Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Ultrasound Med ; 43(5): 829-840, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38205972

RESUMEN

OBJECTIVE: The consequences associated with blood clots are numerous and are responsible for many deaths worldwide. The assessment of treatment efficacy is necessary for patient follow-up and to detect treatment-resistant patients. The aim of this study was to characterize the effect of treatment on blood clots in vitro using quantitative ultrasound parameters. METHODS: Blood from 10 pigs was collected to form three clots per pig in gelatin phantoms. Clots were subjected to 1) no treatment, 2) rt-PA (recombinant tissue plasminogen activator) treatment after 20 minutes of clotting, and 3) rt-PA treatment after 60 minutes of clotting. Clots were weighted before and after the experiment to assess the treatment effect by the mass loss. The clot kinetics was studied over 100 minutes using elastography (Young's modulus, shear wave dispersion, and shear wave attenuation). Homodyne K-distribution (HKD) parameters derived from speckle statistics were also studied during clot formation and dissolving (diffuse-to-total signal power ratio and intensity parameters). RESULTS: Treated clots loosed significantly more mass than non-treated ones (P < .005). A significant increase in Young's modulus was observed over time (P < .001), and significant reductions were seen for treated clots at 20 or 60 minutes compared with untreated ones (P < .001). The shear wave dispersion differed for treated clots at 60 minutes versus no treatments (P < .001). The shear wave attenuation decreased over time (P < .001), and was different for clots treated at 20 minutes versus no treatments (P < .031). The HKD intensity parameter varied over time (P < .032), and was lower for clots treated at 20 and 60 minutes than those untreated (P < .001 and P < .02). CONCLUSION: The effect of rt-PA treatment could be confirmed by a decrease in Young's modulus and HKD intensity parameter. The shear wave dispersion and shear wave attenuation were sensitive to late and early treatments, respectively. The Young's modulus, shear wave attenuation, and HKD intensity parameter varied over time despite treatment.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Trombosis , Humanos , Animales , Porcinos , Activador de Tejido Plasminógeno/uso terapéutico , Activador de Tejido Plasminógeno/farmacología , Trombosis/diagnóstico por imagen , Trombosis/tratamiento farmacológico , Ultrasonografía , Coagulación Sanguínea , Módulo de Elasticidad
2.
J Ultrasound Med ; 43(3): 535-551, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38108551

RESUMEN

OBJECTIVE: Improve the characterization of mechanical properties of blood clots. Parameters derived from shear wave (SW) velocity and SW amplitude spectra were determined for gel phantoms and in vitro blood clots. METHODS: Homogeneous phantoms and phantoms with gel or blood clot inclusions of different diameters and mechanical properties were analyzed. SW amplitude spectra were used to observe resonant peaks. Parameters derived from those resonant peaks were related to mimicked blood clot properties. Three regions of interest were tested to analyze where resonances occurred the most. For blood experiments, 20 samples from different pigs were analyzed over time during a 110-minute coagulation period using the Young modulus, SW frequency dispersion, and SW attenuation. RESULTS: The mechanical resonance was manifested by an increase in the number of SW spectral peaks as the inclusion diameter was reduced (P < .001). In blood clot inclusions, the Young modulus increased over time during coagulation (P < .001). Descriptive spectral parameters (frequency peak, bandwidth, and distance between resonant peaks) were linearly correlated with clot elasticity values (P < .001) with R2 = .77 for the frequency peak, .60 for the bandwidth, and .48 for the distance between peaks. The SW dispersion and SW attenuation reflecting the viscous behavior of blood clots decreased over time (P < .001), mainly in the early stage of coagulation (first minutes). CONCLUSION: The confined soft inclusion configuration favored SW mechanical resonances potentially challenging the computation of spectral-based parameters, such as the SW attenuation. The impact of resonances can be reduced by properly selecting the region of interest for data analysis.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Trombosis , Animales , Porcinos , Módulo de Elasticidad , Elasticidad , Viscosidad , Fantasmas de Imagen
3.
J Ultrasound Med ; 41(7): 1807-1816, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34713918

RESUMEN

OBJECTIVE: Investigate shear wave elastography (SWE) and quantitative ultrasound (QUS) parameters in patients hospitalized for lower limb deep vein thrombosis (DVT). METHOD: Sixteen patients with DVT were recruited and underwent SWE and radiofrequency data acquisitions for QUS on day 0, day 7, and day 30 after the beginning of symptoms, in both proximal and distal zones of the clot identified on B-mode scan. SWE and QUS features were computed to differentiate between thrombi at day 0, day 7, and day 30 following treatment with heparin or oral anticoagulant. The Young's modulus from SWE was computed, as well as QUS homodyned K-distribution (HKD) parameters reflecting blood clot structure. Median and interquartile range of SWE and QUS parameters within clot were taken as features. RESULTS: In the proximal zone of the clot, the HKD ratio of coherent-to-diffuse backscatter median showed a significant decrease from day 7 to day 30 (P = .036), while the HKD ratio of diffuse-to-total backscatter median presented a significant increase from day 7 to day 30 (P = .0491). In the distal zone of the clot, the HKD normalized intensity of the echo envelope median showed a significant increase from day 0 to day 30 (P = .0062). No SWE features showed statistically significant differences over time. Nonetheless, a trend of lower median of Young's modulus within clot for patients who developed a pulmonary embolism was observed. CONCLUSION: QUS features may be relevant to characterize clot's evolution over time. Further analysis of their clinical interpretation and validation on a larger dataset would deserve to be studied.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Trombosis de la Vena , Biomarcadores , Módulo de Elasticidad , Humanos , Ultrasonografía , Trombosis de la Vena/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA