8 cm left-parasternal coil to a 59 cm3 left lateral pulse generator (PG). A system that defibrillates with lower energy could significantly reduce PG size. Computer modeling and animal studies suggested that a second shock coil either parallel to the left-parasternal coil or transverse from the xiphoid to the PG pocket would significantly reduce the defibrillation threshold. OBJECTIVE: The purpose of this study was to acutely assess the defibrillation efficacy of parallel and transverse configurations in patients receiving an S-ICD. METHODS: Testing was performed in patients receiving a conventional S-ICD system. Success at 65 J was required before investigational testing. A second electrode was temporarily inserted from the xiphoid incision connected to the PG with an investigational Y-adapter. Phase 1 (n = 11) tested the parallel configuration. Phase 2 (n = 21) tested both parallel and transverse configurations in random order. RESULTS: This study enrolled 35 patients (28 males (80%); mean age 51 ± 17 years; left ventricular ejection fraction 40% ± 15%; body mass index 26 ± 4 kg/m2; prior myocardial infarction 46%; congestive heart failure 49%; cardiomyopathy 63%). Compared to the conventional S-ICD system, mean shock impedance decreased for both parallel (69 ± 15 Ω vs 86 ± 20 Ω; n = 33; P < .001) and transverse (56 ± 14 Ω vs 81 ± 21 Ω; n = 20; P < .001) configurations. Shock success rates at 20, 30, and 40 J were 55%, 79%, 97%, and 25%, 70%, 90% for parallel and transverse configurations, respectively. Defibrillation threshold testing was well tolerated with no serious adverse events. CONCLUSION: Adding a second shock coil, particularly in the parallel configuration, significantly reduced the impedance and had a high likelihood of defibrillation success at energies ≤40 J. This may enable the development of a smaller S-ICD.


Asunto(s)
Cardiomiopatías , Desfibriladores Implantables , Adulto , Anciano , Humanos , Masculino , Persona de Mediana Edad , Índice de Masa Corporal , Cardiomiopatías/etiología , Desfibriladores Implantables/efectos adversos , Cardioversión Eléctrica/efectos adversos , Volumen Sistólico , Fibrilación Ventricular/etiología , Función Ventricular Izquierda
20.
Heart Rhythm O2 ; 4(7): 448-456, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37520021

RESUMEN

Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD) has demonstrated safety and efficacy for the treatment of malignant ventricular arrhythmias. However, a limitation of the S-ICD lies in the inability to either pace-terminate ventricular tachycardia or provide prolonged bradycardia pacing support. Objective: The rationale and design of a prospective, single-arm, multinational trial of an intercommunicative leadless pacing system integrated with the S-ICD will be presented. Methods: A technical description of the modular cardiac rhythm management (mCRM) system (EMPOWER leadless pacemaker and EMBLEM S-ICD) and the implantation procedure is provided. MODULAR ATP (Effectiveness of the EMPOWER™ Modular Pacing System and EMBLEM™ Subcutaneous ICD to Communicate Antitachycardia Pacing) is a multicenter, international trial enrolling up to 300 patients at risk of sudden cardiac death at up to 60 centers trial design. The safety endpoint of freedom from major complications related to the mCRM system or implantation procedure at 6 months and 2 years are significantly higher than 86% and 81%, respectively, and all-cause survival is significantly >85% at 2 years. Results: Efficacy endpoints are that at 6 months mCRM communication success is significantly higher than 88% and the percentage of subjects with low and stable thresholds is significantly higher than 80%. Substudies to evaluate rate-responsive features and performance of the pacing module are also described. Conclusion: The MODULAR ATP global clinical trial will prospectively test the safety and efficacy of the first intercommunicating leadless pacing system with the S-ICD. This trial will allow for robust validation of device-device communication, pacing performance, rate responsiveness, and system safety.