Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Med Phys ; 47(9): 4531-4542, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32497267

RESUMEN

PURPOSE: Image-guided radiotherapy (IGRT) improves tumor control but its intensive use may entrain late side effects caused by the additional imaging doses. There is a need to better quantify the additional imaging doses, so they can be integrated in the therapeutic workflow. Currently, no dedicated software enables to compute patient-specific imaging doses on a wide range of systems and protocols. As a first step toward this objective, we propose a common methodology to model four different kV-imaging systems used in radiotherapy (Varian's OBI, Elekta's XVI, Brainlab's ExacTrac, and Accuray's Cyberknife) using a new type of virtual source model based on Monte Carlo calculations. METHODS: We first describe our method to build a simplified description of the photon output, or virtual source models (VSMs), of each imaging system. Instead of being constructed using measurement data, as it is most commonly the case, our VSM is used as the summary of the phase-space files (PSFs) resulting from a first Monte Carlo simulation of the considered x-ray tube. Second, the VSM is used as a photon generator for a second MC simulation in which we compute the dose. Then, the proposed VSM is thoroughly validated against standard MC simulation using PSFs on the XVI system. Last, each modeled system is compared to profiles and depth-dose-curve measurements performed in homogeneous phantom. RESULTS: Comparisons between PSF-based and VSM-based calculations highlight that VSMs could provide equivalent dose results (within 1% of difference) than PSFs inside the imaging field-of-view (FOV). In contrast, VSMs tend to underestimate (for up to 20%) calculated doses outside of the imaging FOV due to the assumptions underlying the VSM construction. In addition, we showed that the use of VSMs allows reducing calculation time by at least a factor of 2.8. Indeed, for identical simulation times, statistical uncertainties on dose distributions computed using VSMs were much lower than those obtained from PSF-based calculations. CONCLUSIONS: For each of the four imaging systems, VSMs were successfully validated against measurements in homogeneous phantoms, and are therefore ready to be used for future preclinical studies in heterogeneous or anthropomorphic phantoms. The cross system modeling methodology developed here should enable, later on, to estimate precisely and accurately patient-specific 3D dose maps delivered during a large range of kV-imaging procedures.


Asunto(s)
Radioterapia Guiada por Imagen , Simulación por Computador , Humanos , Método de Montecarlo , Fantasmas de Imagen , Fotones , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
2.
IEEE Trans Med Imaging ; 33(10): 1913-30, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24876109

RESUMEN

Intra-operative imaging techniques for obtaining the shape and morphology of soft-tissue surfaces in vivo are a key enabling technology for advanced surgical systems. Different optical techniques for 3-D surface reconstruction in laparoscopy have been proposed, however, so far no quantitative and comparative validation has been performed. Furthermore, robustness of the methods to clinically important factors like smoke or bleeding has not yet been assessed. To address these issues, we have formed a joint international initiative with the aim of validating different state-of-the-art passive and active reconstruction methods in a comparative manner. In this comprehensive in vitro study, we investigated reconstruction accuracy using different organs with various shape and texture and also tested reconstruction robustness with respect to a number of factors like the pose of the endoscope as well as the amount of blood or smoke present in the scene. The study suggests complementary advantages of the different techniques with respect to accuracy, robustness, point density, hardware complexity and computation time. While reconstruction accuracy under ideal conditions was generally high, robustness is a remaining issue to be addressed. Future work should include sensor fusion and in vivo validation studies in a specific clinical context. To trigger further research in surface reconstruction, stereoscopic data of the study will be made publically available at www.open-CAS.com upon publication of the paper.


Asunto(s)
Imagenología Tridimensional/métodos , Laparoscopía/métodos , Cirugía Asistida por Computador/métodos , Animales , Endoscopios , Riñón/anatomía & histología , Riñón/cirugía , Hígado/anatomía & histología , Hígado/cirugía , Modelos Biológicos , Reproducibilidad de los Resultados , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...