Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Arch Orthop Trauma Surg ; 135(3): 417-25, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25663048

RESUMEN

INTRODUCTION: The incidence and natural course of pseudotumors in metal-on-metal total hip arthroplasties is largely unknown. The objective of this study was to identify the true incidence and risk factors of pseudotumor formation in large head metal-on-metal total hip arthroplasties. MATERIALS AND METHODS: Incidence, time course and risk factors for pseudotumor formation were analysed after large femoral head MoM-THA. We defined a pseudotumor as a (semi-)solid or cystic peri-prosthetic soft-tissue mass with a diameter ≥2 cm that could not be attributed to infection, malignancy, bursa or scar tissue. All patients treated in our clinic with MoM-THA's were contacted. CT scan, metal ions and X-rays were obtained. Symptoms were recorded. RESULTS: After median follow-up of 3 years, 706 hips were screened in 626 patients. There were 228 pseudotumors (32.3 %) in 219 patients (35.0 %). Pseudotumor formation significantly increased after prolonged follow-up. Seventy-six hips (10.8 %) were revised in 73 patients (11.7 %), independent risk factors were identified. Best cutoff point for cobalt and chromium was 4 µg/l (68 and 77 nmol/l). CONCLUSIONS: This study confirms a high incidence of pseudotumors, dramatically increasing after prolonged follow-up. Risk factors for pseudotumors are of limited importance. Pain was the strongest predictor for pseudotumor presence; cobalt chromium and swelling were considered poor predictors. Cross-sectional imaging is the main screening tool during follow-up.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Granuloma de Células Plasmáticas/epidemiología , Prótesis de Cadera/efectos adversos , Prótesis Articulares de Metal sobre Metal/efectos adversos , Adulto , Cromo/sangre , Cobalto/sangre , Femenino , Granuloma de Células Plasmáticas/sangre , Granuloma de Células Plasmáticas/etiología , Articulación de la Cadera/patología , Articulación de la Cadera/cirugía , Humanos , Incidencia , Iones/sangre , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/sangre , Osteoartritis de la Cadera/cirugía , Diseño de Prótesis , Falla de Prótesis , Reoperación , Factores de Riesgo , Factores de Tiempo
2.
J Bone Joint Surg Am ; 96(18): e157, 2014 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-25232087

RESUMEN

BACKGROUND: Revision of hip implants due to adverse tissue reactions to metal debris has been associated with wear and corrosion of the metal-on-metal bearing articulation and the modular taper interface. Bearing articulation wear is increased in conditions of poor lubrication, which can also lead to high friction moments that may cause corrosion at the taper interface. This suggests that wear of the bearing and increased corrosion of the taper interface should occur simultaneously, which was investigated in this study. METHODS: Forty-three large-diameter cobalt-chromium bearings of the same design, implanted with a titanium stem using a titanium adapter, were retrieved at revision at a single center. Retrievals were grouped according to visual inspection of the female taper surface of the adapter into slight and severe corrosion groups. Volume change of bearing and taper surfaces was assessed using a coordinate measurement machine. Serum ion concentrations were determined for forty-three patients, whereas tissue metal concentration was measured for twelve patients. RESULTS: Severe taper corrosion was observed in 30% of the retrievals. Corrosion was observed either as material deposition or wear. The overall bearing wear rate was significantly higher in the group with severe taper corrosion than in the group with slight corrosion (7.2 ± 9.0 mm(3)/yr versus 3.1 ± 6.8 mm(3)/yr, respectively; p = 0.023) as were the serum cobalt (40.5 ± 44.9 µg/L versus 15.2 ± 23.9 µg/L, respectively; p = 0.024) and chromium ion concentrations (32.7 ± 32.7 µg/L versus 12.0 ± 15.1 µg/L, respectively; p = 0.019). Serum metal ion concentrations were more consistent indicators of wear than tissue metal concentrations. CONCLUSIONS: The increased bearing articulation wear and serum metal ion concentrations in cases with taper interface corrosion support the hypothesis that increased friction in the joint articulation is one of the factors responsible for simultaneous articulation and taper damage. However, independent taper or bearing damage was also observed, suggesting that other factors are involved in the process.


Asunto(s)
Prótesis de Cadera , Prótesis Articulares de Metal sobre Metal , Falla de Prótesis , Artroplastia de Reemplazo de Cadera/instrumentación , Cromo/química , Cromo/uso terapéutico , Cobalto/química , Cobalto/uso terapéutico , Corrosión , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Sistema de Registros , Titanio/química , Titanio/uso terapéutico
3.
J Bone Joint Surg Br ; 94(6): 755-61, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22628588

RESUMEN

Peri-articular soft-tissue masses or 'pseudotumours' can occur after large-diameter metal-on-metal (MoM) resurfacing of the hip and conventional total hip replacement (THR). Our aim was to assess the incidence of pseudotumour formation and to identify risk factors for their formation in a prospective cohort study. A total of 119 patients who underwent 120 MoM THRs with large-diameter femoral heads between January 2005 and November 2007 were included in the study. Outcome scores, serum metal ion levels, radiographs and CT scans were obtained. Patients with symptoms or an identified pseudotumour were offered MRI and an ultrasound-guided biopsy. There were 108 patients (109 hips) eligible for evaluation by CT scan at a mean follow-up of 3.6 years (2.5 to 4.5); 42 patients (39%) were diagnosed with a pseudotumour. The hips of 13 patients (12%) were revised to a polyethylene acetabular component with small-diameter metal head. Patients with elevated serum metal ion levels had a four times increased risk of developing a pseudotumour. This study shows a substantially higher incidence of pseudotumour formation and subsequent revisions in patients with MoM THRs than previously reported. Because most revision cases were identified only after an intensive screening protocol, we recommend close monitoring of patients with MoM THR.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Enfermedades del Tejido Conjuntivo/etiología , Granuloma de Células Plasmáticas/etiología , Prótesis de Cadera/efectos adversos , Adulto , Anciano , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Enfermedades del Tejido Conjuntivo/diagnóstico , Enfermedades del Tejido Conjuntivo/cirugía , Método Doble Ciego , Femenino , Granuloma de Células Plasmáticas/diagnóstico , Granuloma de Células Plasmáticas/cirugía , Humanos , Imagen por Resonancia Magnética , Masculino , Metales/sangre , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis/etiología , Reoperación/métodos , Tomografía Computarizada por Rayos X
4.
Int Orthop ; 33(1): 49-52, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17952437

RESUMEN

Between 1988 and 2002, 47 patients (50 hips) were treated with acetabular shell augmentation arthroplasty for recurrent idiopathic dislocation of their total hip arthroplasty. Apparent causes for dislocation such as deep infection, component malposition, or polyethylene wear were excluded. Follow-up averaged 74 months (range, 12-178 months), and clinically, 30 hips (60%) did not present a subsequent dislocation at most recent follow-up. In five hips (10%), deep infection after the augmentation procedure necessitated removal of the entire prosthesis. In our opinion, this technique cannot be recommended as it has an unacceptable failure and high infection rate.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Luxación de la Cadera/prevención & control , Prótesis de Cadera/estadística & datos numéricos , Inestabilidad de la Articulación/prevención & control , Anciano , Anciano de 80 o más Años , Desviación Ósea/complicaciones , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Polietileno/efectos adversos , Falla de Prótesis , Infecciones Relacionadas con Prótesis/complicaciones , Prevención Secundaria
5.
Arch Orthop Trauma Surg ; 127(5): 375-9, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17297597

RESUMEN

Several studies have demonstrated a correlation between the acetabular cup position and the risk of dislocation, wear and range of motion after total hip arthroplasty. The present study was designed to evaluate the accuracy of the surgeon's estimated position of the cup after freehand placement in total hip replacement. Peroperative estimated abduction and anteversion of 200 acetabular components (placed by three orthopaedic surgeons and nine residents) were compared with measured outcomes (according to Pradhan) on postoperative radiographs. Cups were placed in 49.7 degrees (SD 6.7) of abduction and 16.0 degrees (SD 8.1) of anteversion. Estimation of placement was 46.3 degrees (SD 4.3) of abduction and 14.6 degrees (SD 5.9) of anteversion. Of more interest is the fact that for the orthopaedic surgeons the mean inaccuracy of estimation was 4.1 degrees (SD 3.9) for abduction and 5.2 degrees (SD 4.5) for anteversion and for their residents this was respectively, 6.3 degrees (SD 4.6) and 5.7 degrees (SD 5.0). Significant differences were found between orthopaedic surgeons and residents for inaccuracy of estimation for abduction, not for anteversion. Body mass index, sex, (un)cemented fixation and surgical approach (anterolateral or posterolateral) were not significant factors. Based upon the inaccuracy of estimation, the group's chance on future cup placement within Lewinnek's safe zone (5-25 degrees anteversion and 30-50 degrees abduction) is 82.7 and 85.2% for anteversion and abduction separately. When both parameters are combined, the chance of accurate placement is only 70.5%. The chance of placement of the acetabular component within 5 degrees of an intended position, for both abduction and anteversion is 21.5% this percentage decreases to just 2.9% when the tolerated error is 1 degrees . There is a tendency to underestimate both abduction and anteversion. Orthopaedic surgeons are superior to their residents in estimating abduction of the acetabular component. The results of this study indicate that freehand placement of the acetabular component is not a reliable method.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Ajuste de Prótesis/métodos , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Competencia Clínica , Femenino , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Radiografía
6.
Br J Surg ; 94(2): 244-7, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17078115

RESUMEN

BACKGROUND: Publications in peer-reviewed journals are the main determinants of research rating and funding. The present study assesses worldwide scientific contributions in the field of surgical research. METHODS: Fifteen major surgical journals were selected for a bibliometric search in Medline/PubMed over a 6-year period (2000-2005). All articles with abstracts were totalled according to country of corresponding author. Publications (total and corrected for population size) and journal impact factor were assessed according to country. RESULTS: A total of 18,717 articles were identified. Fifteen countries generated 88.8 per cent of these: the USA produced 42.1 per cent, Japan 9.1 per cent and the UK 7.6 per cent. When corrected for population size, the Netherlands, Sweden and Switzerland topped the ranking; the USA was sixth. Ireland and Switzerland scored the highest mean impact factor. CONCLUSION: The USA is the most productive country in terms of absolute number of surgical publications in the selected journals. However, when population size is taken into consideration, certain smaller European countries were more prolific.


Asunto(s)
Cirugía General/estadística & datos numéricos , Publicaciones Periódicas como Asunto/estadística & datos numéricos , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA