Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38795093

RESUMEN

BACKGROUND: Left atrial appendage occlusion (LAAO) provides mechanical cardioembolic protection for atrial fibrillation (AF) patients who cannot use oral anticoagulation therapy (OAT). Patients with a thrombotic event despite OAT are at high risk for recurrence and may also benefit from LAAO. OBJECTIVES: This study sought to investigate the efficacy of LAAO in AF patients with a thrombotic event on OAT compared to: 1) LAAO in AF patients with a contraindication for OAT; and 2) historical data. METHODS: The international LAAO after stroke despite oral anticoagulation (STR-OAC LAAO) collaboration included patients who underwent LAAO because of thrombotic events on OAT. This cohort underwent propensity score matching and was compared to the EWOLUTION (Evaluating Real-Life Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology) registry, which represents patients who underwent LAAO because of OAT contraindications. The primary outcome was ischemic stroke. Event rates were compared between cohorts and with historical data without OAT, yielding relative risk reductions based on risk scores. RESULTS: Analysis of 438 matched pairs revealed no significant difference in the ischemic stroke rate between the STR-OAC LAAO and EWOLUTION cohorts (2.5% vs 1.9%; HR: 1.37; 95% CI: 0.72-2.61). STR-OAC LAAO patients exhibited a higher thromboembolic risk (HR: 1.71; 95% CI: 1.04-2.83) but lower bleeding risk (HR: 0.39; 95% CI: 0.18-0.88) compared to EWOLUTION patients. The mortality rate was slightly higher in EWOLUTION (4.3% vs 6.9%; log-rank P = 0.028). Relative risk reductions for ischemic stroke were 70% and 78% in STR-OAC LAAO and EWOLUTION, respectively, compared to historical data without OAT. CONCLUSIONS: LAAO in patients with a thrombotic event on OAT demonstrated comparable stroke rates to the OAT contraindicated population in EWOLUTION. The thromboembolic event rate was higher and the bleeding rate lower, reflecting the intrinsically different risk profile of both populations. Until randomized trials are available, LAAO may be considered in patients with an ischemic event on OAT.

2.
EuroIntervention ; 20(8): e487-e495, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38629416

RESUMEN

BACKGROUND: Data on the likelihood of left ventricle (LV) recovery in patients with severe LV dysfunction and severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) and its prognostic value are limited. AIMS: We aimed to assess the likelihood of LV recovery following TAVI, examine its association with midterm mortality, and identify independent predictors of LV function. METHODS: In our multicentre registry of 17 TAVI centres in Western Europe and Israel, patients were stratified by baseline LV function (ejection fraction [EF] >/≤30%) and LV response: no LV recovery, LV recovery (EF increase ≥10%), and LV normalisation (EF ≥50% post-TAVI). RESULTS: Our analysis included 10,872 patients; baseline EF was ≤30% in 914 (8.4%) patients and >30% in 9,958 (91.6%) patients. The LV recovered in 544 (59.5%) patients, including 244 (26.7%) patients whose LV function normalised completely (EF >50%). Three-year mortality for patients without severe LV dysfunction at baseline was 29.4%. Compared to this, no LV recovery was associated with a significant increase in mortality (adjusted hazard ratio 1.32; p<0.001). Patients with similar LV function post-TAVI had similar rates of 3-year mortality, regardless of their baseline LV function. Three variables were associated with a higher likelihood of LV recovery following TAVI: no previous myocardial infarction (MI), estimated glomerular filtration rate >60 mL/min, and mean aortic valve gradient (mAVG) (expressed either as a continuous variable or as a binary variable using the standard low-flow, low-gradient aortic stenosis [AS] definition). CONCLUSIONS: LV recovery following TAVI and the extent of this recovery are major determinants of midterm mortality in patients with severe AS and severe LV dysfunction undergoing TAVI. Patients with no previous MI and those with an mAVG >40 mmHg show the best results following TAVI, which are at least equivalent to those for patients without severe LV dysfunction. (ClinicalTrials.gov: NCT04031274).


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Disfunción Ventricular Izquierda , Humanos , Válvula Aórtica/cirugía , Ventrículos Cardíacos , Volumen Sistólico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Función Ventricular Izquierda , Estudios Multicéntricos como Asunto , Estudios Clínicos como Asunto
3.
JACC Cardiovasc Interv ; 17(5): 681-692, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38479968

RESUMEN

BACKGROUND: The performance of latest iteration transcatheter aortic valve replacement platforms in patients with small aortic anatomy remains underexplored. OBJECTIVES: The aim of this study was to evaluate effectiveness and performance between the self-expanding (SE) Evolut PRO and PRO+ and the balloon-expandable (BE) SAPIEN ULTRA in patients with small aortic annuli. METHODS: Data from the OPERA-TAVI (Comparative Analysis of Evolut PRO vs. SAPIEN 3 ULTRA Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry were used, with 1:1 propensity score matching. Primary endpoints included 1-year effectiveness composite (all-cause mortality, disabling stroke, or heart failure hospitalization) and 30-day device-related (hemodynamic structural valve dysfunction and nonstructural valve dysfunction) outcomes. RESULTS: Among 3,516 patients, 251 matched pairs with aortic annular area <430 mm2 were assessed. The 1-year primary effectiveness outcome did not differ significantly between cohorts (SE 10.8% vs BE 11.2%; P = 0.91). The 30-day device-oriented composite outcome was more favorable in the Evolut PRO group (SE 4.8% vs BE 10.4%; P = 0.027). Notably, SE valve recipients showed higher rates of disabling stroke (SE 4.0% vs BE 0.0%; P < 0.01) and paravalvular leaks (mild or greater: SE 48.5% vs BE 18.6% [P < 0.001]; moderate: SE 4.5% vs BE 1.2% [P = 0.070]). The BE group had higher rates of prosthesis-patient mismatch (moderate or greater: SE 16.0% vs BE 47.1% [P < 0.001]; severe: SE 1.3% vs BE 5.7% [P = 0.197]) and more patients with residual mean gradients >20 mm Hg (SE 1.0% vs BE 13.5%; P < 0.001). CONCLUSIONS: In patients with small aortic annuli, transcatheter aortic valve replacement with latest iteration devices is safe. SE platforms are associated with more favorable device performance in terms of hemodynamic structural and nonstructural dysfunction. Randomized data are needed to validate these findings and guide informed device selection.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Resultado del Tratamiento , Sistema de Registros , Accidente Cerebrovascular/etiología
4.
Am J Cardiol ; 219: 60-70, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38401656

RESUMEN

Evidence regarding gender-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study aimed to evaluate the impact of gender on the treatment effect of Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices on clinical outcomes. The Comparative Analysis of Evolut PRO vs SAPIEN 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter, multinational registry including patients who underwent the latest-iteration PRO or ULTRA implantation. Overall, 1,174 of 1,897 patients were matched based on valve type and compared according to gender, whereas 470 men and 630 women were matched and compared according to valve type. The 30-day and 1-year outcomes were evaluated. In the PRO and ULTRA groups, men had a higher co-morbidity burden, whereas women had smaller aortic root. The 30-day (device success [DS], early safety outcome, permanent pacemaker implantation, patient-prosthesis mismatch, paravalvular regurgitation, bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke, and heart failure hospitalization) did not differ according to gender in both valve groups. However, the male gender decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction = 0.047). A higher risk of 30-day permanent pacemaker implantation and 1-year stroke and a lower risk of patient-prosthesis mismatch was observed in PRO versus ULTRA, regardless of gender. In conclusion, gender did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, except for 30-day DS, which was decreased in men (vs women) who received ULTRA (vs PRO).


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Factores Sexuales , Anciano de 80 o más Años , Anciano , Resultado del Tratamiento , Complicaciones Posoperatorias/epidemiología , Válvula Aórtica/cirugía
5.
EuroIntervention ; 20(1): 95-103, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37982161

RESUMEN

BACKGROUND: Midterm comparative analyses of the latest iterations of the most used Evolut and SAPIEN platforms for transcatheter aortic valve implantation (TAVI) are lacking. AIMS: We aimed to compare 1-year clinical outcomes of TAVI patients receiving Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices in current real-world practice. METHODS: Among patients enrolled in the OPERA-TAVI registry, patients with complete 1-year follow-up were considered for the purpose of this analysis. One-to-one propensity score matching was used to compare TAVI patients receiving PRO or ULTRA devices. The primary endpoint was a composite of 1-year all-cause death, disabling stroke and rehospitalisation for heart failure. Five prespecified subgroups of patients were considered according to leaflet and left ventricular outflow tract calcifications, annulus dimensions and angulation, and leaflet morphology. RESULTS: Among a total of 1,897 patients, 587 matched pairs of patients with similar clinical and anatomical characteristics were compared. The primary composite endpoint did not differ between patients receiving PRO or ULTRA devices (Kaplan-Meier [KM] estimates 14.0% vs 11.9%; log-rank p=0.27). Patients receiving PRO devices had higher rates of 1-year disabling stroke (KM estimates 2.6% vs 0.4%; log-rank p=0.001), predominantly occurring within 30 days after TAVI (1.4% vs 0.0%; p=0.004). Outcomes were consistent across all the prespecified subsets of anatomical scenarios (all pinteraction>0.10). CONCLUSIONS: One-year clinical outcomes of patients undergoing transfemoral TAVI and receiving PRO or ULTRA devices in the current clinical practice were similar, but PRO patients had higher rates of disabling stroke. Outcomes did not differ across the different anatomical subsets of the aortic root.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Sistema de Registros , Accidente Cerebrovascular/etiología , Diseño de Prótesis
6.
JACC Cardiovasc Interv ; 16(22): 2722-2732, 2023 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-38030358

RESUMEN

BACKGROUND: Scarce data exist on the evolution of device-related thrombus (DRT) after left atrial appendage closure (LAAC). OBJECTIVES: This study sought to assess the incidence, predictors, and clinical impact of persistent and recurrent DRT in LAAC recipients. METHODS: Data were obtained from an international multicenter registry including 237 patients diagnosed with DRT after LAAC. Of these, 214 patients with a subsequent imaging examination after the initial diagnosis of DRT were included. Unfavorable evolution of DRT was defined as either persisting or recurrent DRT. RESULTS: DRT resolved in 153 (71.5%) cases and persisted in 61 (28.5%) cases. Larger DRT size (OR per 1-mm increase: 1.08; 95% CI: 1.02-1.15; P = 0.009) and female (OR: 2.44; 95% CI: 1.12-5.26; P = 0.02) were independently associated with persistent DRT. After DRT resolution, 82 (53.6%) of 153 patients had repeated device imaging, with 14 (17.1%) cases diagnosed with recurrent DRT. Overall, 75 (35.0%) patients had unfavorable evolution of DRT, and the sole predictor was average thrombus size at initial diagnosis (OR per 1-mm increase: 1.09; 95% CI: 1.03-1.16; P = 0.003), with an optimal cutoff size of 7 mm (OR: 2.51; 95% CI: 1.39-4.52; P = 0.002). Unfavorable evolution of DRT was associated with a higher rate of thromboembolic events compared with resolved DRT (26.7% vs 15.1%; HR: 2.13; 95% CI: 1.15-3.94; P = 0.02). CONCLUSIONS: About one-third of DRT events had an unfavorable evolution (either persisting or recurring), with a larger initial thrombus size (particularly >7 mm) portending an increased risk. Unfavorable evolution of DRT was associated with a 2-fold higher risk of thromboembolic events compared with resolved DRT.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Tromboembolia , Trombosis , Humanos , Femenino , Incidencia , Apéndice Atrial/diagnóstico por imagen , Resultado del Tratamiento , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Fibrilación Atrial/complicaciones , Tromboembolia/diagnóstico por imagen , Tromboembolia/epidemiología , Tromboembolia/etiología , Trombosis/diagnóstico por imagen , Trombosis/epidemiología , Trombosis/etiología , Accidente Cerebrovascular/etiología
8.
J Cardiovasc Med (Hagerstown) ; 24(1): 12-19, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36440764

RESUMEN

Device-related thrombus (DRT) is a known complication occurring in up to 7% of patients undergoing percutaneous left atrial appendage closure (LAAC). Since the target population of LAAC is generally ineligible for oral anticoagulant therapies, DRT raises important concerns. The aim of this review will be to summarize available evidence on DRT after LAAC focusing on its possible impact on outcomes. Recent findings showed a tighter association between DRT and neurological ischemic events. Antithrombotic regimen adopted after LAAC may have a protective effect against DRT. Many patient-related and procedural factors have been identified as possible predictors of DRT. A tailored approach, which takes into account DRT, is needed in the patient selection for LAAC and in the postprocedural follow-up.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Trombosis , Humanos , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/epidemiología , Resultado del Tratamiento , Trombosis/etiología , Trombosis/complicaciones , Anticoagulantes/uso terapéutico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control
9.
Eur J Heart Fail ; 24(11): 2175-2184, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36482160

RESUMEN

AIM: To evaluate short-term changes in tricuspid regurgitation (TR) after transcatheter edge-to-edge mitral valve repair (M-TEER) in secondary mitral regurgitation (SMR), their predictors and impact on mortality. METHODS AND RESULTS: This is a retrospective analysis of SMR patients undergoing successful M-TEER (post-procedural mitral regurgitation ≤2+) at 13 European centres. Among 503 patients evaluated 79 (interquartile range [IQR] 40-152) days after M-TEER, 173 (35%) showed ≥1 degree of TR improvement, 97 (19%) had worsening of TR, and 233 (46%) remained unchanged. Smaller baseline left atrial diameter and residual mitral regurgitation 0/1+ were independent predictors of TR ≤2+ after M-TEER. There was a significant association between TR changes and New York Heart Association class and pulmonary artery systolic pressure decrease at echocardiographic re-assessment. At a median follow-up of 590 (IQR 209-1103) days from short-term echocardiographic re-assessment, all-cause mortality was lower in patients with improved compared to those with unchanged/worsened TR (29.6% vs. 42.3% at 3 years; log-rank p = 0.034). Baseline TR severity was not associated with mortality, whereas TR 0/1+ and 2+ at short-term follow-up was associated with lower all-cause mortality compared to TR 3/4+ (30.6% and 35.6% vs. 55.6% at 3 years; p < 0.001). A TR ≤2+ after M-TEER was independently associated with a 42% decreased risk of mortality (p = 0.011). CONCLUSION: More than one third of patients with SMR undergoing successful M-TEER experienced an improvement in TR. Pre-procedural TR was not associated with outcome, but a TR ≤2+ at short-term follow-up was independently associated with long-term mortality. Optimal M-TEER result and a small left atrium were associated with a higher likelihood of TR ≤2+ after M-TEER.


Asunto(s)
Insuficiencia Cardíaca , Válvula Mitral , Humanos , Estudios Retrospectivos
10.
J Am Heart Assoc ; 11(20): e023121, 2022 10 18.
Artículo en Inglés | MEDLINE | ID: mdl-36216434

RESUMEN

Background Malnutrition is associated with poor prognosis in several cardiovascular diseases. However, its prognostic impact in patients undergoing transcatheter edge-to-edge mitral valve repair (TEER) is not well known. This study sought to assess the prevalence, clinical associations, and prognostic consequences of malnutrition in patients undergoing TEER. Methods and Results A total of 892 patients undergoing TEER from the international MIVNUT (Mitral Valve Repair and Nutritional Status) registry were studied. Malnutrition status was assessed with the Controlling Nutritional Status score. The association of nutritional status with mortality was analyzed with multivariable Cox regression models, whereas the association with heart failure admission was assessed by Fine-Gray models, with death as a competing risk. According to the Controlling Nutritional Status score, 74.4% of patients with TEER had any degree of malnutrition at the time of TEER (75.1% in patients with body mass index <25 kg/m2, 72.1% in those with body mass index ≥25 kg/m2). However, only 20% had moderate-severe malnutrition. TEER was successful in most of patients (94.2%). During a median follow-up of 1.6 years (interquartile range, 0.6-3.0), 267 (29.9%) patients died and 256 patients (28.7%) were admitted for heart failure after TEER. Compared with normal nutritional status moderate-severe malnutrition resulted a strong predictor of mortality (adjusted hazard ratio [HR], 2.1 [95% CI, 1.1-2.4]; P<0.001) and heart failure admission (adjusted subdistribution HR, 1.6 [95% CI, 1.1-2.4]; P=0.015). Conclusions Malnutrition is common among patients submitted to TEER, and moderate-severe malnutrition is strongly associated with increased mortality and heart failure readmission. Assessment of nutritional status in these patients may help to improve risk stratification.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Desnutrición , Insuficiencia de la Válvula Mitral , Humanos , Estado Nutricional , Pronóstico , Válvula Mitral/cirugía , Factores de Riesgo , Desnutrición/diagnóstico , Desnutrición/epidemiología , Insuficiencia Cardíaca/etiología , Sistema de Registros , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
11.
JACC Cardiovasc Interv ; 15(23): 2398-2407, 2022 12 12.
Artículo en Inglés | MEDLINE | ID: mdl-36121242

RESUMEN

BACKGROUND: The latest iterations of devices for transcatheter aortic valve replacement (TAVR) have brought refinements to further improve patient outcomes. OBJECTIVES: This study sought to compare early outcomes of patients undergoing TAVR with the self-expanding (SE) Evolut PRO/PRO+ (Medtronic, Inc) or balloon-expandable (BE) Sapien 3 ULTRA (Edwards Lifesciences) devices. METHODS: The OPERA-TAVI (Comparative Analysis of Evolut PRO vs Sapien 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry collected data from 14 high-volume centers worldwide on patients undergoing TAVR with SE or BE devices. After excluding patients who were not eligible for both devices, patients were compared using 1:1 propensity score matching. The primary efficacy and safety outcomes were Valve Academic Research Consortium-3 device success and early safety, respectively. RESULTS: Among 2,241 patients eligible for the present analysis, 683 pairs of patients were matched. The primary efficacy outcome did not differ between patients receiving SE or BE transcatheter aortic valves (SE: 87.4% vs BE: 85.9%; P = 0.47), but the BE device recipients showed a higher rate of the primary safety outcome (SE: 69.1% vs BE: 82.6%; P < 0.01). This finding was driven by the higher rates of permanent pacemaker implantation (SE: 17.9% vs BE: 10.1%; P < 0.01) and disabling stroke (SE: 2.3% vs BE: 0.7%; P = 0.03) in SE device recipients. On post-TAVR echocardiography, the rate of moderate to severe paravalvular regurgitation was similar between groups (SE: 3.2% vs BE: 2.3%; P = 0.41), whereas lower mean transvalvular gradients were observed in the SE cohort (median SE: 7.0 vs BE: 12.0 mm Hg; P < 0.01). CONCLUSIONS: The OPERA-TAVI registry showed that SE and BE devices had comparable Valve Academic Research Consortium-3 device success rates, but the BE device had a higher rate of early safety. The higher permanent pacemaker implantation and disabling stroke rates in SE device recipients drove this composite endpoint.


Asunto(s)
Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
12.
G Ital Cardiol (Rome) ; 23(7 Suppl 2): 13S-21S, 2022 07.
Artículo en Italiano | MEDLINE | ID: mdl-35848913

RESUMEN

Acute pulmonary embolism (PE) is a common disease associated with high mortality rates that vary widely according to patient clinical presentation and hemodynamic status. According to international guidelines, systemic thrombolysis (ST) is the mainstem treatment in patients with high risk PE and intermediate-high risk PE evolving towards hemodynamic decompensation, showing lower mortality compared with anticoagulant therapy alone despite a high rate of bleeding events. Considering that a large proportion of patients presents contraindication to ST, catheter-directed therapies (CDTs) could tackle some unsolved issues, targeting the treatment to the pulmonary arteries, avoiding the dreaded complications of ST.The aim of this review is to describe the current indication for CDTs in terms of patient selection and timing of treatment, to describe contemporary available medical devices and techniques, discussing current knowledge of safety and efficacy and the importance of multidisciplinary team in PE management.


Asunto(s)
Embolia Pulmonar , Terapia Trombolítica , Enfermedad Aguda , Fibrinolíticos , Humanos , Embolia Pulmonar/tratamiento farmacológico , Factores de Riesgo , Terapia Trombolítica/métodos , Resultado del Tratamiento
13.
J Cardiovasc Med (Hagerstown) ; 23(7): 454-462, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35763766

RESUMEN

AIMS: The aim of this study was to minimize the procedure, and reduce the length of hospital stay (LoS) is the future objective for transcatheter aortic valve replacement (TAVI).Aims of the study are to identify procedural and electrocardiographical predictors of fast-track discharge in patients who underwent TAVI. METHODS: Patients treated with TAVI included in the One Hospital ClinicalService project were categorized according to the LoS. 'Fast-Track' population, with a postprocedural LoS less than or equal to 3 days, was compared with the 'Slow-Track' population with a postprocedural LoS greater than 3 days. RESULTS: One thousand five hundred and one patients were collected. Despite single baseline characteristics being almost similar between the two groups, Slow-Track group showed a higher surgical risk (P < 0.001). Patients in the Slow-Track group were more frequently treated with general anaesthesia (P = 0.002) and less frequently predilated (P < 0.001) and received a lower amount of contrast media. No difference between Slow-Track and Fast-Track patients was observed at 30 days in death and in cardiovascular rehospitalization.In the multivariable analysis, STS score of at least 4% [odds ratio (OR): 1.64; P = 0.01], general anaesthesia (OR: 2.80; P = 0.03), predilation (OR: 0.45; P < 001), NYHA 3-4 at baseline (OR: 1.65; P = 0.01), AVB I/LBBB/RBBB onset (OR: 2.41; P < 0.001) and in-hospital new PM (OR: 2.63; P < 0.001) were independently associated with a higher probability of Slow-Track. CONCLUSION: Fast-Track patients were safely discharged home showing no difference in clinical outcomes after discharge up to 30 days compared with the Slow-Track group. The STS score, general anaesthesia, NYHA 3--4 at baseline, in-hospital onset of conduction disturbances and new PM implantation after TAVI turned out to be predictors of Slow-Track.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Electrocardiografía , Fluoroscopía , Humanos , Alta del Paciente , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos
14.
JACC Cardiovasc Interv ; 15(12): 1266-1274, 2022 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-35738747

RESUMEN

BACKGROUND: Data on outcomes of transcatheter aortic valve replacement (TAVR) using balloon-expandable valves (BEVs) or self-expandable valves (SEVs) as well as the impact of center valve preference on these outcomes are limited. OBJECTIVES: The aim of this study was to compare outcomes of TAVR procedures using third-generation BEVs and SEVs stratified by center valve preference. METHODS: In a multicenter registry (n = 17), 13 centers exhibited valve preference (66.6%-90% of volume) and were included. Outcomes were compared between BEVs and SEVs stratified by center valve preference. RESULTS: In total, 7,528 TAVR procedures (3,854 with SEVs and 3,674 with BEVs) were included. The mean age was 81 years, and the mean Society of Thoracic Surgeons score was 5.2. Baseline characteristics were similar between BEVs and SEVs. Need for pacemaker implantation was higher with SEVs at BEV- and SEV-dominant centers (17.8% vs 9.3% [P < 0.001] and 12.7% vs 10.0% [P = 0.036], respectively; HR: 1.51; P for interaction = 0.021), risk for cerebrovascular accident was higher with SEVs at BEV-dominant but not SEV-dominant centers (3.6% vs 1.1% [P < 0.001] and 2.2% vs 1.4% [P = 0.162]; HR: 2.08; P for interaction < 0.01). Aortic regurgitation greater than mild was more frequent with SEVs at BEV-dominant centers and similar with BEVs regardless of center dominance (5.2% vs 2.8% [P < 0.001] and 3.4% vs 3.7% [P = 0.504], respectively). Two-year mortality was higher with SEVs at BEV-dominant centers but not at SEV-dominant centers (21.9% vs 16.9% [P = 0.021] and 16.8% vs 16.5% [P = 0.642], respectively; HR: 1.20; P for interaction = 0.032). CONCLUSIONS: Periprocedural outcomes, aortic regurgitation greater than mild, and 2-year mortality are worse when TAVR is performed using SEVs at BEV-dominant centers. Outcomes are similar regardless of valve type at SEV-dominant centers. The present results stress the need to account for this factor when comparing BEV and SEV outcomes. (The Aortic+Mitral Transcatheter [AMTRAC] Valve Registry; NCT04031274).


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
16.
J Am Coll Cardiol ; 79(6): 562-573, 2022 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-35144748

RESUMEN

BACKGROUND: Risk stratification for transcatheter edge-to-edge mitral valve repair (TEER) is paramount in the decision-making process for treating severe mitral regurgitation (MR). OBJECTIVES: This study sought to create and validate a user-friendly score (MitraScore) to predict the risk of mortality in patients undergoing TEER. METHODS: The derivation cohort was based on a multicentric international registry that included 1,119 patients referred for TEER between 2012 and 2020. Score discrimination was assessed using Harrell's c-statistic, and the calibration was evaluated with the Gronnesby and Borgan goodness-of-fit test. An external validation was carried out in 725 patients from the GIOTTO registry. RESULTS: After multivariate analysis, we identified 8 independent predictors of mortality during the follow-up (2.1 ± 1.8 years): age ≥75 years, anemia, glomerular filtrate rate <60 mL/min/1.73 m2, left ventricular ejection fraction <40%, peripheral artery disease, chronic obstructive pulmonary disease, high diuretic dose, and no therapy with renin-angiotensin system inhibitors. The MitraScore was derived by assigning 1 point to each independent predictor. The c-statistic was 0.70. Per each point of the MitraScore, the relative risk of mortality increased by 55% (HR: 1.55; 95% CI: 1.44-1.67; P < 0.001). The discrimination and calibration for mortality prediction was better than those of EuroSCORE II (c-statistic 0.61) or Society of Thoracic Surgeons score (c-statistic 0.57). The MitraScore maintained adequate performance in the validation cohort (c-statistic 0.66). The score was also predictive for heart failure rehospitalization and was correlated with the probability of clinical improvement. CONCLUSIONS: The MitraScore is a simple prediction algorithm for the prediction of follow-up mortality in patients treated with TEER.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Complicaciones Posoperatorias/mortalidad , Sistema de Registros , Anciano , Femenino , Estudios de Seguimiento , Humanos , Italia/epidemiología , Masculino , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Estudios Retrospectivos , Factores de Riesgo , Volumen Sistólico/fisiología , Factores de Tiempo , Resultado del Tratamiento
18.
EuroIntervention ; 17(16): 1289-1297, 2022 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-34673502

RESUMEN

BACKGROUND: The mean age of transcatheter aortic valve implantation (TAVI) patients is steadily decreasing. AIMS: The aim of the study was to describe the characteristics, the indications for and the outcomes of TAVI in patients <70 years old. METHODS: All patients undergoing TAVI (n=8,626) from the 18 participating centres between January 2007 and June 2020 were stratified by age (70). For patients <70, the indications for TAVI were extracted from Heart Team discussions and the baseline characteristics and mortality were compared between the two groups. RESULTS: Overall, 640 (7.4%) patients were <70 (9.1% during 2018-2020, p<0.001); the mean age was 65.0±2.3 years. The younger patients were more often male, with bicuspid valves or needing valve-in-valve procedures. They had a higher prevalence of lung disease and diabetes. In 80.7% of cases, the Heart Team estimated an increased surgical risk and TAVI was selected, reflected by an STS score >4% in 20.4%. Five-year mortality was similar (29.4 vs 29.8%, HR 0.95, p=0.432) in the <70 and >70 groups. In the <70 group, mortality was higher for those referred for TAVI due to an increased surgical risk compared to those referred for other reasons (31.6 vs 24.5%, HR 1.23, p=0.021). Mortality was similar regardless of the STS stratum in patients judged by the Heart Team to be at increased surgical risk (32.6 vs 30.4%, HR 0.98, p=0.715). CONCLUSIONS: Use of TAVI in patients <70 is becoming more frequent. The main reason for choosing TAVI is due to an increased surgical risk not adequately represented by the STS score. The outcomes for these patients are similar to those for older TAVI patients. Dedicated trials of TAVI/SAVR in younger patients are needed to guide decisions concerning expansion of TAVI indications. ((ClinicalTrials.gov: NCT04031274).


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
19.
J Cardiovasc Dev Dis ; 8(9)2021 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-34564131

RESUMEN

BACKGROUND: TAVR is a safe alternative to surgical aortic valve replacement (SAVR); however, sex-related differences are still debated. This research aimed to examine gender differences in a real-world transcatheter aortic valve replacement (TAVR) cohort. METHODS: All-comer aortic stenosis (AS) patients undergoing TAVR with a Medtronic valve across 19 Italian sites were prospectively included in the Italian Clinical Service Project (NCT01007474) between 2007 and 2019. The primary endpoint was 1-year mortality. We also investigated 3-year mortality, and ischemic and hemorrhagic endpoints, and we performed a propensity score matching to assemble patients with similar baseline characteristics. RESULTS: Out of 3821 patients, 2149 (56.2%) women were enrolled. Compared with men, women were older (83 ± 6 vs. 81 ± 6 years, p < 0.001), more likely to present severe renal impairment (GFR ≤ 30 mL/min, 26.3% vs. 16.3%, p < 0.001) but had less previous cardiovascular events (all p < 0.001), with a higher mean Society of Thoracic Surgeons (STS) score (7.8% ± 7.1% vs. 7.2 ± 7.5, p < 0.001) and a greater mean aortic gradient (52.4 ± 15.3 vs. 47.3 ± 12.8 mmHg, p < 0.001). Transfemoral TAVR was performed more frequently in women (87.2% vs. 82.1%, p < 0.001), with a higher rate of major vascular complications and life-threatening bleeding (3.9% vs. 2.4%, p = 0.012 and 2.5% vs. 1.4%, p = 0.024). One-year mortality differed between female and male (11.5% vs. 15.0%, p = 0.002), and this difference persisted after adjustment for significant confounding variables (Adj.HR1yr 1.47, 95%IC 1.18-1.82, p < 0.001). Three-year mortality was also significantly lower in women compared with men (19.8% vs. 24.9%, p < 0.001) even after adjustment for age, STS score, eGFR, diabetes and severe COPD (Adj.HR3yr 1.42, 95%IC 1.21-1.68, p < 0.001). These results were confirmed in 689 pairs after propensity score matching. CONCLUSION: Despite higher rates of peri-procedural complications, women presented better survival than men. This better adaptive response to TAVR may be driven by sex-specific factors.

20.
J Am Coll Cardiol ; 78(4): 297-313, 2021 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-34294267

RESUMEN

BACKGROUND: Device-related thrombus (DRT) has been considered an Achilles' heel of left atrial appendage occlusion (LAAO). However, data on DRT prediction remain limited. OBJECTIVES: This study constructed a DRT registry via a multicenter collaboration aimed to assess outcomes and predictors of DRT. METHODS: Thirty-seven international centers contributed LAAO cases with and without DRT (device-matched and temporally related to the DRT cases). This study described the management patterns and mid-term outcomes of DRT and assessed patient and procedural predictors of DRT. RESULTS: A total of 711 patients (237 with and 474 without DRT) were included. Follow-up duration was similar in the DRT and no-DRT groups, median 1.8 years (interquartile range: 0.9-3.0 years) versus 1.6 years (interquartile range: 1.0-2.9 years), respectively (P = 0.76). DRTs were detected between days 0 to 45, 45 to 180, 180 to 365, and >365 in 24.9%, 38.8%, 16.0%, and 20.3% of patients. DRT presence was associated with a higher risk of the composite endpoint of death, ischemic stroke, or systemic embolization (HR: 2.37; 95% CI, 1.58-3.56; P < 0.001) driven by ischemic stroke (HR: 3.49; 95% CI: 1.35-9.00; P = 0.01). At last known follow-up, 25.3% of patients had DRT. Discharge medications after LAAO did not have an impact on DRT. Multivariable analysis identified 5 DRT risk factors: hypercoagulability disorder (odds ratio [OR]: 17.50; 95% CI: 3.39-90.45), pericardial effusion (OR: 13.45; 95% CI: 1.46-123.52), renal insufficiency (OR: 4.02; 95% CI: 1.22-13.25), implantation depth >10 mm from the pulmonary vein limbus (OR: 2.41; 95% CI: 1.57-3.69), and non-paroxysmal atrial fibrillation (OR: 1.90; 95% CI: 1.22-2.97). Following conversion to risk factor points, patients with ≥2 risk points for DRT had a 2.1-fold increased risk of DRT compared with those without any risk factors. CONCLUSIONS: DRT after LAAO is associated with ischemic events. Patient- and procedure-specific factors are associated with the risk of DRT and may aid in risk stratification of patients referred for LAAO.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Cateterismo Cardíaco/efectos adversos , Complicaciones Posoperatorias/etiología , Sistema de Registros , Dispositivo Oclusor Septal/efectos adversos , Trombosis/etiología , Anciano , Apéndice Atrial/diagnóstico por imagen , Ecocardiografía Transesofágica , Europa (Continente)/epidemiología , Femenino , Estudios de Seguimiento , Cardiopatías/diagnóstico , Cardiopatías/epidemiología , Cardiopatías/etiología , Humanos , Incidencia , Masculino , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Factores de Riesgo , Tasa de Supervivencia/tendencias , Trombosis/diagnóstico , Trombosis/epidemiología , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...