Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Tech Coloproctol ; 28(1): 34, 2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38369674

RESUMEN

BACKGROUND: In the decision to perform elective surgery, it is of great interest to have data about the outcomes of surgery to individualize patients who could safely undergo sigmoid resection. The aim of this study was to provide information on the outcomes of elective sigmoid resection for sigmoid diverticular disease (SDD) at a national level. METHODS: All consecutive patients who had elective surgery for SDD (2010-2021) were included in this retrospective, multicenter, cohort study. Patients were identified from institutional review board-approved databases in French member centers of the French Surgical Association. The endpoints of the study were the early and the long-term postoperative outcomes and an evaluation of the risk factors for 90-day severe postoperative morbidity and a definitive stoma after an elective sigmoidectomy for SDD. RESULTS: In total, 4617 patients were included. The median [IQR] age was 61 [18.0;100] years, the mean ± SD body mass index (BMI) was 26.8 ± 4 kg/m2, and 2310 (50%) were men. The indications for surgery were complicated diverticulitis in 50% and smoldering diverticulitis in 47.4%. The procedures were performed laparoscopically for 88% and with an anastomosis for 83.8%. The severe complication rate on postoperative day 90 was 11.7%, with a risk of anastomotic leakage of 4.7%. The independent risk factors in multivariate analysis were an American Society of Anesthesiologists (ASA) score ≥ 3, an open approach, and perioperative blood transfusion. Age, perioperative blood transfusion, and Hartmann's procedure were the three independent risk factors for a permanent stoma. CONCLUSIONS: This series provides a real-life picture of elective sigmoidectomy for SDD at a national level. TRIAL REGISTRATION: Comité National Information et Liberté (CNIL) (n°920361).


Asunto(s)
Diverticulitis del Colon , Diverticulitis , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Estudios de Cohortes , Colon Sigmoide/cirugía , Diverticulitis/cirugía , Diverticulitis/complicaciones , Diverticulitis del Colon/cirugía , Diverticulitis del Colon/complicaciones , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano
4.
Ann Chir ; 126(9): 876-80, 2001 Nov.
Artículo en Francés | MEDLINE | ID: mdl-11760579

RESUMEN

STUDY AIM: The aim of this retrospective study was to describe an unusual complication of the nonabsorbable meshes used for repair of incisional hernia or inguinal hernia. PATIENTS AND METHODS: This study included eight observations of intestinal fistulas that occurred between 1 and 13 years after using Mersilène (Dacron) mesh for repair of an incisional hernia (7 cases) and an inguinal hernia (1 case). There were 6 men and 2 women (mean age: 58 years, range: 35-85 years) with an external intestinal fistula (n = 6) or an internal intestinal fistula (n = 2). All the patients required a reoperation for extraction of the mesh and treatment of the bowel injuries. RESULTS: There was one secondary death in a 85 years old woman in relation with a vascular complication after incomplete excision of the prosthesis. In five patients out of six, there was a recurrence of the incisional hernia. CONCLUSION: The intestinal fistulas associated with prosthetic repair of the abdominal wall are mostly observed with intraperitoneal mesh but this factor is not exclusive. Their frequency after repair of incisional or inguinal hernia with non absorbable mesh is estimated between 0.3 and 3.5%. The use of nonabsorbable mesh should be limited to the indications of strict necessity, without any septic context or emergency surgery. The contact of the mesh with the bowel should be formally avoided.


Asunto(s)
Hernia Inguinal/cirugía , Fístula Intestinal/etiología , Mallas Quirúrgicas/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Procedimientos Quirúrgicos del Sistema Digestivo , Femenino , Humanos , Fístula Intestinal/patología , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Retrospectivos , Factores de Tiempo
5.
Ann Chir ; 125(10): 982-4, 2000 Dec.
Artículo en Francés | MEDLINE | ID: mdl-11195929

RESUMEN

The vacuum-assisted closure (VAC) system is used for the treatment of complicated wounds and large tissular dehiscences. The study aim was to report a case of perineal gangrene extended to the abdominal wall in a 53-year old woman. After several extensive surgical debridments, using of the VAC was followed by a good and rapid healing of the wound.


Asunto(s)
Músculos Abdominales/patología , Músculos Abdominales/cirugía , Perineo/patología , Perineo/cirugía , Femenino , Gangrena/terapia , Humanos , Persona de Mediana Edad , Procedimientos Quirúrgicos Operativos/métodos , Vacio
6.
Ann Chir ; 53(7): 571-6, 1999.
Artículo en Francés | MEDLINE | ID: mdl-10520495

RESUMEN

The authors report a series of 149 cases of incisional hernia, operated between 1983 and 1993, by insertion of a non-absorbable prosthetic mesh within the intraperitoneal cavity. This series consisted of 93 women and 56 men, with a mean age 57 years. One third of repairs were performed because of primary treatment failure. One or more operative risk factors were present in 127 patients. A non-absorbable intraperitoneal prosthetic mesh was inserted with tension to allow good musculo-aponeurotic repair. Postoperative mortality was 0.6%. All but 13 of the patients, were reviewed with a mean follow-up of 83 months. Twenty eight patients (20%) developed recurrence. In 8 cases, the cause of recurrence was failure of prosthetic mesh insertion because of excessive tension. Three patients (1.7%) developed a fistula in contact with the prosthetic mesh, that had to be removed. A small bowel fistula was observed in 2 cases after an intraoperative wound in 1 case, and a colonic fistula in 1 case. The results of incisional hernia repair with nonabsorbable intraperitoneal prosthetic mesh can be compared with these of other techniques using prosthetic materials. This technique does not require dissection of the intermediate planes and avoids undermining which causes substantial bleeding. The risk of sepsis is also decreased by deep placement of the prosthesis. The exceptional cases of fistula or the possibility of migration of the prosthesis are not exclusively observed with this technique, but must clearly encourage a very strict aseptic technique, with placement of omentum between the prosthetic mesh and the viscera.


Asunto(s)
Hernia Ventral/cirugía , Complicaciones Posoperatorias/cirugía , Prótesis e Implantes , Mallas Quirúrgicas , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Epiplón/cirugía , Peritoneo/cirugía , Tereftalatos Polietilenos , Prótesis e Implantes/efectos adversos , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Mallas Quirúrgicas/efectos adversos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...