Front Cardiovasc Med ; 10: 1332868, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38292455

RESUMEN

Background: Catheter ablation (CA) for symptomatic atrial fibrillation (AF) offers the best outcomes for patients. Despite the benefits of CA, a significant proportion of patients suffer a recurrence; hence, there is scope to potentially improve outcomes through technical innovations such as ablation index (AI) guidance during AF ablation. We present real-world 5-year follow-up data of AI-guided pulmonary vein isolation. Methods: We retrospectively followed 123 consecutive patients who underwent AI-guided CA shortly after its introduction to routine practice. Data were collected from the MPH AF Ablation Registry with the approval of the institutional research board. Results: Our patient cohort was older, with higher BMI, greater CHA2DS2-VASc scores, and larger left atrial sizes compared to similar previously published cohorts, while gender balance and other characteristics were similar. The probability of freedom from atrial arrhythmia with repeat procedures is as follows: year 1: 0.95, year 2: 0.92, year 3: 0.85, year 4: 0.79, and year 5: 0.72. Age >75 years (p = 0.02, HR: 2.7, CI: 1.14-6.7), BMI >35 kg/m2 (p = 0.0009, HR: 4.6, CI: 1.8-11.4), and left atrial width as measured on CT in the upper quartile (p = 0.04, HR: 2.5, CI: 1-5.7) were statistically significant independent predictors of recurrent AF. Conclusion: AI-guided CA is an effective treatment for AF, with 95.8% of patients remaining free from atrial arrhythmia at 1 year and 72.3% at 5 years, allowing for repeat procedures. It is safe with a low major complication rate of 1.25%. Age >75 years, BMI >35 kg/m2, and markedly enlarged atria were associated with higher recurrence rates.

2.
Indian Pacing Electrophysiol J ; 18(2): 56-60, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29111168

RESUMEN

BACKGROUND: Current algorithms and device morphology templates have been proposed in current Implantable Cardioverter-Defibrillators (ICDs) to minimize inappropriate therapies (ITS), but this has not been completely successful. AIM: Assess the impact of a deliberate strategy of using an atrial lead implant with standardized parameters; based on all current ICD discriminators and technologies, on the burden of ITS. METHOD: A retrospective single-centre analysis of 250 patients with either dual chamber (DR) ICDs or biventricular ICDs (CRTDs) over a (41.9 ± 27.3) month period was performed. The incidence of ITS on all ICD and CRTD patients was chronicled after the implementation of standardized programming. RESULTS: 39 events of anti-tachycardial pacing (ATP) and/or shocks were identified in 20 patients (8% incidence rate among patients). The total number of individual therapies was 120, of which 34% were inappropriate ATP, and 36% were inappropriate shocks. 11 patients of the 250 patients received ITS (4.4%). Of the 20 patients, four had ICDs for primary prevention and 16 for a secondary prevention. All the episodes in the primary indication group were inappropriate, while seven patients (43%) of the secondary indication group experienced inappropriate therapies. CONCLUSIONS: The burden of ITS in the population of patients receiving ICDs was 4.4% in the presence of atrial leads. The proposed rationalized programming criteria seems an effective strategy to minimize the burden of inappropriate therapies and will require further validation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA