Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Metrologia ; 552018.
Artículo en Inglés | MEDLINE | ID: mdl-31080297

RESUMEN

The International Committee for Weights and Measures (CIPM), at its meeting in October 2017, followed the recommendation of the Consultative Committee for Units (CCU) on the redefinition of the kilogram, ampere, kelvin and mole. For the redefinition of the kelvin, the Boltzmann constant will be fixed with the numerical value 1.380 649 × 10-23 J K-1. The relative standard uncertainty to be transferred to the thermodynamic temperature value of the triple point of water will be 3.7 × 10-7, corresponding to an uncertainty in temperature of 0.10 mK, sufficiently low for all practical purposes. With the redefinition of the kelvin, the broad research activities of the temperature community on the determination of the Boltzmann constant have been very successfully completed. In the following, a review of the determinations of the Boltzmann constant k, important for the new definition of the kelvin and performed in the last decade, is given.

2.
Philos Trans A Math Phys Eng Sci ; 374(2064): 20150043, 2016 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-26903097

RESUMEN

The mise-en-pratique for the definition of the kelvin at high temperatures will formally allow dissemination of thermodynamic temperature either directly or mediated through high-temperature fixed points (HTFPs). In this paper, these two distinct dissemination methods are evaluated, namely source-based and detector-based. This was achieved by performing two distinct dissemination trials: one based on HTFPs, the other based on absolutely calibrated radiation thermometers or filter radiometers. These trials involved six national metrology institutes in Europe in the frame of the European Metrology Research Programme joint project 'Implementing the new kelvin' (InK). The results have shown that both dissemination routes are possible, with similar standard uncertainties of 1-2 K, over the range 1273-2773 K, showing that, depending on the facilities available in the laboratory, it will soon be possible to disseminate thermodynamic temperatures above 1273 K to users by either of the two methods with uncertainties comparable to the current temperature scale.

3.
Philos Trans A Math Phys Eng Sci ; 374(2064): 20150044, 2016 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-26903099

RESUMEN

The thermodynamic temperature of the point of inflection of the melting transition of Re-C, Pt-C and Co-C eutectics has been determined to be 2747.84 ± 0.35 K, 2011.43 ± 0.18 K and 1597.39 ± 0.13 K, respectively, and the thermodynamic temperature of the freezing transition of Cu has been determined to be 1357.80 ± 0.08 K, where the ± symbol represents 95% coverage. These results are the best consensus estimates obtained from measurements made using various spectroradiometric primary thermometry techniques by nine different national metrology institutes. The good agreement between the institutes suggests that spectroradiometric thermometry techniques are sufficiently mature (at least in those institutes) to allow the direct realization of thermodynamic temperature above 1234 K (rather than the use of a temperature scale) and that metal-carbon eutectics can be used as high-temperature fixed points for thermodynamic temperature dissemination. The results directly support the developing mise en pratique for the definition of the kelvin to include direct measurement of thermodynamic temperature.

4.
Rev Sci Instrum ; 87(12): 125101, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28040967

RESUMEN

We describe a high-performance, transportable, versatile spectroradiometer based on an acousto-optical tunable filter (AOTF). The instrument was developed for temperature metrology, namely, to determine the thermodynamic temperature of black bodies above the Ag freezing point (961.78 °C). Its main design feature is the attenuation of the diffraction side lobes (and, thus, out-of-band stray light) thanks to the use of a double-pass configuration. The radiofrequency tuning of the AOTF allows continuous, fine, and rapid wavelength control over a wide spectral range (650 nm-1000 nm). The instrument tunability can be easily calibrated with an Ar spectral lamp with reproducibility within 10 pm over one week. The instrument was characterised in terms of relative signal stability (few 10-4) and wavelength stability (1 pm) over several hours. The spectral responsivity of the instrument was calibrated with two complementary methods: tuning of the wavelength of the optical source or tuning the radiofrequency of the AOTF. Besides the application for thermodynamic temperature determination at the lowest uncertainty level, this instrument can also be used for multispectral non-contact thermometry of processed materials of non-grey and non-unitary emissivity (in the glass or metallurgical industries).

5.
Opt Express ; 18(25): 25642-8, 2010 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-21164910

RESUMEN

Slow light propagation is demonstrated by implementing Coherent Population Oscillations in a silica fiber doped with erbium ions in a ring surrounding the single mode core. Though only the wings of the mode interact with erbium ions, group velocities around 1360 m/s are obtained without any spatial distortion of the propagating mode.


Asunto(s)
Tecnología de Fibra Óptica , Láseres de Estado Sólido , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Luz , Dispersión de Radiación
6.
Phys Rev Lett ; 98(25): 250801, 2007 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-17678007

RESUMEN

We have recorded the Doppler profile of a well-isolated rovibrational line in the nu(2) band of (14)NH(3). Ammonia gas was placed in an absorption cell thermalized by a water-ice bath. By extrapolating to zero pressure, we have deduced the Doppler width which gives a first measurement of the Boltzmann constant k(B) by laser spectroscopy. A relative uncertainty of 2 x 10(-4) has been obtained. The present determination should be significantly improved in the near future and contribute to a new definition of the kelvin.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...