Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 34(8): 1648-1657, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37493505

RESUMEN

INTRODUCTION: Obesity is a well-known risk factor for atrial fibrillation (AF). We aim to evaluate the effect of baseline obesity on procedural complications, AF recurrence, and symptoms following catheter ablation (CA). METHODS: All consecutive patients undergoing AF ablation (2013-2021) at our center were enrolled in a prospective registry. The study included all consecutive patients with available data on body mass index (BMI). Primary endpoint was AF recurrence based on electrocardiographic documentation. Patients were categorized into five groups according to their baseline BMI. Patients survey at baseline and at follow-up were used to calculate AF symptom severity score (AFSS) as well as AF burden (mean of AF duration score and AF frequency score; scale 0: no AF to 10: continuous and 9 frequencies/durations in between). Patients were scheduled for follow-up visits with 12-lead electrocardiogram at 3, 6, and 12 months after ablation, and every 6 months thereafter. RESULTS: A total of 5841 patients were included (17% normal weight, 34% overweight, 27% Class I, 13% Class II, and 9% Class III obesity). Major procedural complications were low (1.5%) among all BMI subgroups. At 3 years AF recurrence was the highest in Class III obesity patients (48%) followed by Class II (43%), whereas Class I, normal, and overweight had similar results with lower recurrence (35%). In multivariable analyses, Class III obesity (BMI ≥ 40) was independently associated with increased risk for AF recurrence (hazard ratio, 1.30; confidence interval, 1.06-1.60; p = .01), whereas other groups had similar risk in comparison to normal weight. Baseline AFSS was lowest in normal weight, and highest in Obesity-III, median (interquartile range) 10 (5-16) versus 15 (10-21). In all groups, CA resulted in a significant improvement in their AFSS with a similar magnitude among the groups. At follow-up, AF burden was minimal and did not differ significantly between the groups. CONCLUSION: AF ablation is safe with a low complication rate across all BMI groups. Morbid obesity (BMI ≥ 40) was significantly associated with reduced AF ablation success. However, ablation resulted in improvement in QoL including reduction of the AFSS, and AF burden regardless of BMI.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Calidad de Vida , Sobrepeso/diagnóstico , Recurrencia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Obesidad/complicaciones , Obesidad/diagnóstico , Resultado del Tratamiento
2.
Circ Arrhythm Electrophysiol ; 16(6): e011565, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37183675

RESUMEN

BACKGROUND: Ablation is used for both rhythm control and improved quality of life (QoL) in atrial fibrillation (AF). It has been suggested that young adults may experience high recurrence rates after ablation and data remain lacking regarding QoL benefits. We aimed to investigate AF ablation outcomes and QoL benefits in young adults undergoing AF ablation using a large prospectively maintained registry and automated patient-reported outcomes (PRO). METHODS: All patients undergoing AF ablation (2013-2016) at our center were prospectively enrolled. Patients aged 50 years or younger were included. For PROs, QoL measures and symptoms were assessed at baseline, 3 months after ablation, and every 6 months thereafter. The AF severity score served as the main assessment of QoL. RESULTS: A total of 241 young adults (age, 16-50 years) were included (17% female, 40.3% persistent AF). In all, 77.2% of patients remained arrhythmia-free during the first year of follow-up (80% in nonstructural AF and 66% in structural AF). Using PROs, 90% of patients reported improvement in QoL throughout all survey time points up to 5 years postablation (P<0.0001). The baseline median AF severity score was 14 and improved to between 2 and 4 on all follow-up after ablation (P<0.0001). Patients also reported fewer and shorter AF episodes, fewer emergency room visits secondary to AF, and fewer hospitalizations (P<0.0001). CONCLUSIONS: Ablation remains an effective rhythm-control strategy in young adults with AF. Young adults also experience significant improvement in QoL with reduction of the frequency and duration of AF episodes and AF-related healthcare utilization.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Femenino , Adulto Joven , Adolescente , Adulto , Persona de Mediana Edad , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Calidad de Vida , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Recurrencia
3.
J Cardiovasc Electrophysiol ; 34(1): 54-61, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36259719

RESUMEN

INTRODUCTION: Catheter ablation for atrial fibrillation (AF) is frequently used for the purpose of rhythm control and improved quality of life (QoL). Although success rates are high, a significant proportion of patients require redo ablation. Data are scarce on patient-centered outcomes and QoL in patients undergoing redo AF ablation. We aimed to assess QoL and clinical outcomes using a large prospectively maintained patient-reported outcomes (PRO) registry. METHODS: All patients undergoing redo AF ablation (2013-2016) at our center were enrolled in a prospective registry for outcomes and assessed for QoL using automated PRO surveys (baseline, 3 and 6 months after ablation, every 6 months thereafter). Data were collected over 3 years of follow-up. The atrial fibrillation symptom severity scale (AFSSS) was used as the main measure for QoL. Additional variables included patient-reported improvement, AF burden, and AF-related healthcare utilization including emergency room (ER) visits and hospitalizations. RESULTS: A total of 848 patients were included (28% females, mean age 63.8, 51% persistent AF). By automated PRO, significant improvement in QoL was noted (baseline median AFSSS of 12 [5-18] and ranged between 2 and 4 on subsequent assessments; p < .0001), with ≥70%of patients reported remarkable improvement in their AF-related symptoms. The proportion of patients in AF at the time of baseline survey was 36%, and this decreased to <8% across all time points during follow-up (p < .0001). AF burden was significantly reduced (including frequency and duration of episodes; p < .0001), with an associated decrease in healthcare utilization after 6 months from the time of ablation (including ER visits and hospitalizations; p < .0001). The proportion of patients on anticoagulants or antiarrhythmics decreased on follow-up across all time points (p < .0001 for all variables). CONCLUSION: Most patients derive significant QoL benefit from redo AF ablation; with reduction of both AF burden and healthcare utilization.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Femenino , Humanos , Persona de Mediana Edad , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Calidad de Vida , Resultado del Tratamiento , Antiarrítmicos/uso terapéutico , Ablación por Catéter/efectos adversos , Medición de Resultados Informados por el Paciente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...