1.
Bone ; 58: 81-91, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24120669

RESUMEN

It is well established that osteoblasts, the key cells involved in bone formation during development and in adult life, secrete a number of glycoproteins harboring autocrine and paracrine functions. Thus, investigating the osteoblastic secretome could yield important information for the pathophysiology of bone. In the present study, we characterized for the first time the secretome of human Hobit osteoblastic cells. We discovered that the secretome comprised 89 protein species including the powerful growth factor progranulin. Recombinant human progranulin (6nM) induced phosphorylation of mitogen-activated protein kinase in both Hobit and osteocytic cells and induced cell proliferation and survival. Notably, risedronate, a nitrogen-containing bisphosphonate widely used in the treatment of osteoporosis, induced the expression and secretion of progranulin in the Hobit secretome. In addition, our proteomic study of the Hobit secretome revealed that risedronate induced the expression of ERp57, HSP60 and HSC70, three proteins already shown to be associated with the prevention of bone loss in osteoporosis. Collectively, our findings unveil novel targets of risedronate-evoked biological effects on osteoblast-like cells and further our understanding of the mechanisms of action of this currently used compound.


Asunto(s)
Ácido Etidrónico/análogos & derivados , Péptidos y Proteínas de Señalización Intercelular/metabolismo , Osteoblastos/metabolismo , Proteoma/metabolismo , Animales , Western Blotting , Línea Celular , Supervivencia Celular/efectos de los fármacos , Electroforesis en Gel de Poliacrilamida , Ácido Etidrónico/farmacología , Humanos , Espectrometría de Masas , Ratones , Osteoblastos/efectos de los fármacos , Progranulinas , Reproducibilidad de los Resultados , Ácido Risedrónico , Factores de Tiempo
2.
J Am Soc Mass Spectrom ; 21(9): 1530-3, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20541437

RESUMEN

Traditionally, in a quadrupole mass filter, ion isolation is achieved by scanning the rf and DC voltages with a fixed ratio. In this paper, we describe an innovative procedure implemented in a digitally driven linear ion trap termed digital asymmetric waveform isolation (DAWI) in which ion isolation is obtained by manipulation of the duty cycle of the rectangular waveforms. Variation of the waveform duty cycle allows introduction of a precisely defined DC quadrupole component into the main trapping field of the quadrupole ion filter. The DAWI method is completely controlled at software level and does not require any hardware modification.


Asunto(s)
Espectrometría de Masas/métodos , Espectrometría de Masa por Ionización de Electrospray/instrumentación , Espectrometría de Masa por Ionización de Electrospray/métodos , Análisis de Fourier , Espectrometría de Masas/instrumentación , Procesamiento de Señales Asistido por Computador , Análisis de Ondículas
3.
J Am Soc Mass Spectrom ; 20(7): 1327-33, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19372050

RESUMEN

In this study, classic molecular dynamics (MD) simulations followed by density functional theory (DFT) calculations are employed to calculate the proton transfer reaction enthalpy shifts for native and derivatized peptide ions in the MALDI plume. First, absolute protonation and deprotonation enthalpies are calculated for native peptides (RPPGF and AFLDASR), the corresponding hexyl esters and three common matrices alpha-cyano-4-hydroxycinnamic acid (4HCCA), 2,5-dihydroxybenzoic acid (DHB), and 6 aza-2-thiothymine (ATT). From the proton exchange reaction calculations, protonation and deprotonation of the neutral peptides are thermodynamically favorable in the gas phase as long as the corresponding protonated/deprotonated matrix ions are present in the plume. Moreover, the gain in proton affinity shown by the ester ions suggests that the increase in ion yield is likely to be related to an easier proton transfer from the matrix to the peptide.


Asunto(s)
Gases/química , Modelos Químicos , Péptidos/química , Protones , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Ácidos Cumáricos/química , Esterificación , Gentisatos/química , Modelos Moleculares , Reproducibilidad de los Resultados , Termodinámica , Timina/análogos & derivados , Timina/química , Triazinas
4.
Anal Chem ; 81(9): 3392-7, 2009 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-19354287

RESUMEN

Small-angle X-ray scattering is a technique for the characterization and structural analysis of a variety of materials including biological macromolecules and polymers. For the conformational analysis of proteins, the interaction between sample and X-rays is generally performed when the proteins are present in solution. Here a three-dimensional digital ion trap interfaced with a high intensity X-ray source is built to prove that X-ray scattering can be performed on ions isolated in gas-phase. Initial experiments on an unresolved ion population of multiply charged cytochrome C ions indicate that a small-angle X-ray scattering signal can be detected and that partial structural information can be extracted about the overall molecular structure of protein ions.


Asunto(s)
Biopolímeros/química , Gases/química , Espectrometría de Masas/métodos , Difracción de Rayos X , Citocromos c/química , Diseño de Equipo , Espectrometría de Masas/instrumentación , Péptidos/química , Dispersión del Ángulo Pequeño
6.
Comb Chem High Throughput Screen ; 12(2): 185-93, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19199886

RESUMEN

Hyphenation with liquid chromatography has become indispensable in mass spectrometry-based proteomics. Sample complexity together with the large variations in dynamic range can be only tackled using techniques that isolate and/or concentrate individual components prior to mass spectrometric analysis. In this review the most recent developments in micro/nanoliquid chromatography interfaced with MALDI and electrospray ionisation are discussed. Particular attention is focused on all applications related to quantitative proteomics.


Asunto(s)
Cromatografía Liquida/métodos , Espectrometría de Masas/métodos , Sistemas en Línea , Proteómica/métodos , Cromatografía Liquida/instrumentación , Espectrometría de Masas/instrumentación , Proteínas/análisis , Proteínas/química , Espectrometría de Masa por Ionización de Electrospray/instrumentación , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/instrumentación , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Coloración y Etiquetado/métodos
7.
J Proteome Res ; 8(3): 1131-42, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19226166

RESUMEN

We combined high-throughput screening of differential mRNAs with mass spectrometric characterization of proteins obtained from osteocytes untreated and treated with Risedronate. Microarray analysis revealed, upon treatment, a marked upregulation of messengers encoding zinc-proteins. MS analysis identified 84 proteins in the osteocytes proteome map. Risedronate affected the expression of 10 proteins, associated with cytoskeleton, stress-response and metabolism. Data validated using gel imaging in combination with the GLaD post digestion isotopic labeling method provide the molecular basis for understanding the role of bisphosphonates as antiapoptotic drugs for osteocytes.


Asunto(s)
Difosfonatos/farmacología , Ácido Etidrónico/análogos & derivados , Osteocitos/metabolismo , Proteoma/metabolismo , ARN Mensajero/metabolismo , Animales , Conservadores de la Densidad Ósea/farmacología , Células Cultivadas , Cromatografía Liquida , Electroforesis en Gel Bidimensional , Ácido Etidrónico/farmacología , Perfilación de la Expresión Génica , Marcaje Isotópico/métodos , Osteocitos/efectos de los fármacos , Ácido Risedrónico , Espectrometría de Masa por Ionización de Electrospray
8.
J Am Soc Mass Spectrom ; 19(4): 620-5, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18296062

RESUMEN

In a digital ion trap the beta(r) and beta(z) boundary lines of the stability diagram are determined experimentally using an innovative approach. In the rectangular waveform-driven digital ion trap (DIT) manipulation of the waveform duty cycle allows introduction of a precisely defined DC quadrupole component into the main trapping field. Variation of the duty cycle can be controlled at software level without any hardware modification. The data generated use peptide ions, which produce stability diagrams in good agreement with the theoretical stability diagrams previously determined by simulation studies.

9.
Rapid Commun Mass Spectrom ; 21(18): 3069-76, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17708507

RESUMEN

A new generation of guanidino-labelling (GLaD) reagents were developed for quantitative proteomics using offline microcapillary liquid chromatography (LC) matrix-assisted laser desorption/ionisation mass spectrometry (MALDI-MS). In order to reduce the unwanted overlapping between the isotopic envelopes of the two differentially labelled peptide ions, a novel synthetic route was described for production of both (13)C- and (15)N-containing isotopomers of N,O-dimethylisourea. The use of these types of isotopes has no deleterious effect on the retention times of both differentially labelled peptides during offline microbore reversed-phase LC. In addition, the possibility to incorporate a mass difference of 4 Da can be exploited during post-source decay analysis to generate product ion spectra in which fragment ions containing the modifications appear as doublets in the corresponding product ion spectra, thus facilitating identification of the C-terminal fragment ions.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Guanidina/química , Indicadores y Reactivos/química , Mapeo Peptídico/métodos , Proteínas/química , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Coloración y Etiquetado/métodos
10.
Mol Nutr Food Res ; 51(4): 456-61, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17357982

RESUMEN

Advanced glycation end-product (AGE)/peptides, arising from in vivo digestion of glycated proteins, are biologically important compounds, due to their reactivity against circulating and tissue proteins. For information on their possible structure, in vitro glycation of HSA and its further enzymatic digestion were performed. The resulting digestion product mixture was analysed directly by MALDI MS with various matrices [2,5-dihydroxy benzoic acid (DHB) and alpha-cyano-4-hydroxy cinnamic acid (CHCA)]. Alternatively, offline microbore LC prior to MALDI analysis was used, and showed that 63% of the free amino groups prone to glycation are modified, indicating the contemporary presence of unglycated peptides. This result proves that, regardless of the high glucose concentration employed for HSA incubation, glycation does not go to completion. Further studies showed that the collisionally activated decomposition of singly charged glycated peptides leads to specific fragmentation pathways, all related to the condensed glucose molecule. These unique product ions can be used as effective markers to establish the presence of a glucose molecule within a peptide ion.


Asunto(s)
Fragmentos de Péptidos/análisis , Albúmina Sérica/química , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Tripsina/metabolismo , Productos Finales de Glicación Avanzada , Humanos , Fragmentos de Péptidos/metabolismo , Albúmina Sérica/metabolismo , Albúmina Sérica Glicada
11.
J Am Soc Mass Spectrom ; 18(2): 201-7, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17067813

RESUMEN

Development of a quantification method based on isotopic variants of O-methyl isourea (OMIU) in conjunction with reversed-phase (RP) liquid chromatography (LC) electrospray mass spectrometry is described for determining the relative quantification of tau-related peptides Ac-VQIVXK-NH2. Extracted ion chromatograms of the mass spectrometric data derived from online microcapillary LC separation identifies the retention times of the isotopically derivatized peptides together with their ion abundances. Data-dependent MSMS analysis of both derivatized variants of the same peptide provides a complementary method for identification and resolution between isobaric species. In addition, with respect to offline LC MALDI a larger number of analogues are detected and formation of amyloid is also observed for the aspartic acid and histidine-containing peptides.


Asunto(s)
Guanidinas/química , Oligopéptidos/análisis , Espectrometría de Masa por Ionización de Electrospray/métodos , Proteínas tau/análisis , Amiloide/química , Cromatografía Líquida de Alta Presión , Compuestos de Metilurea/química , Mutación , Oligopéptidos/química , Mapeo Peptídico , Isoformas de Proteínas , Proteínas tau/química
12.
J Mass Spectrom ; 41(9): 1179-85, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16924599

RESUMEN

Glycated peptides arising from in vivo digestion of glycated proteins, usually called advanced glycation end (AGE) product peptides, are biologically relevant compounds due to their reactivity towards circulating and tissue proteins. To investigate their structures, in vitro glycation of human serum albumin (HSA) has been performed and followed by enzymatic digestion. Using different MALDI based approaches the digestion products obtained have been compared with those arising from enzymatic digestion of the protein. Results obtained using 2,5-dihydroxybenzoic acid (DHB) indicate this as the most effective matrix, leading to an increase in the coverage of the glycated protein. Off-line microbore liquid chromatography prior to MALDI analysis reveals that 63% of the free amino groups amenable to glycation are modified. In addition, the same approach shows the co-presence of underivatised peptides. This indicates that, regardless of the high glucose concentration employed for HSA incubation, glycation does not go to completion. Tandem mass spectrometric data suggest that the collision induced dissociation of singly charged glycated peptides leads to specific fragmentation pathways related to the condensed glucose molecule. The specific neutral losses derived from the activated glycated peptides can be used as signature for establishing the occurrence of glycation processes.


Asunto(s)
Productos Finales de Glicación Avanzada/análisis , Péptidos/análisis , Albúmina Sérica/análisis , Secuencia de Aminoácidos , Cromatografía Liquida , Humanos , Datos de Secuencia Molecular , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Tripsina
13.
Rapid Commun Mass Spectrom ; 20(11): 1653-60, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16636997

RESUMEN

A commercial matrix-assisted laser desorption/ionisation time-of-flight (MALDI-ToF) instrument equipped with a curved field reflectron (CFR) was modified in order to perform collision-induced dissociation (CID) on a variety of biomolecules. The incorporation of a high-resolution ion gate together with a collision cell within the field-free region allowed tandem mass analysis (MS/MS), without the necessity to decelerate the precursor ions prior to activation. The simultaneous detection of all product ions remained possible by using the CFR. To test the MS/MS performances, ACTH (fragment 1-17), a complex high mannose carbohydrate (Man)(8)(GlcNac)(2) and a lysophosphatidylcholine lipid (18:1) were analysed on the modified instrument. Direct comparison with the low-energy product ion spectra, acquired on a MALDI quadrupole ion trap (QIT) two-stage reflectron time-of flight (ReToF) mass spectrometer, showed significant differences in the types of product ions observed. The additional ions detected were a clear indication of the high-energy fragmentation processes occurring in the collision cell.


Asunto(s)
Oligosacáridos/química , Péptidos/química , Fosfolípidos/química , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/instrumentación , Hormona Adrenocorticotrópica/análisis , Secuencia de Aminoácidos , Secuencia de Carbohidratos , Helio , Indicadores y Reactivos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Espectrometría de Masas en Tándem , Rayos Ultravioleta
14.
Biochemistry ; 45(14): 4638-52, 2006 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-16584199

RESUMEN

Physical properties, including amyloid morphology, FTIR and CD spectra, enhancement of Congo red absorbance, polymerization rate, critical monomer concentration, free energy of stabilization, hydrophobicity, and the partition coefficient between soluble and amyloid states, were measured for the tau-related peptide Ac-VQIVYK amide (AcPHF6) and its single site mutants Ac-VQIVXK amide (X not equal Cys). Transmission electron microscopy showed that 15 out of the 19 peptides formed amyloid in buffer, with morphologies ranging from straight and twisted filaments to sheets and rolled sheets. Using principal component analysis (PCA), measured properties were treated in a comprehensive manner, and scores along the most significant principal components were used to define individual amino acid amyloidogenic propensities. Quantitative structure-activity modeling (QSAM) showed that residues with greater size and hydrophobicity made the largest contributions to the propensity of peptides to form amyloid. Using individual amino acid propensities, sequences within tau with high amyloid-forming potential were estimated and found to include 226VAVVR230 in the proline-rich region, 275VQIINK280 (PHF6) and 306VQIVYK311 (PHF6) within the microtubule binding region, and 392IVYK395 in the C-tail region of the protein. The results suggest that regions outside the microtubule-binding region may play important roles in tau aggregation kinetics or paired helical filament structure.


Asunto(s)
Amiloide/química , Oligopéptidos/química , Proteínas tau/química , Sustitución de Aminoácidos , Amiloide/ultraestructura , Dicroismo Circular , Rojo Congo , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Microscopía Electrónica de Transmisión , Análisis de Componente Principal , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Espectrofotometría Infrarroja , Espectroscopía Infrarroja por Transformada de Fourier , Termodinámica , Proteínas tau/ultraestructura
15.
Anal Chem ; 78(6): 1995-2000, 2006 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-16536438

RESUMEN

Electron capture dissociation was implemented in a digital ion trap without using any magnetic field to focus the electrons. Since rectangular waveforms are employed in the DIT for both trapping and dipole excitation, electrons can be injected into the trap when the electric field is constant. Following deceleration, electrons reach the precursor ion cloud. The fragment ions produced by interactions with the electron beam are subsequently analyzed by resonant ejection. [Glu(1)]-Fibrinopeptide B and substance P were used to evaluate the performance of the current design. Fragmentation efficiency of 5.5% was observed for substance P peptide ions. Additionally, analysis of the monophosphorylated peptide FQ[pS]EEQQQTEDELQDK shows that in the resulting c- and z-type ions, the phosphate group is retained on the phophoserine residue, providing information on which amino acid residue the modification is located.


Asunto(s)
Fibrinopéptido B/análisis , Sustancia P/análisis , Espectrometría de Masas en Tándem/métodos , Electrones , Fragmentos de Péptidos/análisis , Fosforilación , Sensibilidad y Especificidad
16.
Expert Rev Proteomics ; 3(1): 143-51, 2006 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16445358

RESUMEN

Due to their versatility, quadrupole ion traps have become popular mass spectrometers in the growing field of proteomics. High sensitivity, user friendliness and low cost are the key features that have contributed to the success of the technology. However, mass measurement accuracy, resolution and mass range are still not comparable to the analytical performances obtained on other mass spectrometers. In the past 5 years, researchers have tried to overcome these drawbacks, focusing their attention on two different aspects of ion-trap mass spectrometry, development of novel types of ion traps and manipulation of the gas-phase ion chemistry, in order to obtain alternative techniques for tandem mass spectrometry analysis. In the field of trapping devices, improvements in instrumental design have led to the linear ion trap, digital ion trap and orbitrap. Activation methods based on electrons, chemically produced by an anion or from irradiation with an electron beam, have demonstrated their utility in providing complementary sequence information for improving confidence in protein identification.


Asunto(s)
Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masa por Ionización de Electrospray/tendencias , Animales , Electrones
17.
J Am Soc Mass Spectrom ; 16(8): 1269-74, 2005 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-15975823

RESUMEN

Esterification was used to investigate how introduction of aliphatic chains within the peptide structure affects the MALDI response of ions analyzed in both polarity regimes. In binary mixtures containing equimolar amounts of a peptide with its correspondent alkyl ester, derivatization of the carboxylic groups has the tendency to increase MALDI detection of the modified protonated peptide ions. This positive effect on ion yield is more pronounced when longer alcohols are employed. In negative mode, the situation is antithetic and esterification produces a deleterious effect on the ion yield of the corresponding deprotonated species. From the data reported here we postulate that modifications of the acidic character of peptides prevent formation of anionic species under MALDI analysis. Furthermore, suppression of the formation pathway for anions alters the overall number of molecules which can undergo protonation. This results in an increased ion yield for the protonated esters.


Asunto(s)
Ésteres/análisis , Péptidos/análisis , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Alcoholes , Secuencia de Aminoácidos , Esterificación , Ésteres/química , Interacciones Hidrofóbicas e Hidrofílicas , Datos de Secuencia Molecular , Péptidos/química , Protones
19.
J Mass Spectrom ; 39(5): 471-84, 2004 May.
Artículo en Inglés | MEDLINE | ID: mdl-15170743

RESUMEN

In a digital ion trap (DIT), the quadrupole trapping and excitation waveforms are generated by the rapid switching between discrete d.c. voltage levels. As the timing of the switch can be controlled precisely by digital circuitry, the approach provides an opportunity to generate mass spectra by means of a frequency scan in contrast to the conventional voltage scan, thus providing a wider mass range of analysis. An instrument has been constructed which employs a 'non-stretched' ion trap and the field fault around the aperture of the end-cap electrode can be corrected electronically using a field-adjusting electrode. The ion trap was coupled with electrospray ionization (ESI) and atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) sources to demonstrate the capability of the digital method. AP-MALDI mass spectra of singly charged ions with mass-to-charge ratios upto 17 000 Th were generated using a trapping voltage of only 1000 V. Forward and reverse mass scans at resolutions up to 19 000 and precursor ion isolation at resolutions up to 3500 with subsequent tandem mass spectrometric analysis were demonstrated. The method of generating the digital waveforms and period scan is described. Discussion of the issues of mass range, scan speed, ion trapping efficiency and collision-induced dissociation efficiency are also provided.


Asunto(s)
Presión Atmosférica , Espectrometría de Masas/instrumentación , Espectrometría de Masas/métodos , Animales , Iones , Péptidos/análisis , Péptidos/química
20.
Anal Chem ; 76(10): 2748-55, 2004 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-15144184

RESUMEN

Guanidination performed with isotopic isoforms of O-methylisourea was used in combination with reversed-phase liquid chromatography (LC) matrix-assisted laser desorption/ionization to characterize, both qualitatively and quantitatively, protein mixtures. Synthesis of (13)C- and (15)N(2)-labeled O-methylisourea sulfate produces a molecule that is 3 Da heavier than the light isotopic variant. Protein mixtures containing identical components in different concentration are pooled together following parallel derivatization. Relative quantification of protein mixtures is achieved by mass spectrometry. A difference of 3 Da allows negligible interference between the two isotopic clusters for quantification of peptides up to 1400 Da. Under these conditions, the chromatographic resolution achieved allows separation of different pairs of derivatized peptides without altering the retention time of structurally identical isotopic isoforms. Concomitant isolation of both chemically modified precursors is followed by tandem mass analysis. Activation of the ions via collisions with an inert gas produces isotopically derivatized fragment ions, which appear as doublets in the product ion spectrum. Since the modification occurs on the C-terminal lysine, ions incorporating the guanidino moiety on the C-terminus can be distinguished from those containing the original unmodified peptide N-terminus. Knowledge of the location of the proton can be beneficial to data interpretation and peptide sequencing.


Asunto(s)
Cromatografía Liquida/métodos , Guanidinas/química , Péptidos/análisis , Proteínas/análisis , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Marcaje Isotópico , Lisina/química , Compuestos de Metilurea/química , Isoformas de Proteínas/química , Análisis de Secuencia/métodos , Sulfatos/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA