Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Cardiol ; 335: 85-92, 2021 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-33811960

RESUMEN

BACKGROUND: Concomitant mitral regurgitation (MR) impaired prognosis in patients undergoing transcatheter aortic valve implantation (TAVI). It has been suggested that the use of first generation self-expandable valve in patients with significant MR is associated with worse outcome as compared with balloon expandable valve. However, the impact of newer generation transcatheter devices on MR has not been investigated so far. We aim to assess the prognostic impact of MR in patients undergoing TAVI with the first-generation vs. the latest generation of self-expandable valves. METHODS: We analyzed 2964 consecutive patients who underwent TAVI. Patients were classified into 4 groups according to the degree of baseline MR and the generation of self expandable valve implanted. RESULTS: Of 1234 patients with moderate or severe MR, 817 were treated with first generation and 417 patients with second generation valves. Whereas, of 1730 patients with no or mild MR, 1130 were treated with first generation and 600 patients with second generation valves. Although, concomitant moderate-severe MR was found to be an independent predictor of mortality after TAVI, the use of newer generation self expandable valves was associated with higher survival rate at 1 year irrespective of the degree of preprocedural MR. At multivariable analysis the use of newer generation valve was associated with MR improvement throughout 1 year follow-up. CONCLUSION: Baseline moderate-severe MR is associated with an increase in mortality after TAVI. However, the degree of preprocedural MR doesn't impact survival when a second generation self expandable valve is used.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
Ann Ig ; 15(1): 23-34, 2003.
Artículo en Italiano | MEDLINE | ID: mdl-12666322

RESUMEN

The A.A. carried out a survey on hospital acquired infection (HAI) in the intensive care units (ICU) of five roman hospitals. The study monitored the following site-specific infection rates: pneumonia (PNE), blood stream infections (BSI), urinary tract infections (UTI), surgical site infections (SSI). According to CDC definitions all patients developing infection 48 hours or more after ward admission were included. Furthermore risk factors (i.e. age, sex, SAPS II), invasive procedures (i.e. endotracheal intubation, vascular and urinary catheterisation), microbiological isolates and their antibiotic susceptibility were screened. The overall 503 patients characteristics (i.e., age, length of stay, case-mix...) showed the wards as general ICU's. Although the SAPS II score was similar, mortality (18.2%-42.9%) and general infection rates (15.4%-40.4%) among the five ICU's were considerably variable (p < 0.05), as HAI episodes distribution by type: PNE (37-88%), BSI (6-42%), UTI (6-24%), SSI (3-7%) (p < 0.05). Also device-associated infection rates such as Ventilator-associated PNE (11.6-24.6@1000), Vascular catheter-associated BSI (3.4-19.2@1000). Urinary catheter-associated UTI (2.6-14.0@1000) and invasive procedures management were different. Among the infected patients the most commonly isolated microorganisms were P. aeruginosa and Staphylococcus spp., which presented a considerable antibiotic resistance. The study showed: 1) sampling (i.e. blood cultures, tracheal aspirate and urine samples) and laboratory methodology indispensable for a correct HAI diagnosis were not standardized in the five ICU's; 2) hospital infection control policy was not carried out in all ICU's. The study showed a lack of standardization which limits the comparability of the general roman ICU's.


Asunto(s)
Infección Hospitalaria/epidemiología , Unidades de Cuidados Intensivos , Adulto , Factores de Edad , Anciano , Infección Hospitalaria/etiología , Infección Hospitalaria/mortalidad , Infección Hospitalaria/prevención & control , Femenino , Encuestas de Atención de la Salud , Humanos , Control de Infecciones , Unidades de Cuidados Intensivos/normas , Tiempo de Internación , Masculino , Persona de Mediana Edad , Factores de Riesgo , Ciudad de Roma/epidemiología , Factores Sexuales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...