Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Radiologie (Heidelb) ; 63(6): 461-470, 2023 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-37171543

RESUMEN

The use of patient contact shielding provides an opportunity to reduce patient radiation exposure. Recently, the use has been the subject of controversy. The Radiation Protection Committee has published a recommendation on the use of patient radiation shields by considering the recent findings on dose savings but also the risks of incorrect use. In this article, a specification for the more frequently used types of X­ray examination is given, which describes whether and which radiation contact shielding should be used. This is accompanied by a rationale for the use or non-use of patient radiation protection agents. Problems and possible errors are explained, as well as how to deal with special situations such as pregnant women and children.


Asunto(s)
Exposición a la Radiación , Protección Radiológica , Niño , Humanos , Femenino , Embarazo , Radiología Intervencionista , Dosis de Radiación , Radiografía , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control
2.
Phys Med Biol ; 64(7): 075009, 2019 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-30856614

RESUMEN

Personalized dosimetry in computed tomography (CT) can be realized by a full Monte Carlo (MC) simulation of the scan procedure. Essential input data needed for the simulation are appropriate CT x-ray source models and a model of the patient's body which is based on the CT image. The purpose of this work is to develop comprehensive procedures for the determination of CT x-ray source models and their verification by comparison of calculated and measured dose distributions in physical phantoms. Mobile equipment together with customized software was developed and used for non-invasive determination of equivalent source models of CT scanners under clinical conditions. Standard and physical anthropomorphic CT dose phantoms equipped with real-time CT dose probes at five representative positions were scanned. The accumulated dose was measured during the scan at the five positions. ImpactMC, an MC-based CT dose software program, was used to simulate the scan. The necessary inputs were obtained from the scan parameters, from the equivalent source models and from the material-segmented CT images of the phantoms. 3D dose distributions in the phantoms were simulated and the dose values calculated at the five positions inside the phantom were compared to measured dose values. Initial results were obtained by means of a General Electric Optima CT 660 and a Toshiba (Canon) Aquilion ONE. In general, the measured and calculated dose values were within relative uncertainties that had been estimated to be less than 10%. The procedures developed were found to be viable and rapid. The procedures are applicable to any scanner type under clinical conditions without making use of the service mode with stationary x-ray tube position. Results show that the procedures are well suited for determining and verifying the equivalent source models needed for personalized CT dosimetry based on post-scan MC calculations.


Asunto(s)
Algoritmos , Fantasmas de Imagen , Medicina de Precisión , Radiometría/métodos , Tomógrafos Computarizados por Rayos X , Tomografía Computarizada por Rayos X/métodos , Humanos , Método de Montecarlo , Dosis de Radiación , Programas Informáticos
3.
Arch Gynecol Obstet ; 294(2): 239-43, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-26573013

RESUMEN

PURPOSE: To improve the outcome of fetuses with gastrochisis several studies evaluated prenatal predictors. But there are different guidelines established and therefore the prenatal care is not standardized. With our study we wanted to evaluate the outcome of fetuses with gastroschisis after modification of prenatal management strategies at the Department of Obstetrics and Gynecology of the University Hospital Münster. METHODS: In this explorative retrospective study of 39 fetuses with gastroschisis, we compare the clinical outcome between two management groups. In the first group (group 1, n = 14) prenatal indication for delivery was confirmed by a subjective evaluation of the small bowel diameter and the wall thickness without established cut-off values for these parameters. In the second group (group 2, n = 25) certain limits for the small bowel diameter (25 mm) and the wall thickness (2.5 mm) were used for fetal surveillance. RESULTS: Noticeable differences between the two groups regarding birth weight, weight centile, arterial pH, small bowel diameter, wall thickness, adverse bowel condition and re-operations could not be observed. In group 2, delivery was earlier (p = 0.011), and a lower rate of prenatal complications was observed (p = 0.016). CONCLUSION: To avoid adverse prenatal complications we recommend the observation of fetuses with gastroschisis by sonographic monitoring of the small bowel diameter and the wall thickness.


Asunto(s)
Gastrosquisis/diagnóstico por imagen , Enfermedades Intestinales/diagnóstico por imagen , Atención Prenatal/métodos , Ultrasonografía Prenatal/métodos , Femenino , Feto , Humanos , Intestino Delgado/diagnóstico por imagen , Embarazo , Estudios Retrospectivos , Ultrasonografía
4.
Radiat Prot Dosimetry ; 165(1-4): 57-61, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25802461

RESUMEN

In Germany, each site using ionising radiation in human medicine is assigned to a competent medical authority (CMA) for quality assurance. Duties of these CMAs are, e.g. the inspection of medical aspects of the use of X-rays and nuclear medicine at the sites as well as technical quality assurance of X-ray devices. The CMAs themselves have to report the collected exposure values to the ministries and the Federal Office for Radiation Protection. The IVEU (IT-gestütztes Verfahren zur Erfassung von Untersuchungsparametern) Software Framework assists CMAs and radiological departments in collecting and analysing data provided in DICOM headers.


Asunto(s)
Almacenamiento y Recuperación de la Información/normas , Exposición a la Radiación/análisis , Monitoreo de Radiación/normas , Radiografía/normas , Sistemas de Información Radiológica/normas , Programas Informáticos , Alemania , Garantía de la Calidad de Atención de Salud/normas , Protección Radiológica/normas
5.
Comput Math Methods Med ; 2011: 143480, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21461385

RESUMEN

Online-monitoring systems in intensive care are affected by a high rate of false threshold alarms. These are caused by irrelevant noise and outliers in the measured time series data. The high false alarm rates can be lowered by separating relevant signals from noise and outliers online, in such a way that signal estimations, instead of raw measurements, are compared to the alarm limits. This paper presents a clinical validation study for two recently developed online signal filters. The filters are based on robust repeated median regression in moving windows of varying width. Validation is done offline using a large annotated reference database. The performance criteria are sensitivity and the proportion of false alarms suppressed by the signal filters.


Asunto(s)
Algoritmos , Artefactos , Cuidados Críticos/métodos , Monitoreo Fisiológico/instrumentación , Sistemas en Línea/instrumentación , Procesamiento de Señales Asistido por Computador , Presión Sanguínea/fisiología , Alarmas Clínicas , Falla de Equipo , Reacciones Falso Positivas , Alemania , Frecuencia Cardíaca/fisiología , Humanos , Oxígeno/sangre , Sensibilidad y Especificidad
6.
Rofo ; 182(9): 773-9, 2010 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-20645221

RESUMEN

PURPOSE: Due to significant measuring inaccuracies that can occur under certain conditions, the use of electronic personal dosimeters in statutory measurements in X-ray diagnostics is currently legally restricted. The present study investigates the clinically relevant situations in which measurement errors of more then 20 % can be anticipated. MATERIALS AND METHODS: Four series of experiments were made, comparing the results of the electronic personal dosimeter EPD Mk2.3 to those of reference dosimeters (TLDs and diagnostic dosimeters). On the one hand, personal doses have been determined in the routine operation of controlled areas in various departments. On the other hand, measurements on phantoms have been conducted in extreme but realistic situations under radiation protection. Experiments were conducted in unweakened scattered radiation as well as in unattenuated and attenuated direct radiation. RESULTS: The tested electronic personal dosimeter type meets the requirements regarding measurement accuracy for "official" personal dosimeters in all of the examined clinically relevant scattered radiation fields. Only if exposed to radiation directly, an underestimation of the dose can occur and can be greater than 90 %. CONCLUSION: In the range of scattered radiation of diagnostic X-ray equipment, even in pulsed fields, the use of electronic personal dosimeters is reasonable. Considerable measurement errors can only arise in radiation fields that are not realistic under regular conditions and even in connection with most accidents.


Asunto(s)
Artefactos , Microcomputadores , Radiografía , Radiometría/instrumentación , Carga Corporal (Radioterapia) , Diseño de Equipo , Humanos , Fantasmas de Imagen , Protección Radiológica , Valores de Referencia , Dispersión de Radiación , Sensibilidad y Especificidad
7.
Nano Lett ; 7(9): 2753-7, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17696403

RESUMEN

We show how to change optically the distance between two protein-linked gold nanoparticles by Raman-induced motion of the linker protein. Rayleigh scattering spectroscopy of the coupled-particle plasmon allows us to compare the inter-nanoparticle distance of individual protein-linked gold nanoparticle dimers before and after surface-enhanced Raman scattering (SERS). We find that low-intensity (50 microW/microm2) laser light in resonance with the nanoparticle-dimer plasmon provokes a change of the inter-nanoparticle distance on the order of 0.5 nm whenever SERS from the proteins connecting the nanoparticles can be observed.


Asunto(s)
Oro/química , Micromanipulación/métodos , Nanoestructuras/química , Nanoestructuras/efectos de la radiación , Nanotecnología/métodos , Pinzas Ópticas , Espectrometría Raman/métodos , Cristalización/métodos , Relación Dosis-Respuesta en la Radiación , Oro/efectos de la radiación , Luz , Movimiento (Física) , Nanoestructuras/ultraestructura , Tamaño de la Partícula , Dosis de Radiación
8.
Br J Haematol ; 124(2): 240-3, 2004 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-14687036

RESUMEN

Acute chest syndrome (ACS) is a life-threatening complication of sickle cell disease (SCD). A retrospective study was performed to evaluate the role of endothelial nitric oxide synthase (eNOS) gene polymorphisms (E298D and T-786C) in African-American SCD patients. The D298 allele showed no association; the C-786 allele showed a statistically significant association (P = 0.0061) in female ACS cases. Multiple logistic regression analysis showed that relative risk of ACS was 8.695 (P = 0.0076, 95% confidence interval 1.761-42.920) for female carriers of C-786. eNOS T-786C is a gender-specific genetic modifier that is associated with increased susceptibility to ACS in female SCD patients.


Asunto(s)
Anemia de Células Falciformes/genética , Dolor en el Pecho/genética , Óxido Nítrico Sintasa/genética , Enfermedad Aguda , Adolescente , Adulto , Anciano , Femenino , Predisposición Genética a la Enfermedad , Genotipo , Humanos , Masculino , Persona de Mediana Edad , Óxido Nítrico Sintasa de Tipo III , Polimorfismo Genético/genética , Estudios Retrospectivos , Análisis de Secuencia de ADN , Síndrome
9.
J Synchrotron Radiat ; 8(Pt 2): 279-81, 2001 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-11512752

RESUMEN

K edge absorption spectra of elements from Ge to Br in gaseous hydrides were measured at the BM 29 station of ESRF with noise level as low as 2x10(-5), so far achievable only on noble gases. The dominant feature of the spectra is the atomic background similar to that of Kr and comparable to it in the quality of detail. Onto the background, a smooth weak EXAFS signal due to the hydrogen neighbors is superposed. For the very simple molecules such as these, its contribution can be calculated ab initio, with exact treatment of the effect of molecular vibrations, so that no best-fit adjustment to the experimental data is necessary. In comparison to the main constituent of the atomic background, i.e. the shake-up absorption edges, the EXAFS signal is of minor importance in HBr with a single H neighbor, but of the same order of magnitude in GeH4.

10.
J Synchrotron Radiat ; 8(Pt 2): 282-4, 2001 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-11512753

RESUMEN

From EXAFS spectra of As and As2O3 vapors and arsine gas AsH3 the ab initio calculated structural signal is removed. The remainders comprise small absorption edges due to shake-up channels involving electrons from 3d or 3p subshell. With enhanced resolution, the edges reveal a fine splitting and a varying contribution of resonance channels, due to individual molecular energy-level structure of the samples. On the resolution level appropriate for routine EXAFS analysis the remainders coincide, representing a unique and transferable atomic absorption background for the range of As valence states spanned by the samples.

11.
J Synchrotron Radiat ; 8(Pt 2): 522-4, 2001 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-11512837

RESUMEN

In order to complement the structural characterisation by high resolution electron microscopy and perturbed angular correlation spectroscopy (PAC) of Al2O3 coated nano-composite ZrO2, XAFS spectra have been acquired and analysed. The electron micrographs showed fringes of a well ordered lattice and well defined crystal faces of the as-produced powder whereas the PAC spectra indicated a strongly distorted short range order. On the basis of the XAFS data, a structural model for the ZrO2 core of the nano-composite ZrO2/Al2O3 with a well ordered Zr lattice and a sevenfold, strongly distorted nearest neighbour oxygen shell is proposed. A smooth temperature dependence without an indication for a phase transformation up to a temperature of 700K has been revealed.

12.
J Synchrotron Radiat ; 8(Pt 2): 666-8, 2001 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-11512889

RESUMEN

The short-range coordination of Nd(III) and Eu(III) ions in aqueous solutions has been investigated by means of K-edge x-ray absorption spectroscopy. Experimental data are presented which demonstrate that an accurate determination of the Nd(III) and Eu(III) hydration structural parameters can be obtained from the analysis of the K-edge spectra. It is shown that the large widths of the core hole states do not appreciably reduce the potential structural information of the K-edge EXAFS data. In addition the available k-range of the K-edge spectra is much wider compared to that of the L3-edge which is affected by the presence of double-electron excitations in a more severe fashion.

13.
J Synchrotron Radiat ; 8(Pt 2): 764-6, 2001 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-11512924

RESUMEN

We have performed high-quality X-ray absorption measurements on crystalline (c-Rb) and liquid (l-Rb) Rubidium in the range from 15 K to 320 K. Performing a consistent analysis that takes into account the contribution of the medium range structure, we observe that the l-Rb spectrum is compatible with pair correlation function g(r) previously determined by neutron diffraction experiments. Due to the micrometric size of the liquid droplets we were able to observe a slight undercooling down to 290 K. We were also able to study the details of the very strong multielectron excitations channels in terms of resonances, edges and shake-off features at proper theoretical energy values.

14.
J Synchrotron Radiat ; 8(Pt 2): 81-6, 2001 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-11512940

RESUMEN

Novel techniques and the experimental station for experiments on condensed matter under extreme conditions that have been developed at the BM29 beamline of the European Synchrotron Radiation Facility (ESRF) are described. The experimental setup includes facilities to collect high-quality extended X-ray absorption fine structure (EXAFS) spectra, to perform controlled temperature scans while monitoring the sample absorption for the direct detection of phase transitions, and to collect high-resolution energy-scanning X-ray diffraction (ESXD) data, with recent enhancements through the installation of a two-channel collimator detector system. Facilities for X-ray absorption temperature scans, introduced five years ago, are now exploited for a wide variety of purposes. A method for the measurement of the nucleation rate in undercooled liquids has been proposed recently. All these advances in the experimental setup and techniques, combined with a simple but rigorous X-ray absorption fine structure (XAFS) data analysis scheme for disordered matter, have contributed to make feasible challenging experiments on undercooled liquid matter that were not even conceivable only a few years ago. An example of the application of these methods to undercooled liquid indium (In) is presented.

15.
Proc Natl Acad Sci U S A ; 97(1): 365-70, 2000 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-10618424

RESUMEN

Fabry disease is a lysosomal storage disorder caused by a deficiency of the lysosomal enzyme alpha-galactosidase A (alpha-gal A). This enzymatic defect results in the accumulation of the glycosphingolipid globotriaosylceramide (Gb(3); also referred to as ceramidetrihexoside) throughout the body. To investigate the effects of purified alpha-gal A, 10 patients with Fabry disease received a single i.v. infusion of one of five escalating dose levels of the enzyme. The objectives of this study were: (i) to evaluate the safety of administered alpha-gal A, (ii) to assess the pharmacokinetics of i.v.-administered alpha-gal A in plasma and liver, and (iii) to determine the effect of this replacement enzyme on hepatic, urine sediment and plasma concentrations of Gb(3). alpha-Gal A infusions were well tolerated in all patients. Immunohistochemical staining of liver tissue approximately 2 days after enzyme infusion identified alpha-gal A in several cell types, including sinusoidal endothelial cells, Kupffer cells, and hepatocytes, suggesting diffuse uptake via the mannose 6-phosphate receptor. The tissue half-life in the liver was greater than 24 hr. After the single dose of alpha-gal A, nine of the 10 patients had significantly reduced Gb(3) levels both in the liver and shed renal tubular epithelial cells in the urine sediment. These data demonstrate that single infusions of alpha-gal A prepared from transfected human fibroblasts are both safe and biochemically active in patients with Fabry disease. The degree of substrate reduction seen in the study is potentially clinically significant in view of the fact that Gb(3) burden in Fabry patients increases gradually over decades. Taken together, these results suggest that enzyme replacement is likely to be an effective therapy for patients with this metabolic disorder.


Asunto(s)
Enfermedad de Fabry/enzimología , Trihexosilceramidas/metabolismo , alfa-Galactosidasa/uso terapéutico , Adulto , Enfermedad de Fabry/terapia , Humanos , Inmunohistoquímica , Hígado/citología , Hígado/enzimología , Masculino , Persona de Mediana Edad , Urinálisis , alfa-Galactosidasa/farmacocinética
16.
J Synchrotron Radiat ; 6(Pt 3): 179-81, 1999 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-15263240
18.
Pol Tyg Lek ; 51(14-18): 200-2, 1996 Apr.
Artículo en Polaco | MEDLINE | ID: mdl-8966157

RESUMEN

Six hundred laparoscopic cholecystectomies have been performed in patients with cholelithiasis. Co-existing chronic diseases have been noted in 28% of the operated patients. All these diseases have been known to increase operative risk in classic (open) cholecystectomy (hypertension, coronary disease, cardiac arrhythmias, diabetes mellitus, bronchial asthma). Statistical analysis of the body temperature following laparoscopic cholecystectomy, morbidity and duration of the postoperative hospitalization has revealed that there has been no significant increase in operative risk for laparoscopic cholecystectomy in these patients.


Asunto(s)
Asma/complicaciones , Enfermedades Cardiovasculares/complicaciones , Colecistectomía Laparoscópica , Colelitiasis/complicaciones , Colelitiasis/cirugía , Complicaciones de la Diabetes , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Temperatura Corporal , Colecistectomía Laparoscópica/efectos adversos , Enfermedad Crónica , Femenino , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Factores de Riesgo
19.
Biochem J ; 301 ( Pt 3): 727-35, 1994 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-8053898

RESUMEN

A mixture of ananain (EC 3.4.22.31) and comosain purified from crude pineapple stem extract was found to contain numerous closely related enzyme forms. Chromatographic separation of the major enzyme forms was achieved after treatment of the mixture with thiol-modifying reagents: reversible modification with 2-hydroxyethyl disulphide provided enzyme for kinetic studies, and irreversible alkylation with bromotrifluoroacetone or iodoacetamide gave enzyme for structural analyses by 19F-n.m.r. and electrospray mass spectrometry respectively. Structural and kinetic analyses revealed comosain to be closely related to stem bromelain (EC 3.4.22.32), whereas ananain differed markedly from both comosain and stem bromelain. Nevertheless, differences were seen between comosain and stem bromelain in amino acid composition and kinetic specificity towards the epoxide inhibitor E-64. Differences between five isolatable alternative forms of ananain were characterized by amidolytic activity, thiol stoichiometry and accurate mass determinations. Three of the enzyme forms displayed ananain-like amidolytic activity, whereas the other two forms were inactive. Thiol-stoichiometry determinations revealed that the active enzyme forms contained one free thiol, whereas the inactive forms lacked the reactive thiol required for enzyme activity. M.s. provided direct evidence for oxidation of the active-site thiol to the corresponding sulphinic acid.


Asunto(s)
Cisteína Endopeptidasas/aislamiento & purificación , Frutas/enzimología , Secuencia de Aminoácidos , Sitios de Unión , Bromelaínas/química , Bromuro de Cianógeno , Cisteína Endopeptidasas/química , Cisteína Endopeptidasas/metabolismo , Electroforesis en Gel de Poliacrilamida , Cinética , Datos de Secuencia Molecular , Fragmentos de Péptidos/química , Fragmentos de Péptidos/metabolismo , Análisis de Secuencia , Especificidad por Sustrato
20.
Wiad Lek ; 47(9-10): 371-6, 1994 May.
Artículo en Polaco | MEDLINE | ID: mdl-7817597

RESUMEN

The rules of three step therapy of chronic pain in terminal malignant has been presented. The need of priority of non narcotic drugs in retard form, oral or enteral administration and individual schedule out-pacing the occurring of pain has been stressed.


Asunto(s)
Neoplasias/complicaciones , Dolor/tratamiento farmacológico , Analgésicos/administración & dosificación , Enfermedad Crónica , Esquema de Medicación , Humanos , Dolor/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA