Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 13(1): 11467, 2023 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-37454190

RESUMEN

Transient electronics hold promise in reducing electronic waste, especially in applications that require only a limited lifetime. While various degradable electronic and physical sensing devices have been proposed, there is growing interest in the development of degradable biochemical sensors. In this work, we present the development of an organic electrochemical transistor (OECT) with degradable electrodes, printed on an eco- and bioresorbable substrate. The influence of the design and materials for the contacts, channel and gate of the transducer, namely poly(3,4-ethylene dioxythiophene):polystyrene sulfonate (PEDOT:PSS) and carbon, is systematically evaluated for the development of OECT-based transient biosensors. The sensing capabilities of the electrochemical transistors are demonstrated with ionic solutions as well as for the enzyme-based detection of glucose. The disposable OECTs show comparable performance to their non-degradable counterparts. Their integration with highly conductive degradable and printable zinc tracks is studied for the realization of interconnects. These eco-friendly OECTs may find applications as disposable and sustainable biochemical sensors, and constitute a step towards bioresorbable biosensors.


Asunto(s)
Técnicas Biosensibles , Transistores Electrónicos , Carbono , Compuestos Orgánicos , Electrodos
2.
IEEE Trans Biomed Circuits Syst ; 17(4): 808-817, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37318976

RESUMEN

Sweat secreted by the human eccrine sweat glands can provide valuable biomarker information during exercise. Real-time non-invasive biomarker recordings are therefore useful for evaluating the physiological conditions of an athlete such as their hydration status during endurance exercise. This work describes a wearable sweat biomonitoring patch incorporating printed electrochemical sensors into a plastic microfluidic sweat collector and data analysis that shows the real-time recorded sweat biomarkers can be used to predict a physiological biomarker. The system was placed on subjects carrying out an hour-long exercise session and results were compared to a wearable system using potentiometric robust silicon-based sensors and to commercially available HORIBA-LAQUAtwin devices. Both prototypes were applied to the real-time monitoring of sweat during cycling sessions and showed stable readings for around an hour. Analysis of the sweat biomarkers collected from the printed patch prototype shows that their real-time measurements correlate well (correlation coefficient ≥ 0.65) with other physiological biomarkers such as heart rate and regional sweat rate collected in the same session. We show for the first time, that the real-time sweat sodium and potassium concentration biomarker measurements from the printed sensors can be used to predict the core body temperature with root mean square error (RMSE) of 0.02 °C which is 71% lower compared to the use of only the physiological biomarkers. These results show that these wearable patch technologies are promising for real-time portable sweat monitoring analytical platforms, especially for athletes performing endurance exercise.


Asunto(s)
Técnicas Biosensibles , Dispositivos Electrónicos Vestibles , Humanos , Sudor/química , Temperatura Corporal , Electrólitos , Biomarcadores/análisis
3.
Sci Rep ; 13(1): 1962, 2023 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-36737477

RESUMEN

The strong clinical demand for more accurate and personalized health monitoring technologies has called for the development of additively manufactured wearable devices. While the materials palette for additive manufacturing continues to expand, the integration of materials, designs and digital fabrication methods in a unified workflow remains challenging. In this work, a 3D printing platform is proposed for the integrated fabrication of silicone-based soft wearables with embedded piezoresistive sensors. Silicone-based inks containing cellulose nanocrystals and/or carbon black fillers were thoroughly designed and used for the direct ink writing of a shoe insole demonstrator with encapsulated sensors capable of measuring both normal and shear forces. By fine-tuning the material properties to the expected plantar pressures, the patient-customized shoe insole was fully 3D printed at room temperature to measure in-situ gait forces during physical activity. Moreover, the digitized approach allows for rapid adaptation of the sensor layout to meet specific user needs and thereby fabricate improved insoles in multiple quick iterations. The developed materials and workflow enable a new generation of fully 3D printed soft electronic devices for health monitoring.

4.
Microsyst Nanoeng ; 9: 19, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36844941

RESUMEN

The development of fully solution-processed, biodegradable piezoelectrics is a critical step in the development of green electronics towards the worldwide reduction of harmful electronic waste. However, recent printing processes for piezoelectrics are hindered by the high sintering temperatures required for conventional perovskite fabrication techniques. Thus, a process was developed to manufacture lead-free printed piezoelectric devices at low temperatures to enable integration with eco-friendly substrates and electrodes. A printable ink was developed for screen printing potassium niobate (KNbO3) piezoelectric layers in microns of thickness at a maximum processing temperature of 120 °C with high reproducibility. Characteristic parallel plate capacitor and cantilever devices were designed and manufactured to assess the quality of this ink and evaluate its physical, dielectric, and piezoelectric characteristics; including a comparison of behaviour between conventional silicon and biodegradable paper substrates. The printed layers were 10.7-11.2 µm thick, with acceptable surface roughness values in the range of 0.4-1.1 µm. The relative permittivity of the piezoelectric layer was 29.3. The poling parameters were optimised for the piezoelectric response, with an average longitudinal piezoelectric coefficient for samples printed on paper substrates measured as d 33, eff, paper = 13.57 ± 2.84 pC/N; the largest measured value was 18.37 pC/N on paper substrates. This approach to printable biodegradable piezoelectrics opens the way forward for fully solution-processed green piezoelectric devices.

6.
ACS Sens ; 7(9): 2721-2731, 2022 09 23.
Artículo en Inglés | MEDLINE | ID: mdl-36054907

RESUMEN

The dysregulation of the hormone cortisol is related to several pathological states, and its monitoring could help prevent severe stress, fatigue, and mental diseases. While wearable antibody-based biosensors could allow real-time and simple monitoring of antigens, an accurate and low-cost antibody-based cortisol detection through electrochemical methods is considerably challenging due to its low concentration and the high ionic strength of real biofluids. Here, a label-free and fast sensor for cortisol detection is proposed based on antibody-coated organic electrochemical transistors. The developed devices show unprecedented high sensitivities of 50 µA/dec for cortisol sensing in high-ionic-strength solutions with effective cortisol detection demonstrated with real human sweat. The sensing mechanism is analyzed through impedance spectroscopy and confirmed with electrical models. Compared to existing methods requiring bulky and expensive laboratory equipment, these wearable devices enable point-of-care cortisol detection in 5 min with direct sweat collection for personalized well-being monitoring.


Asunto(s)
Técnicas Biosensibles , Dispositivos Electrónicos Vestibles , Anticuerpos/análisis , Técnicas Biosensibles/métodos , Técnicas Electroquímicas/métodos , Humanos , Hidrocortisona/análisis , Sudor/química
7.
Rev Med Suisse ; 17(745): 1289-1294, 2021 Jul 14.
Artículo en Francés | MEDLINE | ID: mdl-34264030

RESUMEN

Sweat is a body fluid produced by the sweat glands and is mainly composed of water. Sweat has various functions, the two main ones being the evacuation of heat produced by the body, especially during exercise, and the maintenance of skin homeostasis. Its production is highly variable and depends on many individual and environmental factors. Various diseases or conditions affect its proper functioning. This article presents an overview of the characteristics, the main health issues, and the current and potential applications related to sweat.


La sueur est un fluide corporel produit par les glandes sudoripares et composé principalement d'eau. La transpiration remplit diverses fonctions, dont les principales sont l'évacuation de la chaleur produite par l'organisme, en particulier durant l'effort physique, et le maintien de l'homéostasie de la peau. Sa production est très variable quantitativement et qualitativement et dépend de multiples facteurs individuels et environnementaux. Différentes pathologies ou conditions altèrent son bon fonctionnement. Cet article présente un aperçu des caractéristiques, des principaux problèmes de santé et des applications actuelles et potentielles en lien avec la sueur.


Asunto(s)
Sudor , Sudoración , Ejercicio Físico , Calor , Humanos , Piel
8.
Sci Rep ; 10(1): 16664, 2020 10 07.
Artículo en Inglés | MEDLINE | ID: mdl-33028862

RESUMEN

The rapid evolution of the neuromorphic computing stimulates the search for novel brain-inspired electronic devices. Synaptic transistors are three-terminal devices that can mimic the chemical synapses while consuming low power, whereby an insulating dielectric layer physically separates output and input signals from each other. Appropriate choice of the dielectric is crucial in achieving a wide range of operation frequencies in these devices. Here we report synaptic transistors with printed aluminum oxide dielectrics, improving the operation frequency of solution-processed synaptic transistors by almost two orders of magnitude to 50 kHz. Fabricated devices, yielding synaptic response for all audio frequencies (20 Hz to 20 kHz), are employed in an acoustic response system to show the potential for future research in neuro-acoustic signal processing with printed oxide electronics.


Asunto(s)
Materiales Biomiméticos , Procesamiento de Señales Asistido por Computador , Sinapsis/fisiología , Transistores Electrónicos , Óxido de Aluminio , Biomimética , Electrónica
9.
ACS Appl Mater Interfaces ; 9(30): 25553-25558, 2017 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-28726384

RESUMEN

We report a light, flexible, and low-power poly(ionic liquid)/alumina composite CO2 sensor. We monitor the direct-current resistance changes as a function of CO2 concentration and relative humidity and demonstrate fast and reversible sensing kinetics. Moreover, on the basis of the alternating-current impedance measurements we propose a sensing mechanism related to proton conduction and gas diffusion. The findings presented herein will promote the development of organic/inorganic composite CO2 gas sensors. In the future, such sensors will be useful for numerous practical applications ranging from indoor air quality control to the monitoring of manufacturing processes.

10.
Adv Mater ; 29(30)2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28603892

RESUMEN

Flexible high-voltage thin-film transistors (HVTFTs) operating at more than 1 kV are integrated with compliant dielectric elastomer actuators (DEA) to create a flexible array of 16 independent actuators. To allow for high-voltage operation, the HVTFT implements a zinc-tin oxide channel, a thick dielectric stack, and an offset gate. At a source-drain bias of 1 kV, the HVTFT has a 20 µA on-current at a gate voltage bias of 30 V. Their electrical characteristics enable the switching of DEAs which require drive voltages of over 1 kV, making control of an array simpler in comparison to the use of external high-voltage switching. These HVTFTs are integrated in a flexible haptic display consisting of a 4 × 4 matrix of DEAs and HVTFTs. Using a single 1.4 kV supply, each DEA is independently switched by its associated HVTFT, requiring only a 30 V gate voltage for full DEA deflection. The 4 × 4 display operates well even when bent to a 5 mm radius of curvature. By enabling DEA switching at low voltages, flexible metal-oxide HVTFTs enable complex flexible systems with dozens to hundreds of independent DEAs for applications in haptics, Braille displays, and soft robotics.

11.
Anal Chem ; 87(8): 4455-63, 2015 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-25810264

RESUMEN

This paper presents the optimization of a micro gas preconcentrator (µ-GP) system applied to atmospheric pollution monitoring, with the help of a complete modeling of the preconcentration cycle. Two different approaches based on kinetic equations are used to illustrate the behavior of the micro gas preconcentrator for given experimental conditions. The need for high adsorption flow and heating rate and for low desorption flow and detection volume is demonstrated in this paper. Preliminary to this optimization, the preconcentration factor is discussed and a definition is proposed.


Asunto(s)
Contaminación del Aire/análisis , Atmósfera/química , Monitoreo del Ambiente , Gases/análisis , Modelos Químicos
12.
Anal Chem ; 86(18): 8951-8, 2014 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-25144386

RESUMEN

Conducting polyaniline-based chemiresistors on printed polymeric micro-hotplates were developed, showing sensitive and selective detection of ammonia vapor in air. The devices consist of a fully inkjet-printed silver heater and interdigitated electrodes on a polyethylene naphthalate substrate, separated by a thin dielectric film. The integrated heater allowed operation at elevated temperatures, enhancing the ammonia sensing performance. The printed sensor designs were optimized over two different generations, to improve the thermal performance through careful design of the shape and dimension of the heater element. A vapor-phase deposition polymerization technique was adapted to produce polyaniline sensing layers doped with poly(4-styrenesulfonic acid). The resulting sensor had better thermal stability and sensing performance when compared with conventional polyaniline-based sensors, and this was attributed to the polymeric dopant used in this study. Improved long-term stability of the sensors was achieved by electrodeposition of gold on the silver electrodes. Response to sub-parts-per-million concentrations of ammonia even under humid conditions was observed.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA