Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Bone Joint J ; 100-B(12): 1579-1584, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30499327

RESUMEN

AIMS: The introduction of a novel design of total knee arthroplasty (TKA) must achieve outcomes at least as good as existing designs. A novel design of TKA with a reducing radius of the femoral component and a modified cam-post articulation has been released and requires assessment of the fixation to bone. Radiostereometric analysis (RSA) of the components within the first two postoperative years has been shown to be predictive of medium- to long-term fixation. The aim of this study was to assess the stability of the tibial component of this system during this period of time using RSA. PATIENTS AND METHODS: A cohort of 30 patients underwent primary, cemented TKA using the novel posterior stabilized fixed-bearing (ATTUNE) design. There was an even distribution of men and women (15:15). The mean age of the patients was 64 years (sd 8) at the time of surgery; their mean body mass index (BMI) was 35.4 kg/m 2 (sd 7.9). RSA was used to assess the stability of the tibial component at 6, 12, and 24 months compared with a six-week baseline examination. Patient-reported outcome measures were also assessed. RESULTS: The mean maximum total point motion (MTPM) of the tibial component between 12 and 24 months postoperatively was 0.08 mm (sd 0.08), which is well below the published threshold of 0.2 mm (p < 0.001). Patient-reported outcome measures consistently improved. CONCLUSION: The tibial component of this novel design of TKA showed stability between assessment 12 and 24 months postoperatively, suggesting an acceptably low risk of medium- to long-term failure due to aseptic loosening.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Cementos para Huesos , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Análisis Radioestereométrico/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Periodo Posoperatorio , Diseño de Prótesis , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
2.
Bone Joint J ; 100-B(9): 1168-1174, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30168766

RESUMEN

Aims: The aim of this study was to assess the effect of multimorbidity on improvements in health-related quality of life (HRQoL) following total hip arthroplasty (THA) and total knee arthroplasty (TKA). Patients and Methods: Using data from a regional joint registry for 14 573 patients, HRQoL was measured prior and one year following surgery using the Oxford Hip Score (OHS) and Oxford Knee Score (OKS), and the 12-Item Short-Form Health Survey Physical and Mental Component Summary scores (PCS and MCS, respectively). Multimorbidity was defined as the concurrence of two or more self-reported chronic conditions. A linear mixed-effects model was used to test the effects of multimorbidity and the number of chronic conditions on improvements in HRQoL. Results: Almost two-thirds of patients had multimorbidity, which adversely effected improvements in HRQoL. For THA, mean improvements in HRQoL scores were reduced by 2.21 points in OHS, 1.62 in PCS, and 4.14 in MCS; for TKA, the mean improvements were reduced by 1.71 points in OKS, 1.92 in PCS, and 3.55 in MCS (all p < 0.0001). An increase in the number of chronic conditions was associated with increasing reductions in HRQoL improvements. Conclusion: Multimorbidity adversely effects improvements in HRQoL following THA and TKA. Our findings are relevant to healthcare providers focused on the management of patients with chronic conditions and for administrators reporting and monitoring the outcomes of THA and TKA. Cite this article: Bone Joint J 2018;100-B:1168-74.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Osteoartritis de la Cadera/cirugía , Osteoartritis de la Rodilla/cirugía , Calidad de Vida , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Rodilla/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Multimorbilidad , Sistema de Registros , Índice de Severidad de la Enfermedad , Encuestas y Cuestionarios , Adulto Joven
3.
J Mech Behav Biomed Mater ; 34: 208-16, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24607759

RESUMEN

The wear performance of two types of crosslinked polyethylene (Marathon™ and XLK™, DePuy Synthes Inc., Warsaw, IN) was evaluated in a pin-on-disc wear tester, a hip wear simulator, and a knee wear simulator. Sodium azide was used as the microbial inhibitor in the calf serum-based lubricant. In the pin-on-disc wear tester, the Marathon wear rate of 5.33±0.54mm(3)/Mc was significantly lower (p=0.002) than the wear rate of 6.43±0.60mm(3)/Mc for XLK. Inversely, the Marathon wear rate of 15.07±1.03mm(3)/Mc from the hip wear simulator was 2.2-times greater than the XLK wear rate of 6.71±1.03mm(3)/Mc from the knee wear simulator. Differences in implant design, conformity, GUR type, and kinematic test conditions were suggested to account for the difference between the wear rates generated in the different types of wear testing apparati. In all wear tests, sodium azide was ineffective at inhibiting microbial growth in the lubricant. Eight different organisms were identified in the lubricant samples from the wear tests, which suggested the necessity of using an alternative, more effective microbial inhibitor. Careful sample preparation and thorough cleaning has shown to improve the consistency of the wear results. The wear rates generated in the hip and knee wear simulators closely reflected the wear behaviour of Marathon and XLK reported in published data that were tested under similar conditions.


Asunto(s)
Artroplastia de Reemplazo , Ensayo de Materiales , Microbiología , Polietileno/química , Falla de Prótesis , Antiinfecciosos/farmacología , Azidas/farmacología
4.
Knee ; 20(6): 388-96, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23583666

RESUMEN

BACKGROUND: The surface characteristics of the femoral component affect polyethylene wear in modular total knee replacements. In the present retrieval study, the surface characteristics of cobalt-chromium (CoCr) alloy and oxidized zirconium (OxZr) femoral components were assessed and compared. METHODS: Twenty-six retrieved CoCr alloy femoral components were matched with twenty-six retrieved OxZr femoral components for implantation period, body-mass index, patient gender, implant type, and polyethylene insert thickness. The surface damage on the retrieved femoral components was evaluated using a semi-quantitative assessment method, scanning electron microscopy, and contact profilometry. RESULTS: The retrieved CoCr alloy femoral components showed less posterior surface gouging than OxZr femoral components; however, at a higher magnification, the grooving damage features on the retrieved CoCr alloy femoral components confirmed an abrasive wear mechanism. The surface roughness values Rp, Rpm, and Rpk for the retrieved CoCr alloy femoral components were found to be significantly higher than those of the retrieved OxZr femoral components (p≤0.031). The surface roughness values were higher on the medial condyles than on the lateral condyles of the retrieved CoCr alloy femoral components; such a difference was not observed on the retrieved OxZr femoral components. CONCLUSIONS: The surface roughness of CoCr alloy femoral components increased while the surface roughness of the OxZr femoral components remained unchanged after in vivo service. Therefore, the OxZr femoral components' resistance to abrasive wear may enable lower polyethylene wear and ensure long-term durability in vivo. LEVEL OF EVIDENCE: Level IV.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Aleaciones de Cromo , Prótesis de la Rodilla , Diseño de Prótesis , Anciano , Artroplastia de Reemplazo de Rodilla/efectos adversos , Fuerza Compresiva , Bases de Datos Factuales , Femenino , Fémur , Estudios de Seguimiento , Humanos , Masculino , Ensayo de Materiales/métodos , Persona de Mediana Edad , Falla de Prótesis , Recuperación de la Función , Estudios Retrospectivos , Medición de Riesgo , Resultado del Tratamiento , Circonio
5.
J Bone Joint Surg Br ; 94(9): 1160-9, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22933485

RESUMEN

This review considers the surgical treatment of displaced fractures involving the knee in elderly, osteoporotic patients. The goals of treatment include pain control, early mobilisation, avoidance of complications and minimising the need for further surgery. Open reduction and internal fixation (ORIF) frequently results in loss of reduction, which can result in post-traumatic arthritis and the occasional conversion to total knee replacement (TKR). TKR after failed internal fixation is challenging, with modest functional outcomes and high complication rates. TKR undertaken as treatment of the initial fracture has better results to late TKR, but does not match the outcome of primary TKR without complications. Given the relatively infrequent need for late TKR following failed fixation, ORIF is the preferred management for most cases. Early TKR can be considered for those patients with pre-existing arthritis, bicondylar femoral fractures, those who would be unable to comply with weight-bearing restrictions, or where a single definitive procedure is required.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/estadística & datos numéricos , Fijación Interna de Fracturas/estadística & datos numéricos , Traumatismos de la Rodilla/cirugía , Articulación de la Rodilla/cirugía , Fracturas Osteoporóticas/cirugía , Anciano , Fracturas del Fémur/clasificación , Fracturas del Fémur/complicaciones , Fracturas del Fémur/cirugía , Fijación Interna de Fracturas/métodos , Humanos , Traumatismos de la Rodilla/clasificación , Traumatismos de la Rodilla/complicaciones , Persona de Mediana Edad , Osteoartritis/etiología , Fracturas Osteoporóticas/clasificación , Fracturas Osteoporóticas/complicaciones , Cuidados Posoperatorios , Rango del Movimiento Articular , Fracturas de la Tibia/clasificación , Fracturas de la Tibia/complicaciones , Fracturas de la Tibia/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...