1.
Radiat Environ Biophys ; 63(1): 165-179, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38413426

RESUMEN

The EIVIC project was launched in 2020, and the main goal was the organisation of a European intercomparison of in-vivo monitoring laboratories dealing with direct measurements of gamma-emitting radionuclides incorporated into the body of exposed workers. This project was organised jointly by members of EURADOS Working Group 7 on internal dosimetry (WG7), the Federal Office for Radiation Protection (BfS, Germany) and the Radioprotection and Nuclear Safety Institute (IRSN, France). The objective was to assess the implementation of individual-monitoring requirements in EU Member States on the basis of in-vivo measurements and to gain insight into the performance of in-vivo measurements using whole-body counters. In this context, a total of 41 in-vivo monitoring laboratories from 21 countries, together with JRC (EC) and IAEA participated. The results were submitted in terms of activity (Bq) of the radionuclides identified inside phantoms that were circulated to all participants. The measured data were compared with reference activity values to evaluate the corresponding bias according to the standards ISO 28218 and ISO 13528. In general, the results of the different exercises are good, and most facilities are in conformity with the criteria for the bias and z-scores in the ISO standards. Furthermore, information about technical and organisational characteristics of the participating laboratories was collected to test if they had a significant influence on the reported results.


Asunto(s)
Laboratorios , Monitoreo de Radiación , Humanos , Radiometría/métodos , Radioisótopos , Francia , Estándares de Referencia
2.
Radiat Prot Dosimetry ; 194(1): 42-56, 2021 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-33989429

RESUMEN

Since 2012, the European Radiation Dosimetry Group (EURADOS) has developed its Strategic Research Agenda (SRA), which contributes to the identification of future research needs in radiation dosimetry in Europe. Continued scientific developments in this field necessitate regular updates and, consequently, this paper summarises the latest revision of the SRA, with input regarding the state of the art and vision for the future contributed by EURADOS Working Groups and through a stakeholder workshop. Five visions define key issues in dosimetry research that are considered important over at least the next decade. They include scientific objectives and developments in (i) updated fundamental dose concepts and quantities, (ii) improved radiation risk estimates deduced from epidemiological cohorts, (iii) efficient dose assessment for radiological emergencies, (iv) integrated personalised dosimetry in medical applications and (v) improved radiation protection of workers and the public. This SRA will be used as a guideline for future activities of EURADOS Working Groups but can also be used as guidance for research in radiation dosimetry by the wider community. It will also be used as input for a general European research roadmap for radiation protection, following similar previous contributions to the European Joint Programme for the Integration of Radiation Protection Research, under the Horizon 2020 programme (CONCERT). The full version of the SRA is available as a EURADOS report (www.eurados.org).


Asunto(s)
Monitoreo de Radiación , Protección Radiológica , Europa (Continente) , Humanos , Dosis de Radiación , Radiación Ionizante , Radiometría
3.
J Radiol Prot ; 39(4): R37-R50, 2019 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-31307030

RESUMEN

This paper provides a summary of the Education and Training (E&T) activities that have been developed and organised by the European Radiation Dosimetry Group (EURADOS) in recent years and in the case of Training Courses over the last decade. These E&T actions include short duration Training Courses on well-established topics organised within the activity of EURADOS Working Groups (WGs), or one-day events integrated in the EURADOS Annual Meeting (workshops, winter schools, the intercomparison participants' sessions and the learning network, among others). Moreover, EURADOS has recently established a Young Scientist Grant and a Young Scientist Award. The Grant supports young scientists by encouraging them to perform research projects at other laboratories of the EURADOS network. The Award is given in recognition of excellent work developed within the WGs' work programme. Additionally, EURADOS supports the dissemination of knowledge in radiation dosimetry by promoting and endorsing conferences such as the individual monitoring (IM) series, the neutron and ion dosimetry symposia (NEUDOS) and contributions to E&T sessions at specific events.

4.
Ann ICRP ; 47(3-4): 75-82, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29664321

RESUMEN

European Radiation Dosimetry Group (EURADOS) Working Group 7 is a network on internal dosimetry that brings together researchers from more than 60 institutions in 21 countries. The work of the group is organised into task groups that focus on different aspects, such as development and implementation of biokinetic models (e.g. for diethylenetriamine penta-acetic acid decorporation therapy), individual monitoring and the dose assessment process, Monte Carlo simulations for internal dosimetry, uncertainties in internal dosimetry, and internal microdosimetry. Several intercomparison exercises and training courses have been organised. The IDEAS guidelines, which describe - based on the International Commission on Radiological Protection's (ICRP) biokinetic models and dose coefficients - a structured approach to the assessment of internal doses from monitoring data, are maintained and updated by the group. In addition, Technical Recommendations for Monitoring Individuals for Occupational Intakes of Radionuclides have been elaborated on behalf of the European Commission, DG-ENER (TECHREC Project, 2014-2016, coordinated by EURADOS). Quality assurance of the ICRP biokinetic models by calculation of retention and excretion functions for different scenarios has been performed and feedback was provided to ICRP. An uncertainty study of the recent caesium biokinetic model quantified the overall uncertainties, and identified the sensitive parameters of the model. A report with guidance on the application of ICRP biokinetic models and dose coefficients is being drafted at present. These and other examples of the group's activities, which complement the work of ICRP, are presented.


Asunto(s)
Protección Radiológica/normas , Radiometría/normas , Humanos , Agencias Internacionales , Exposición Profesional/prevención & control , Monitoreo de Radiación/normas
5.
Radiat Prot Dosimetry ; 170(1-4): 446-50, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27103642

RESUMEN

Monte Carlo (MC) methods are numerical simulation techniques that can be used to extend the scope of calibrations performed in in vivo monitoring laboratories. These methods allow calibrations to be carried out for a much wider range of body shapes and sizes than would be feasible using physical phantoms. Unfortunately, nowadays, this powerful technique is still used mainly in research institutions only. In 2013, EURADOS and the in vivo monitoring laboratory of Karlsruhe Institute of Technology (KIT) organized a 3-d training course to disseminate knowledge on the application of MC methods for in vivo monitoring. It was intended as a hands-on course centered around an exercise which guided the participants step by step through the calibration process using a simplified version of KIT's equipment. Only introductory lectures on in vivo monitoring and voxel models were given. The course was based on MC codes of the MCNP family, widespread in the community. The strong involvement of the participants and the working atmosphere in the classroom as well as the formal evaluation of the course showed that the approach chosen was appropriate. Participants liked the hands-on approach and the extensive course materials on the exercise.


Asunto(s)
Monitoreo de Radiación/instrumentación , Monitoreo de Radiación/métodos , Recuento Corporal Total/instrumentación , Calibración , Radioisótopos de Cesio , Simulación por Computador , Alemania , Humanos , Capacitación en Servicio , Cooperación Internacional , Radioisótopos de Yodo , Pulmón/efectos de la radiación , Método de Montecarlo , Fantasmas de Imagen , Radioisótopos de Potasio , Monitoreo de Radiación/normas , Recuento Corporal Total/métodos , Recuento Corporal Total/normas
6.
Radiat Prot Dosimetry ; 170(1-4): 221-4, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26396263

RESUMEN

Current calibration methods for body counting offer personalisation for lung counting predominantly with respect to ratios of body mass and height. Chest wall thickness is used as an intermediate parameter. This work revises and extends these methods using a series of computational phantoms derived from medical imaging data in combination with radiation transport simulation and statistical analysis. As an example, the method is applied to the calibration of the In Vivo Measurement Laboratory (IVM) at Karlsruhe Institute of Technology (KIT) comprising four high-purity germanium detectors in two partial body measurement set-ups. The Monte Carlo N-Particle (MCNP) transport code and the Extended Cardiac-Torso (XCAT) phantom series have been used. Analysis of the computed sample data consisting of 18 anthropometric parameters and calibration factors generated from 26 photon sources for each of the 30 phantoms reveals the significance of those parameters required for producing an accurate estimate of the calibration function. Body circumferences related to the source location perform best in the example, while parameters related to body mass show comparable but lower performances, and those related to body height and other lengths exhibit low performances. In conclusion, it is possible to give more accurate estimates of calibration factors using this proposed approach including estimates of uncertainties related to interindividual anatomical variation of the target population.


Asunto(s)
Antropometría , Fantasmas de Imagen , Radiometría/instrumentación , Tórax/efectos de la radiación , Adulto , Calibración , Simulación por Computador , Femenino , Germanio/química , Alemania , Humanos , Laboratorios , Pulmón/efectos de la radiación , Masculino , Método de Montecarlo , Fotones , Radiometría/métodos , Reproducibilidad de los Resultados , Pared Torácica/efectos de la radiación , Recuento Corporal Total
7.
Radiat Prot Dosimetry ; 170(1-4): 8-12, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26464525

RESUMEN

The TECHREC project, funded by the European Commission, will provide Technical Recommendations for Monitoring Individuals for Occupational Intakes of Radionuclides It is expected that the document will be published by the European Commission as a report in its Radiation Protection Series during 2016. The project is coordinated by the European Radiation Dosimetry Group (EURADOS) and is being carried out by members of EURADOS Working Group 7 (Internal Dosimetry). This paper describes the aims and purpose of the Technical Recommendations, and explains how the project is organised.


Asunto(s)
Exposición Profesional/análisis , Monitoreo de Radiación/normas , Protección Radiológica/métodos , Radioisótopos/análisis , Europa (Continente) , Humanos , Cooperación Internacional , Control de Calidad , Dosis de Radiación , Monitoreo de Radiación/métodos , Protección Radiológica/instrumentación
8.
Radiat Prot Dosimetry ; 170(1-4): 402-6, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26705360

RESUMEN

European Radiation Dosimetry Group e.V. (EURADOS) survey on individual monitoring data and dose assessment has been carried out for 550 foreigners returning home after being exposed in Japan to intakes of radionuclides (mainly (131)I, (132)I, (132)Te, (134)Cs and (137)Cs) as a consequence of the Fukushima Daiichi NPP accident. In vivo and in vitro measurements were performed in their respective countries at an early stage after that accident. Intakes of radionuclides were detected in 208 persons from Europe and Canada, but the committed effective dose E(50) was below the annual dose limit for the public (<1 mSv) in all the cases. Lessons learned from this EURADOS survey are presented here regarding not only internal dosimetry issues, but also the management of the emergency situation, the perception of the risk of health effects due to radiation and the communication with exposed persons who showed anxiety and lack of trust in monitoring data and dose assessments.


Asunto(s)
Radioisótopos de Cesio/análisis , Exposición a Riesgos Ambientales/análisis , Accidente Nuclear de Fukushima , Radioisótopos de Yodo/análisis , Monitoreo de Radiación/métodos , Canadá , Urgencias Médicas , Exposición a Riesgos Ambientales/prevención & control , Europa (Continente) , Humanos , Japón , Cinética , Plantas de Energía Nuclear , Dosis de Radiación , Protección Radiológica/métodos , Radiometría , Medición de Riesgo , Factores de Tiempo , Viaje , Tsunamis
9.
Radiat Prot Dosimetry ; 163(1): 37-57, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24743755

RESUMEN

Parameter uncertainties for the biokinetic model of caesium (Cs) developed by Leggett et al. were inventoried and evaluated. The methods of parameter uncertainty analysis were used to assess the uncertainties of model predictions with the assumptions of model parameter uncertainties and distributions. Furthermore, the importance of individual model parameters was assessed by means of sensitivity analysis. The calculated uncertainties of model predictions were compared with human data of Cs measured in blood and in the whole body. It was found that propagating the derived uncertainties in model parameter values reproduced the range of bioassay data observed in human subjects at different times after intake. The maximum ranges, expressed as uncertainty factors (UFs) (defined as a square root of ratio between 97.5th and 2.5th percentiles) of blood clearance, whole-body retention and urinary excretion of Cs predicted at earlier time after intake were, respectively: 1.5, 1.0 and 2.5 at the first day; 1.8, 1.1 and 2.4 at Day 10 and 1.8, 2.0 and 1.8 at Day 100; for the late times (1000 d) after intake, the UFs were increased to 43, 24 and 31, respectively. The model parameters of transfer rates between kidneys and blood, muscle and blood and the rate of transfer from kidneys to urinary bladder content are most influential to the blood clearance and to the whole-body retention of Cs. For the urinary excretion, the parameters of transfer rates from urinary bladder content to urine and from kidneys to urinary bladder content impact mostly. The implication and effect on the estimated equivalent and effective doses of the larger uncertainty of 43 in whole-body retention in the later time, say, after Day 500 will be explored in a successive work in the framework of EURADOS.


Asunto(s)
Radioisótopos de Cesio/farmacocinética , Modelos Biológicos , Radioisótopos de Cesio/sangre , Radioisótopos de Cesio/orina , Simulación por Computador , Exposición a Riesgos Ambientales , Humanos , Exposición Profesional , Dosis de Radiación , Monitoreo de Radiación/estadística & datos numéricos , Protección Radiológica , Radiofármacos/sangre , Radiofármacos/farmacocinética , Radiofármacos/orina , Reproducibilidad de los Resultados , Distribución Tisular , Incertidumbre
10.
Radiat Prot Dosimetry ; 158(3): 276-84, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24114619

RESUMEN

One important parameter for biokinetic plutonium modelling is the ratio between the contents of plutonium in liver and skeleton. Autopsy data show a vast inter-individual variation in the partitioning between these organs. The capacity of recent biokinetic models for plutonium to reproduce these variations was studied. Autopsy data for plutonium amounts in liver and skeleton for both (238)Pu and (239)Pu isotopes can be merged into a single data set following several statistical tests. Simulations with different parameter values generate a mapping between the autopsy values and the model parameters. The observed partitioning distribution can be transformed into a distribution of transfer rates, which would result in the observed data. Besides, the variation in the partitioning between liver and skeleton leads via biliary pathway to a variation in the excretion ratio. This can be used to estimate an individual partitioning factor, which can be used in individual case assessments.


Asunto(s)
Huesos/metabolismo , Hígado/metabolismo , Plutonio/farmacocinética , Algoritmos , Autopsia , Bioensayo , Huesos/efectos de la radiación , Simulación por Computador , Humanos , Hígado/efectos de la radiación , Método de Montecarlo , Factores de Tiempo , Distribución Tisular
11.
Appl Radiat Isot ; 70(3): 538-42, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22115878

RESUMEN

To fully characterize the front dead layer (DL) of an HPGe detector at low photon energy range, its intrinsic efficiency curve was measured using a (241)Am radioactive source in 10-60 keV energy range. A comparison between experimental efficiency and MCNPX results showed that the DL value of 0.4 µm initially quoted by the manufacturer has to be changed to 7.5 µm to reproduce measurements.

12.
Radiat Prot Dosimetry ; 144(1-4): 349-52, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21156780

RESUMEN

EURADOS working group on 'Internal Dosimetry (WG7)' represents a frame to develop activities in the field of internal exposures as coordinated actions on quality assurance (QA), research and training. The main tasks to carry out are the update of the IDEAS Guidelines as a reference document for the internal dosimetry community, the implementation and QA of new ICRP biokinetic models, the assessment of uncertainties related to internal dosimetry models and their application, the development of physiology-based models for biokinetics of radionuclides, stable isotope studies, biokinetic modelling of diethylene triamine pentaacetic acid decorporation therapy and Monte-Carlo applications to in vivo assessment of intakes. The working group is entirely supported by EURADOS; links are established with institutions such as IAEA, US Transuranium and Uranium Registries (USA) and CEA (France) for joint collaboration actions.


Asunto(s)
Radiometría/normas , Americio/análisis , Europa (Continente) , Humanos , Cinética , Método de Montecarlo , Ácido Pentético/química , Plutonio/análisis , Control de Calidad , Monitoreo de Radiación/métodos , Radioisótopos/análisis , Radiometría/métodos , Valores de Referencia , Sistema de Registros , Reproducibilidad de los Resultados , Uranio/análisis
13.
Radiat Prot Dosimetry ; 144(1-4): 402-6, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21183546

RESUMEN

The in vivo monitoring Lab at KIT uses two phoswich detectors for routine lung counting. A simplified model of one of them has been implemented in the two Monte Carlo codes EGSnrc and MCNPX. The active part of the detector consists of a crystal of NaI(Tl) and one of CsI(Tl): the energy deposited in both the crystals have been studied to consider the effect of the anticoincidence logic, present in the read-out electronics of the detectors and not yet studied with Monte Carlo simulations. Only the NaI(Tl) crystal has then been used to study the escape peaks at several energies, which are more prominent at low energies. The results from the two codes have been compared. The comparison of the codes predictions for the escape peaks has been then extended using the model of a germanium detector.


Asunto(s)
Pulmón/efectos de la radiación , Monitoreo de Radiación/instrumentación , Radiometría/instrumentación , Algoritmos , Americio/análisis , Cesio/análisis , Diseño de Equipo , Germanio/análisis , Humanos , Yoduros/análisis , Método de Montecarlo , Fotones , Monitoreo de Radiación/métodos , Radiometría/métodos , Yoduro de Sodio/análisis , Programas Informáticos
14.
Radiat Prot Dosimetry ; 144(1-4): 314-20, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21036807

RESUMEN

This paper describes new biokinetic and dosimetric models, especially those being developed by ICRP which will be used in the forthcoming documents on Occupational Intakes of Radionuclides. It also presents the results of a working group within the European project CONRAD which is being continued within EURADOS. This group is implementing the new models, performing quality assurance of the model implementation (including their description) and giving guidance to the scientific community on the application of the models for individual dose assessment.


Asunto(s)
Monitoreo de Radiación/instrumentación , Protección Radiológica/instrumentación , Radioisótopos/análisis , Radiometría/instrumentación , Calibración , Femenino , Rayos gamma , Tracto Gastrointestinal/efectos de la radiación , Humanos , Cinética , Masculino , Modelos Biológicos , Modelos Teóricos , Control de Calidad , Monitoreo de Radiación/métodos , Protección Radiológica/métodos , Radiometría/métodos
15.
Radiat Prot Dosimetry ; 144(1-4): 339-43, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21071463

RESUMEN

A goal of whole body counting (WBC) is the estimation of the total body burden of radionuclides disregarding the actual position within the body. To achieve the goal, the detectors need to be placed in regions where the photon flux is as independent as possible from the distribution of the source. At the same time, the detectors need high photon fluxes in order to achieve better efficiency and lower minimum detectable activities. This work presents a method able to define the layout of new WBC systems and to study the behaviour of existing ones using both detection efficiency and its dependence on the position of the source within the body of computational phantoms.


Asunto(s)
Radiometría/instrumentación , Recuento Corporal Total/instrumentación , Adulto , Carga Corporal (Radioterapia) , Tamaño Corporal , Simulación por Computador , Femenino , Tracto Gastrointestinal/diagnóstico por imagen , Humanos , Pulmón/diagnóstico por imagen , Masculino , Modelos Estadísticos , Método de Montecarlo , Fantasmas de Imagen , Fotones , Radiometría/métodos , Cintigrafía , Programas Informáticos , Recuento Corporal Total/métodos
16.
Radiat Prot Dosimetry ; 144(1-4): 95-7, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21075765

RESUMEN

The in vivo monitoring laboratory (IVM) at Karlsruhe Institute of Technology (KIT), with one whole body counter and three partial-body counters, is an approved lab for individual monitoring according to German regulation. These approved labs are required to prove their competencies by accreditation to ISO/IEC 17025:2005. In 2007 a quality management system (QMS), which was successfully audited and granted accreditation, was set up at the IVM. The system is based on the ISO 9001 certified QMS of the central safety department of the Research Centre Karlsruhe the IVM belonged to at that time. The system itself was set up to be flexible and could be adapted to the recent organisational changes (e.g. founding of KIT and an institute for radiation research) with only minor effort.


Asunto(s)
Monitoreo de Radiación/normas , Protección Radiológica/normas , Radiometría/normas , Gestión de la Calidad Total , Acreditación , Alemania , Humanos , Internet , Laboratorios , Desarrollo de Programa , Control de Calidad , Monitoreo de Radiación/métodos , Protección Radiológica/métodos , Radiometría/métodos , Seguridad , Programas Informáticos , Universidades
17.
Appl Radiat Isot ; 69(8): 1156-8, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21112789

RESUMEN

The partial-body counter currently installed at KIT is under redesign to add whole-body counting capabilities and replace the current phoswich detectors with HPGe ones, capable of detecting low energy photons ((210)Pb, (241)Am). Different configurations for the positioning of the subject have been tested with the aid of Monte Carlo simulations and the performances attainable with a sitting and a lying configuration were compared. The optimal placement of the detectors was also defined. The simulations were used to estimate the counting efficiencies and also to estimate the Compton scattering produced by (40)K, in turn used to calculate the minimum detectable activities.


Asunto(s)
Americio/análisis , Radioisótopos de Plomo/análisis , Postura , Recuento Corporal Total/métodos , Huesos/diagnóstico por imagen , Calibración , Simulación por Computador , Humanos , Hígado/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Método de Montecarlo , Fantasmas de Imagen , Fotones , Cintigrafía , Cráneo/diagnóstico por imagen
18.
Radiat Prot Dosimetry ; 139(4): 510-8, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20085896

RESUMEN

A usercode for the EGSnrc Monte Carlo package has been developed for the simulation of whole-body counters with NaI(Tl) detectors in stretcher geometry. The geometry of the whole-body counter and the information about the detectors are specified in a plain text file, which enables users to easily adapt the codes to their installation. Bottle phantoms consisting of 1 and 2 l Cautex bottles filled with the radionuclide dissolved in water have been modelled as phantoms depicting the human body to be measured. These kind of phantoms can be defined by the users in the input file. Sets of efficiency factors for calculating activities from counts in measured spectra have been generated by two methods: 'direct simulation of nuclide decay' uses compiled data on photon energies and yields for all nuclides of interest and simulates a given number of decays of those nuclides for phantom masses from 10 to 100 kg while 'single-energy simulation' uses idealized 'nuclides' with single-energy emissions of 100 % yield to study the response of the systems over the energy range of interest (0-2000 keV in 20-keV steps). At University Hospital of Cologne and Karlsruhe Institute of Technology both methods have been successfully applied for the evaluation of spectra measured within intercomparison exercises.


Asunto(s)
Modelos Estadísticos , Método de Montecarlo , Yoduro de Sodio/efectos de la radiación , Recuento Corporal Total/instrumentación , Recuento Corporal Total/normas , Calibración , Simulación por Computador , Diseño de Equipo , Análisis de Falla de Equipo , Alemania , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
Appl Radiat Isot ; 68(7-8): 1438-40, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-19963392

RESUMEN

A virtual model of a Canberra HPGe detector was produced with the aid of MCNPX and of different point sources. The measured and expected count rates were compared. The initial results showed significant discrepancies, therefore additional parametric simulations have been used to improve the model. As a result, the agreement between theoretical and measured performances in the middle-upper part of the spectrum improved, while low energy photons still score the worst, due to incomplete knowledge of the inner structure of the housing that would require additional extensive measurements.

20.
Radiat Prot Dosimetry ; 134(1): 38-48, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19351653

RESUMEN

Administration of diethylene triamine pentaacetic acid (DTPA) can enhance the urinary excretion rate of plutonium (Pu) for several days, but most of this Pu decorporation occurs on the first day after treatment. The development of a biokinetic model describing the mechanisms of decorporation of actinides by administration of DTPA was initiated as a task of the coordinated network for radiation dosimetry project. The modelling process was started by using the systemic biokinetic model for Pu from Leggett et al. and the biokinetic model for DTPA compounds of International Commission on Radiation Protection Publication 53. The chelation of Pu and DTPA to Pu-DTPA was treated explicitly and is assumed to follow a second-order process. It was assumed that the chelation takes place in the blood and in the rapid turnover soft tissues compartments of the Pu model, and that Pu-DTPA behaves in the same way as administered DTPA. First applications of this draft model showed that the height of the peak of urinary excretion after administration of DTPA was determined by the chelation rate. However, repetitions of DTPA administration shortly after the first one showed no effect in the application of the draft model in contrast to data from real cases. The present draft model is thus not yet realistic. Therefore several questions still have to be answered, notably about where the Pu-DTPA complexes are formed, which biological ligands of Pu are dissociated, if Pu-DTPA is stable and if the biokinetics of Pu-DTPA excretion is similar to that of DTPA. Further detailed studies of human contamination cases and experimental data about Pu-DTPA kinetics will be needed in order to address these issues. The work will now be continued within a working group of EURADOS.


Asunto(s)
Quelantes/uso terapéutico , Modelos Biológicos , Ácido Pentético/uso terapéutico , Plutonio/farmacocinética , Traumatismos por Radiación/metabolismo , Traumatismos por Radiación/prevención & control , Humanos , Cinética , Traumatismos por Radiación/etiología
SELECCIÓN DE REFERENCIAS