Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Ultrasound Med Biol ; 45(5): 1284-1296, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30799125

RESUMEN

Angiogenesis, the formation of new vessels, is one of the key mechanisms in tumor development and an appealing target for therapy. Non-invasive, high-resolution, high-sensitivity, quantitative 3-D imaging techniques are required to correctly depict tumor heterogeneous vasculature over time. Ultrafast Doppler was recently introduced and provides an unprecedented combination of resolution, penetration depth and sensitivity without requiring any contrast agents. The technique was further extended to three dimensions with ultrafast Doppler tomography (UFD-T). In this work, UFD-T was applied to the monitoring of tumor angiogenesis in vivo, providing structural and functional information at different stages of development. UFD-T volume renderings revealed that our murine model's vasculature stems from pre-existing vessels and sprouts to perfuse the whole volume as the tumor grows until a critical size is reached. Then, as the network becomes insufficient, the tumor core is no longer irrigated because the vasculature is concentrated mainly in the periphery. In addition to spatial distribution and growth patterns, UFD-T allowed a quantitative analysis of vessel size and length, revealing that the diameter distribution of vessels remained relatively constant throughout tumor growth. The network is dominated by small vessels at all stages of tumor development, with more than 74% of the vessels less than 200 µm in diameter. This study also found that cumulative vessel length is more closely related to tumor radius than volume, indicating that the vascularization becomes insufficient when a critical mass is reached. UFD-T was also compared with dynamic contrast-enhanced ultrasound and found to provide complementary information regarding the link between structure and perfusion. In conclusion, UFD-T is capable of in vivo quantitative assessment of the development of tumor vasculature (vessels with blood speed >1 mm/s [sensitivity limit] assessed with a resolution limit of 80 µm) in 3 dimensions. The technique has very interesting potential as a tool for treatment monitoring, response assessment and treatment planning for optimal drug efficiency.


Asunto(s)
Imagenología Tridimensional/métodos , Neoplasias/irrigación sanguínea , Neoplasias/diagnóstico por imagen , Neovascularización Patológica/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Ultrasonografía Doppler/métodos , Animales , Modelos Animales de Enfermedad , Ratones , Imagen Multimodal/métodos
2.
Antioxid Redox Signal ; 24(16): 939-58, 2016 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-27139586

RESUMEN

SIGNIFICANCE: Reactive Oxygen Species (ROS) may regulate signaling, ion channels, transcription factors, and biosynthetic processes. ROS-related diseases can be due to either a shortage or an excess of ROS. RECENT ADVANCES: Since the biological activity of ROS depends on not only concentration but also spatiotemporal distribution, real-time imaging of ROS, possibly in vivo, has become a need for scientists, with potential for clinical translation. New imaging techniques as well as new contrast agents in clinically established modalities were developed in the previous decade. CRITICAL ISSUES: An ideal imaging technique should determine ROS changes with high spatio-temporal resolution, detect physiologically relevant variations in ROS concentration, and provide specificity toward different redox couples. Furthermore, for in vivo applications, bioavailability of sensors, tissue penetration, and a high signal-to-noise ratio are additional requirements to be satisfied. FUTURE DIRECTIONS: None of the presented techniques fulfill all requirements for clinical translation. The obvious way forward is to incorporate anatomical and functional imaging into a common hybrid-imaging platform. Antioxid. Redox Signal. 24, 939-958.


Asunto(s)
Enfermedades Metabólicas/diagnóstico por imagen , Especies Reactivas de Oxígeno/metabolismo , Animales , Humanos , Peroxidación de Lípido , Enfermedades Metabólicas/metabolismo , Imagen Óptica
3.
Artículo en Inglés | MEDLINE | ID: mdl-24158285

RESUMEN

Perfusion parameter estimation from dynamic contrast-enhanced ultrasound (DCE-US) data relies on fitting parametric models of flow to curves describing linear echo power as a function of time. The least squares criterion is generally used to fit these models to data. This criterion is optimal in the sense of maximum likelihood under the assumption of an additive white Gaussian noise. In the current work, it is demonstrated that this assumption is not held for DCEUS. A better-adapted maximum likelihood criterion based on a multiplicative model is proposed. It is tested on simulated bolus perfusion data and on 11 sequences acquired in vivo during bolus perfusion of contrast agent in the cortex of healthy murine kidney, an area where the perfusion is expected to be approximately homogeneous. Results on simulated data show a significant improvement (p < 0.05) of the precision and the accuracy for the estimations of perfusion parameters time to peak (TTP), wash-in rate (WiR), and mean transit time (MTT). On the 11 in vivo sequences, the new method leads to a significant reduction (p < 0.05) in the variation of parametric maps for 9 sequences for TTP and 10 sequences for WiR and MTT. The mean percent decreases of the coefficient of variation are 40%, 25%, and 59% for TTP, WiR, and MTT, respectively. This method should contribute to a more robust and accurate estimation of perfusion parameters and an improved resolution of parametric imaging.


Asunto(s)
Medios de Contraste/química , Procesamiento de Imagen Asistido por Computador/métodos , Ultrasonografía/métodos , Animales , Simulación por Computador , Riñón/diagnóstico por imagen , Análisis de los Mínimos Cuadrados , Ratones , Fosfolípidos/química , Reproducibilidad de los Resultados , Hexafluoruro de Azufre/química
4.
Eur Radiol ; 23(3): 805-15, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23001579

RESUMEN

OBJECTIVE: To evaluate morphological and perfusion changes in liver metastases of neuroendocrine tumours by contrast-enhanced ultrasound (CEUS) after transarterial embolisation with bead block (TAE) or trans-arterial chemoembolisation with doxorubicin-eluting beads (DEB-TACE). METHODS: In this retrospective study, seven patients underwent TAE, and ten underwent DEB-TACE using beads of the same size. At 1 day before embolisation, 2 days, 1 month and 3 months after the procedure, a destruction-replenishment study using CEUS was performed with a microbubble-enhancing contrast material on a reference tumour. Relative blood flow (rBF) and relative blood volume (rBV) were obtained from the ratio of values obtained in the tumour and in adjacent liver parenchyma. Morphological parameters such as the tumour's major diameter and the viable tumour's major diameter were also measured. A parameter combining functional and morphological data, the tumour vitality index (TVI), was studied. The Wilcoxon rank-sum test and Fisher's test were used to compare treatment groups. RESULTS: At 3 months rBF, rBV and TVI were significantly lower (P = 0.005, P = 0.04 and P = 0.03) for the group with doxorubicin. No difference in morphological parameters was found throughout the follow-up. CONCLUSIONS: One parameter, TVI, could evaluate the morphological and functional response to treatments.


Asunto(s)
Embolización Terapéutica/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Neovascularización Patológica/terapia , Tumores Neuroendocrinos/diagnóstico por imagen , Tumores Neuroendocrinos/secundario , Ultrasonografía/métodos , Anciano , Medios de Contraste , Femenino , Humanos , Neoplasias Hepáticas/terapia , Masculino , Persona de Mediana Edad , Tumores Neuroendocrinos/terapia , Fosfolípidos , Estudios Retrospectivos , Hexafluoruro de Azufre , Resultado del Tratamiento
5.
Ultrasound Med Biol ; 32(2): 183-90, 2006 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16464663

RESUMEN

The goal of this study was to validate high-frequency (24 MHz) ultrasound imaging techniques for early detection and follow-up of renal tumors in a murine Wilms' tumor model (n = 26). For 11 mice, maximum tumor dimensions were estimated from images along three orthogonal axes for comparison with posteuthanasia caliper and histologic measurements. Tumor size in the 15 remaining mice was checked biweekly. The mice were then euthanized and histologic study assessed tumor position and nature. Tumors were detected in vivo between 7 to 14 days after injection of tumor-inducing cells. Tumor maximum cross-sectional area varied from 0.07 mm2 to 5.7 mm2 at the time of initial detection. The relative r.m.s. error between ultrasonic and histologic estimations of maximum cross-sectional area was estimated to be 19%. Results demonstrate feasibility of noninvasive ultrasound biomicroscopy early detection and characterization of renal tumor development for longitudinal monitoring of the same animal.


Asunto(s)
Neoplasias Renales/diagnóstico por imagen , Microscopía Acústica/métodos , Tumor de Wilms/diagnóstico por imagen , Animales , Línea Celular Tumoral , Modelos Animales de Enfermedad , Femenino , Riñón/diagnóstico por imagen , Riñón/patología , Neoplasias Renales/patología , Ratones , Ratones Desnudos , Tumor de Wilms/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA