2.
BMC Pediatr ; 23(Suppl 2): 564, 2023 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-37968603

RESUMEN

BACKGROUND: Medical devices are critical to providing high-quality, hospital-based newborn care, yet many of these devices are unavailable in low- and middle-income countries (LMIC) and are not designed to be suitable for these settings. Target Product Profiles (TPPs) are often utilised at an early stage in the medical device development process to enable user-defined performance characteristics for a given setting. TPPs can also be applied to assess the profile and match of existing devices for a given context. METHODS: We developed initial TPPs for 15 newborn product categories for LMIC settings. A Delphi-like process was used to develop the TPPs. Respondents completed an online survey where they scored their level of agreement with each of the proposed performance characteristics for each of the 15 devices. Characteristics with < 75% agreement between respondents were discussed and voted on using Mentimeter™ at an in-person consensus meeting. FINDINGS: The TPP online survey was sent to 180 people, of which 103 responded (57%). The majority of respondents were implementers/clinicians (51%, 53/103), with 50% (52/103) from LMIC. Across the 15 TPPs, 403 (60%) of the 668 performance characteristics did not achieve > 75% agreement. Areas of disagreement were voted on by 69 participants at an in-person consensus meeting, with consensus achieved for 648 (97%) performance characteristics. Only 20 (3%) performance characteristics did not achieve consensus, most (15/20) relating to quality management systems. UNICEF published the 15 TPPs in April 2020, accompanied by a report detailing the online survey results and consensus meeting discussion, which has been viewed 7,039 times (as of January 2023). CONCLUSIONS: These 15 TPPs can inform developers and enable implementers to select neonatal care products for LMIC. Over 2,400 medical devices and diagnostics meeting these TPPs have been installed in 65 hospitals in Nigeria, Tanzania, Kenya, and Malawi through the NEST360 Alliance. Twenty-three medical devices identified and qualified by NEST360 meet nearly all performance characteristics across 11 of the 15 TPPs. Eight of the 23 qualified medical devices are available in the UNICEF Supply Catalogue. Some developers have adjusted their technologies to meet these TPPs. There is potential to adapt the TPP process beyond newborn care.


Asunto(s)
Naciones Unidas , Recién Nacido , Humanos , Kenia , Malaui , Nigeria , Tanzanía
3.
PLOS Glob Public Health ; 3(8): e0002262, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37552665

RESUMEN

Neonatal jaundice is an important cause of morbidity and mortality worldwide, and neonates born in low and middle-income countries bear a disproportionate burden. We previously developed a low-cost, point-of-care system to measure total serum bilirubin (TSB) in neonates. This device was effective at detecting and monitoring jaundice; however, the disposable strips were difficult to produce at scale. Here, we report a new lateral flow cassette design, called BiliDx, that was produced at scale using traditional manufacturing techniques. We evaluated the performance of BiliDx at sites in Nigeria and Malawi. The lateral flow strip consists of plasma separation membranes, nitrocellulose, and a plastic cassette. We evaluated the performance of the strips and reader at two hospitals located in Nigeria and Malawi compared to reference standard TSB. We also assessed performance for samples with high direct bilirubin (DB) and high hematocrit (HCT). We collected 1,144 samples from 758 neonates (TSB ranged from 0.2 to 45.9 mg/dL). The mean bias of BiliDx measurements in the validation set was +0.75 mg/dL, and 95% limits of agreement were -2.57 to 4.07 mg/dL. The mean bias and limits of agreement were comparable for samples with HCT < 60% and HCT ≥ 60%, and for samples with low and intermediate DB levels; the samples with high DB levels had wider 95% limits of agreement (-4.50 to +3.03 mg/dL). Error grid analysis shows that 96.9% of samples measured with BiliDx would have resulted in the same clinical decision as the reference standard. This performance is comparable to previous results that used a handmade two-dimensional strip. Additionally, error grid analysis shows that all 20 samples with high DB levels would have resulted in the same clinical decision as the reference standard. This evaluation supports the use of BiliDx lateral flow cassettes to provide accurate point-of-care measurements in low-resource settings.

4.
Pediatrics ; 150(2)2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35799070

RESUMEN

OBJECTIVES: BiliSpec is a low-cost spectrophotometric reader and disposable paper-based strip to quantify total serum bilirubin from several blood drops. This study was a prospective evaluation of BiliSpec in 2 neonatal wards in Malawi compared with a reference standard bilirubinometer over a large range of bilirubin and hematocrit levels. METHODS: The accuracy of BiliSpec and a transcutaneous bilirubinometer were compared with the reference standard of spectrophotometry for 475 blood samples collected from 375 subjects across a range of total serum bilirubin concentrations from 0.0 to 33.7 mg/dL. The development of error grids to assess the clinical effects of measurement differences is reported. RESULTS: BiliSpec was found to have a mean bias of -0.48 mg/dL and 95% limits of agreement of -5.09 mg/dL to +4.12 mg/dL. Results show 90.7% of BiliSpec measurements would have resulted in the same clinical decision as the reference standard, whereas 55.0% of transcutaneous bilirubin measurements would have resulted in the same clinical decision as the reference standard. CONCLUSIONS: This evaluation supports use of BiliSpec to provide accurate, low-cost, point-of-care bilirubin measurements in low-resource hospitals. Future work is needed to evaluate BiliSpec among a larger number of users.


Asunto(s)
Bilirrubina , Ictericia Neonatal , Pruebas Hematológicas , Humanos , Recién Nacido , Malaui , Tamizaje Neonatal/métodos , Sistemas de Atención de Punto , Pruebas en el Punto de Atención
5.
Proc Natl Acad Sci U S A ; 114(51): E10965-E10971, 2017 12 19.
Artículo en Inglés | MEDLINE | ID: mdl-29203650

RESUMEN

Newborns are at increased risk of jaundice, a condition in which excess bilirubin accumulates in blood. Left untreated, jaundice can lead to neurological impairment and death. Jaundice resulting from unconjugated hyperbilirubinemia is easily treated with exposure to blue light, and phototherapy systems have been developed for low-resource settings; however, there are no appropriate solutions to diagnose and monitor jaundice in these settings. To address this need we present BiliSpec, a low-cost reader and disposable lateral flow card designed to measure the concentration of total bilirubin from several drops of blood at the point of care. We evaluated the performance of BiliSpec, using blood from normal volunteers spiked with varying amounts of bilirubin; results measured using BiliSpec correlated well with a reference laboratory bilirubinometer (r = 0.996). We then performed a pilot clinical study using BiliSpec to measure total bilirubin in neonates at risk for jaundice at Queen Elizabeth Central Hospital in Blantyre, Malawi. Concentrations measured using BiliSpec correlated well with those measured using a laboratory reference standard in 94 patient samples ranging from 1.1 mg/dL to 23.0 mg/dL in concentration (r = 0.973). The mean difference between bilirubin levels measured with BiliSpec and the reference standard was 0.3 mg/dL (95[Formula: see text] CI: -1.7-2.2 mg/dL).


Asunto(s)
Ictericia Neonatal/diagnóstico , Pruebas en el Punto de Atención , Femenino , Recursos en Salud , Humanos , Recién Nacido , Malaui , Masculino , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Reproducibilidad de los Resultados
6.
PLoS One ; 12(5): e0177732, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28520780

RESUMEN

A rapid test to identify patients with sickle cell disease could have important benefits in low-resource settings. Sickle cell anemia (SCA) affects about 300,000 newborns each year, the majority of whom are born in sub-Saharan Africa. Low-cost therapies are available to treat SCA, but most countries in sub-Saharan Africa lack robust neonatal screening programs needed to identify patients in need of treatment. To address this need, we developed and evaluated a competitive lateral flow assay that identifies patients with SCA (genotype HbSS) in 15 minutes using undiluted whole blood. A small volume of blood (0.5 µL- 3 µL) is mixed with antibody-coated blue latex beads in a tube and applied to the strip. Strips are then placed in a well of running buffer and allowed to run for 10 minutes. Laboratory evaluation with samples containing different proportions of hemoglobin A (HbA) and hemoglobin S (HbS) indicated that the test should enable identification of SCA patients but not persons with sickle cell trait (SCT). We evaluated the test using 41 samples from individuals with SCA, SCT, and normal blood. With visual inspection or quantitative analysis, we found a 98% accuracy when differentiating SCA from normal and SCT samples as a group (90% sensitivity and 100% specificity for identifying SCA). This work demonstrates important steps towards making a lateral flow test for hemoglobinopathies more appropriate for point-of-care use; further work is needed before the test is appropriate for clinical use.


Asunto(s)
Anemia de Células Falciformes/sangre , Pruebas en el Punto de Atención/economía , Pruebas Serológicas/métodos , África del Sur del Sahara , Anticuerpos Inmovilizados/inmunología , Hemoglobina Falciforme/inmunología , Humanos , Recién Nacido , Microesferas , Pruebas en el Punto de Atención/normas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Pruebas Serológicas/economía , Pruebas Serológicas/normas
7.
Am J Clin Pathol ; 144(6): 885-94, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26572995

RESUMEN

OBJECTIVES: Blood obtained via fingerprick is commonly used in point-of-care assays, but few studies have assessed variability in parameters obtained from successive drops of fingerprick blood, which may cause problems for clinical decision making and for assessing accuracy of point-of-care tests. METHODS: We used a hematology analyzer to analyze the hemoglobin concentration, total WBC count, three-part WBC differential, and platelet count in six successive drops of blood collected from one fingerprick from each of 11 donors, and we used a hemoglobinometer to measure the hemoglobin concentration of 10 drops of fingerprick blood from each of 7 donors. RESULTS: The average percent coefficient of variation (CV) for successive drops of fingerprick blood was higher by up to 3.4 times for hemoglobin, 5.7 times for WBC count, 3 times for lymphocyte count, 7.7 times for granulocyte count, and 4 times for platelets than in venous controls measured using a hematology analyzer. The average percent CV for fingerprick blood was up to 5 times higher for hemoglobin than venous blood measured using a point-of-care hemoglobinometer. Fluctuations in blood parameters with increasing volume of fingerprick blood are within instrument variability for volumes equal to or greater than 60 to 100 µL. CONCLUSIONS: These data suggest caution when using measurements from a single drop of fingerprick blood.


Asunto(s)
Recolección de Muestras de Sangre/normas , Pruebas Hematológicas/normas , Sistemas de Atención de Punto/normas , Dedos , Humanos , Proyectos Piloto , Reproducibilidad de los Resultados
8.
Health Innov Point Care Conf ; 2014: 267-270, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25918750

RESUMEN

Anemia, a condition characterized by insufficient hemoglobin, affects 56.2% of pregnant women and 66.1% of children under five in low-resource countries. Though hemoglobin concentration measurement is the most common laboratory test in the world, the high cost of disposables (>$1.00 per test in Malawi) limits its availability in these settings. We have demonstrated a spectrophotometric method that reduces the per-test cost of anemia diagnosis to under $0.01 by using chromatography paper as the only disposable. Improvements in the hand-held reader, including using laser modules and a reference photodiode, enabled repeatable results within and across devices. We evaluated this method by analyzing capillary blood samples from 70 patients in the pediatric ward of Queen Elizabeth Central Hospital, Blantyre, Malawi. ~90% of these samples were within 2 g/dL of the standard value, with higher accuracy on more anemic samples. Current work aims to improve this accuracy by converting the hemoglobin in the sample to the more stable form methemoglobin.

9.
Lab Chip ; 13(12): 2381-8, 2013 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-23652574

RESUMEN

Anemia affects a quarter of the world's population, and a lack of appropriate diagnostic tools often prevents treatment in low-resource settings. Though the HemoCue 201+ is an appropriate device for diagnosing anemia in low-resource settings, the high cost of disposables ($0.99 per test in Malawi) limits its availability. We investigated using spectrophotometric measurement of blood spotted on chromatography paper as a low-cost (<$0.01 per test) alternative to HemoCue cuvettes. For this evaluation, donor blood was diluted with plasma to simulate anemia, a micropipette spotted blood on paper, and a bench-top spectrophotometer validated the approach before the development of a low-cost reader. We optimized impregnating paper with chemicals to lyse red blood cells, paper type, drying time, wavelengths measured, and sensitivity to variations in volume of blood, and we validated our approach using patient samples. Lysing the blood cells with sodium deoxycholate dried in Whatman Chr4 chromatography paper gave repeatable results, and the absorbance difference between 528 nm and 656 nm was stable over time in measurements taken up to 10 min after sample preparation. The method was insensitive to the amount of blood spotted on the paper over the range of 5 µL to 25 µL. We created a low-cost, handheld reader to measure the transmission of paper cuvettes at these optimal wavelengths. Training and validating our method with patient samples on both the spectrometer and the handheld reader showed that both devices are accurate to within 2 g dL(-1) of the HemoCue device for 98% and 95% of samples, respectively.


Asunto(s)
Hemoglobinas/análisis , Espectrofotometría , Anemia/diagnóstico , Cromatografía en Papel , Pruebas con Sangre Seca , Eritrocitos/citología , Eritrocitos/metabolismo , Humanos , Sistemas de Atención de Punto