Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Asunto principal
Intervalo de año de publicación
1.
J Med Imaging Radiat Sci ; 52(3): 427-434, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33958315

RESUMEN

PURPOSE: The goal of the study is to determine the inter-rater agreement on multiple factors that were utilized to evaluate the quality of pediatric chest X-ray exams from different levels of healthcare provision in an African setting. METHODS: The image quality of pediatric chest X-rays from 3 South African medical centers of varying level of healthcare service were retrospectively assessed by 3 raters for 12 quality factors including: (1) absent body parts; (2) under inspiration; (3) patient rotation; (4) scapula in the way; (5) patient kyphosis/lordosis; (6) artefact/foreign body; (7) central vessel visualization; (8) peripheral vessels visualization; (9) poor collimation; and (10) trachea and bronchi visualization; (11) post-cardiac vessel visualization; and (12) absent or wrong image orientation. Analysis was performed using the Brennan--Prediger coefficient of agreement for inter-rater reliability and Cochran's Q statistic and McNemar's test for inter-rater bias. RESULTS: 1077 X-rays were reviewed. The least difference between observers in the frequency of the errors was noticed for factors (1) absent body parts and (12) absent or wrong image orientation with almost perfect agreement between raters. κ score for these two factors among all raters and between each pair of raters was more than 0.95 with no significant inter-rater bias. Conversely, there was poor agreement for the remaining factors with the least agreed on being factor (3) patient rotation with a κ score of 0.23. This was followed by factors (2) under inspiration (κ score of 0.32) and factors (4) scapula in the way (κ score of 0.35) respectively. There was significant inter-rater bias for all these three factors. CONCLUSION: Many of the factors used to assess the quality of a chest X-ray in children demonstrate poor reliability despite mitigation against variations in training, standard quality definitions and level of healthcare service provision. New definitions, objective measures and recording tools for assessing pediatric chest radiographic quality are required.


Asunto(s)
Rayos X , Niño , Humanos , Variaciones Dependientes del Observador , Radiografía , Reproducibilidad de los Resultados , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA