1.
Eur Radiol ; 33(12): 8999-9009, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37402003

RESUMEN

OBJECTIVE: To validate the proton density fat fraction (PDFF) obtained by the MRQuantif software from 2D chemical shift encoded MR (CSE-MR) data in comparison with the histological steatosis data. METHODS: This study, pooling data from 3 prospective studies spread over time between January 2007 and July 2020, analyzed 445 patients who underwent 2D CSE-MR and liver biopsy. MR derived liver iron concentration (MR-LIC) and PDFF was calculated using the MRQuantif software. The histological standard steatosis score (SS) served as reference. In order to get a value more comparable to PDFF, histomorphometry fat fraction (HFF) were centrally determined for 281 patients. Spearman correlation and the Bland and Altman method were used for comparison. RESULTS: Strong correlations were found between PDFF and SS (rs = 0.84, p < 0.001) or HFF (rs = 0.87, p < 0.001). Spearman's coefficients increased to 0.88 (n = 324) and 0.94 (n = 202) when selecting only the patients without liver iron overload. The Bland and Altman analysis between PDFF and HFF found a mean bias of 5.4% ± 5.7 [95% CI 4.7, 6.1]. The mean bias was 4.7% ± 3.7 [95% CI 4.2, 5.3] and 7.1% ± 8.8 [95% CI 5.2, 9.0] for the patients without and with liver iron overload, respectively. CONCLUSION: The PDFF obtained by MRQuantif from a 2D CSE-MR sequence is highly correlated with the steatosis score and very close to the fat fraction estimated by histomorphometry. Liver iron overload reduced the performance of steatosis quantification and joint quantification is recommended. This device-independent method can be particularly useful for multicenter studies. CLINICAL RELEVANCE STATEMENT: The quantification of liver steatosis using a vendor-neutral 2D chemical-shift MR sequence, processed by MRQuantif, is well correlated to steatosis score and histomorphometric fat fraction obtained from biopsy, whatever the magnetic field and the MR device used. KEY POINTS: • The PDFF measured by MRQuantif from 2D CSE-MR sequence data is highly correlated to hepatic steatosis. • Steatosis quantification performance is reduced in case of significant hepatic iron overload. • This vendor-neutral method may allow consistent estimation of PDFF in multicenter studies.


Asunto(s)
Hígado Graso , Sobrecarga de Hierro , Enfermedad del Hígado Graso no Alcohólico , Humanos , Protones , Estudios Prospectivos , Hígado/diagnóstico por imagen , Hígado/patología , Imagen por Resonancia Magnética/métodos , Hígado Graso/diagnóstico por imagen , Hígado Graso/patología , Sobrecarga de Hierro/diagnóstico por imagen , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Enfermedad del Hígado Graso no Alcohólico/patología
2.
Abdom Radiol (NY) ; 42(6): 1713-1720, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28224171

RESUMEN

PURPOSE: To evaluate the performance and limitations of the signal intensity ratio method for quantifying liver iron overload at 3 T. METHODS: Institutional review board approval and written informed consent from all participants were obtained. One hundred and five patients were included prospectively. All patients underwent a liver biopsy with biochemical assessment of hepatic iron concentration and a 3 T MRI scan with 5 breath-hold single-echo gradient-echo sequences. Linear correlation between liver-to-muscle signal intensity ratio and liver iron concentration was calculated. The algorithm for calculating magnetic resonance hepatic iron concentration was adapted from the method described by Gandon et al. with echo times divided by 2. Sensitivity and specificity were calculated. RESULTS: Five patients were excluded (coil selection failure or missing sequence) and 100 patients were analyzed, 64 men and 36 women, 52 ± 13.3 years old, with a biochemical hepatic iron concentration range of 0-630 µmol/g. Linear correlation between biochemical hepatic iron concentration and MR-hepatic iron concentration was excellent with a correlation coefficient = 0.96, p < 0.0001. Sensitivity and specificity were, respectively, 83% (0.70-0.92) and 96% (0.85-0.99), with a pathological threshold of 36 µmol/g. CONCLUSION: Signal intensity ratio method for quantifying liver iron overload can be used at 3 T with echo times divided by 2.


Asunto(s)
Sobrecarga de Hierro/diagnóstico por imagen , Hepatopatías/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Algoritmos , Biopsia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad