Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
2.
ASAIO J ; 69(10): 950-955, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37367716

RESUMEN

The literature regarding Clostridioides difficile infection (CDI) in left ventricular assist devices (LVADs) patients is limited. Therefore, we aimed to characterize the clinical course, risk factors, management, and outcomes of LVAD patients who developed CDI. Adult patients who underwent LVAD placement during 2010-2022 and developed CDI were included. To determine risk factors and outcomes, we matched CDI patients with LVAD patients who did not develop CDI. Each CDI case was matched with up to two control subjects by age, sex, and time from LVAD implantation. Forty-seven of 393 LVAD patients (12.0%) developed CDI. The median time from LVAD implantation to CDI was 147 days (interquartile range 22.5-647.0). The most common CDI treatment was oral vancomycin (n = 26, 55.3%). Thirteen patients (27.7%) required treatment extension because of a lack of clinical response. Three patients (6.4%) developed recurrent CDI. When 42 cases were matched to 79 control subjects, antibiotic exposure within 90 days was significantly associated with CDI (adjusted odds ratio 5.77; 95% confidence interval, 1.87-17.74; p = 0.002). Moreover, CDI was associated with 1 year mortality (adjusted hazard ratio 2.62; 95% confidence interval, 1.18-5.82; p = 0.018). This infection occurs most often within the first year after LVAD implantation and was associated with 1 year mortality. Antibiotic exposure is an important risk for CDI.


Asunto(s)
Infecciones por Clostridium , Corazón Auxiliar , Adulto , Humanos , Corazón Auxiliar/efectos adversos , Estudios Retrospectivos , Antibacterianos/uso terapéutico , Infecciones por Clostridium/etiología , Infecciones por Clostridium/inducido químicamente , Factores de Riesgo
3.
Mayo Clin Proc ; 98(3): 372-385, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36868745

RESUMEN

OBJECTIVE: To ascertain whether heart failure (HF) itself is a senescent phenomenon independent of age, and how this is reflected at a molecular level in the circulating progenitor cell niche, and at a substrate level using a novel electrocardiogram (ECG)-based artificial intelligence platform. PATIENTS AND METHODS: Between October 14, 2016, and October 29, 2020, CD34+ progenitor cells were analyzed by flow cytometry and isolated by magnetic-activated cell sorting from patients of similar age with New York Heart Association functional classes IV (n = 17) and I-II (n = 10) heart failure with reduced ejection fraction and healthy controls (n = 10). CD34+ cellular senescence was quantitated by human telomerase reverse transcriptase expression and telomerase expression by quantitative polymerase chain reaction, and senescence-associated secretory phenotype (SASP) protein expression assayed in plasma. An ECG-based artificial intelligence (AI) algorithm was used to determine cardiac age and difference from chronological age (AI ECG age gap). RESULTS: CD34+ counts and telomerase expression were significantly reduced and AI ECG age gap and SASP expression increased in all HF groups compared with healthy controls. Expression of SASP protein was closely associated with telomerase activity and severity of HF phenotype and inflammation. Telomerase activity was more closely associated with CD34+ cell counts and AI ECG age gap. CONCLUSION: We conclude from this pilot study that HF may promote a senescent phenotype independent of chronological age. We show for the first time that the AI ECG in HF shows a phenotype of cardiac aging beyond chronological age, and appears to be associated with cellular and molecular evidence of senescence.


Asunto(s)
Insuficiencia Cardíaca , Telomerasa , Humanos , Inteligencia Artificial , Proyectos Piloto , Electrocardiografía , Biomarcadores
5.
Heliyon ; 7(8): e07779, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34458617

RESUMEN

The localization and quantification of endothelial progenitor cells (EPCs) are controversial. Circulating CD34 + cells in blood have been identified as EPCs and as biomarkers of cardiovascular disease. We discuss in this paper the current data describing differential phenotype and behavior in vitro of CD34 positive cells from the circulation and adipose tissue (AT). We also describe in brief our own findings from CD34 + cells isolated from leukopheresis cones derived from healthy platelet donors and from patients undergoing bariatric surgery. We conclude that CD34 + cells in blood and in AT are different in antigenic profile and behavior in culture. The findings described assert that CD34 + cells detected in blood previously identified as biomarkers of cardiovascular disease are predominantly HPCs rather than EPCs, and that true CD34 + EPCs can be readily identified and extracted from AT, supportive of the current evidence which suggests EPCs are resident in the tissue vasculature.

6.
Mayo Clin Proc ; 96(4): 887-900, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33814091

RESUMEN

OBJECTIVE: To characterize the properties of the audible tones produced by current left ventricular assist device (LVAD) pumps approved for use, and to ascertain if changes in those may be present in the setting of pump thrombosis. PATIENTS AND METHODS: From August 31, 2016, to January 16, 2020, LVAD recipients consented to have surface recordings obtained using a high-fidelity digital stethoscope. Audio data were analyzed using digital recording and editing software to produce an acoustic spectrogram by Fast Fourier transformation. RESULTS: Recordings were obtained in 53 patient encounters (27 HeartMate II, 19 HeartWare and 7 HeartMate 3). In 12 patients (9 HeartMate II, 3 HeartWare) there was a clinical concern for pump thrombosis. In all patients and pump models, a fundamental frequency was noted, and the second and third harmonics were also clearly detectable. Where thrombosis occurred in the HeartMate II pump, the absolute (normal -46.9 [-57.5,-42.9] dB vs thrombosis -41.4 [-49.8,-26.8] dB; P=.08) and relative (normal 0.72 [0.62, 0.92] vs thrombosis 0.95 [0.86, 1.24]; P=.01) third harmonic frequencies were increased in amplitude. Where paired data were available, an increase in the absolute and relative third harmonic frequencies was observed in all patients. In the case of the HeartWare device, a consistent difference in harmonic amplitudes in the setting of thrombosis could not be identified. CONCLUSION: A consistent pattern of fundamental and harmonic frequencies is common to all LVADs currently approved for use. Alterations in the amplitude of higher order harmonics may signal the onset of pump thrombosis in axial flow LVADs.


Asunto(s)
Acústica , Circulación Sanguínea/fisiología , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Trombosis/prevención & control , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
7.
Case Rep Cardiol ; 2021: 6641108, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33763259

RESUMEN

We present an adolescent African American male admitted to the cardiac intensive care unit with cardiogenic shock and acute respiratory failure. Through an overview of his presentation, diagnostic workup, and treatment, we demonstrate the clinical utility of genetic testing in the evaluation of unexplained dilated cardiomyopathies.

8.
J Am Coll Cardiol ; 77(10): 1331-1340, 2021 03 16.
Artículo en Inglés | MEDLINE | ID: mdl-33706876

RESUMEN

BACKGROUND: In patients undergoing heart transplantation, significant allosensitization limits access to organs, resulting in longer wait times and high waitlist mortality. Current desensitization strategies are limited in enabling successful transplantation. OBJECTIVES: The purpose of this study was to describe the cumulative experience of combined heart-liver transplantation using a novel heart-after-liver transplant (HALT) protocol resulting in profound immunologic protection. METHODS: Reported are the results of a clinical protocol that was instituted to transplant highly sensitized patients requiring combined heart and liver transplantation at a single institution. Patients were dual-organ listed with perceived elevated risk of rejection or markedly prolonged waitlist time due to high levels of allo-antibodies. Detailed immunological data and long-term patient and graft outcomes were obtained. RESULTS: A total of 7 patients (age 43 ± 7 years, 86% women) with high allosensitization (median calculated panel reactive antibody = 77%) underwent HALT. All had significant, unacceptable donor specific antibodies (DSA) (>4,000 mean fluorescence antibody). Prospective pre-operative flow cytometric T-cell crossmatch was positive in all, and B-cell crossmatch was positive in 5 of 7. After HALT, retrospective crossmatch (B- and T-cell) became negative in all. DSA fell dramatically; at last follow-up, all pre-formed or de novo DSA levels were insignificant at <2,000 mean fluorescence antibody. No patients experienced >1R rejection over a median follow-up of 48 months (interquartile range: 25 to 68 months). There was 1 death due to metastatic cancer and no significant graft dysfunction. CONCLUSIONS: A heart-after-liver transplantation protocol enables successful transplantation via near-elimination of DSA and is effective in preventing adverse immunological outcomes in highly sensitized patients listed for combined heart-liver transplantation.


Asunto(s)
Rechazo de Injerto/prevención & control , Trasplante de Corazón , Trasplante de Hígado , Inmunología del Trasplante , Adulto , Protocolos Clínicos , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad
10.
Heart Lung ; 49(5): 481-487, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32334843

RESUMEN

Ventricular tachycardia (VT) is common in LVAD recipients, and although often well tolerated, may result in symptoms and ICD therapies, and therefore require further evaluation and treatment. However, preload deficiency may also contribute to the development of ventricular tachycardia after LVAD implantation by provoking inflow cannula related VT. In this report, three cases are described where ventricular tachycardia was evaluated by integrated assessment utilizing echo and the HeartWare HVAD console, and successfully treated by modification of LV loading conditions.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Taquicardia Ventricular , Arritmias Cardíacas , Corazón Auxiliar/efectos adversos , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología
11.
Curr Treat Options Cardiovasc Med ; 21(11): 75, 2019 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-31773322

RESUMEN

PURPOSE OF REVIEW: Left ventricular assist device (LVAD) implantation is a well-known treatment option for patients with advanced heart failure refractory to medical therapy and is recognized both as bridge to transplant and a destination therapy. The risk of ventricular arrhythmias (VAs) is common after LVAD implantation. We review the pathophysiology and recent advances in the management of VA in LVAD patients. RECENT FINDINGS: VAs are most likely to occur in the early post-operative periods after LVAD implantation and a prior history of VA is the most important risk factor. Post-LVAD VAs are usually well tolerated with less morbidity and decreased risk of sudden cardiac death. However, risk of right heart failure in the setting of persistent VAs is being increasingly recognized. The mechanisms of post-LVAD VAs may vary depending on the time from LVAD implantation. Electrical remodeling may play an important role in the immediate post-implant phase. Preexisting myocardial scar and to a lesser extent mechanical irritation from the LVAD cannula are important in the later phases. Most LVAD patients have a previously placed implantable cardioverter-defibrillator (ICD). The benefit of implanting a new ICD in LVAD patients is unknown and should be individualized. For ICD programming, a conservative strategy with higher detection zones and prolonged time to detection is usually recommended aiming to minimize ICD shocks. More aggressive programming is appropriate if the VA results in hemodynamic instability. Antiarrhythmic drugs including amiodarone, mexiletine, and beta blockers are usually the first-line therapy for VAs. Catheter ablation has been shown to be safe and effective in LVAD recipients with recurrent VAs not responsive to antiarrhythmic drugs. LVAD-related VA is most frequently reentrant secondary to myocardial scar and usually well tolerated. Management options include antiarrhythmic drugs and catheter ablation.

12.
ASAIO J ; 65(5): 443-448, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-29768282

RESUMEN

Left ventricular assist device (LVAD) pump thrombosis occurs in up to 8.4% of patients within 3-months postimplantation. Thromboelastography (TEG) could be used to signal hypercoagulability at LVAD implantation to predict patients at high risk for thrombosis. We sought to evaluate whether TEG maximum amplitude (MA) hypercoagulability (MA ≥69 mm) at the time of LVAD implantation predicts pump thrombosis. A single center, retrospective, nested case-control study was conducted using patients from January 1, 2005, to March 31, 2015. Each pump thrombosis case was matched to two control subjects based on age ± 5 years, sex, and duration of follow-up. A multivariable logistic regression analysis was performed on the matched sets; the odds ratio with 95% confidence interval (CI) was calculated to estimate the relative risk. Thirty-seven age- and sex-matched case-control sets were included for a total of 111 study participants. TEG-MA hypercoagulability occurred in 10.8% of the case group versus 6.8% of controls. There was no association between TEG-MA hypercoagulability and device thrombosis (odds ratio 1.71, 95% confidence interval 0.42-7.05, p = 0.46). Utilization of baseline TEG-MA hypercoagulability to detect individuals at risk for LVAD thrombosis is a novel concept. This study found no significant association between TEG-MA and LVAD thrombosis.


Asunto(s)
Corazón Auxiliar/efectos adversos , Tromboelastografía/métodos , Trombofilia , Trombosis , Adulto , Anciano , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Riesgo , Trombofilia/etiología , Trombosis/etiología
14.
ESC Heart Fail ; 5(6): 1118-1129, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30019530

RESUMEN

AIMS: Early studies from the 1990s have shown that statins improve survival and attenuate cardiac allograft vasculopathy (CAV). However, little contemporary data are available on the incremental benefit of statins with the current use of new-generation immunosuppressive agents and the use of coronary intravascular ultrasound for assessment of CAV. We sought to investigate the effect of early statin (ES) as compared with late statin (LS) initiation after heart transplantation (HT) on long-term CAV progression and clinical outcomes in a large contemporary HT cohort. METHODS AND RESULTS: We analysed a cohort of 409 adult HT recipients. CAV progression was assessed by serial coronary intravascular ultrasound volumetric measurements of the differences between baseline and last follow-up plaque volume (PV) and plaque index (PV/vessel volume ratio). CAV progression and clinical outcomes were compared between the ES (<2 years after HT) and the LS (>2 years after HT) groups. During a median follow-up of 8.2 years, ES resulted in significantly lower change (Δ) of plaque index (+3.8% ± 1.7% vs. +8.2% ± 3.6%; P = 0.0008) and PV (+0.8 ± 0.3 vs. +1.9 ± 1.2; P = 0.045) compared with LS group. In a Cox proportional hazards regression model and after adjustment for baseline characteristics, ES was associated with a 52% decreased risk of CAV-associated events (hazard ratio 0.48, 95% confidence interval: 0.27-0.91; P = 0.025) and a 42% decreased risk of the composite endpoint of all-cause mortality and CAV-associated events (hazard ratio 0.58, 95% confidence interval: 0.38-0.91; P = 0.019). CONCLUSIONS: Early initiation of statin therapy after HT results in attenuated CAV progression as well as in decreased CAV-related events and mortality.


Asunto(s)
Acilcoenzima A/antagonistas & inhibidores , Vasos Coronarios/diagnóstico por imagen , Rechazo de Injerto/tratamiento farmacológico , Trasplante de Corazón/efectos adversos , Inmunosupresores/administración & dosificación , Enfermedades Vasculares/tratamiento farmacológico , Aloinjertos , Biopsia , Progresión de la Enfermedad , Esquema de Medicación , Femenino , Estudios de Seguimiento , Rechazo de Injerto/diagnóstico , Rechazo de Injerto/etiología , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Factores de Tiempo , Tiempo de Tratamiento , Ultrasonografía Intervencional , Enfermedades Vasculares/diagnóstico , Enfermedades Vasculares/etiología
15.
J Am Coll Cardiol ; 71(6): 636-650, 2018 02 13.
Artículo en Inglés | MEDLINE | ID: mdl-29420960

RESUMEN

BACKGROUND: Small studies have reported superiority of sirolimus (SRL) over calcineurin inhibitor (CNI) in mitigating cardiac allograft vasculopathy (CAV) after heart transplantation (HT). However, data on the long-term effect on CAV progression and clinical outcomes are lacking. OBJECTIVES: The aim of this study was to test the long-term safety and efficacy of conversion from CNI to SRL as maintenance therapy on CAV progression and outcomes after HT. METHODS: A cohort of 402 patients who underwent HT and were either treated with CNI alone (n = 134) or converted from CNI to SRL (n = 268) as primary immunosuppression was analyzed. CAV progression was assessed using serial coronary intravascular ultrasound during treatment with CNI (n = 99) and after conversion to SRL (n = 235) in patients who underwent at least 2 intravascular ultrasound studies. RESULTS: The progression in plaque volume (2.8 ± 2.3 mm3/mm vs. 0.46 ± 1.8 mm3/mm; p < 0.0001) and plaque index (plaque volume-to-vessel volume ratio) (12.2 ± 9.6% vs. 1.1 ± 7.9%; p < 0.0001) were significantly attenuated when treated with SRL compared with CNI. Over a mean follow-up period of 8.9 years from time of HT, all-cause mortality occurred in 25.6% of the patients and was lower during treatment with SRL compared with CNI (adjusted hazard ratio: 0.47; 95% confidence interval: 0.31 to 0.70; p = 0.0002), and CAV-related events were also less frequent during treatment with SRL (adjusted hazard ratio: 0.35; 95% confidence interval: 0.21 to 0.59; p < 0.0001). Further analyses suggested more attenuation of CAV and more favorable clinical outcomes with earlier conversion to SRL (≤2 years) compared with late conversion (>2 years) after HT. CONCLUSIONS: Early conversion to SRL is associated with attenuated CAV progression and with lower long-term mortality and fewer CAV-related events compared with continued CNI use.


Asunto(s)
Rechazo de Injerto/prevención & control , Trasplante de Corazón/tendencias , Inmunosupresores/administración & dosificación , Sirolimus/administración & dosificación , Receptores de Trasplantes , Adulto , Anciano , Inhibidores de la Calcineurina/administración & dosificación , Estudios de Cohortes , Esquema de Medicación , Femenino , Estudios de Seguimiento , Rechazo de Injerto/inmunología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo
16.
Mayo Clin Proc ; 92(5): 719-725, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28473036

RESUMEN

OBJECTIVES: To describe the characteristics of patients who undergo withdrawal of total artificial heart support and to explore the ethical aspects of withdrawing this life-sustaining treatment. PATIENTS AND METHODS: We retrospectively reviewed the medical records of all adult recipients of a total artificial heart at Mayo Clinic from the program's inception in 2007 through June 30, 2015. Management of other life-sustaining therapies, approach to end-of-life decision making, engagement of ethics and palliative care consultation, and causes of death were analyzed. RESULTS: Of 47 total artificial heart recipients, 14 patients or their surrogates (30%) requested withdrawal of total artificial heart support. No request was denied by treatment teams. All 14 patients were supported with at least 1 other life-sustaining therapy. Only 1 patient was able to participate in decision making. CONCLUSION: It is widely held to be ethically permissible to withdraw a life-sustaining treatment when the treatment no longer meets the patient's health care-related goals (ie, the burdens outweigh the benefits). These data suggest that some patients, surrogates, physicians, and other care providers believe that this principle extends to the withdrawal of total artificial heart support.


Asunto(s)
Corazón Artificial/ética , Cuidados para Prolongación de la Vida/ética , Insuficiencia Multiorgánica/mortalidad , Privación de Tratamiento/ética , Adulto , Directivas Anticipadas/ética , Directivas Anticipadas/estadística & datos numéricos , Anciano , Causas de Muerte , Toma de Decisiones/ética , Análisis Ético , Femenino , Corazón Artificial/efectos adversos , Corazón Artificial/estadística & datos numéricos , Humanos , Masculino , Inutilidad Médica/ética , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud/estadística & datos numéricos , Apoderado , Estudios Retrospectivos , Análisis de Supervivencia
17.
ASAIO J ; 61(6): 670-5, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26181710

RESUMEN

The number of patients with left ventricular assist devices (LVADs) continues to increase, and gastrointestinal (GI) endoscopy is commonly required in this patient population. We retrospectively reviewed the experience of a single tertiary care center in managing patients with LVADs undergoing GI endoscopy between 2006 and 2013. After hospital dismissal from the LVAD placement, 53 patients underwent 172 GI endoscopic procedures. Gastrointestinal bleeding was the indication for endoscopy in 73.8% of patients. Median age at endoscopy was 66 years, and median time from LVAD implantation to initial endoscopy was 271 days (range, 31-1681 days). Anticoagulation or antiplatelet therapy was present within 1 week before 120 of 172 endoscopies (70%) and was withheld or actively reversed in 91 of 120 cases (76%). For sedation/anesthesia during endoscopy, 63 involved care by an anesthesiology team and 109 were performed with nursing sedation protocols. Noninvasive blood pressure techniques (conventional automated cuffs or Doppler pulses) were used for hemodynamic monitoring in 84%, arterial lines in 10%, and no blood pressure recordings documented/charted as inaccurate in 6%. Six patients died within 30 days of endoscopy with one death because of aspiration of blood and multiorgan failure. Patients with LVADs may safely undergo GI endoscopy with various individualized anesthetic/sedation models. Complications after endoscopy likely represent the acuity of this patient population.


Asunto(s)
Endoscopía Gastrointestinal , Hemorragia Gastrointestinal/etiología , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Anciano , Anciano de 80 o más Años , Anticoagulantes/efectos adversos , Sedación Consciente , Endoscopía Gastrointestinal/efectos adversos , Endoscopía Gastrointestinal/métodos , Endoscopía Gastrointestinal/mortalidad , Femenino , Insuficiencia Cardíaca/complicaciones , Humanos , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/efectos adversos , Cuidados Preoperatorios
18.
Acute Card Care ; 17(3): 41-4, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26982531

RESUMEN

Acute mitral regurgitation (AMR), a known complication of acute coronary syndromes, is usually associated with posterior papillary muscle dysfunction/rupture. In severe cases, management of AMR requires surgical intervention. Reversible severe AMR in patients in the absence of left ventricular systolic dysfunction and coronary artery stenosis may result from processes which cause transient subendocardial ischemia, such as intermittent episodes of hypotension or coronary artery vasospasm. We present two cases of reversible transient AMR due to subendocardial and/or endocardial ischemia, both of which offer insight into the mechanism of transient severe AMR.


Asunto(s)
Vasoespasmo Coronario/complicaciones , Insuficiencia de la Válvula Mitral/etiología , Enfermedad Aguda , Anciano , Cateterismo Cardíaco , Angiografía Coronaria , Vasoespasmo Coronario/diagnóstico , Ecocardiografía Doppler , Femenino , Humanos , Masculino , Insuficiencia de la Válvula Mitral/diagnóstico , Índice de Severidad de la Enfermedad
19.
Am J Cardiol ; 114(8): 1257-63, 2014 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-25194171

RESUMEN

Left ventricular assist devices (LVADs) acutely decrease left ventricular wall stress. Thus, early postoperative levels of N-terminal pro-brain natriuretic peptide (NT-proBNP) should decrease. This study investigated postoperative changes in NT-proBNP levels, the parameters related to changes, and the possible association with complications by performing a retrospective analysis of changes in daily NT-proBNP (pg/ml) levels from admission to discharge both before and after LVAD implantation in a tertiary referral center. For 72 patients implanted with HeartMate II LVADs, baseline NT-proBNP levels were elevated at 3,943 ng/ml (interquartile range 1,956 to 12,964). Preoperative stabilization led to marked decreases in NT-proBNP. Levels peaked 3 days after surgery and subsequently decreased. Patients with complicated postoperative courses had higher early postoperative elevations. By discharge, NT-proBNP decreased markedly but was still 2.83 (1.60 to 5.76) times the age-based upper limit of normal. The 26% reduction in NT-proBNP between admission and discharge was due mostly to the preoperative reductions and not those induced by the LVAD itself. The decrease was not associated with decreases in LV volume. In conclusion, preoperative treatment reduces NT-proBNP values. The magnitude of early postoperative changes is related to the clinical course. Levels at discharge remain markedly elevated and similar to values after preoperative stabilization despite presumptive acute LV unloading.


Asunto(s)
Insuficiencia Cardíaca/sangre , Ventrículos Cardíacos/fisiopatología , Corazón Auxiliar , Péptido Natriurético Encefálico/sangre , Fragmentos de Péptidos/sangre , Implantación de Prótesis/métodos , Anciano , Biomarcadores/sangre , Ecocardiografía Doppler , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Diseño de Prótesis , Estudios Retrospectivos , Factores de Tiempo , Función Ventricular Izquierda/fisiología
20.
ASAIO J ; 60(5): 513-8, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25068779

RESUMEN

Cardiac output (CO) assessment is important in treating patients with heart failure. Durable left ventricular assist devices (LVADs) provide essentially all CO. In currently used LVADs, estimated device flow is generated by a computerized algorithm. However, LVAD flow estimate may be inaccurate in tracking true CO. We correlated LVAD (HeartMate II) flow with thermodilution CO during postoperative care (day 2-10 after implant) in 81 patients (5,616 paired measurements). Left ventricular assist device flow and CO correlated with a low correlation coefficient (r = 0.42). Left ventricular assist device readings were lower than CO measurements by approximately 0.36 L/min, trending for larger difference with higher values. Left ventricular assist device flow measurements showed less temporal variability compared with CO. Grouping for simultaneous measured blood pressure (BP < 60, 60-70, 70-80, 80-90, and ≥90), the correlation of CO with LVAD flow differed (R = 0.42, 0.67, 0.48, 0.32, 0.32, respectively). Indicating better correlation when mean blood pressure is 60 to 70 mm Hg. Left ventricular assist device flow generally trends with measured CO, but large variability exists, hence flow measures should not be assumed to equal with CO. Clinicians should take into account variables such as high CO, BP, and opening of the aortic valve when interpreting LVAD flow readout. Direct flow sensors incorporated in the LVAD system may allow for better estimation.


Asunto(s)
Gasto Cardíaco/fisiología , Corazón Auxiliar , Hemodinámica/fisiología , Femenino , Insuficiencia Cardíaca/cirugía , Humanos , Masculino , Persona de Mediana Edad , Termodilución
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...