Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur Phys J C Part Fields ; 83(6): 467, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37303462

RESUMEN

The ICARUS collaboration employed the 760-ton T600 detector in a successful 3-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous νe appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around 1 eV2. After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid argon filling and recirculation. ICARUS then started its operations collecting the first neutrino events from the booster neutrino beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022. The first goal of the ICARUS data taking will be a study to either confirm or refute the claim by Neutrino-4 short-baseline reactor experiment. ICARUS will also perform measurement of neutrino cross sections with the NuMI beam and several Beyond Standard Model searches. After the first year of operations, ICARUS will search for evidence of sterile neutrinos jointly with the Short-Baseline Near Detector, within the Short-Baseline Neutrino program. In this paper, the main activities carried out during the overhauling and installation phases are highlighted. Preliminary technical results from the ICARUS commissioning data with the BNB and NuMI beams are presented both in terms of performance of all ICARUS subsystems and of capability to select and reconstruct neutrino events.

2.
Phys Rev Lett ; 130(10): 101001, 2023 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-36962014

RESUMEN

Dark matter elastic scattering off nuclei can result in the excitation and ionization of the recoiling atom through the so-called Migdal effect. The energy deposition from the ionization electron adds to the energy deposited by the recoiling nuclear system and allows for the detection of interactions of sub-GeV/c^{2} mass dark matter. We present new constraints for sub-GeV/c^{2} dark matter using the dual-phase liquid argon time projection chamber of the DarkSide-50 experiment with an exposure of (12 306±184) kg d. The analysis is based on the ionization signal alone and significantly enhances the sensitivity of DarkSide-50, enabling sensitivity to dark matter with masses down to 40 MeV/c^{2}. Furthermore, it sets the most stringent upper limit on the spin independent dark matter nucleon cross section for masses below 3.6 GeV/c^{2}.

3.
Phys Rev Lett ; 130(10): 101002, 2023 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-36962032

RESUMEN

We present a search for dark matter particles with sub-GeV/c^{2} masses whose interactions have final state electrons using the DarkSide-50 experiment's (12 306±184) kg d low-radioactivity liquid argon exposure. By analyzing the ionization signals, we exclude new parameter space for the dark matter-electron cross section σ[over ¯]_{e}, the axioelectric coupling constant g_{Ae}, and the dark photon kinetic mixing parameter κ. We also set the first dark matter direct-detection constraints on the mixing angle |U_{e4}|^{2} for keV/c^{2} sterile neutrinos.

4.
Phys Rev Lett ; 121(11): 111303, 2018 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-30265123

RESUMEN

We present new constraints on sub-GeV dark-matter particles scattering off electrons based on 6780.0 kg d of data collected with the DarkSide-50 dual-phase argon time projection chamber. This analysis uses electroluminescence signals due to ionized electrons extracted from the liquid argon target. The detector has a very high trigger probability for these signals, allowing for an analysis threshold of three extracted electrons, or approximately 0.05 keVee. We calculate the expected recoil spectra for dark matter-electron scattering in argon and, under the assumption of momentum-independent scattering, improve upon existing limits from XENON10 for dark-matter particles with masses between 30 and 100 MeV/c^{2}.

5.
Phys Rev Lett ; 121(8): 081307, 2018 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-30192596

RESUMEN

We present the results of a search for dark matter weakly interacting massive particles (WIMPs) in the mass range below 20 GeV/c^{2} using a target of low-radioactivity argon with a 6786.0 kg d exposure. The data were obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso. The analysis is based on the ionization signal, for which the DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The observed rate in the detector at 0.5 keVee is about 1.5 event/keVee/kg/d and is almost entirely accounted for by known background sources. We obtain a 90% C.L. exclusion limit above 1.8 GeV/c^{2} for the spin-independent cross section of dark matter WIMPs on nucleons, extending the exclusion region for dark matter below previous limits in the range 1.8-6 GeV/c^{2}.

6.
Clin Cancer Res ; 5(4): 899-908, 1999 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-10213227

RESUMEN

A mouse-human chimeric monoclonal antibody (chNR-LU-13), specific for the EGP40 pancarcinoma antigen, was humanized through three-dimensional molecular modeling. Humanization of the chNR-LU-13 antibody is expected to enhance its use for patients undergoing immunotherapy. On the basis of the observed amino acid sequence identity, chNR-LU-13 complementary determining regions (CDRs) of the V(L) and V(H) regions were grafted onto the human anti-DNA-associated idiotype immunoglobulin clone, R3.5H5G'CL. Ten amino acids residues within the humanized framework were back-mutated to their corresponding chNR-LU-13 sequence, because they were predicted to disrupt the canonical classification of the CDRs or were within 5 A of a CDR. Synthesis of the V(L) and V(H) regions was accomplished by recursive PCR, and the dual-chain expression vector p451.C4 was positioned under control of the CMV(P+E). We observed by competitive ELISA that the recombinant humanized NR-LU-13 (huNR-LU-13) IgG1 antibody exhibited an indistinguishable immunoreactivity profile when compared with the murine monoclonal antibody (muNR-LU-10). The huNR-LU-13 antibody was effective in mediating both antibody-dependent cellular cytotoxicity and complement-mediated cytotoxicity when assayed against either the breast carcinoma cell line, MCF-7, or the colon adenocarcinoma cell line, SW1222. Biodistribution studies using i.v. coinjected 131I-muNR-LU-10 and 125I-huNR-LU-13 confirmed that the huNR-LU-13 specifically targets to the tumor in athymic BALB/c mice bearing the SW1222 human tumor xenograft. Humanization of the chNR-LU-13 antibody is expected to eliminate an undesired human antimouse antibody response, allowing for repeated i.v. administration into humans.


Asunto(s)
Anticuerpos Monoclonales/química , Anticuerpos Monoclonales/uso terapéutico , Neoplasias Experimentales/tratamiento farmacológico , Secuencia de Aminoácidos , Animales , Anticuerpos Monoclonales/genética , Anticuerpos Monoclonales/farmacocinética , Antígenos de Neoplasias/inmunología , Células CHO , Moléculas de Adhesión Celular/inmunología , Cricetinae , Diseño de Fármacos , Evaluación Preclínica de Medicamentos , Ensayo de Inmunoadsorción Enzimática , Molécula de Adhesión Celular Epitelial , Humanos , Cadenas Pesadas de Inmunoglobulina/genética , Cadenas Pesadas de Inmunoglobulina/inmunología , Cadenas Ligeras de Inmunoglobulina/genética , Cadenas Ligeras de Inmunoglobulina/inmunología , Región Variable de Inmunoglobulina/genética , Región Variable de Inmunoglobulina/inmunología , Ratones , Ratones Endogámicos BALB C , Ratones Desnudos , Datos de Secuencia Molecular , Reacción en Cadena de la Polimerasa , Proteínas Recombinantes de Fusión/química , Proteínas Recombinantes de Fusión/genética , Proteínas Recombinantes de Fusión/inmunología , Células Tumorales Cultivadas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...