Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Sci Rep ; 14(1): 11810, 2024 05 23.
Artículo en Inglés | MEDLINE | ID: mdl-38782976

RESUMEN

In this retrospective study, we aimed to assess the objective and subjective image quality of different reconstruction techniques and a deep learning-based software on non-contrast head computed tomography (CT) images. In total, 152 adult head CT scans (77 female, 75 male; mean age 69.4 ± 18.3 years) obtained from three different CT scanners using different protocols between March and April 2021 were included. CT images were reconstructed using filtered-back projection (FBP), iterative reconstruction (IR), and post-processed using a deep learning-based algorithm (PS). Post-processing significantly reduced noise in FBP-reconstructed images (up to 15.4% reduction) depending on the protocol, leading to improvements in signal-to-noise ratio of up to 19.7%. However, when deep learning-based post-processing was applied to FBP images compared to IR alone, the differences were inconsistent and partly non-significant, which appeared to be protocol or site specific. Subjective assessments showed no significant overall improvement in image quality for all reconstructions and post-processing. Inter-rater reliability was low and preferences varied. Deep learning-based denoising software improved objective image quality compared to FBP in routine head CT. A significant difference compared to IR was observed for only one protocol. Subjective assessments did not indicate a significant clinical impact in terms of improved subjective image quality, likely due to the low noise levels in full-dose images.


Asunto(s)
Aprendizaje Profundo , Cabeza , Programas Informáticos , Tomografía Computarizada por Rayos X , Humanos , Femenino , Tomografía Computarizada por Rayos X/métodos , Masculino , Anciano , Cabeza/diagnóstico por imagen , Estudios Retrospectivos , Persona de Mediana Edad , Anciano de 80 o más Años , Procesamiento de Imagen Asistido por Computador/métodos , Relación Señal-Ruido , Adulto , Algoritmos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
2.
Diagnostics (Basel) ; 14(6)2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38535032

RESUMEN

Non-contrast computed tomography (CT) is commonly used for the evaluation of various pathologies including pulmonary infections or urolithiasis but, especially in low-dose protocols, image quality is reduced. To improve this, deep learning-based post-processing approaches are being developed. Therefore, we aimed to compare the objective and subjective image quality of different reconstruction techniques and a deep learning-based software on non-contrast chest and low-dose abdominal CTs. In this retrospective study, non-contrast chest CTs of patients suspected of COVID-19 pneumonia and low-dose abdominal CTs suspected of urolithiasis were analysed. All images were reconstructed using filtered back-projection (FBP) and were post-processed using an artificial intelligence (AI)-based commercial software (PixelShine (PS)). Additional iterative reconstruction (IR) was performed for abdominal CTs. Objective and subjective image quality were evaluated. AI-based post-processing led to an overall significant noise reduction independent of the protocol (chest or abdomen) while maintaining image information (max. difference in SNR 2.59 ± 2.9 and CNR 15.92 ± 8.9, p < 0.001). Post-processing of FBP-reconstructed abdominal images was even superior to IR alone (max. difference in SNR 0.76 ± 0.5, p ≤ 0.001). Subjective assessments verified these results, partly suggesting benefits, especially in soft-tissue imaging (p < 0.001). All in all, the deep learning-based denoising-which was non-inferior to IR-offers an opportunity for image quality improvement especially in institutions using older scanners without IR availability. Further studies are necessary to evaluate potential effects on dose reduction benefits.

3.
Neurooncol Adv ; 6(1): vdae022, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38516329

RESUMEN

Background: Primary central nervous system lymphomas (PCNSL) pose a challenge as they may mimic gliomas on magnetic resonance imaging (MRI) imaging, compelling precise differentiation for appropriate treatment. This study focuses on developing an automated MRI-based workflow to distinguish between PCNSL and gliomas. Methods: MRI examinations of 240 therapy-naive patients (141 males and 99 females, mean age: 55.16 years) with cerebral gliomas and PCNSLs (216 gliomas and 24 PCNSLs), each comprising a non-contrast T1-weighted, fluid-attenuated inversion recovery (FLAIR), and contrast-enhanced T1-weighted sequence were included in the study. HD-GLIO, a pre-trained segmentation network, was used to generate segmentations automatically. To validate the segmentation efficiency, 237 manual segmentations were prepared (213 gliomas and 24 PCNSLs). Subsequently, radiomics features were extracted following feature selection and training of an XGBoost algorithm for classification. Results: The segmentation models for gliomas and PCNSLs achieved a mean Sørensen-Dice coefficient of 0.82 and 0.80 for whole tumors, respectively. Three classification models were developed in this study to differentiate gliomas from PCNSLs. The first model differentiated PCNSLs from gliomas, with an area under the curve (AUC) of 0.99 (F1-score: 0.75). The second model discriminated between high-grade gliomas and PCNSLs with an AUC of 0.91 (F1-score: 0.6), and the third model differentiated between low-grade gliomas and PCNSLs with an AUC of 0.95 (F1-score: 0.89). Conclusions: This study serves as a pilot investigation presenting an automated virtual biopsy workflow that distinguishes PCNSLs from cerebral gliomas. Prior to clinical use, it is necessary to validate the results in a prospective multicenter setting with a larger number of PCNSL patients.

4.
Eur Radiol ; 34(1): 411-421, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37552254

RESUMEN

OBJECTIVES: Cardiac computed tomography (CT) is essential in diagnosing coronary heart disease. However, a disadvantage is the associated radiation exposure to the patient which depends in part on the scan range. This study aimed to develop a deep neural network to optimize the delimitation of scan ranges in CT localizers to reduce the radiation dose. METHODS: On a retrospective training cohort of 1507 CT localizers randomly selected from calcium scoring and angiography scans and acquired between 2010 and 2017, optimized scan ranges were delimited by two radiologists in consensus. A neural network was trained to reproduce the scan ranges and was tested on two randomly selected and independent validation cohorts: an internal cohort of 233 CT localizers (January 2018-June 2020) and an external cohort from a nearby hospital of 298 CT localizers (July 2020-December 2020). Localizers where a bypass surgery was visible were excluded. The effective radiation dose to the patient was simulated using a Monte Carlo simulation. Scan ranges of radiographers, radiologists, and the network were compared using an equivalence test; likewise, the reduction in effective dose was tested using a superior test. RESULTS: The network replicated the radiologists' scan ranges with a Dice score of 96.5 ± 0.02 (p < 0.001, indicating equivalence). The generated scan ranges resulted in an effective dose reduction of 10.0% (p = 0.002) in the internal cohort and 12.6% (p < 0.001) in the external cohort compared to the scan ranges delimited by radiographers in clinical routine. CONCLUSIONS: Automatic delimitation of the scan range can result in a radiation dose reduction to the patient. CLINICAL RELEVANCE STATEMENT: Fully automated delimitation of the scan range using a deep neural network enables a significant reduction in radiation exposure during CT coronary angiography compared to manual examination planning. It can also reduce the workload of the radiographers. KEY POINTS: • Scan range delimitation for coronary computed tomography angiography could be performed with high accuracy by a deep neural network. • Automated scan ranges showed a high agreement of 96.5% with the scan ranges of radiologists. • Using a Monte Carlo simulation, automated scan ranges reduced the effective dose to the patient by up to 12.6% (0.9 mSv) compared to the scan ranges of radiographers in clinical routine.


Asunto(s)
Aprendizaje Profundo , Exposición a la Radiación , Humanos , Angiografía Coronaria/métodos , Angiografía por Tomografía Computarizada/métodos , Dosis de Radiación , Estudios Retrospectivos , Exposición a la Radiación/prevención & control
5.
Sci Rep ; 13(1): 19010, 2023 11 03.
Artículo en Inglés | MEDLINE | ID: mdl-37923758

RESUMEN

In this retrospective study, we aimed to predict the body height and weight of pediatric patients using CT localizers, which are overview scans performed before the acquisition of the CT. We trained three commonly used networks (EfficientNetV2-S, ResNet-18, and ResNet-34) on a cohort of 1009 and 1111 CT localizers of pediatric patients with recorded body height and weight (between January 2013 and December 2019) and validated them in an additional cohort of 116 and 127 localizers (acquired in 2020). The best-performing model was then tested in an independent cohort of 203 and 225 CT localizers (acquired between January 2021 and March 2023). In addition, a cohort of 1401 and 1590 localizers from younger adults (acquired between January 2013 and December 2013) was added to the training set to determine if it could improve the overall accuracy. The EfficientNetV2-S using the additional adult cohort performed best with a mean absolute error of 5.58 ± 4.26 cm for height and 4.25 ± 4.28 kg for weight. The relative error was 4.12 ± 4.05% for height and 11.28 ± 12.05% for weight. Our study demonstrated that automated estimation of height and weight in pediatric patients from CT localizers can be performed.


Asunto(s)
Aprendizaje Profundo , Humanos , Niño , Adulto Joven , Estudios Retrospectivos , Estatura , Tomografía Computarizada por Rayos X
6.
Eur Radiol Exp ; 7(1): 24, 2023 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-37185930

RESUMEN

BACKGROUND: We investigated about optimization of contrast media (CM) dose or radiation dose in thoracoabdominal computed tomography angiography (CTA) by automated tube voltage selection (ATVS) system configuration and CM protocol adaption. METHODS: In six minipigs, CTA-optimized protocols were evaluated regarding objective (contrast-to-noise ratio, CNR) and subjective (6 criteria assessed by Likert scale) image quality. Scan parameters were automatically adapted by the ATVS system operating at 90-kV semi-mode and configured for standard, CM saving, or radiation dose saving (image task, quality settings). Injection protocols (dose, flow rate) were adapted manually. This approach was tested for normal and simulated obese conditions. RESULTS: Radiation exposure (volume-weighted CT dose index) for normal (obese) conditions was 2.4 ± 0.7 (5.0 ± 0.7) mGy (standard), 4.3 ± 1.1 (9.0 ± 1.3) mGy (CM reduced), and 1.7 ± 0.5 (3.5 ± 0.5) mGy (radiation reduced). The respective CM doses for normal (obese) settings were 210 (240) mgI/kg, 155 (177) mgI/kg, and 252 (288) mgI/kg. No significant differences in CNR (normal; obese) were observed between standard (17.8 ± 3.0; 19.2 ± 4.0), CM-reduced (18.2 ± 3.3; 20.5 ± 4.9), and radiation-saving CTAs (16.0 ± 3.4; 18.4 ± 4.1). Subjective analysis showed similar values for optimized and standard CTAs. Only the parameter diagnostic acceptability was significantly lower for radiation-saving CTA compared to the standard CTA. CONCLUSIONS: The CM dose (-26%) or radiation dose (-30%) for thoracoabdominal CTA can be reduced while maintaining objective and subjective image quality, demonstrating the feasibility of the personalization of CTA scan protocols. KEY POINTS: • Computed tomography angiography protocols could be adapted to individual patient requirements using an automated tube voltage selection system combined with adjusted contrast media injection. • Using an adapted automated tube voltage selection system, a contrast media dose reduction (-26%) or radiation dose reduction (-30%) could be possible.


Asunto(s)
Angiografía por Tomografía Computarizada , Medios de Contraste , Animales , Porcinos , Angiografía por Tomografía Computarizada/métodos , Porcinos Enanos , Tomografía Computarizada por Rayos X/métodos , Dosis de Radiación
7.
Sci Rep ; 13(1): 4336, 2023 03 16.
Artículo en Inglés | MEDLINE | ID: mdl-36928759

RESUMEN

The aim of the study was to evaluate the impact of the newly developed Similar patient search (SPS) Web Service, which supports reading complex lung diseases in computed tomography (CT), on the diagnostic accuracy of residents. SPS is an image-based search engine for pre-diagnosed cases along with related clinical reference content ( https://eref.thieme.de ). The reference database was constructed using 13,658 annotated regions of interest (ROIs) from 621 patients, comprising 69 lung diseases. For validation, 50 CT scans were evaluated by five radiology residents without SPS, and three months later with SPS. The residents could give a maximum of three diagnoses per case. A maximum of 3 points was achieved if the correct diagnosis without any additional diagnoses was provided. The residents achieved an average score of 17.6 ± 5.0 points without SPS. By using SPS, the residents increased their score by 81.8% to 32.0 ± 9.5 points. The improvement of the score per case was highly significant (p = 0.0001). The residents required an average of 205.9 ± 350.6 s per case (21.9% increase) when SPS was used. However, in the second half of the cases, after the residents became more familiar with SPS, this increase dropped to 7%. Residents' average score in reading complex chest CT scans improved by 81.8% when the AI-driven SPS with integrated clinical reference content was used. The increase in time per case due to the use of the SPS was minimal.


Asunto(s)
Enfermedades Pulmonares , Pilotos , Humanos , Enfermedades Raras , Lectura , Tomografía Computarizada por Rayos X/métodos , Enfermedades Pulmonares/diagnóstico por imagen , Inteligencia Artificial
8.
Dtsch Arztebl Int ; 120(9): 135-141, 2023 03 13.
Artículo en Inglés | MEDLINE | ID: mdl-36633449

RESUMEN

BACKGROUND: Computed tomography (CT) studies are requested by specialists from most medical disciplines and play a vital role in the diagnosis and treatment of patients. It follows that physicians of all specialties should possess basic knowledge of computed tomography, its proper use, and the radiation exposure associated with it. METHODS: This review is based on publications retrieved by a selective search of the literature. RESULTS: Approximately 12 million CT studies are carried out in Germany each year, and the trend is rising. Approximately 9% of all diagnostic studies involving ionizing radiation are CT studies. On average, more than 60% of the collective effective dose due to medical radiation exposure is attributable to CT. There are two types of radiation effects caused by ionizing radiation: sto - chastic and deterministic. The additional, individual relative lifetime cancer mortality risk due to ionizing radiation with wholebody exposure at a low single dose is estimated at 5% per sievert. Radiation exposure from CT studies of the head and trunk, e.g. of a patient with polytrauma, corresponds to an additional lifetime cancer mortality risk of approximately 0.1% at an effective dose of approximately 20 millisievert. CONCLUSION: The radiation exposure due to CT, and the risks to which patients are subjected by it, have become more important with greater use of CT. Technical advances, targeted dose monitoring, and analyses of dose data can help identify areas where improvement is necessary, in furtherance of the overriding goal of lowering patients' radiation exposure while preserving adequate image quality.


Asunto(s)
Neoplasias Inducidas por Radiación , Exposición a la Radiación , Humanos , Dosis de Radiación , Medición de Riesgo , Neoplasias Inducidas por Radiación/etiología , Exposición a la Radiación/efectos adversos , Tomografía Computarizada por Rayos X/efectos adversos
9.
Neuroradiology ; 65(3): 637-644, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36418556

RESUMEN

PURPOSE: Endovascular treatment of unruptured intracranial aneurysms (UIAs) requires a risk-benefit analysis and adherence to diagnostic reference levels (DRLs). The national DRL (250 Gy·cm2) is only determined for intracranial aneurysm coiling in general, including ruptured intracranial aneurysms (RIAs). This study aims to investigate the dose in the treatment of UIAs and RIAs separately. METHODS: In a retrospective study design, dose area product (DAP) and fluoroscopy time (FT) were assessed for all patients undergoing intracranial aneurysm coiling between 2010 and 2021. DRL was set as the 75th percentile of the dose distribution. A multivariable linear regression analysis was performed to investigate DAP and FT for the two groups, UIA and RIA adjusted for patient age, aneurysm size, and location. RESULTS: 583 (414 females, mean age 56.5 years, 311 UIAs) are included. In the overall population, DAP (median (IQR)) is 157 Gy·cm2 (108-217) with a median FT of 32.7 min (IQR 24.0-47.0). Local DRL is 183 Gy·cm2 for UIAs and 246 Gy·cm2 for RIAs. After adjustment for the other variables, the UIA and RIA groups have a significant effect on both DAP (p < 0.001; 95% CI - 68.432 - - 38.040) and FT (p < 0.001; 95% CI - 628.279 - - 291.254). In general, both DAP and FT increase significantly with patient age and aneurysm size, whereas the location of the aneurysm did not significantly change neither DAP (p = 0.171; 95% CI - 5.537-31.065) nor FT (p = 0.136; 95% CI - 357.391-48.508). CONCLUSION: Both aneurysm size and patient age were associated with increased DAP, whereas aneurysm location did not significantly change DAP or FT. The increased dose in patients with RIAs is likely equivalent to additional diagnostic cerebral four-vessel angiography performed in this group.


Asunto(s)
Aneurisma Roto , Aneurisma Intracraneal , Femenino , Humanos , Persona de Mediana Edad , Aneurisma Intracraneal/diagnóstico , Estudios Retrospectivos , Fluoroscopía , Dosis de Radiación
10.
Diagnostics (Basel) ; 14(1)2023 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-38201337

RESUMEN

The aim of this study is to examine the precision of semi-automatic, conventional and automatic volumetry tools for pulmonary nodules in chest CT with phantom N1 LUNGMAN. The phantom is a life-size anatomical chest model with pulmonary nodules representing solid and subsolid metastases. Gross tumor volumes (GTVis) were contoured using various approaches: manually (0); as a means of semi-automated, conventional contouring with (I) adaptive-brush function; (II) flood-fill function; and (III) image-thresholding function. Furthermore, a deep-learning algorithm for automatic contouring was applied (IV). An intermodality comparison of the above-mentioned strategies for contouring GTVis was performed. For the mean GTVref (standard deviation (SD)), the interquartile range (IQR)) was 0.68 mL (0.33; 0.34-1.1). GTV segmentation was distributed as follows: (I) 0.61 mL (0.27; 0.36-0.92); (II) 0.41 mL (0.28; 0.23-0.63); (III) 0.65 mL (0.35; 0.32-0.90); and (IV) 0.61 mL (0.29; 0.33-0.95). GTVref was found to be significantly correlated with GTVis (I) p < 0.001, r = 0.989 (III) p = 0.001, r = 0.916, and (IV) p < 0.001, r = 0.986, but not with (II) p = 0.091, r = 0.595. The Sørensen-Dice indices for the semi-automatic tools were 0.74 (I), 0.57 (II) and 0.71 (III). For the semi-automatic, conventional segmentation tools evaluated, the adaptive-brush function (I) performed closest to the reference standard (0). The automatic deep learning tool (IV) showed high performance for auto-segmentation and was close to the reference standard. For high precision radiation therapy, visual control, and, where necessary, manual correction, are mandatory for all evaluated tools.

11.
J Radiol Prot ; 42(3)2022 09 28.
Artículo en Inglés | MEDLINE | ID: mdl-36067741

RESUMEN

90Y radioembolisation (RE) is an angiographic procedure used in patients with both primary and secondary hepatic malignancies. Local tumour control can be achieved by short range tumour irradiation by the regional intra-arterial administration of glass or resin microspheres loaded with 90yttrium that accumulate in the tumorous tissue. The aim of this study was to investigate the radiation exposure of RE and to establish a local diagnostic reference level (DRL). In this retrospective study, dose data from 397 procedures in 306 patients (mean age 67.4 ± 10.6 years, 82 female) who underwent RE between 06/2017 and 01/2022 using one of two different angiography systems were analysed. DRL was set as the 75th percentile of the dose distribution. In the overall population, dose area product (DAP) (median (interquartile range, IQR)) was 26 Gy cm2(IQR 12-50) with a median fluoroscopy time (FT) of 4.5 min (IQR 2.9-8.0). FT and DAP increased significantly with the number of infusion positions (median, IQR): one position 23 Gy cm2(12-46), two positions 33 Gy cm2(14-60), three positions 50 Gy cm2(24-82) (p< 0.0001). Local DRL is 47 Gy cm2for RE and 111 Gy cm2for RE with additional embolisation. Radiation exposure and FT are significantly higher with increasing number of infusion positions as well as additional embolisation. Our established DRLs for RE may serve as a benchmark for dose optimisation.


Asunto(s)
Angiografía , Niveles de Referencia para Diagnóstico , Anciano , Femenino , Fluoroscopía , Humanos , Persona de Mediana Edad , Dosis de Radiación , Estudios Retrospectivos
12.
J Radiol Prot ; 42(3)2022 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-35790148

RESUMEN

Computed tomography (CT)-guided percutaneous biopsies play an important role in the diagnostic workup of liver lesions. Because radiation dose accumulates rapidly due to repeated image acquisition in a relatively small scan area, analysing radiation exposure is critical for improving radiation protection of CT-guided interventions. The aim of this study was to assess the radiation dose of CT-guided liver biopsies and the influence of lesion parameters, and to establish a local diagnostic reference level (DRL). In this observational retrospective cohort study, dose data of 60 CT-guided liver biopsies between September 2016 and July 2017 were analysed. Radiation exposure was reported for volume-weighted CT dose index (CTDIvol), size-specific dose estimate (SSDE), dose-length product (DLP) and effective dose (ED). Radiation dose of CT-guided liver biopsy was (median (interquartile range)): CTDIvol9.91 mGy (8.33-11.45 mGy), SSDE 10.42 mGy (9.39-11.70 mGy), DLP 542 mGy cm (410-733 mGy cm), ED 8.52 mSv (7.17-13.25 mSv). Radiation exposure was significantly higher in biopsies of deep liver lesions compared to superficial lesions (DLP 679 ± 285 mGy cm vs. 497 ± 167 mGy cm,p= 0.0046). No significant dose differences were observed for differences in lesion or needle size. With helical CT spirals additional to the biopsy-guiding axial CT scans, radiation exposure was significantly increased: 797 ± 287 mGy cm vs. 495 ± 162 mGy cm,p< 0.0001. The local DRL is CTDIvol9.91 mGy, DLP 542 mGy cm. Radiation dose is significantly increased in biopsies of deeper liver lesions compared with superficial lesions. Interventions with additional biopsy-guiding CT spirals lead to higher radiation doses. This study provides a detailed analysis of local radiation doses for CT-guided liver biopsies and provides a benchmark for optimising radiation protection in interventional radiology.


Asunto(s)
Neoplasias Hepáticas , Exposición a la Radiación , Humanos , Biopsia Guiada por Imagen , Dosis de Radiación , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
13.
Pediatr Radiol ; 52(8): 1446-1455, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35378606

RESUMEN

BACKGROUND: Radiation exposures from computed tomography (CT) in children are inadequately studied. Diagnostic reference levels (DRLs) can help optimise radiation doses. OBJECTIVE: To determine local DRLs for paediatric chest CT performed mainly on modern dual-source, multi-slice CT scanners as a function of patient size. MATERIALS AND METHODS: Five hundred thirty-eight chest CT scans in 345 children under 15 years (y) of age (median age: 8 y, interquartile range [IQR]: 4-13 y) performed on four different CT scanners (38% on third-generation and 43% on second-generation dual-source CT) between November 2013 and December 2020 were retrospectively analysed. Examinations were grouped by water-equivalent diameter as a measure of patient size. DRLs for volume CT dose index (CTDIvol) and dose-length product (DLP) were determined for six different patient sizes and compared to national and European DRLs. RESULTS: The DRLs for CTDIvol and DLP are determined for each patient size group as a function of water-equivalent diameter as follows: (I) < 13 cm (n = 22; median: age 7 months): 0.4 mGy, 7 mGy·cm; (II) 13 cm to less than 17 cm (n = 151; median: age 3 y): 1.2 mGy, 25 mGy·cm; (III) 17 cm to less than 21 cm (n = 211; median: age 8 y): 1.7 mGy, 44 mGy·cm; (IV) 21 cm to less than 25 cm (n = 97; median: age 14 y): 3.0 mGy, 88 mGy·cm; (V) 25 cm to less than 29 cm (n = 42; median: age 14 y): 4.5 mGy, 135 mGy·cm; (VI) ≥ 29 cm (n = 15; median: age 14 y): 8.0 mGy, 241 mGy·cm. Compared with corresponding age and weight groups, our size-based DRLs for DLP are 54% to 71% lower than national and 23% to 85% lower than European DRLs. CONCLUSION: We developed DRLs for paediatric chest CT as a function of patient size with substantially lower values than national and European DRLs. Precise knowledge of size-based DRLs may assist other institutions in further dose optimisation in children.


Asunto(s)
Niveles de Referencia para Diagnóstico , Tomografía Computarizada por Rayos X , Adolescente , Niño , Preescolar , Humanos , Lactante , Dosis de Radiación , Valores de Referencia , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Agua
14.
Cardiovasc Intervent Radiol ; 45(6): 841-845, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35437708

RESUMEN

PURPOSE: In uveal melanoma patients, liver metastases can be treated by hepatic artery infusion chemotherapy (HAIC). During this procedure, melphalan or, less frequently, fotemustine is infused into the hepatic artery or the hepatic lobe arteries in regularly repeated interventions to achieve local tumor control. The aim of this study was to investigate the radiation exposure of HAIC. MATERIAL AND METHODS: In this retrospective study, dose data from 841 procedures in 140 patients (mean age 65.3 ± 9.9 years, 74 female) who underwent HAIC between 06/2017 and 10/2021 at one of three different angiography systems were analyzed. RESULTS: In the overall population, dose area product (DAP) (median (IQR)) was 1773 cGy·cm2 (884-3688). DAP was significantly higher in the first intervention, where a complete diagnostic workup of the vasculature was performed, than in follow-up interventions: 5765 cGy·cm2 (3160-8804) versus 1502 cGy·cm2 (807-2712) (p < 0.0001). DAP also increased significantly with the number of infusion positions (median, (IQR)): one position 1301 cGy·cm2 (633-2717), two positions 1985 cGy·cm2 (1118-4074), three positions 6407 cGy·cm2 (2616-11590) (p < 0.0001). CONCLUSION: In uveal melanoma patients with liver metastases undergoing HAIC, radiation exposure is significantly higher both at the first intervention compared to follow-up interventions, but also with increasing number of infusion positions.


Asunto(s)
Neoplasias Hepáticas , Neoplasias de la Úvea , Anciano , Femenino , Arteria Hepática/patología , Humanos , Infusiones Intraarteriales , Neoplasias Hepáticas/tratamiento farmacológico , Neoplasias Hepáticas/secundario , Melanoma , Persona de Mediana Edad , Dosis de Radiación , Estudios Retrospectivos , Neoplasias de la Úvea/tratamiento farmacológico
15.
Diagnostics (Basel) ; 12(2)2022 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-35204547

RESUMEN

According to a position paper of the European Commission Initiative on Breast Cancer (ECIBC), DBT is close to being introduced in European breast cancer screening programmes. Our study aimed to examine radiation dose delivered by digital breast tomosynthesis (DBT) and digital mammography (FFDM) in comparison to sole FFDM in a clinical follow-up setting and in an identical patient cohort. Retrospectively, 768 breast examinations of 96 patients were included. Patients received both DBT and FFDM between May 2015 and July 2019: (I) FFDM in cranio-caudal (CC) and DBT in mediolateral oblique (MLO) view, as well as a (II) follow-up examination with FFDM in CC and MLO view. The mean glandular dose (MGD) was determined by the mammography system according to Dance's model. The MGD (standard deviation (SD), interquartile range (IQR)) was distributed as follows: (I) (CCFFDM+MLODBT) (a) left FFDMCC 1.40 mGy (0.36 mGy, 1.13-1.59 mGy), left DBTMLO 1.62 mGy (0.51 mGy, 1.27-1.82 mGy); (b) right FFDMCC 1.36 mGy (0.34 mGy, 1.14-1.51 mGy), right DBTMLO 1.59 mGy (0.52 mGy, 1.27-1.62 mGy). (II) (CCFFDM+MLOFFDM) (a) left FFDMCC 1.35 mGy (0.35 mGy, 1.10-1.60 mGy), left FFDMMLO 1.40 mGy (0.39 mGy, 1.12-1.59 mGy), (b) right FFDMCC 1.35 mGy (0.33 mGy, 1.12-1.48 mGy), right FFDMMLO 1.40 mGy (0.36 mGy, 1.14-1.58 mGy). MGD was significantly higher for DBT mlo views compared to FFDM (p < 0.001). Radiation dose was significantly higher for DBT in MLO views compared to FFDM. However, the MGD of DBT MLO lies below the national diagnostic reference level of 2 mGy for an FFDM view. Hence, our results support the use of either DBT or FFDM as suggested in the ECIBC's Guidelines.

16.
J Radiol Prot ; 42(1)2022 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-34678799

RESUMEN

The selective intra-arterial nimodipine application for the treatment of cerebral vasospasm (CVS) in patients after spontaneous subarachnoid hemorrhage (sSAH) is widely employed. The purpose of this study is to examine the radiation exposure and to determine local diagnostic reference levels (DRLs) of intra-arterial nimodipine therapy. In a retrospective study design, DRLs and achievable dose (AD) were assessed for all patients undergoing (I) selective intra-arterial nimodipine application or (II) additional mechanical angioplasty for CVS treatment. Interventional procedures were differentiated according to the type of procedure and the number of probed vessels. Altogether 494 neurointerventional procedures of 121 patients with CVS due to sSAH could be included. The radiation exposure indices were distributed as follows: (I) DRL 74.3 Gy·cm2, AD 59.8 Gy·cm2; (II) DRL 128.3 Gy·cm2, AD 94.5 Gy·cm2. Kruskal-Wallis test confirmed significant dose difference considering the number of probed vessels (p< 0.001). The mean cumulative dose per patient was 254.9 Gy·cm2(interquartile range 88.6-315.6 Gy·cm2). The DRLs of intra-arterial nimodipine therapy are substantially lower compared with DRLs proposed for other therapeutic interventions, such as thrombectomy or aneurysm coiling. However, repeated therapy sessions are often required, bearing the potential risk of a cumulatively higher radiation exposure.


Asunto(s)
Exposición a la Radiación , Hemorragia Subaracnoidea , Vasoespasmo Intracraneal , Humanos , Nimodipina , Exposición a la Radiación/efectos adversos , Estudios Retrospectivos , Hemorragia Subaracnoidea/tratamiento farmacológico , Resultado del Tratamiento , Vasodilatadores/uso terapéutico , Vasoespasmo Intracraneal/tratamiento farmacológico , Vasoespasmo Intracraneal/etiología
17.
Eur Radiol ; 32(3): 1971-1982, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34642811

RESUMEN

OB JECTIVES: The European Society of Radiology identified 10 common indications for computed tomography (CT) as part of the European Study on Clinical Diagnostic Reference Levels (DRLs, EUCLID), to help standardize radiation doses. The objective of this study is to generate DRLs and median doses for these indications using data from the UCSF CT International Dose Registry. METHODS: Standardized data on 3.7 million CTs in adults were collected between 2016 and 2019 from 161 institutions across seven countries (United States of America (US), Switzerland, Netherlands, Germany, UK, Israel, Japan). DRLs (75th percentile) and median doses for volumetric CT-dose index (CTDIvol) and dose-length product (DLP) were assessed for each EUCLID category (chronic sinusitis, stroke, cervical spine trauma, coronary calcium scoring, lung cancer, pulmonary embolism, coronary CT angiography, hepatocellular carcinoma (HCC), colic/abdominal pain, appendicitis), and US radiation doses were compared with European. RESULTS: The number of CT scans within EUCLID categories ranged from 8,933 (HCC) to over 1.2 million (stroke). There was greater variation in dose between categories than within categories (p < .001), and doses were significantly different between categories within anatomic areas. DRLs and median doses were assessed for all categories. DRLs were higher in the US for 9 of the 10 indications (except chronic sinusitis) than in Europe but with a significantly higher sample size in the US. CONCLUSIONS: DRLs for CTDIvol and DLP for EUCLID clinical indications from diverse organizations were established and can contribute to dose optimization. These values were usually significantly higher in the US than in Europe. KEY POINTS: • Registry data were used to create benchmarks for 10 common indications for CT identified by the European Society of Radiology. • Observed US radiation doses were higher than European for 9 of 10 indications (except chronic sinusitis). • The presented diagnostic reference levels and median doses highlight potentially unnecessary variation in radiation dose.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Adulto , Niveles de Referencia para Diagnóstico , Humanos , Dosis de Radiación , Valores de Referencia , Sistema de Registros , Tomografía Computarizada por Rayos X
18.
Neuroradiology ; 64(3): 587-595, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34570252

RESUMEN

PURPOSE: This study aims to determine local diagnostic reference levels (DRLs) in the endovascular therapy (EVT) of patients with cranial and spinal dural arteriovenous fistula (dAVF). METHODS: In a retrospective study design, DRLs and achievable dose (AD) were assessed for all patients with cranial and spinal dAVF undergoing EVT (I) or diagnostic angiography (II). All procedures were performed at the flat-panel angiography-system Allura Xper (Philips Healthcare). Interventional procedures were differentiated according to the region of fistula and the type of procedure. RESULTS: In total, 264 neurointerventional procedures of 131 patients with dAVF (94 cranial, 37 spinal) were executed between 02/2010 and 12/2020. The following DRLs, AD, and mean values could be determined: for cranial dAVF (I) DRL 507.33 Gy cm2, AD 369.79 Gy cm2, mean 396.51 Gy cm2; (II) DRL 256.65 Gy cm2, AD 214.19 Gy cm2, mean 211.80 Gy cm2; for spinal dAVF (I) DRL 482.72 Gy cm2, AD 275.98 Gy cm2, mean 347.12 Gy cm2; (II) DRL 396.39 Gy cm2, AD 210.57 Gy cm2, mean 299.55 Gy cm2. Dose levels of EVT were significantly higher compared to diagnostic angiographies (p < 0.001). No statistical difference in dose levels regarding the localization of dAVF was found. CONCLUSION: Our results could be used for establishing DRLs in the EVT of cranial and spinal dAVF. Because radiation exposure to comparably complex interventions such as AVM embolization is similar, it may be useful to determine general DRLs for both entities together.


Asunto(s)
Malformaciones Vasculares del Sistema Nervioso Central , Embolización Terapéutica , Procedimientos Endovasculares , Exposición a la Radiación , Malformaciones Vasculares del Sistema Nervioso Central/diagnóstico por imagen , Malformaciones Vasculares del Sistema Nervioso Central/terapia , Embolización Terapéutica/métodos , Procedimientos Endovasculares/métodos , Humanos , Estudios Retrospectivos , Cráneo
19.
Acta Radiol ; 63(4): 527-535, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33745295

RESUMEN

BACKGROUND: In the assessment of diseases causing skeletal lesions such as multiple myeloma (MM), whole-body low-dose computed tomography (WBLDCT) is a sensitive diagnostic imaging modality, which has the potential to replace the conventional radiographic survey. PURPOSE: To optimize radiation protection and examine radiation exposure, and effective and organ doses of WBLDCT using different modern dual-source CT (DSCT) devices, and to establish local diagnostic reference levels (DRL). MATERIAL AND METHODS: In this retrospective study, 281 WBLDCT scans of 232 patients performed between January 2017 and April 2020 either on a second- (A) or third-generation (B) DSCT device could be included. Radiation exposure indices and organ and effective doses were calculated using a commercially available automated dose-tracking software based on Monte-Carlo simulation techniques. RESULTS: The radiation exposure indices and effective doses were distributed as follows (median, interquartile range): (A) second-generation DSCT: volume-weighted CT dose index (CTDIvol) 1.78 mGy (1.47-2.17 mGy); dose length product (DLP) 282.8 mGy·cm (224.6-319.4 mGy·cm), effective dose (ED) 1.87 mSv (1.61-2.17 mSv) and (B) third-generation DSCT: CTDIvol 0.56 mGy (0.47-0.67 mGy), DLP 92.0 mGy·cm (73.7-107.6 mGy·cm), ED 0.61 mSv (0.52-0.69 mSv). Radiation exposure indices and effective and organ doses were significantly lower with third-generation DSCT (P < 0.001). Local DRLs could be set for CTDIvol at 0.75 mGy and DLP at 120 mGy·cm. CONCLUSION: Third-generation DSCT requires significantly lower radiation dose for WBLDCT than second-generation DSCT and has an effective dose below reported doses for radiographic skeletal surveys. To ensure radiation protection, DRLs regarding WBLDCT are required, where our locally determined values may help as benchmarks.


Asunto(s)
Mieloma Múltiple/diagnóstico por imagen , Exposición a la Radiación/estadística & datos numéricos , Tomografía Computarizada por Rayos X/métodos , Imagen de Cuerpo Entero/métodos , Niveles de Referencia para Diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Estudios Retrospectivos
20.
Radiology ; 302(2): 380-389, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34751618

RESUMEN

Background Lack of standardization in CT protocol choice contributes to radiation dose variation. Purpose To create a framework to assess radiation doses within broad CT categories defined according to body region and clinical imaging indication and to cluster indications according to the dose required for sufficient image quality. Materials and Methods This was a retrospective study using Digital Imaging and Communications in Medicine metadata. CT examinations in adults from January 1, 2016 to December 31, 2019 from the University of California San Francisco International CT Dose Registry were grouped into 19 categories according to body region and required radiation dose levels. Five body regions had a single dose range (ie, extremities, neck, thoracolumbar spine, combined chest and abdomen, and combined thoracolumbar spine). Five additional regions were subdivided according to dose. Head, chest, cardiac, and abdomen each had low, routine, and high dose categories; combined head and neck had routine and high dose categories. For each category, the median and 75th percentile (ie, diagnostic reference level [DRL]) were determined for dose-length product, and the variation in dose within categories versus across categories was calculated and compared using an analysis of variance. Relative median and DRL (95% CI) doses comparing high dose versus low dose categories were calculated. Results Among 4.5 million examinations, the median and DRL doses varied approximately 10 times between categories compared with between indications within categories. For head, chest, abdomen, and cardiac (3 266 546 examinations [72%]), the relative median doses were higher in examinations assigned to the high dose categories than in examinations assigned to the low dose categories, suggesting the assignment of indications to the broad categories is valid (head, 3.4-fold higher [95% CI: 3.4, 3.5]; chest, 9.6 [95% CI: 9.3, 10.0]; abdomen, 2.4 [95% CI: 2.4, 2.5]; and cardiac, 18.1 [95% CI: 17.7, 18.6]). Results were similar for DRL doses (all P < .001). Conclusion Broad categories based on image quality requirements are a suitable framework for simplifying radiation dose assessment, according to expected variation between and within categories. © RSNA, 2021 See also the editorial by Mahesh in this issue.


Asunto(s)
Dosis de Radiación , Tomografía Computarizada por Rayos X , Adulto , Anciano , Femenino , Humanos , Masculino , Metadatos , Persona de Mediana Edad , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...