Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Meat Sci ; 91(1): 79-87, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22265369

RESUMEN

Fat entering food during frying needs to be monitored to control the nutritional properties of the products: fat penetration and fatty acid (FA) composition. The large difference between the apparent diffusion coefficients of lipids and meat fibers allows the use of diffusion-weighted magnetic resonance imaging (DWI) to measure oil uptake profiles. This method, in association with analysis of FAs by gas-liquid chromatography, predicts nutritional changes. Beef samples from finishing cows given control feed or high FA supplemented feed were fried in olive oil at 130 °C and 180 °C. Frying oil penetration was quantified by computing oil signal profiles from 3D DWI. Oil penetration was deeper at 180 °C (5 mm) than at 130 °C (2.5 mm), consistent with oil penetration processes. Oil penetration evaluated with DWI was correlated (R²=0.82) with biochemical analysis of FA composition. These results highlight the predominance of oil uptake over animal feed effects in the first millimeters of in-plane fried meat.


Asunto(s)
Culinaria/métodos , Ácidos Grasos/análisis , Carne/análisis , Aceites de Plantas/química , Adsorción , Alimentación Animal/análisis , Animales , Bovinos , Difusión , Aceite de Linaza/administración & dosificación , Imagen por Resonancia Magnética , Modelos Químicos , Aceite de Oliva , Extractos Vegetales/administración & dosificación , Extractos Vegetales/química , Polifenoles/administración & dosificación , Propiedades de Superficie , Vitamina E/administración & dosificación
2.
Neurochirurgie ; 52(1): 15-25, 2006 Feb.
Artículo en Francés | MEDLINE | ID: mdl-16609656

RESUMEN

The subthalamic nucleus (STN) is the main target of deep brain stimulation (DBS) treatment for severe idiopathic Parkinson's disease. But there is still no clear information on the location of the effective contacts (used during the chronic phase of stimulation). Our aim was to assess the anatomical structures of the subthalamic area (STA) involved during chronic DBS. Ten patients successfully treated were included. The surgical procedure was based on direct STN targeting (stereotactic MRI based) pondered by the acute effects of intraoperative stimulation. We used a formaldehyde-fixed human specimen to compare by matching MRI images obtained at 1.5 Tesla (performed in clinical stereotactic conditions) and at very high field at 4.7 Tesla. This allowed accurate analysis of the anatomy of the STA and retrospective precision of the location of the center of effective contacts which were located within the STN in 4 patients, at the interface between the STN and the ZI and/or FF in 13, at the interface between ZI and FF in 2 and between the STN and the substantia nigra in one. These results were consistent with the literature, revealing the implication of neighboring structures, especially the zona incerta and Forel's Field, in the clinical benefit.


Asunto(s)
Estimulación Encefálica Profunda , Electrodos Implantados , Imagen por Resonancia Magnética , Enfermedad de Parkinson/terapia , Técnicas Estereotáxicas , Núcleo Subtalámico/patología , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Examen Neurológico , Enfermedad de Parkinson/patología , Enfermedad de Parkinson/fisiopatología , Sustancia Negra/patología , Sustancia Negra/fisiopatología , Núcleo Subtalámico/fisiopatología , Subtálamo/patología , Subtálamo/fisiopatología , Resultado del Tratamiento
3.
Artículo en Inglés | MEDLINE | ID: mdl-16537177

RESUMEN

Information that can be obtained by magnetic resonance imaging (MRI) of explanted endovascular devices must be validated as this method is non-destructive. Histology of such a device together with its encroached tissues can be elegantly performed after polymethymethacrylate (PMMA) embedding, but this approach requires destruction of the specimen. The issue is therefore to determine if the MRI is sufficient to fully validate an explanted device based upon the characterization of an explanted specimen. An AneuRx device deployed percutaneously 25 months earlier in a 75-year-old patient was removed en bloc at autopsy together with the surrounding aneurysmal sac and segments of the upstream and downstream arteries. Macroscopic pictures were taken and a slice of the cross-section was processed for histology after polymethylmethacrylate (PMMA) embedding. For the magnetic resonance imaging investigation, the device was inserted in a Biospec 4.7 T MRI system with a 20 mm diameter birdcage resonator used for both emission and reception. A Spin-Echo (SE) was used to acquire both T1 proton density (PD) and T2 weighted images. A gradient-echo (GE) sampling of a free induction decay (GESFID) was used to generate multiple GE images using a single excitation pulse so that four images at different TE were obtained in the same acquisition. The selected explanted device was outstandingly well-healed compared to most devices harvested from humans. No inflammatory process was observed in contact or at distance of the materials. In MRI T1 images display no specific contrast and were homogeneous in the different tissues. The contrast was improved on proton density weighed images. On the T2 weighed images, the different areas were well identified. The diffusion images displayed in the surrounding B region had the greatest diffusion coefficient and the greatest anisotropy. The MRI analysis of the explanted AneuRx device illustrates the possibilities of this technique to characterize the interaction of the endovascular graft with the surrounding tissues. MRI is a breakthrough to investigate explanted medical devices but it also can be advantageously used in vivo to obtain virtual biopsies, because real biopsies to determine the 3 Bs (biocompatibility, biofunctionality and bioresilience) cannot be carried out as they could obviously initiate infection and degradation of the foreign materials.


Asunto(s)
Arterias/patología , Biopsia/métodos , Imagen por Resonancia Magnética/métodos , Stents , Anciano , Arterias/química , Humanos , Masculino , Microscopía , Polimetil Metacrilato/química
4.
J Agric Food Chem ; 53(10): 3986-94, 2005 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-15884828

RESUMEN

Fermentation of dough made from standard flour for French breadmaking was followed by nuclear magnetic resonance imaging at 9.4 T. The growth of bubbles (size > 117 microm) was observed for dough density between 0.8 and 0.22 g cm(-3). Cellular structure was assessed by digital image analysis, leading to the definition of fineness and rate of bubble growth. Influence of composition was studied through fractionation by extraction of soluble fractions (6% db), by defatting (< 1% db) and by puroindolines (Pin) addition (< or = 0.1%). Addition of the soluble fraction increased the dough specific volume and bubble growth rate but decreased fineness, whereas defatting and Pin addition only increased fineness. The role of molecular components of each fraction could be related to dough elongational properties. A final comparison with baking results confirmed that the crumb cellular structure was largely defined after fermentation.


Asunto(s)
Pan/análisis , Fermentación , Harina/análisis , Imagen por Resonancia Magnética , Aire , Manipulación de Alimentos/métodos , Tecnología de Alimentos , Gases , Solubilidad
5.
Int J Sports Med ; 23(8): 604-9, 2002 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-12439778

RESUMEN

The purpose of this study was to compare the effects of two protocols of electrical stimulation combined with voluntary contractions on the recovery of thigh muscles after anterior cruciate ligament (ACL) surgery. Ten sportsmen with a mean age of 26 yrs were randomly assigned into two groups: a 80 Hz stimulated group (5 patients) and a 20 Hz stimulated group (5 patients). All patients received electrical stimulation of the quadriceps femoris, five days a week, for 12 weeks, and had a standard program of voluntary contractions. Muscle and fat volumes of the thigh were assessed using MRI before surgery and after 12 weeks of rehabilitation. Quadriceps and hamstring muscle strength were evaluated by isokinetic measurements. Twelve weeks after surgery, the quadriceps peak torque deficit in the operated limb with respect to the non operated limb at 180 degrees /s and 240 degrees /s was significantly (p < 0.05) less in the 20 Hz group than in the 80 Hz group. This difference was not confirmed when comparing the pre-surgery quadriceps peak torque of the operated limb with the post-surgery one. Subcutaneous fat volume was increased for the two groups at the post-surgery test. This increase was significantly (p < 0.05) greater for the 80 Hz group. Thigh muscle volume deficit was not significantly different between the two groups.


Asunto(s)
Ligamento Cruzado Anterior/cirugía , Terapia por Estimulación Eléctrica/métodos , Traumatismos de la Rodilla/rehabilitación , Músculo Esquelético/fisiopatología , Muslo/fisiopatología , Tejido Adiposo/fisiopatología , Adulto , Humanos , Traumatismos de la Rodilla/cirugía , Imagen por Resonancia Magnética , Masculino , Distribución Aleatoria , Recuperación de la Función , Torque
6.
Magn Reson Imaging ; 18(9): 1125-8, 2000 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11118767

RESUMEN

Tracking susceptibility effects is a convenient way to detect small inclusions in a bulk tissue matrix by MRI. We propose a quantitative assessment of these susceptibility effects by simultaneously mapping T(2)* and magnetic field from the time course of magnitude and phase using a multiple GE sequence at 4.7 T. A high-pass scheme is also introduced to highlight the mesoscopic magnetic field variations due to local susceptibility differences specifically in the magnetic field map. Applying this method to muscle tissue, we demonstrate that connective tissue generates detectable susceptibility effects through concomitant local magnetic field variation and T(2)* shortening.


Asunto(s)
Tejido Conectivo/anatomía & histología , Imagen por Resonancia Magnética/métodos , Músculo Esquelético/anatomía & histología , Tejido Adiposo/anatomía & histología , Algoritmos , Animales , Bovinos , Aumento de la Imagen , Magnetismo , Análisis de Regresión
7.
J Magn Reson Imaging ; 12(3): 488-96, 2000 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-10992317

RESUMEN

Fat and water fractions were quantified at high field using a chemical shift-selective inversion recovery (CSS-IR) sequence to address the major difficulties encountered at high field by phase-sensitive techniques used for fat/water discrimination. Water- and fat-suppressed images were perfectly registered, which is a prerequisite for quantification. Immunity of the inversion pulse to B(1) field modulations and off-resonance effects was tested for two adiabatic inversion pulses, with hyperbolic secant and asymmetric hyper-pulse waveforms. Taking into account adiabaticity, immunity to off-resonance, radiofrequency power requirements, and specific absorption rate, the former was chosen. A close correlation was found between fat content measured by CSS-IR at 4.7 T (R(2)= 0.97, P < 0.001) and 9.4 T (R(2)= 0.99, P < 0.05) and that measured by Soxhlet extraction. Different sources of bias (low signal-to-noise ratio, magnetization transfer effect) are discussed. J. Magn. Reson. Imaging 2000;12:488-496.


Asunto(s)
Lípidos/análisis , Imagen por Resonancia Magnética/métodos , Agua/análisis , Tejido Adiposo/química , Animales , Bovinos , Magnetismo , Modelos Teóricos , Músculo Esquelético/química , Análisis de Regresión , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
Eur J Appl Physiol ; 81(4): 329-36, 2000 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-10664093

RESUMEN

The present study assessed daily activity, physical capacity and body composition in 11 initially sedentary healthy subjects [5 men and 6 women, mean age 62.8 (SD 2.7) years] before training (T(o)), after completion of 7 (T(7w)) and 14 (T(14w)) weeks of training, and again 6 (T(6m)) and 12 (T(12m)) months after training. The mean daily activity index decreased from T(7w) to T(12m) reaching a lower level than at T(o) [T(12m) - T(o) = -1.5 (SD 4.6) units, P = 0.18]. Mean maximal oxygen uptake (VO(2max)) and its corresponding mean power output (Wdot(max)) were increased by 12.5 (SD 6.6)% (P = 0. 003) and 22.8 (SD 12.8)% (P = 0.003), respectively, at T(14w), and returned to their T(o) levels within 1 year. Mean body mass (m(b)) remained stable until T(6m) but increased significantly by 2.6 (SD 3. 7)% from T(6m) to T(12m) (P < 0.05). Mean fat mass (m(f), from bioelectrical impedance analysis measurements) tended to decrease [-2.0 (SD 4.2)%, P = 0.10] during the training period but increased by 7.8 (SD 10.9)% between T(6m) and T(12m) (P < 0.05). The mean fat free mass did not vary during the study period (P = 0.81) but magnetic resonance imaging (MRI) showed that mean thigh muscle volume decreased between T(7w) and T(12m) to less than at T(o) [T(12m) - T(o) = -2.3 (SD 3.6)%, P = 0.05]. Therefore, this study confirmed the favourable effects of endurance training on the physical capacity and body composition of elderly people, but demonstrated that the training programme would have to be continued to maintain the training-related benefits (i.e. increased VO(2max) and Wdot(max)) which would otherwise be lost within 1 year. After training, m(b) and m(f) were found to be increased. Furthermore, a fast and reproducible MRI protocol was validated for study of small intra-individual variations in tissue volumes in longitudinal studies.


Asunto(s)
Envejecimiento/fisiología , Resistencia Física/fisiología , Aptitud Física/fisiología , Tejido Adiposo/fisiología , Anciano , Composición Corporal , Ejercicio Físico/fisiología , Femenino , Humanos , Imagen por Resonancia Magnética/normas , Masculino , Persona de Mediana Edad , Músculo Esquelético/fisiología , Reproducibilidad de los Resultados , Muslo/fisiología , Factores de Tiempo
9.
Magn Reson Imaging ; 16(2): 167-73, 1998.
Artículo en Inglés | MEDLINE | ID: mdl-9508273

RESUMEN

Magnetic resonance imaging has been used to characterize muscle fiber types. Here, T1 and T2 values were determined in pure slow-twitch and fast-twitch rabbit muscles and in rabbit muscles with mixed fiber types. The muscles with high proportions of oxidative slow-twitch fibers had higher T2 values than the others. Echo time, orientation of muscle fibers in B0, and moving spins had no effect on relaxation parameters. The results are discussed in terms of slow myosin isoform content and oxidative metabolism.


Asunto(s)
Imagen por Resonancia Magnética , Fibras Musculares Esqueléticas/citología , Adenosina Trifosfatasas/análisis , Animales , Citrato (si)-Sintasa/análisis , Miembro Posterior , Histocitoquímica , L-Lactato Deshidrogenasa/análisis , Fibras Musculares de Contracción Rápida/citología , Fibras Musculares de Contracción Rápida/enzimología , Fibras Musculares Esqueléticas/enzimología , Fibras Musculares de Contracción Lenta/citología , Fibras Musculares de Contracción Lenta/enzimología , Músculo Esquelético/anatomía & histología , Conejos
10.
Magn Reson Med ; 36(2): 287-93, 1996 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-8843383

RESUMEN

An optimal maximum likelihood (ML) method is described for an unbiased estimation of monoexponential T2 from magnitude spin-echo images. The algorithm is based on a Gaussian assumption of noise distribution. The validity of this assumption was checked by a statistical chi 2 test on spin-echo and fast low-angle shot surface coil images. Monte-Carlo simulations of magnitude data showed that the ML estimate standard deviation is lower than that produced by a weighted least-squares fitting on signal logarithm. Correction schemes are proposed to reduce bias deriving from magnitude reconstruction. The variance of the ML estimate converged rapidly toward the theoretical algebraic expression of the Cramér-Rao lower bound.


Asunto(s)
Funciones de Verosimilitud , Imagen por Resonancia Magnética , Modelos Teóricos , Método de Montecarlo
11.
Comput Med Imaging Graph ; 17(4-5): 345-50, 1993.
Artículo en Inglés | MEDLINE | ID: mdl-8306308

RESUMEN

A method to model the left ventricular myocardium in thallium-201 Single Photon Emission Computed Tomography (SPECT) is presented. This method is based on the fitting of the morphological skeleton of the left ventricle to a truncated bullet. This automatic approach would provide a more reproducible visualization of the organ for clinical applications.


Asunto(s)
Corazón/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Radioisótopos de Talio , Tomografía Computarizada de Emisión de Fotón Único/métodos , Gráficos por Computador , Simulación por Computador , Femenino , Corazón/anatomía & histología , Ventrículos Cardíacos/anatomía & histología , Humanos , Masculino , Modelos Anatómicos
12.
Eur J Nucl Med ; 19(12): 1032-7, 1992.
Artículo en Inglés | MEDLINE | ID: mdl-1464355

RESUMEN

A new method for centering and reorienting automatically the left ventricle in thallium-201 myocardial single photon emission computed tomography (SPET) is proposed. The processing involves the following steps: (a) the transverse sections of the left ventricle are segmented, (b) the three-dimensional skeleton of the left ventricle is extracted using tools of mathematical morphology, (c) the skeleton is fitted to a quadratic surface by the least-squares method, (d) the left ventricle is reoriented and centered using the long axis and the coordinates of the centre of the quadratic surface. A series of 30 consecutive exercise and redistribution 201Tl SPET studies were centered and reoriented by two operators twice with this method, and twice manually. There was no significant difference in the mean realignment performed by the automatic and the manual methods while centering differed moderately in some instances. In all cases and for all parameters, the reproducibility of the automatic method was 1.00, while it ranged between 0.74 and 0.98 with the manual centering and reorientation. This automatic approach provides a fast and highly reproducible method for the reconstruction of short- and long-axis sections of the left ventricle in 201Tl SPET.


Asunto(s)
Corazón/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Radioisótopos de Talio , Tomografía Computarizada de Emisión de Fotón Único/métodos , Adulto , Anciano , Femenino , Cardiopatías/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Función Ventricular Izquierda/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA