Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Ultrasound Med ; 42(12): 2883-2895, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37688781

RESUMEN

OBJECTIVE: Chest CT is the reference test for assessing pulmonary injury in suspected or diagnosed COVID-19 with signs of clinical severity. This study aimed to evaluate the association of a lung ultrasonography score and unfavorable clinical evolution at 28 days. METHODS: The eChoVid is a multicentric study based on routinely collected data that was conducted in 8 emergency units in France; patients were included between March 19, 2020 and April 28, 2020 and underwent lung ultrasonography, a short clinical assessment by 2 emergency physicians blinded to each other's assessment, and chest CT. Lung ultrasonography consisted of scoring lesions from 0 to 3 in 8 chest zones, thus defining a global score (GS) of severity from 0 to 24. The primary outcome was the association of lung damage severity as assessed by the GS at day 0 and patient status at 28 days. Secondary outcomes were comparing the performance between GS and CT scan and the performance between a new trainee physician and an ultrasonography expert in scores. RESULTS: For the 328 patients analyzed, the GS showed good performance in predicting clinical worsening at 28 days (area under the receiver operating characteristic curve [AUC] 0.83, sensitivity 84.2%, specificity 76.4%). The GS showed good performance in predicting the CT severity assessment (AUC 0.84, sensitivity 77.2%, specificity 83.7%). CONCLUSION: A lung ultrasonography GS is a simple tool that can be used in the emergency department to predict unfavorable assessment at 28 days in patients with COVID-19.


Asunto(s)
COVID-19 , Humanos , COVID-19/diagnóstico por imagen , SARS-CoV-2 , Pulmón/diagnóstico por imagen , Ultrasonografía , Servicio de Urgencia en Hospital
2.
Leuk Lymphoma ; 62(6): 1379-1385, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33416408

RESUMEN

Point of care ultrasound (PoCUS) with pocket-size devices is an efficient and safe imaging modality that became a standard of care in various clinical settings. However, its implementation in hematology has never been evaluated so far. We conducted a prospective monocentric study aiming to harvest data on its usage and to assess its diagnostic and interventional performance in improving the accuracy of basic physical examination in hematological patients. After a focused training program, six hematologists were trained and conducted this study. Sixty-two patients were included. Only in 19 cases, further specialized imaging was required, whereas, in 43 patients PoCUS was sufficient to address the clinical inquiries. The use of PoCUS devices was assessed for its performance difficulty and usefulness perception with satisfactory outcomes. This study represents a proof-of-concept application of PoCUS in hematology, suggesting benefits over the physical examination.KEY POINTSPoCUS is particularly attractive in a hematological setting because able to improve the accuracy of physical examination.A hematology-focused training in PoCUS using handheld devices can allow hematologists to perform bed-side diagnostic and interventional US-based exams.


Asunto(s)
Hematología , Sistemas de Atención de Punto , Humanos , Estudios Prospectivos , Ultrasonografía
3.
Haematologica ; 106(9): 2374-2383, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32732366

RESUMEN

Significant morbidity and mortality have been associated with liver complications after allogeneic hematopoietic stem cell transplantation (allo-HSCT). Causes and consequences of these hepato-biliary complications are various and might be life-threatening. A high misdiagnosis rate has been reported because of a weak correlation between clinical, laboratory and imaging data. Liver elastography, a liver stiffness measure, is able to assess liver fibrosis and portal hypertension in most liver diseases, but data after allo-HSCT are scarce. Our aim was to determine the interest of sequential liver stiffness measurements for the diagnosis of early hepatic complications after allo-HSCT. Over a two years period of time, 161 consecutive adult patients were included and 146 were analyzed. Ultrasonography and elastography measurements were performed before transplantation, at day+7 and day+14 by three different experienced radiologists unaware of patients'clinical status. Eighty-one (55%) patients had liver involvements within the first 100 days after allo-HSCT. Baseline elastography was not predictive for the occurrence of overall liver abnormalities. A significant increase in 2D real-time shearwave elastography (2D-SWE) was found in patients with sinusoidal obstruction syndrome (SOS). Fifteen patients (10%) fulfilled EBMT score criteria and twelve (8%) reached Baltimore criteria for SOS diagnosis, but only six (4%) had a confirmed SOS. 2D-SWE at day+14 allowed early detection of SOS (AUROC=0.84, p=0.004) and improved sensibility (75%), specificity (99%) and positive predictive value (60%) over the Seattle, Baltimore or EBMT scores. A 2D-SWE measurement above 8.1kPa at day+14 after allo-HSCT seems a promising, non-invasive, and reproducible tool for early and accurate diagnosis of SOS.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Trasplante de Células Madre Hematopoyéticas , Enfermedad Veno-Oclusiva Hepática , Trasplante de Células Madre Hematopoyéticas/efectos adversos , Enfermedad Veno-Oclusiva Hepática/diagnóstico por imagen , Enfermedad Veno-Oclusiva Hepática/etiología , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/patología
4.
AEM Educ Train ; 2(1): 10-14, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30051059

RESUMEN

BACKGROUND: Ultrasound (US) has been a regular practice in emergency departments for several decades. Thus, train our students to US is of prime interest. Because US image acquisition ability can be very different from a patient to another (depending on image quality), it seems relevant to adapt US learning curves (LCs) to patient image quality using tools based on cumulative summation (CUSUM) as the risk-adjusted LC CUSUM (RLC). OBJECTIVES: The aim of this study was to monitor LC of medical students for the acquisition of abdominal emergency US views and to adapt these curves to patient image quality using RLC. METHODS: We asked medical students to perform abdominal US examinations with the acquisition of 11 views of interest on emergency patients after a learning session. Emergency physicians reviewed the student examinations for validation. LCs were plotted and the student was said proficient for a specific view if his LC reached a predetermined limit fixed by simulation. RESULTS: Seven students with no previous experience in US were enrolled. They performed 19 to 50 examinations of 11 views each. They achieve proficiency for a median of 9 (6-10) views. Aorta and right pleura views were validated by seven students; inferior vena cava, right kidney, and bladder by six; gallbladder and left kidney by five; portal veins and portal hilum by four; and subxyphoid and left pleura by three. The number of US examinations required to reach proficiency ranged from five to 41 depending on the student and on the type of view. LC showed that students reached proficiency with different learning speeds. CONCLUSIONS: This study suggests that, when monitoring LCs for abdominal emergency US, there is some heterogeneity in the learning process depending on the student skills and the type of view. Therefore, rules based on a predetermined number of examinations to reach proficiency are not satisfactory.

5.
Thyroid ; 21(9): 965-73, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21834683

RESUMEN

BACKGROUND: Thyroid surgery is common, but complications may occur. High-intensity focused ultrasound (HIFU) is a minimally invasive alternative to surgery. We hypothesized that an optimized HIFU device could be safe and effective for ablating benign thyroid nodules without affecting neighboring structures. METHODS: In this open, single-center feasibility study, 25 patients were treated with HIFU with real-time ultrasound imaging 2 weeks before a scheduled thyroidectomy for multinodular goiter. Thyroid ultrasonography imaging, thyroid function, were evaluated before and after treatment. Adverse events were carefully recorded. Each patient received HIFU for one thyroid nodule, solid or mixed, with mean diameter ≥8 mm, and no suspicion of malignancy. The HIFU device was progressively adjusted with stepwise testing. The energy level for ablation ranged from 35 to 94 J/pulse for different groups of patients. One pathologist examined all removed thyroids. RESULTS: Three patients discontinued treatment due to pain or skin microblister. Among the remaining 22 patients, 16 showed significant changes by ultrasound. Macroscopic and histological examinations showed that all lesions were confined to the targeted nodule without affecting neighboring structures. At pathological analysis, the extent of nodule destruction ranged from 2% to 80%. Five out of 22 patients had over 20% pathological lesions unmistakably attributed to HIFU. Seventeen cases had putative lesions including nonspecific necrosis, hemorrhage, nodule detachment, cavitations, and cysts. Among these 17 cases, 12 had both ultrasound changes and cavitation at histology that may be expected for an HIFU effect. In the last three patients ablated at the highest energy level, significant ultrasound changes and complete coagulative necrosis were observed in 80%, 78%, and 58% of the targeted area, respectively. There were no major complications of ablation. CONCLUSION: This study showed the potential efficacy of HIFU for human thyroid nodule ablation. Lesions were clearly visible by histology and ultrasound after high energy treatments, and safety and tolerability were good. We identified a power threshold for optimal necrosis of the target thyroid tissue. Further studies are ongoing to assess nodule changes at longer follow-up times.


Asunto(s)
Bocio Nodular/cirugía , Ultrasonido Enfocado de Alta Intensidad de Ablación , Nódulo Tiroideo/cirugía , Tiroidectomía , Adulto , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Estudios de Factibilidad , Femenino , Bocio Nodular/diagnóstico , Ultrasonido Enfocado de Alta Intensidad de Ablación/efectos adversos , Ultrasonido Enfocado de Alta Intensidad de Ablación/instrumentación , Humanos , Masculino , Persona de Mediana Edad , Necrosis , Paris , Pruebas de Función de la Tiroides , Nódulo Tiroideo/diagnóstico , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Doppler
6.
AJR Am J Roentgenol ; 193(2): W144-8, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19620417

RESUMEN

OBJECTIVE: We describe a coaxial introducer provided with an additional blunt-tip stylet that allows safe access to difficult-to-reach lymph nodes in the chest, abdomen, and pelvis under CT control. CONCLUSION: Once the thoracic, abdominal, or pelvic wall is crossed by the introducer fitted with the sharp-tip stylet, the blunt-tip stylet replaces the sharp stylet for further progression in the fat toward the target. The soft-tip stylet carries a smaller risk of inadvertent perforation displacing vital structures.


Asunto(s)
Biopsia/instrumentación , Ganglios Linfáticos/patología , Linfoma/patología , Neoplasias/patología , Abdomen , Adulto , Anciano , Anciano de 80 o más Años , Amiloidosis/patología , Biopsia/métodos , Diseño de Equipo , Femenino , Humanos , Ganglios Linfáticos/diagnóstico por imagen , Metástasis Linfática , Masculino , Persona de Mediana Edad , Pelvis/diagnóstico por imagen , Radiografía Abdominal , Radiografía Torácica , Fibrosis Retroperitoneal/patología , Espacio Retroperitoneal/diagnóstico por imagen , Estudios Retrospectivos , Sarcoidosis/patología , Tórax , Tomografía Computarizada por Rayos X/métodos , Tuberculosis/patología
7.
Prog Urol ; 13(4): 700-2, 2003 Sep.
Artículo en Francés | MEDLINE | ID: mdl-14650311

RESUMEN

The authors report a case of a 19-year-old man with alveolar rhabdomyosarcoma with an unusual clinical presentation. The diagnosis was established on lymph node biopsy performed on admission of the patient in a context simulating leukaemia. The patient achieved complete remission in response to high-dose chemotherapy. A recurrence in the form of an intratesticular metastasis demonstrated a periorbital tumour that was probably the primary tumour. The authors present the radiological and histological findings and a molecular biology study of the testicular metastasis, eliminating a primary testicular tumour.


Asunto(s)
Neoplasias Pulmonares/patología , Alveolos Pulmonares , Rabdomiosarcoma/secundario , Neoplasias Testiculares/secundario , Adulto , Humanos , Masculino , Rabdomiosarcoma/tratamiento farmacológico , Neoplasias Testiculares/tratamiento farmacológico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...