Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 83(10): 10E343, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23127000

RESUMEN

Validation of models of pedestal structure is an important part of predicting pedestal height and performance in future tokamaks. The Thomson scattering diagnostic at DIII-D has been upgraded in support of validating these models. Spatial and temporal resolution, as well as signal to noise ratio, have all been specifically enhanced in the pedestal region. This region is now diagnosed by 20 view-chords with a spacing of 6 mm and a scattering length of just under 5 mm sampled at a nominal rate of 250 Hz. When mapped to the outboard midplane, this corresponds to ~3 mm spacing. These measurements are being used to test critical gradient models, in which pedestal gradients increase in time until a threshold is reached. This paper will describe the specifications of the upgrade and present initial results of the system.

2.
QJM ; 105(11): 1097-103, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22908320

RESUMEN

BACKGROUND: Central venous catheters (CVC) are a potential source of bacteraemia and have been associated with increased mortality in haemodialysis patients. We aimed to investigate the relationships between haemodialysis vascular access, taking into account changes in vascular access type during patients' lives, and cause specific mortality risk in a national cohort of dialysis patients. METHODS: Prospective cohort study including all patients receiving haemodialysis in Scotland at annual cross sectional surveys in 2009, 2010 and 2011. Data were collected through the Scottish Renal Registry and by a structured review of case records following death. Cox proportional hazards regression and multivariable logistic regression were used to model survival and risk of death from septicaemia respectively. RESULTS: Of a cohort of 2666 patients, 873 (32%) died during follow-up. After case-mix adjustment, patients using only tunnelled CVC during follow-up had a higher risk of all cause mortality across all strata of prior renal replacement therapy exposure [adjusted hazard ratio (HR): 1.83-2.08]. Case-mix adjusted risks of cardiovascular death (adjusted HR: 2.20-2.95) and infection-related death (adjusted HR: 3.10-3.63) were also higher in this group. Patients using tunnelled CVCs during follow-up and prior to death had 6.9-fold higher odds of death from septicaemia compared with those using only arteriovenous fistulae or grafts. CONCLUSION: Compared with an arteriovenous fistula or graft, sustained use of tunnelled CVCs for vascular access is associated with higher risks of all-cause, cardiovascular and infection-related mortality.


Asunto(s)
Bacteriemia/mortalidad , Cateterismo Venoso Central/efectos adversos , Sistema de Registros , Diálisis Renal/mortalidad , Insuficiencia Renal/mortalidad , Adulto , Anciano , Cateterismo Venoso Central/estadística & datos numéricos , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo , Reino Unido
3.
Rev Sci Instrum ; 81(10): 10D525, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21033880

RESUMEN

The DIII-D Thomson scattering system has been upgraded. A new data acquisition hardware was installed, adding the capacity for additional spatial channels and longer acquisition times for temperature and density measurements. Detector modules were replaced with faster transimpedance circuitry, increasing the signal-to-noise ratio by a factor of 2. This allows for future expansion to the edge system. A second phase upgrade scheduled for 2010-2011 includes the installation of four 1 J/pulse Nd:YAG lasers at 50 Hz repetition rate. This paper presents the first completed phase of the upgrade and performance comparison between the original system and the upgraded system. The plan for the second phase is also presented.

4.
Phys Rev Lett ; 103(16): 165005, 2009 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-19905705

RESUMEN

Good alignment of the magnetic field line pitch angle with the mode structure of an external resonant magnetic perturbation (RMP) field is shown to induce modulation of the pedestal electron pressure p(e) in high confinement high rotation plasmas at the DIII-D tokamak with a shape similar to ITER, the next step tokamak experiment. This is caused by an edge safety factor q95 resonant enhancement of the thermal transport, while in contrast, the RMP induced particle pump out does not show a significant resonance. The measured p(e) reduction correlates to an increase in the modeled stochastic layer width during pitch angle variations matching results from resistive low rotation plasmas at the TEXTOR tokamak. These findings suggest a field line pitch angle resonant formation of a stochastic magnetic edge layer as an explanation for the q95 resonant character of type-I edge localized mode suppression by RMPs.

5.
Rev Sci Instrum ; 79(10): 10F303, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19044616

RESUMEN

Dust production and accumulation present potential safety and operational issues for the ITER. Dust diagnostics can be divided into two groups: diagnostics of dust on surfaces and diagnostics of dust in plasma. Diagnostics from both groups are employed in contemporary tokamaks; new diagnostics suitable for ITER are also being developed and tested. Dust accumulation in ITER is likely to occur in hidden areas, e.g., between tiles and under divertor baffles. A novel electrostatic dust detector for monitoring dust in these regions has been developed and tested at PPPL. In the DIII-D tokamak dust diagnostics include Mie scattering from Nd:YAG lasers, visible imaging, and spectroscopy. Laser scattering is able to resolve particles between 0.16 and 1.6 microm in diameter; using these data the total dust content in the edge plasmas and trends in the dust production rates within this size range have been established. Individual dust particles are observed by visible imaging using fast framing cameras, detecting dust particles of a few microns in diameter and larger. Dust velocities and trajectories can be determined in two-dimension with a single camera or three-dimension using multiple cameras, but determination of particle size is challenging. In order to calibrate diagnostics and benchmark dust dynamics modeling, precharacterized carbon dust has been injected into the lower divertor of DIII-D. Injected dust is seen by cameras, and spectroscopic diagnostics observe an increase in carbon line (CI, CII, C(2) dimer) and thermal continuum emissions from the injected dust. The latter observation can be used in the design of novel dust survey diagnostics.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...