Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
2.
Int Angiol ; 42(1): 80-87, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36744424

RESUMEN

BACKGROUND: Measurement of volume has the potential to detect subtle growth not recognized in the current surveillance paradigm of abdominal aortic aneurysms (AAAs). Currently available three-dimensional ultrasound allows for estimation of AAA volume, but for most patients, the AAA extends beyond the ultrasound field-of-view and only allows visualization of a partial AAA volume. A new extended field-of-view three-dimensional ultrasound protocol (XFoV US) has been found to improve the proportion of patients with visualization of the full AAA volume. METHODS: To investigate the applicability of the XFoV US protocol in estimating AAA volume growth in follow-up, 86 patients with AAAs were recruited from the surveillance program at a university hospital. All were imaged by XFoV US at baseline and at one-year follow-up. RESULTS: Assessment of full volume, based on visualization of the AAA neck and bifurcation at both baseline and one-year follow-up, was achieved in 67/86 (78%) of patients. One-year mean growth in maximum diameter was 2.8 mm (6%/year), in centerline length 2.9 mm (4%/year), and in volume 15.9 mL (19%/year). In 17/67 (25%) of patients, volume growth was detected in diameter-stable AAAs. Baseline XFoV US volume was associated with one-year AAA volume growth, while, conversely, maximum baseline diameter was not associated with one-year AAA diameter growth. CONCLUSIONS: This study concludes that the XFoV US protocol provides a safe and repeatable modality for assessing AAA volume growth, and that AAA volume is a promising predictive measure of AAA growth.


Asunto(s)
Aneurisma de la Aorta Abdominal , Humanos , Aneurisma de la Aorta Abdominal/complicaciones , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Ultrasonografía , Imagenología Tridimensional
3.
Ultrasound Med Biol ; 48(2): 283-292, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34823944

RESUMEN

Three-dimensional ultrasound (US) of abdominal aortic aneurysms (AAAs) is limited by the field-of-view of the 3D-US transducer. To obtain an extended field-of-view (XFoV), two transducer navigation system-assisted US protocols have been developed: XFoV-2D and XFoV-3D. In this study, the XFoV US protocols were compared with the currently available 3D-US protocol with standard field-of-view (FoV-st) and the established gold standard, computed tomography angiography (CTA). A total of 65 patients with AAA were included, and AAA imaging was processed offline with prototype software. The novel XFoV-2D and XFoV-3D protocols allowed for assessment of full AAA volume in significantly more patients (45/65 [69%] and 43/65 [66%], respectively), compared with the current 3D-US standard, FoV-st (30/65 [46%] patients). The mean difference in AAA volume estimation between each XFoV US protocol and 3-D CTA differed significantly (XFoV-2D: 16.9 mL, XFoV-3D: 7.6 mL, p = 0.002), indicating that XFoV-3D agreed best with 3D-CTA. No significant difference was found in the variance of full AAA volume quantification between each XFoV US protocol and CTA (p = 0.49). It is concluded that the XFoV US protocols improved the generation of full AAA volumes compared with the currently available 3D-US technology, with AAA volume estimates comparable to CTA estimates.


Asunto(s)
Aneurisma de la Aorta Abdominal , Angiografía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Humanos , Imagenología Tridimensional , Reproducibilidad de los Resultados
4.
Ann Vasc Surg ; 77: 187-194, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34437978

RESUMEN

BACKGROUND: Abdominal aortic aneurysm (AAA) surveillance programs are currently based solely on AAA diameter. The diameter criterion alone, however, seems inadequate as small AAAs comprise 5-10 % of ruptured AAAs as well as some large AAAs never rupture. Aneurysm wall stiffness has been suggested to predict rupture and growth; this study aimed to investigate the prognostic value of AAA vessel wall stiffness for growth on prospectively collected data. METHODS: Analysis was based on data from a randomised, placebo-controlled, multicentre trial investigating mast-cell-inhibitors to halt aneurysm growth (the AORTA trial). Systolic and diastolic AAA diameter was determined in 326 patients using electrocardiogram-gated ultrasound (US). Stiffness was calculated at baseline and after 1 year. RESULTS: Maximum AAA diameter increased from 44.1 mm to 46.5 mm during the study period. Aneurysm growth after 1 year was not predicted by baseline stiffness (-0.003 mm/U; 95 % CI: -0.007 to 0.001 mm/U; P = 0.15). Throughout the study period, stiffness remained unchanged (8.3 U; 95 % CI: -2.5 to 19.1 U; P = 0.13) and without significant correlation to aneurysm growth (R: 0.053; P = 0.38). CONCLUSIONS: Following a rigorous US protocol, this study could not confirm AAA vessel wall stiffness as a predictor of aneurysm growth in a 1-year follow-up design. The need for new and subtle methods to complement diameter for improved AAA risk assessment is warranted.


Asunto(s)
Aorta/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Ultrasonografía , Rigidez Vascular , Espera Vigilante , Anciano , Aorta/fisiopatología , Aneurisma de la Aorta Abdominal/fisiopatología , Fenómenos Biomecánicos , Dinamarca , Progresión de la Enfermedad , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Ensayos Clínicos Controlados Aleatorios como Asunto , Medición de Riesgo , Factores de Riesgo , Suecia , Factores de Tiempo , Reino Unido
5.
J Vasc Surg ; 74(5): 1644-1650, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33940074

RESUMEN

OBJECTIVE: Conventional two-dimensional ultrasound (2D-US) has been the recommended and preferred modality for the diagnosis and surveillance of abdominal aortic aneurysms (AAAs). Measurement of the aneurysm diameter using three-dimensional ultrasound (3D-US) has shown promising results in a research setting, improving agreement and reproducibility. However, studies evaluating 3D-US in a clinical context are lacking, which could hinder the optimal usage of this new modality. In the present study, we investigated the clinical value of 3D-US for AAA surveillance compared with the current standard 2D-US examination. METHODS: Data from 126 patients with infrarenal AAAs <50 mm and 55 mm (female and male, respectively) were available for analysis. Eligibility was determined using the standard 2D-US anteroposterior (AP) diameter with a dual-plane technique. All the patients had subsequently undergone additional 3D-US and computed tomography angiography (CTA). Using CTA as the reference standard, the maximal standard 2D-US AP diameter was compared with that from 3D-US. RESULTS: All 126 AAAs were, per the inclusion criteria, small, with no intervention indicated. With the addition of 3D-US imaging to the 2D-US-based surveillance program, the AAA diameter threshold (50 and 55 mm) was exceeded for 31 of the 126 patients (25%). These 31 patients were withdrawn from the present study and referred for treatment planning. Compared with the CTA AP diameter (mean, 49 ± 7.2 mm), the mean 3D-US AP diameter (mean, 49 ± 6.7 mm) was significantly more accurate than the standard mean 2D-US AP diameter (45 ± 6.2 mm; kappa value, 0.86 ± 0.05; 95% confidence interval, 0.76-0.96; kappa value, 0.01 ± 0.04; 95% confidence interval, -0.05 to 0.09, respectively). CONCLUSIONS: For clinical use, the AAA diameter assessment using 3D-US was significantly more accurate than that with 2D-US and can substantially change the clinical management, from surveillance to operative treatment, for approximately one fourth of patients with an AAA. Further studies evaluating the clinical consequences of the 2D to 3D paradigm shift in AAA diagnostics are warranted, including sensitivity, specificity, agreement, and reproducibility estimation.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Imagenología Tridimensional , Ultrasonografía , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/cirugía , Aortografía , Toma de Decisiones Clínicas , Angiografía por Tomografía Computarizada , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Pronóstico , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Tiempo
6.
J Vasc Surg ; 74(3): 979-987, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33684470

RESUMEN

OBJECTIVE: Three-dimensional ultrasound (3D-US) has already demonstrated improved reproducibility with a high degree of agreement (intermodality variability), reproducibility (interoperator variability), and repeatability (intraoperator variability) compared with conventional two-dimensional ultrasound (2D-US) when estimating the maximum diameter of native abdominal aortic aneurysms (AAAs). The aim of the present study was, in a clinical, multicenter setting, to evaluate the accuracy of 3D-US with aneurysm model quantification software (3D-US abdominal aortic aneurysm [AAA] model) for endovascular aortic aneurysm repair (EVAR) sac diameter assessment vs that of computed tomography angiography (CTA) and 2D-US. METHODS: A total of 182 patients who had undergone EVAR from April 2016 to December 2017 and were compliant with a standardized EVAR surveillance program were enrolled from five different vascular centers (Rigshospitalet, Copenhagen, Denmark; Catharina Ziekenhuis, Eindhoven, Netherlands; L'hospital de la Timone, Paris, France; Cleveland Clinic, Cleveland, Ohio; and The Christ Hospital, Cincinnati, Ohio) in four countries. All image acquisitions were performed at the local sites (ie, 2D-US, 3D-US, CTA). Only the 2D-US and CTA readings were performed both locally and centrally. All images were read centrally by the US and CTA core laboratory. Anonymized image data were read in a randomized and blinded manner. RESULTS: The sample used to estimate the accuracy of the 3D-US AAA model and 2D-US included 164 patients and 177 patients, respectively. The Bland-Altman analysis revealed that the mean difference between CTA and 3D-US was -2.43 mm (95% confidence interval [CI], -5.20 to 0.14; P = .07) with a lower and upper limit of agreement of -8.9 mm (95% CI, -9.3 to -8.4) and 2.7 mm (95% CI, 2.3-3.2), respectively. For 2D-US and CTA, the mean difference was -3.62 mm (95% CI, -6.14 to -1.10; P = .002), with a lower and upper limit of agreement of -10.3 mm (95% CI, -10.8 to -9.8) and 2.5 mm (95% CI, 2-2.9), respectively. CONCLUSIONS: The 3D-US AAA model showed no significant difference compared with CTA for measuring the anteroposterior diameter, indicating less bias for 3D-US compared with 2D-US. Thus, 3D-US with AAA model software is a viable modality for anteroposterior diameter assessment for surveillance after EVAR.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Imagenología Tridimensional , Complicaciones Posoperatorias/diagnóstico por imagen , Ultrasonografía , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía , Implantación de Prótesis Vascular/efectos adversos , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares/efectos adversos , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ohio , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Factores de Tiempo , Resultado del Tratamiento
7.
Ann Vasc Surg ; 72: 321-329, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33160060

RESUMEN

BACKGROUND: To compare aortic sac changes after endovascular aneurysm repair (EVAR) assessed by three-dimensional ultrasound (3D-US), two-dimensional ultrasound (2D-US), and traditional computed tomographic angiography (CTA). METHODS: Using volume assessment with three-dimensional CTA (3D-CTA-volume) as the gold standard, this study investigated aortic sac changes at three and 12 months after EVAR with three different ultrasound methods (2D-US anterior-posterior (AP) diameter, 3D-US AP centerline diameter, and 3D-US partial volume), and traditional CT multiplanar outer-to-outer diameter (CT-MPR OTO diameter). From august 1st, 2011 to January 2014, consecutive EVAR patients (n = 113) were available for analysis in two time intervals; 1) between preoperative and three-month follow-up and 2) between three and 12 month follow-up. RESULTS: The risk of missing true aortic sac growth (false negative finding) at three-month postoperative visit using 3D-US partial volume, 3D-US AP centerline diameter, 2D-US AP diameter, and CT-MPR OTO diameter was 19%, 21%, 22%, and 18%, respectively. Corresponding low sensitivities (0% to 21%) and kappa-values (<0.50) in detecting aortic sac changes were found. The risk of missing true growth between three and 12 months were lower (6%, 5%, 6%, and 6%, respectively), and matching sensitivities 33%, 33%, 17%, and 17%, respectively. CONCLUSIONS: All tested methods for aortic sac changes were as good as traditional CT-MPR OTO diameter and corresponded poorly with 3D-CTA-volume at three months postoperative visit but substantially better after 12 months where the residual sac change was more profound.


Asunto(s)
Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/cirugía , Aortografía , Implantación de Prótesis Vascular , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares , Imagenología Tridimensional , Ultrasonografía , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta/fisiopatología , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Valor Predictivo de las Pruebas , Factores de Tiempo , Resultado del Tratamiento
8.
Eur J Vasc Endovasc Surg ; 60(6): 933-941, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32900586

RESUMEN

OBJECTIVE: The aim of this study was to gather validity evidence for the Assessment of basic Vascular Ultrasound Expertise (AVAUSE) tool, and to establish a pass/fail score for each component, to support decisions for certification. METHODS: A cross sectional validation study performed during the European Society for Vascular Surgery's annual meeting. Validity evidence was sought for the theoretical test and two practical tests based on Messick's framework. The participants were vascular surgeons, vascular surgical trainees, sonographers, and nurses with varying experience levels. Five vascular ultrasound experts developed the theoretical and two practical test components of the AVAUSE tool for each test component. Two stations were set up for carotid examinations and two for superficial venous incompetence (SVI) examinations. Eight raters were assigned in pairs to each station. Three methods were used to set pass/fail scores: contrasting groups' method; rater consensus; and extended Angoff. RESULTS: Nineteen participants were enrolled. Acceptable internal consistency reliability (Cronbach's alpha) for the AVAUSE theoretical (0.93), carotid (0.84), and SVI (0.65) practical test were shown. In the carotid examination, inter-rater reliability (IRR) for the two rater pairs was good: 0.68 and 0.78, respectively. The carotid scores correlated significantly with years of experience (Pearson's r = 0.56, p = .013) but not with number of examinations in the last five years. For SVI, IRR was excellent at 0.81 and 0.87. SVI performance scores did not correlate with years of experience and number of examinations. The pass/fail score set by the contrasting groups' method was 29 points out of 50. The rater set pass/fail scores were 3.0 points for both carotid and SVI examinations and were used to determine successful participants. Ten of 19 participants passed the tests and were certified. CONCLUSION: Validity evidence was sought and established for the AVAUSE comprehensive tool, including pass/fail standards. AVAUSE can be used to assess competences in basic vascular ultrasound, allowing operators to progress towards independent practice.


Asunto(s)
Vasos Sanguíneos/diagnóstico por imagen , Certificación , Competencia Clínica/normas , Evaluación Educacional/métodos , Ultrasonografía , Arterias Carótidas/diagnóstico por imagen , Estudios Transversales , Europa (Continente) , Humanos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Insuficiencia Venosa/diagnóstico por imagen
9.
Ultrasound Med Biol ; 46(12): 3440-3447, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32988672

RESUMEN

Volume assessment of abdominal aortic aneurysms (AAAs) using 3-D ultrasound (US) is an innovative technique reporting good agreement with computed tomography angiography. One major limitation of the current 3-D US technique is a limited field of view, allowing full AAA acquisition in only 60% of patients. This study presents two new US acquisition protocols using magnetic field tracking, providing an "extended field of view" (XFoV-2-D and XFoV-3-D) with the aim of including both the aortic bifurcation and neck for full-volume assessment, and compares these methods with the current standard 3-D US protocol and with computed tomography angiography. A total of 20 AAA patients were included and underwent the current standard 3-D US protocol and the two novel 3-D US "extended field of view" protocols. Four patients were excluded from further analysis because of low image quality, leaving 16 patients eligible for analysis. Full AAA volume was achieved in 8 patients (50%) using the standard 3-D US protocol, in 11 patients (69%) with the XFoV-2-D protocol and in 13 patients (81%) with the XFoV-3-D protocol. In conclusion, this article describes two new and feasible US protocols applicable for full-AAA-volume estimation in most patients and should initiate further research into the added value of full volume in AAA surveillance.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Imagenología Tridimensional , Aneurisma de la Aorta Abdominal/patología , Humanos , Fenómenos Magnéticos , Tamaño de los Órganos , Ultrasonografía/métodos
10.
Eur J Vasc Endovasc Surg ; 58(3): 350-356, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31296459

RESUMEN

OBJECTIVES: Arterial access closure after endovascular aneurysm repair (EVAR) can be achieved using three different approaches: percutaneous closure devices, surgical exposure and direct suture ("cutdown"), and the less invasive fascial closure technique. The aim of this study was to report on the intra-operative, in hospital, and three month outcome of fascial closure and cutdown, and to determine risk factors for failure. METHODS: The primary outcome was assessed in 439 groins in 225 elective EVAR patients recruited consecutively and prospectively from February 1, 2011 to August 31, 2014. During the study period, fascial closure and cutdown were first and second line closing techniques. Compared with fascial closure, procedures completed with cutdown had lower BMI, thinner subcutaneous tissue of the groin and more complex femoral anatomy. Computed tomographic angiography (CTA) and duplex ultrasound (DUS) of the groin were performed pre-operatively and three months after EVAR. Retrospective review of medical records and CTA were used to determine intra-operative and in hospital outcome, and risk factors for failure. RESULTS: In total, 64%, 33%, and 3% were completed with fascial closure, cutdown, and closure device, respectively. Intra-operative, in hospital, and three month technical success rates of fascial closure vs. cutdown were 91% (283/310 groins) vs. 99% (114/115 groins), 89% (277/310 groins) vs. 99% (114/115 groins), and 89% (275/310 groins) vs. 99% (114/115 groins) (p < .001). Wound complications within three months were infrequent for both methods. No risk factor was significantly associated with failure after fascial closure. CONCLUSION: This study shows that cutdown is superior to fascial closure for femoral artery access after elective EVAR. In acute EVAR, however, fascial closure is still considered to be a good and fast method, and it has been kept in the present authors' armamentarium for this indication.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Procedimientos Quirúrgicos Electivos/métodos , Procedimientos Endovasculares/métodos , Fascia Lata/cirugía , Técnicas de Sutura , Dispositivos de Acceso Vascular , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico , Implantación de Prótesis Vascular , Angiografía por Tomografía Computarizada , Femenino , Arteria Femoral , Estudios de Seguimiento , Ingle/cirugía , Humanos , Masculino , Complicaciones Posoperatorias/prevención & control , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Doppler Dúplex
11.
Eur J Vasc Endovasc Surg ; 56(5): 673-680, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30166213

RESUMEN

OBJECTIVES: The impact of intraluminal thrombus (ILT) on abdominal aortic aneurysm (AAA) progression can be investigated non-invasively by three dimensional contrast enhanced ultrasound (3D-CEUS). The aim was to validate 3D-CEUS ILT volume and thickness measurements against computed tomography angiography (CTA), and to determine inter- and intra-operator reproducibility. METHODS: The design was for a planned comparison of 3D-CEUS and CTA and of repeated 3D-CEUS measurements in a blinded set up. Consecutive patients with asymptomatic AAA (n = 137, maximum diameter 30-55 mm) from a single centre were consecutively assessed by CTA and 3D-CEUS in a blinded setup. After exclusion of failed CTA (n = 2) and inconclusive 3D-CEUS (n = 8), 127 3D-CEUS/CTA pairs were analysed by Bland-Altman plots. 3D-CEUS inter- and intra-operator reproducibility were determined in a subgroup (n = 30) measured twice by two blinded investigators. RESULTS: In 24 of 127 (19%) patients, no ILT was found on 3D-CEUS. Intraluminal thrombus absence was confirmed by 3D-CTA analysis in all but two cases. Mean ILT volume difference between 3D-CEUS and CTA was 2.2 mL (5% of mean volume) and range of variability (ROV) amounted to ± 10.2 mL. Mean ILT thickness difference was 0.6 mm with a ROV of ± 4.6 mm 3D-CEUS inter-operator variations of ILT volume and thickness measurements were low (ROV ± 8.8 mL and ±2.9 mm, respectively). The corresponding intra-operator ROVs were ±7.5 mL and ±3.3 mm, respectively. CONCLUSIONS: 3D-CEUS demonstrated good reproducibility and a good agreement with CTA when estimating ILT volume and maximum thickness in AAA patients. It is a promising research tool to investigate potential interactions between ILT, AAA growth, and rupture.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/cirugía , Angiografía por Tomografía Computarizada , Imagenología Tridimensional , Anciano , Anciano de 80 o más Años , Aortografía/métodos , Angiografía por Tomografía Computarizada/métodos , Medios de Contraste , Femenino , Humanos , Imagenología Tridimensional/métodos , Masculino , Reproducibilidad de los Resultados
12.
Ann Vasc Surg ; 45: 287-293, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28600023

RESUMEN

Accurate imaging methods associated with minimum patient risk are important tools for clinical decision-making in vascular surgery. Today, traditional imaging methods, such as computed tomography angiography, magnetic resonance angiography, and digital subtraction angiography are the preferred modalities. Ultrasound has only challenged these methods in assessment of carotid disease, aortic aneurysms, venous insufficiency, and thromboembolism and in surveillance of in situ bypasses. These practice patterns may change with the introduction of second-generation ultrasound contrast agents which are easy to use, manageable, and safe. This topical review attempts to summarize and highlight the current evidence and future prospects for contrast-enhanced ultrasound in vascular surgery, with a particular focus on opportunities in carotid and lower limb arteriosclerotic disease and surveillance after endovascular aneurysm repair.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Medios de Contraste/administración & dosificación , Enfermedad Arterial Periférica/diagnóstico por imagen , Ultrasonografía , Procedimientos Quirúrgicos Vasculares , Aneurisma de la Aorta Abdominal/cirugía , Enfermedades de las Arterias Carótidas/cirugía , Competencia Clínica , Procedimientos Endovasculares , Humanos , Enfermedad Arterial Periférica/cirugía , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
13.
Vasc Endovascular Surg ; 50(6): 391-7, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27581227

RESUMEN

OBJECTIVES: Disruption of the endothelial lining may be one of the events linking intraluminal thrombus and abdominal aortic aneurysm growth. In the present study, we examined whether von Willebrand factor activity in plasma, contact proteins of blood coagulation, and inflammatory biomarkers may be associated with intraluminal thrombus volume in search of a biochemical marker of endothelial damage and thrombus size. DESIGN: Prospective study, correlating potential endothelial biomarkers and intraluminal thrombus volume acquired by computed tomography angiography. MATERIALS AND METHODS: Plasma was consecutively obtained from 38 patients with asymptomatic infrarenal abdominal aortic aneurysm. von Willebrand factor activity, thrombin generation time, factor XII, and prekallikrein concentration were measured in plasma on automated and in-house platforms. In total, 8 patients were excluded due to ongoing anticoagulant therapy, renal impairment, or nonappearance, thus leaving 30 patients for further analysis. All patients had computed tomography angiography, and intraluminal volume was quantified off-line by OsiriX 6.5. RESULTS: Median intraluminal thrombus volume was 42.7 mL. Spearman correlation analysis revealed a positive correlation between thrombus volume, von Willebrand factor activity (ρ = 0.56, P = .0013), and prekallikrein concentration in plasma (ρ = 0.54, P = .002). CONCLUSION: von Willebrand factor activity and concentration of prekallikrein may both be of importance regarding the evolution of thrombus in abdominal aortic aneurysm and possible biomarkers for aneurysm growth.


Asunto(s)
Aneurisma de la Aorta Abdominal/sangre , Precalicreína/análisis , Trombosis/sangre , Factor de von Willebrand/análisis , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía/métodos , Enfermedades Asintomáticas , Biomarcadores/sangre , Coagulación Sanguínea , Angiografía por Tomografía Computarizada , Femenino , Humanos , Masculino , Tomografía Computarizada Multidetector , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Tiempo de Trombina , Trombosis/diagnóstico por imagen
14.
Ugeskr Laeger ; 177(39): V03150284, 2015 Sep 21.
Artículo en Danés | MEDLINE | ID: mdl-26418640

RESUMEN

The median arcuate ligament syndrome is a rare entity and poorly described in Danish literature. The syndrome is a diagnosis of exclusion and is characterized by chronic abdominal pain, postprandial pain and weight loss. It is believed that the median arcuate ligament, being a fibrous structure of diaphragm, compresses the coeliac trunk thus causing stenosis and malperfusion of the gastrointestinal organs. Until recently, there has been some reluctance to consider intervention with revascularization or ligament release. Within the latest decade minimally invasive techniques, including laparoscopic release of the median arcuate ligament, have shown promising results.


Asunto(s)
Síndrome del Ligamento Arcuato Medio/diagnóstico , Angiografía , Humanos , Síndrome del Ligamento Arcuato Medio/diagnóstico por imagen , Síndrome del Ligamento Arcuato Medio/fisiopatología , Síndrome del Ligamento Arcuato Medio/cirugía , Ultrasonografía
15.
J Vasc Surg ; 62(1): 75-82, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26115920

RESUMEN

OBJECTIVE: Open surgery has given way to endovascular grafting in patients with aortoiliac occlusive disease. The growing use of endovascular grafts means that fewer patients with aortoiliac occlusive disease have open surgery. The declining open surgery caseload challenges the surgeon's operative skills, particularly because open surgery is increasingly used in those patients who are unsuitable for endovascular repair and hence technically more demanding. We assessed the early outcome after aortic bifurcated bypass procedures during two decades of growing endovascular activity and identified preoperative risk factors. METHODS: Data on patients with chronic limb ischemia were prospectively collected during a 20-year period (1993 to 2012). The data were obtained from the Danish Vascular Registry, assessed, and merged with data from The Danish Civil Registration System. RESULTS: We identified 3623 aortobifemoral and 144 aortobiiliac bypass procedures. The annual caseload fell from 323 to 106 during the study period, but the 30-day mortality at 3.6% (95% confidence interval [CI], 3.0-4.1) and the 30-day major complication rate remained constant at 20% (95% CI, 18-21). Gangrene (odds ratio [OR], 3.3; 95% CI, 1.7-6.5; P = .005) was the most significant risk factor for 30-day mortality, followed by renal insufficiency (OR, 2.5; 95% CI, 1.1-5.8; P = .035) and cardiac disease (OR, 2.1; 95% CI, 1.4-3.1; P < .001). Multiorgan failure, mesenteric ischemia, need for dialysis, and cardiac complications were the most lethal complications, with mortality rates of 94%, 44%, 38%, and 34%, respectively. CONCLUSIONS: Aortic bifurcated bypass is a high-risk procedure. Although open surgery has increasingly given way to endovascular repair, 30-day outcomes have remained stable during the past decade. Thus, it is still acceptable to consider an aortic bifurcated bypass whenever endovascular management is not feasible.


Asunto(s)
Enfermedades de la Aorta/cirugía , Arteriopatías Oclusivas/cirugía , Implantación de Prótesis Vascular/mortalidad , Arteria Ilíaca/cirugía , Isquemia/cirugía , Complicaciones Posoperatorias/mortalidad , Anciano , Enfermedades de la Aorta/diagnóstico , Enfermedades de la Aorta/mortalidad , Enfermedades de la Aorta/fisiopatología , Arteriopatías Oclusivas/diagnóstico , Arteriopatías Oclusivas/mortalidad , Arteriopatías Oclusivas/fisiopatología , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Enfermedad Crónica , Constricción Patológica , Dinamarca , Femenino , Humanos , Arteria Ilíaca/fisiopatología , Isquemia/diagnóstico , Isquemia/mortalidad , Isquemia/fisiopatología , Masculino , Persona de Mediana Edad , Análisis Multivariante , Oportunidad Relativa , Estudios Prospectivos , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
16.
Ugeskr Laeger ; 171(4): 235-9, 2009 Jan 19.
Artículo en Danés | MEDLINE | ID: mdl-19174039

RESUMEN

INTRODUCTION: Helicobacter pylori (HP) infection and use of nonsteroidal anti-inflammatory drugs (NSAIDs)/acetyl salicylic acid (ASA) are risk factors for bleeding peptic ulcer. HP eradication reduces the risk of rebleeding. Antibiotics, proton pump inhibitors (PPI) and presence of blood in the stomach can affect the HP test. The objectives of this study were to determine the HP prevalence and NSAID/ASA use in patients with bleeding ulcer in a low-prevalence HP area, to determine the proportion of idiopathic ulcers and to estimate the proportion of initially false negative HP tests. In addition, the objective was to describe changes in the characteristics of the patients who were admitted with ulcer bleeding during the last two decades. MATERIAL AND METHODS: Retrospective review of the records of patients who were admitted with a bleeding ulcer in 2003 to 2006 at The Department of Medical Gastroenterology S, Odense University Hospital. Patients with initially negative or missing HP tests were offered a urea breath test. This population was compared with prospective registrations for the periods 1990-1992 and 2000. RESULTS: A total of 264 patients were admitted in 2003-2006. The mean age was 72 years. The HP-prevalence was 34%, and 81% had used NSAID/ASA, as compared with 55% in 1990-1992. The proportion of idiopathic peptic ulcer disease was 6.6%. At admission, 19% and 17% of the patients were in treatment with PPI and antibiotics, respectively. Thirteen percent of the initially HP-negative patients were later found to be HP-positive. CONCLUSION: Compared to previous studies, we found a lower HP prevalence (34%) and a higher proportion of NSAID/ASA usage (81%) in 2003-2006. As we found 13% false negative HP-tests when factors that may affect the HP test were present, we advise that a retest be made where these factors are present and the initial HP test is negative.


Asunto(s)
Antiinflamatorios no Esteroideos/efectos adversos , Aspirina/efectos adversos , Infecciones por Helicobacter/complicaciones , Helicobacter pylori , Úlcera Péptica Hemorrágica/etiología , Anciano , Antibacterianos/administración & dosificación , Antiinflamatorios no Esteroideos/administración & dosificación , Aspirina/administración & dosificación , Úlcera Duodenal/inducido químicamente , Úlcera Duodenal/etiología , Úlcera Duodenal/microbiología , Femenino , Infecciones por Helicobacter/diagnóstico , Infecciones por Helicobacter/tratamiento farmacológico , Helicobacter pylori/aislamiento & purificación , Humanos , Masculino , Persona de Mediana Edad , Úlcera Péptica Hemorrágica/inducido químicamente , Úlcera Péptica Hemorrágica/microbiología , Estudios Retrospectivos , Úlcera Gástrica/inducido químicamente , Úlcera Gástrica/etiología , Úlcera Gástrica/microbiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...