Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Eur Radiol ; 33(6): 4270-4279, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36625882

RESUMEN

OBJECTIVES: To develop and test a Retina U-Net algorithm for the detection of primary lung tumors and associated metastases of all stages on FDG-PET/CT. METHODS: A data set consisting of 364 FDG-PET/CTs of patients with histologically confirmed lung cancer was used for algorithm development and internal testing. The data set comprised tumors of all stages. All lung tumors (T), lymphatic metastases (N), and distant metastases (M) were manually segmented as 3D volumes using whole-body PET/CT series. The data set was split into a training (n = 216), validation (n = 74), and internal test data set (n = 74). Detection performance for all lesion types at multiple classifier thresholds was evaluated and false-positive-findings-per-case (FP/c) calculated. Next, detected lesions were assigned to categories T, N, or M using an automated anatomical region segmentation. Furthermore, reasons for FPs were visually assessed and analyzed. Finally, performance was tested on 20 PET/CTs from another institution. RESULTS: Sensitivity for T lesions was 86.2% (95% CI: 77.2-92.7) at a FP/c of 2.0 on the internal test set. The anatomical correlate to most FPs was the physiological activity of bone marrow (16.8%). TNM categorization based on the anatomical region approach was correct in 94.3% of lesions. Performance on the external test set confirmed the good performance of the algorithm (overall detection rate = 88.8% (95% CI: 82.5-93.5%) and FP/c = 2.7). CONCLUSIONS: Retina U-Nets are a valuable tool for tumor detection tasks on PET/CT and can form the backbone of reading assistance tools in this field. FPs have anatomical correlates that can lead the way to further algorithm improvements. The code is publicly available. KEY POINTS: • Detection of malignant lesions in PET/CT with Retina U-Net is feasible. • All false-positive findings had anatomical correlates, physiological bone marrow activity being the most prevalent. • Retina U-Nets can build the backbone for tools assisting imaging professionals in lung tumor staging.


Asunto(s)
Neoplasias Pulmonares , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Fluorodesoxiglucosa F18 , Tomografía de Emisión de Positrones , Neoplasias Pulmonares/diagnóstico por imagen , Radiofármacos , Sensibilidad y Especificidad
2.
J Cardiovasc Magn Reson ; 20(1): 57, 2018 08 16.
Artículo en Inglés | MEDLINE | ID: mdl-30111368

RESUMEN

These "Guidelines for training in Cardiovascular Magnetic Resonance" were developed by the Certification Committee of the Society for Cardiovascular Magnetic Resonance (SCMR) and approved by the SCMR Board of Trustees.


Asunto(s)
Cardiología/educación , Certificación/métodos , Educación de Postgrado en Medicina/métodos , Internado y Residencia , Imagen por Resonancia Magnética , Cardiología/normas , Certificación/normas , Competencia Clínica , Curriculum , Educación de Postgrado en Medicina/normas , Humanos , Internado y Residencia/normas
3.
Mol Imaging Biol ; 17(5): 595-608, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26286794

RESUMEN

This paper summarises key themes and discussions from the 4th international workshop dedicated to the advancement of the technical, scientific and clinical applications of combined positron emission tomography (PET)/magnetic resonance imaging (MRI) systems that was held in Tübingen, Germany, from February 23 to 27, 2015. Specifically, we summarise the three days of invited presentations from active researchers in this and associated fields augmented by round table discussions and dialogue boards with specific topics. These include the use of PET/MRI in cardiovascular disease, paediatrics, oncology, neurology and multi-parametric imaging, the latter of which was suggested as a key promoting factor for the wider adoption of integrated PET/MRI. Discussions throughout the workshop and a poll taken on the final day demonstrated that attendees felt more strongly that PET/MRI has further advanced in both technical versatility and acceptance by clinical and research-driven users from the status quo of last year. Still, with only minimal evidence of progress made in exploiting the true complementary nature of the PET and MRI-based information, PET/MRI is still yet to achieve its potential. In that regard, the conclusion of last year's meeting "the real work has just started" still holds true.


Asunto(s)
Imagen por Resonancia Magnética , Imagen Multimodal , Tomografía de Emisión de Positrones , Alemania , Humanos
4.
Magn Reson Med ; 74(2): 365-71, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25113911

RESUMEN

PURPOSE: To develop a novel sequence for simultaneous quantification of T1 and T2 relaxation times in the myocardium based on the transient phase of the balanced steady-state free precession. METHODS: A new prototype sequence, named "cardiac balanced-SSFP inversion recovery with interleaved sampling acquisition" (CABIRIA) was developed based on a single-shot bSSFP readout following an inversion pulse. With this method, T1 and T2 values can be calculated from the analysis of signal evolution. The scan duration for a single slice in vivo was 8 heartbeats, thus feasible in a breath-hold. The sequence was validated both in vitro by comparing it to conventional inversion recovery and multi-echo spin-echo methods and in 5 healthy volunteers by comparing it to the Modified Look-Locker Inversion Recovery (MOLLI) sequence and to a T2 quantification sequence based on multi-T2 -prepared bSSFP. RESULTS: The method showed good agreement with conventional methods for both T1 and T2 measurements (concordance correlation coefficient ≥ 0.99) in vitro. In healthy volunteers the measured T1 values were 1227 ± 68 ms and T2 values 37.9 ± 2.4 ms, with similar inter- and intrasubject variability with respect to existing methods. CONCLUSION: The proposed CABIRIA method enables simultaneous quantification of myocardial T1 and T2 values with good accuracy and precision.


Asunto(s)
Artefactos , Ventrículos Cardíacos/anatomía & histología , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Procesamiento de Señales Asistido por Computador , Algoritmos , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Valores de Referencia , Reproducibilidad de los Resultados , Mecánica Respiratoria , Sensibilidad y Especificidad
6.
Respiration ; 87(3): 254-64, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24458197

RESUMEN

The discussion about setting up a program for lung cancer screening was launched with the publication of the results of the National Lung Screening Trial, which suggested reduced mortality in high-risk subjects undergoing CT screening. However, important questions about the benefit-harm balance and the details of a screening program and its cost-effectiveness remain unanswered. A panel of specialists in chest radiology, respiratory medicine, epidemiology, and thoracic surgery representing all Swiss university hospitals prepared this joint statement following several meetings. The panel argues that premature and uncontrolled introduction of a lung cancer screening program may cause substantial harm that may remain undetected without rigorous quality control. This position paper focuses on the requirements of running such a program with the objective of harmonizing efforts across the involved specialties and institutions and defining quality standards. The underlying statement includes information on current evidence for a reduction in mortality with lung cancer screening and the potential epidemiologic implications of such a program in Switzerland. Furthermore, requirements for lung cancer screening centers are defined, and recommendations for both the CT technique and the algorithm for lung nodule assessment are provided. In addition, related issues such as patient management, registry, and funding are addressed. Based on the current state of the knowledge, the panel concludes that lung cancer screening in Switzerland should be undertaken exclusively within a national observational study in order to provide answers to several critical questions before considering broad population-based screening for lung cancer.


Asunto(s)
Detección Precoz del Cáncer/normas , Neoplasias Pulmonares/diagnóstico por imagen , Hospitales Universitarios , Humanos , Tamizaje Masivo , Guías de Práctica Clínica como Asunto , Medición de Riesgo , Suiza , Tomografía Computarizada por Rayos X
7.
Int J Cardiovasc Imaging ; 30(2): 323-8, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24221905

RESUMEN

To test feasibility of myocardial T1 mapping of the right ventricle (RV) at systole when myocardium is more compact and to determine the most appropriate imaging plane. 20 healthy volunteers (11 men; 33 ± 8 years) were imaged on a 1.5T scanner (MAGNETOM Avanto, Siemens AG, Erlangen, Germany). A modified look-locker inversion-recovery sequence was acquired at mid-ventricular short axis (SAX), as horizontal long-axis view and as transversal view at systole (mean trigger time 363 ± 37 ms). Myocardial T1 time of the left-ventricular and RV myocardium was measured within a region of interest (ROI) on generated T1-maps. The most appropriate imaging plane for the RV was determined by the ability to draw a ROI including the largest amount of myocardium without including adjacent tissue or blood. At systole, when myocardium is thicker, measurements of the RV myocardium were feasible in 18/20 subjects. Average size of the ROI was 0.42 ± 0.28 cm(2). In 10/18 subjects, short axis was the most appropriate imaging plane to obtain measurements (p = 0.034). Average T1 time of the RV myocardium was 1,016 ± 61 ms, and average T1 of the left-ventricular (LV) was 956 ± 25 ms (p < 0.001). T1 mapping of the RV myocardium is feasible during systole in the majority of healthy subjects but with a small ROI only. SAX plane was the optimal imaging plane in the majority of subjects. Native myocardial T1 time of the RV is significantly longer compared to the LV, which might be explained by the naturally higher collagen content of the RV.


Asunto(s)
Ventrículos Cardíacos/anatomía & histología , Imagen por Resonancia Cinemagnética , Miocardio , Adulto , Colágeno/análisis , Estudios de Factibilidad , Femenino , Voluntarios Sanos , Ventrículos Cardíacos/química , Humanos , Masculino , Persona de Mediana Edad , Miocardio/química , Valor Predictivo de las Pruebas , Valores de Referencia , Sístole , Función Ventricular Derecha , Adulto Joven
8.
Acta Radiol ; 54(7): 778-84, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23761544

RESUMEN

BACKGROUND: The principal concern of any radiation exposure in computed tomography (CT) is the induction of stochastic risks of developing a radiation-induced cancer. The results given in this manuscript will allow to (re-)calculate yield of chest CT. PURPOSE: To demonstrate a method to evaluate the lifetime attributable risk (LAR) of cancer incidence/mortality due to a single diagnostic investigation in a 1-year cohort of consecutive chest CT for suspected pulmonary embolism (PE). MATERIAL AND METHODS: A 1-year cohort of consecutive chest CT for suspected PE using a standard scan protocol was analyzed retrospectively (691 patients, 352 men, 339 women). Normalized patient-specific estimations of the radiation doses received by individual organs were correlated with age- and sex-specific mean predicted cancer incidence and age- and sex-specific predicted cancer mortality based on the BEIR VII results. Additional correlation was provided for natural occurring risks. RESULTS: LAR of cancer incidence/mortality following one chest CT was calculated for cancer of the stomach, colon, liver, lung, breast, uterus, ovaries, bladder, thyroid, and for leukemia. LAR remains very low for all age and sex categories, being highest for cancer of the lungs and breasts in 20-year-old women (0.61% and 0.4%, respectively). Summation of all cancer sites analyzed raised the cumulative relative LAR up to 2.76% in 20-year-old women. CONCLUSION: Using the method presented in this work, LAR of cancer incidence and cancer mortality for a single chest CT for PE seems very low for all age groups and both sexes, but being highest for young patients. Hence the risk for radiation-induced organ cancers must be outweighed with the potential benefit or a treatment and the potential risks of a missed and therefore untreated PE.


Asunto(s)
Neoplasias Inducidas por Radiación/epidemiología , Embolia Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X/efectos adversos , Anciano , Femenino , Humanos , Incidencia , Masculino , Neoplasias Inducidas por Radiación/mortalidad , Dosis de Radiación , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo
9.
Infection ; 40(6): 677-84, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22802096

RESUMEN

BACKGROUND: The clinical characteristics of human metapneumovirus (hMPV)-associated lower respiratory tract infection (LRTI) after allogeneic hematopoietic stem cell transplantation (HSCT) is not well described. We describe the clinical course in eight HSCT recipients suffering from hMPV infection. METHODS: We prospectively included all patients with hMPV-associated LRTI after allogeneic HSCT during a period of 1 year. hMPV was diagnosed by multiplex polymerase chain reaction (PCR) from bronchoalveolar lavage (BAL). RESULTS: Eight patients with hMPV-associated LRTI were identified from 93 BAL samples. Three of the eight patients had co-infections with other pathogens. The median age of the patients was 45 years [interquartile range (IQR) 36.8-53.5], the median time posttransplant was 473 days (IQR 251-1,165), 5/8 patients had chronic graft-versus-host disease (cGvHD), and 6/8 patients received immunosuppression. Chest computed tomography (CT) scanning showed a ground-glass pattern in 7/8 patients. Seven of eight patients required hospitalization due to severe symptoms and hypoxemia. All were treated with intravenous immunoglobulin (IVIG), which was combined with oral ribavirin in six patients. The mortality rate was 12.5 % (1/8). CONCLUSIONS: hMPV-associated LRTI in allogeneic HSCT recipients are not uncommon and present with unspecific respiratory symptoms, ground-glass pattern in CT scanning, and co-infection.


Asunto(s)
Trasplante de Células Madre Hematopoyéticas/efectos adversos , Metapneumovirus/aislamiento & purificación , Infecciones por Paramyxoviridae/etiología , Infecciones del Sistema Respiratorio/etiología , Adulto , Antivirales/uso terapéutico , Quimioterapia Combinada , Femenino , Humanos , Huésped Inmunocomprometido , Inmunoglobulinas Intravenosas/uso terapéutico , Masculino , Persona de Mediana Edad , Infecciones por Paramyxoviridae/diagnóstico , Infecciones por Paramyxoviridae/tratamiento farmacológico , Infecciones del Sistema Respiratorio/diagnóstico , Infecciones del Sistema Respiratorio/tratamiento farmacológico , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Ribavirina/uso terapéutico , Tomografía Computarizada por Rayos X , Trasplante Homólogo
10.
Magn Reson Med ; 66(6): 1666-73, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21523822

RESUMEN

A novel technique to guide a subjects' breathing pattern using a respiratory biofeedback (rBF) "game" to improve respiratory efficiency is presented. The continuously adaptive windowing strategy, a fully automatic and highly efficient free-breathing navigator gated technique, is used to acquire the data as it ensures that all potential navigator acceptance windows are possible. This enables the rBF to be fully adaptable to a subject's respiratory pattern. Images of the thoracic aorta acquired using balanced steady-state free precession with continuously adaptive windowing strategy respiratory motion control, with and without rBF, were compared in 10 healthy subjects. Total scan time was reduced by using rBF. The mean scan time was reduced from 7 min 44 s (463 cardiac cycles, ± 127 cc) without rBF to 5 min 43 s (380 cardiac cycles, ± 118 cc) with the use of rBF (P < 0.05). Respiratory efficiency was increased from 45% without rBF to 56% with rBF (P < 0.01). Image quality was the same for both techniques (P = ns). In conclusion, rBF significantly improved respiratory efficiency and reduced acquisition duration without affecting image quality.


Asunto(s)
Aorta Torácica/anatomía & histología , Artefactos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Mecánica Respiratoria , Técnicas de Imagen Sincronizada Respiratorias/métodos , Adulto , Algoritmos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
11.
Praxis (Bern 1994) ; 99(1): 55-9, 2010 Jan 06.
Artículo en Alemán | MEDLINE | ID: mdl-20052640

RESUMEN

We report the case of a 83-year-old female patient with ST elevation myocardial infarction who developed a rectus sheath hematoma during treatment with antiplatelet medication and systemic anticoagulants following cough attacks. The patient presented with progressive pain in the left lower abdomen associated with a palpable mass and anaemia. Abdominal sonography and computed tomography revealed a rectus sheath hematoma. We discuss pathogenesis, clinical findings, diagnostic workup and therapy. Moreover, we review the current related literature.


Asunto(s)
Abdomen Agudo/etiología , Anticoagulantes/efectos adversos , Fibrilación Atrial/tratamiento farmacológico , Tos/complicaciones , Hematoma/inducido químicamente , Embolia Intracraneal/tratamiento farmacológico , Anciano de 80 o más Años , Anticoagulantes/uso terapéutico , Aspirina/efectos adversos , Aspirina/uso terapéutico , Clopidogrel , Seudoobstrucción Colónica/diagnóstico , Comorbilidad , Dalteparina/efectos adversos , Dalteparina/uso terapéutico , Diagnóstico Diferencial , Relación Dosis-Respuesta a Droga , Quimioterapia Combinada , Femenino , Hematoma/diagnóstico , Humanos , Fenprocumón/efectos adversos , Fenprocumón/uso terapéutico , Recto del Abdomen , Ticlopidina/efectos adversos , Ticlopidina/análogos & derivados , Ticlopidina/uso terapéutico
12.
AJNR Am J Neuroradiol ; 31(3): 527-35, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19892813

RESUMEN

BACKGROUND AND PURPOSE: MR including MRV is an established method to diagnose CVT. However, it remains unsettled which MR imaging modalities offer the highest diagnostic accuracy. We evaluated the accuracy of a combined, dynamic (1.5 seconds per dataset) and static (voxel size, 1.1 x 0.9 x 1.5 mm), contrast-enhanced MRV method (combo-4D MRV) relative to other established MR/MRV modalities. MATERIALS AND METHODS: A total of 39 patients with CVT (n = 20) and control subjects (n = 19) underwent combo-4D MRV, 2D TOF MRV, GRE imaging, and T2W imaging. For these modalities, diagnostic accuracy (ROCs) for CVT affecting 53 out of 234 predefined venous segments was determined. Sensitivity and specificity were separately calculated for different stages of CVT (acute/subacute/chronic). RESULTS: Combo-4D MRV showed the highest accuracy (AUC, 0.99 [95% CI, 0.97-1.0]; sensitivity, 97% [84%-100%]) for thrombosed dural sinuses. For all thrombosed segments including cortical veins, its sensitivity was best (76% [64%-84%]; AUC, 0.92 [0.88-0.96]), followed by TOF MRV (72% [59%-81%]; AUC, 0.93 [0.88-0.97]). Even for chronic CVT, it showed a relatively high sensitivity of 67% (30%-90%). For thrombosed cortical veins alone, GRE images achieved the highest sensitivity (66% [46%-81%]; AUC, 0.88 [0.78-0.97]). Specificities of all modalities ranged from 96% to 99%. CONCLUSIONS: Combo-4D MRV showed an excellent accuracy for the diagnosis of dural sinus thrombosis. The analysis of dynamic patterns of contrast enhancement in dural sinuses appeared useful to identify chronic thrombosis. To diagnose thrombosed cortical veins, GRE images should primarily be analyzed.


Asunto(s)
Tomografía Computarizada Cuatridimensional/métodos , Tomografía Computarizada Cuatridimensional/normas , Trombosis Intracraneal/diagnóstico por imagen , Flebografía/métodos , Flebografía/normas , Trombosis de la Vena/diagnóstico por imagen , Adulto , Anciano , Venas Cerebrales/diagnóstico por imagen , Medios de Contraste/uso terapéutico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
14.
Eur Radiol ; 18(12): 2879-84, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18654785

RESUMEN

Isolation of the pulmonary veins has emerged as a new therapy for atrial fibrillation. Pre-procedural magnetic resonance (MR) imaging enhances safety and efficacy; moreover, it reduces radiation exposure of the patients and interventional team. The purpose of this study was to optimize the MR protocol with respect to image quality and acquisition time. In 31 patients (23-73 years), the anatomy of the pulmonary veins, left atrium and oesophagus was assessed on a 1.5-Tesla scanner with four different sequences: (1) ungated two-dimensional true fast imaging with steady precession (2D-TrueFISP), (2) ECG/breath-gated 3D-TrueFISP, (3) ungated breath-held contrast-enhanced three-dimensional turbo fast low-angle shot (CE-3D-tFLASH), and (4) ECG/breath-gated CE-3D-TrueFISP. Image quality was scored from 1 (structure not visible) to 5 (excellent visibility), and the acquisition time was monitored. The pulmonary veins and left atrium were best visualized with CE-3D-tFLASH (scores 4.50 +/- 0.52 and 4.59 +/- 0.43) and ECG/breath-gated CE-3D-TrueFISP (4.47 +/- 0.49 and 4.63 +/- 0.39). Conspicuity of the oesophagus was optimal with CE-3D-TrueFISP and 2D-TrueFISP (4.59 +/- 0.35 and 4.19 +/- 0.46) but poor with CE-3D-tFLASH (1.03 +/- 0.13) (p < 0.05). Acquisition times were shorter for 2D-TrueFISP (44 +/- 1 s) and CE-3D-tFLASH (345 +/- 113 s) compared with ECG/breath-gated 3D-TrueFISP (634 +/- 197 s) and ECG/breath-gated CE-3D-TrueFISP (636 +/- 230 s) (p < 0.05). In conclusion, an MR imaging protocol comprising CE-3D-tFLASH and 2D-TrueFISP allows assessment of the pulmonary veins, left atrium and oesophagus in less than 7 min and can be recommended for pre-procedural imaging before electric isolation of pulmonary veins.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Ablación por Catéter/métodos , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Venas Pulmonares/patología , Venas Pulmonares/cirugía , Mecánica Respiratoria , Cirugía Asistida por Computador/métodos , Adulto , Anciano , Artefactos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Control de Calidad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento , Adulto Joven
17.
Eur Radiol ; 18(10): 2265-73, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18431575

RESUMEN

Total-body contrast-enhanced MRA (CE-MRA) provides information of the entire vascular system according to a one-stop-shop approach. Short, wide-bore scanners have not yet been used for total-body CE-MRA, probably due to their restricted field of view in the z-direction. The purpose of this feasibility study is to introduce an image protocol for total-body MRA on a short, wide-bore system. The protocol includes five to six table-moving steps and two injection runs. Two pharmacologically different contrast materials (CM) were applied in ten healthy volunteers in view of possible CM-dependent influences on the protocol outcome (Gd-Bopta, Gd-Dota). Differences consisted of significantly higher CNR with Gd-Bopta with a mean of 73.8+/-38.7 versus 69.1+/-34.3 (p=0.008), significantly better arterial visualization values with Gd-Dota with a mean of 1.26+/-0.44 versus 1.53+/-0.73 (p=0.003) and a tendency to less venous overlay with Gd-Dota, mean 1.19+/-0.44 and 1.34+/-0.72, respectively (p=0.065) (two-tailed Wilcoxon matched-pairs test). Overall 94% of the steps were valued as qualitatively excellent or good. The good results with both CM suggest a transfer to further patient evaluation.


Asunto(s)
Arterias/anatomía & histología , Compuestos Heterocíclicos , Angiografía por Resonancia Magnética/instrumentación , Angiografía por Resonancia Magnética/métodos , Meglumina/análogos & derivados , Compuestos Organometálicos , Imagen de Cuerpo Entero/métodos , Adulto , Medios de Contraste , Diseño de Equipo , Análisis de Falla de Equipo , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
18.
Internist (Berl) ; 49(4): 490, 492-4, 2008 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-18320154

RESUMEN

We present the case of a 63 year-old male Swiss patient with chronic diarrhea, mucous anal discharge, anal fistula, chronic anal ulceration and history of tuberculosis 56 years ago. Imaging and endoscopy was highly suspicious for Crohn's Disease, but histology and culture for M. tuberculosis proved tuberculous proctitis with perianal involvement and fistulation. The consideration of extrapulmonal tuberculosis with its various manifestations is crucial for the investigation of chronic abdominal complaints in order to avoid serious consequences of tuberculosis treated with immunosuppressive therapy.


Asunto(s)
Proctitis/diagnóstico , Fístula Rectal/etiología , Tuberculosis Gastrointestinal/diagnóstico , Antituberculosos/efectos adversos , Antituberculosos/uso terapéutico , Biopsia , Quimioterapia Combinada , Endosonografía , Humanos , Masculino , Persona de Mediana Edad , Proctitis/tratamiento farmacológico , Proctitis/patología , Fístula Rectal/diagnóstico , Fístula Rectal/tratamiento farmacológico , Fístula Rectal/patología , Recto/patología , Tomografía Computarizada por Rayos X , Tuberculosis Gastrointestinal/tratamiento farmacológico , Tuberculosis Gastrointestinal/patología
19.
Dtsch Med Wochenschr ; 130(21): 1311-3, 2005 May 27.
Artículo en Alemán | MEDLINE | ID: mdl-15902618

RESUMEN

HISTORY AND CLINICAL FINDINGS: A 20-year-old patient was hospitalized with persistent high fever after tonsillitis and swelling of the talocalcanean joint. INVESTIGATIONS: The ECG showed a partial right bundle branch block pattern and pathological T inversions on the left precordial leads. Cardiac Troponin I levels were slightly elevated and echocardiography revealed a dyscinetic area at the right ventricular apex. The anti-streptolysin titer was elevated. DIAGNOSIS: Post-streptococcal rheumatic myocarditis. THERAPY AND FOLLOW-UP: Antibiotic therapy for 2 weeks. The patient showed subjective full recovery after 6 weeks. The anti-streptolysin titer further increases. Nuclear spin tomography of the heart reveal postinflammatory alterations at the apex of the right ventricle. CONCLUSION: Rheumatoid fever is a rare diagnosis in developed countries. This case, however, illustrates that the true prevalence of rheumatoid carditis might be underestimated in the presence of only minimal heart-and joint-specific symptoms.


Asunto(s)
Miocarditis/etiología , Cardiopatía Reumática/etiología , Tonsilitis/complicaciones , Adulto , Combinación Amoxicilina-Clavulanato de Potasio/uso terapéutico , Antibacterianos/uso terapéutico , Antiinflamatorios no Esteroideos/uso terapéutico , Antiestreptolisina/análisis , Artritis Infecciosa/complicaciones , Artritis Infecciosa/microbiología , Quimioterapia Combinada/uso terapéutico , Ecocardiografía , Electrocardiografía , Humanos , Imagen por Resonancia Magnética , Masculino , Miocarditis/diagnóstico , Miocarditis/tratamiento farmacológico , Cardiopatía Reumática/diagnóstico , Cardiopatía Reumática/tratamiento farmacológico , Articulación Talocalcánea , Tonsilitis/microbiología , Troponina I/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...